Open Access. Powered by Scholars. Published by Universities.®

Fluid Dynamics Commons™

Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences

Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 31 - 33 of 33

Full-Text Articles in Fluid Dynamics

Design And Fabrication Of Nanofluidic Systems With Integrated Sensing Electrodes For Rapid Biomolecule Characterization, Taylor Bradley Busch May 2013

Design And Fabrication Of Nanofluidic Systems With Integrated Sensing Electrodes For Rapid Biomolecule Characterization, Taylor Bradley Busch

Graduate Theses and Dissertations

A transparent nanofluidic system with embedded sensing electrodes was designed and fabricated by integrating Atomic Force Microscopy (AFM) nanolithography, Focused Ion Beam (FIB) milling and metal deposition, and standard microfabrication processing. The fabrication process started with the evaporation of chrome/gold (Cr/Au) onto a Pyrex 7740 wafer followed by photolithography and wet etching of the microchannels. The wafer was patterned a second time to form Au microelectrodes with 15-45 micrometer separation gaps in the nanochannel region. Sensing electrodes (up to one micron wide) were then deposited using FIB to bridge the gaps. The nanochannels were realized through both AFM nanolithography and …


Microfluidic Impedance Spectroscopy As A Tool For Quantitative Biology And Biotechnology, Ahmet C. Sabuncu, Jie Zhuang, Juergen F. Kolb, Ali Beskok Jan 2012

Microfluidic Impedance Spectroscopy As A Tool For Quantitative Biology And Biotechnology, Ahmet C. Sabuncu, Jie Zhuang, Juergen F. Kolb, Ali Beskok

Mechanical & Aerospace Engineering Faculty Publications

A microfluidic device that is able to perform dielectric spectroscopy is developed. The device consists of a measurement chamber that is 250 μm thick and 750 μm radius. Around 1000 cells fit inside the chamber assuming average quantities for cell radius and volume fraction. This number is about 1000 folds lower than the capacity of conventional fixtures. A T-cell leukemia cell line Jurkat is tested using the microfluidic device. Measurements of deionized water and salt solutions are utilized to determine parasitic effects and geometric capacitance of the device. Physical models, including Maxwell-Wagner mixture and double shell models, are used to …


Left Ventricular Assist Devices: Engineering Design Considerations, Marwan A. Simaan, Eduardo Divo, George Faragallah, Yu Wang Aug 2011

Left Ventricular Assist Devices: Engineering Design Considerations, Marwan A. Simaan, Eduardo Divo, George Faragallah, Yu Wang

Publications

Patients with end-stage congestive heart failure awaiting heart transplantation often wait long periods of time (300 days or more on the average) before a suitable donor heart becomes available. The medical community has placed increased emphasis on the use of Left Ventricular Assist Devices or LVADs that can substitute for, or enhance, the function of the natural heart while the patient is waiting for the heart transplant (Poirier, 1997; Frazier & Myers, 1999). Essentially, a rotary LVAD is a pump that operates continuously directing blood from the left ventricle into the aorta by avoiding the aortic valve. Generally speaking, the …