Open Access. Powered by Scholars. Published by Universities.®

Biomechanical Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Mechanical Engineering

Discipline
Institution
Keyword
Publication Year
Publication Type

Articles 31 - 60 of 60

Full-Text Articles in Biomechanical Engineering

Self-Powered Ankle Prosthetic, Corina M. Espelien, Kelsey Pietzsch, Anna Sullivan Jun 2017

Self-Powered Ankle Prosthetic, Corina M. Espelien, Kelsey Pietzsch, Anna Sullivan

Mechanical Engineering

Originating from QL+'s customer requirements, the main technical specifications were to have 80% physiological range of motion, elastic energy return, impact absorption, and no external power sources. Based on the background research conducted and the discussions with experts in the field, the project team decided to focus on designing a prosthetic that focused on plantarflexion and dorsiflexion for a more comfortable gait. The main components of the final design are a hydraulic shock absorber, cam, torsion springs, heel, stopper, and separated keel. The heel, front and back keels, and stopper were manufactured out of carbon fiber. The link, lever, attachment …


Biomimetic Seal Flipper Test Rig, Gordon D. Belyea, Laura Kawashiri, Dylan Rinker, Kurt Beske Jun 2016

Biomimetic Seal Flipper Test Rig, Gordon D. Belyea, Laura Kawashiri, Dylan Rinker, Kurt Beske

Mechanical Engineering

No abstract provided.


Non-Puncturing, No Slip Thv Leaflet Gripper, Brooks Kelly, Eric Nagaoka, Johnny Phane Jun 2016

Non-Puncturing, No Slip Thv Leaflet Gripper, Brooks Kelly, Eric Nagaoka, Johnny Phane

Mechanical Engineering

Confidential


Low-Cost Prosthetic Transfemoral Socket, Emelie Deans, Joshua Ledgerwood, Leah Moore, Shaina Jung, Kristen Temnyk Jun 2016

Low-Cost Prosthetic Transfemoral Socket, Emelie Deans, Joshua Ledgerwood, Leah Moore, Shaina Jung, Kristen Temnyk

Mechanical Engineering

The goal of this senior project was to design and fabricate a low-cost adjustable prosthetic socket for above the knee amputees. This low-cost consideration was incorporated with the original intent to be used in Fiji, however, this changed to the Dominican Republic. It became clear that the need for an adjustable socket was more as a transitional socket. This transitional socket would be used for the first 6 -12 months upon amputation because this when the most amount of volume fluctuation occurs. The project sponsor, LIM Innovations, has already designed the Infinite Socket which contains four main functioning parts: baseplate, …


Prosthetic Socket Cooling System, Benjamin K. Kraw, Kathy Ha, Derek Piastrelli, Cuong Lai Jun 2016

Prosthetic Socket Cooling System, Benjamin K. Kraw, Kathy Ha, Derek Piastrelli, Cuong Lai

Mechanical Engineering

A team of four senior-level undergraduate students in the Interdisciplinary Senior Project Design course in the Engineering Department of California Polytechnic State University: San Luis Obispo have worked to develop a prosthetic socket cooling system, namely for veteran Taylor Morris and exclusively for a transfemoral prosthetic socket, under the Quality of Life+ Laboratory. This cooling system will utilize the thermoelectric effect known as the Peltier effect to transmit heat generated from the residual limb to the surrounding environment by means of forced convection over small aluminum heat sinks. Two measurement devices have also been developed to, one, measure the heat …


Carbon Articulating Backpack Spine, Salvatore Monforte Iii, Darci Lawrence, Savan Patel Dec 2015

Carbon Articulating Backpack Spine, Salvatore Monforte Iii, Darci Lawrence, Savan Patel

Mechanical Engineering

In the field, firefighters and Urban Search and Rescue (USAR) personnel need to transport variable loads efficiently, safely, and comfortably while simultaneously performing certain physical tasks. Current models of external and internal framed backpacks distribute the load of a pack efficiently, but do not allow for the natural movement of the wearer. Wolfpack Gear, Inc. proposed the need for a system which both effectively carries a load and allows for the unhindered natural movement of the user. The goal of this project was to design, build, and test an articulating backpack support system. The first stage of the project comprised …


Sapien3 Comb Stitch Improvement For Edwards Lifesciences, William Harley, Thomas Pluschkell, John Mctigue, Garrett Reed Jun 2015

Sapien3 Comb Stitch Improvement For Edwards Lifesciences, William Harley, Thomas Pluschkell, John Mctigue, Garrett Reed

Mechanical Engineering

The complete senior project report was submitted to the project advisor and sponsor. The results of this project are of a confidential nature and will not be published at this time.


Team Nathan Suspension, Frankie J. Wiggins, Alex D. Seitz, Justin P. Bautista Oct 2014

Team Nathan Suspension, Frankie J. Wiggins, Alex D. Seitz, Justin P. Bautista

Mechanical Engineering

Nathan Cooper is an 8-year old boy with Spinal Muscular Atrophy (SMA). SMA has affected Nathan’s muscle development and requires him to use the Standing Dani™ mobility device. The Standing Dani is a motorized standing wheelchair, or Wheelstand. Nathan controls and uses it to get around. Though the Standing Dani performs well for most functions, it has some distinct issues. The primary issue that this project addresses is its lack of suspension and the discomfort that Nathan feels as a result. After talking with our client, we developed several specifications generally related to geometry, safety, vehicle dynamics, and reliability. Many …


Low-Cost Strider For Guatemala, Nicole Catherine Cooper, Gonzalo Hernandez, Jared W. Tower Jun 2014

Low-Cost Strider For Guatemala, Nicole Catherine Cooper, Gonzalo Hernandez, Jared W. Tower

Mechanical Engineering

The purpose of this project was to create a strider, a type of standing rehabilitation device, for children in developing countries who have trouble walking and supporting their full body weight. The project was initially brought to us by Cal Poly professor Brian Self, who had visited a clinic in San Marcos and determined that there were children there who had difficulties with walking and were a need for a rehabilitation device. The team discussed the problem with Dr. Self, Matt Robinson (a local San Luis Obispo prosthetist), and Cal Poly physics professor Pete Schwartz, all of whom had visited …


2d Wireform Process Improvement, Katy Conlin, Carlo Ebora, Jordan Gamble Jun 2014

2d Wireform Process Improvement, Katy Conlin, Carlo Ebora, Jordan Gamble

Mechanical Engineering

The body of this work has been created for Edwards Lifesciences in conjunction with senior project requirements. As such, the information produced and contained within is under a non‐disclosure agreement. As per request by sponsor, the body of the work will not be submitted to any outside parties, and the title page will serve as proof of completion.


Semi-Automated Method Of Assembly For Physio Ii Ring, Cameron Anderson Deines, Kelsey Jean Engel, Christopher Kiuyen Wong Jun 2014

Semi-Automated Method Of Assembly For Physio Ii Ring, Cameron Anderson Deines, Kelsey Jean Engel, Christopher Kiuyen Wong

Mechanical Engineering

No abstract provided.


Folding Wheelchair Improvement, Matthew Edison Grace, Kevin Alan Miyamoto, Andrey Lee Oliveira Jun 2014

Folding Wheelchair Improvement, Matthew Edison Grace, Kevin Alan Miyamoto, Andrey Lee Oliveira

Mechanical Engineering

No abstract provided.


Intuity Sleeve Redesign, Maxwell Arnold, Brittany Kinkade, Dominic Nicoletti Jun 2013

Intuity Sleeve Redesign, Maxwell Arnold, Brittany Kinkade, Dominic Nicoletti

Mechanical Engineering

No abstract provided.


Adaptive Floor Hockey Device, Chris Gaul, Ricardo Gaytan, Matt Spaulding, Shannon Brant Jun 2013

Adaptive Floor Hockey Device, Chris Gaul, Ricardo Gaytan, Matt Spaulding, Shannon Brant

Mechanical Engineering

Sean is a young boy living with ataxic cerebral palsy. Ataxic cerebral

palsy affects Sean’s balance and coordination, so he uses a walker to

increase his mobility. Sean would like to play Special Olympics Floor

Hockey but his walker prevents him from participating. The goal of this

Senior project was to develop a device to be attached to his previous

walker to allow Sean to play floor hockey in the least restrictive

environment possible. The Adaptive Floor Hockey Device is the product

we designed to satisfy this need.


Design And Testing Of A Low Cost Prosthetic Foot, Shalan Ertis, John Kearns, Seija Maniskas Jun 2012

Design And Testing Of A Low Cost Prosthetic Foot, Shalan Ertis, John Kearns, Seija Maniskas

Mechanical Engineering

No abstract provided.


Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser Jun 2012

Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser

Mechanical Engineering

Amputations are a common occurrence in soldiers returning home who have suffered the effects of IED and munitions explosions. For upper limb amputees, trans-radial amputations are the most common. Traditional hook devices do not offer an adequate level of normalcy for users, prompting the use of myoelectric devices. While current myoelectric devices do offer a more natural experience, they come with a host of other problems that makes their adoption by service personnel not desirable or not permitted by the VA. PolyGrasp Reach seeks to reduce weight and cost and improve performance. This addresses several of the issues with devices …


Access|Closure Balloon Catheter Redesign Project, Keenan Bamburg, Yvette Castillo, Elizabeth Eskildsen Dec 2011

Access|Closure Balloon Catheter Redesign Project, Keenan Bamburg, Yvette Castillo, Elizabeth Eskildsen

Mechanical Engineering

No abstract provided.


Challenger J Hockey Prosthesis Final Design Report, Ryan Bakker, Spencer Noe, Christopher Perkins Dec 2011

Challenger J Hockey Prosthesis Final Design Report, Ryan Bakker, Spencer Noe, Christopher Perkins

Mechanical Engineering

The content of this report is withheld as confidential. QL+ is the owner of the intellectual property created throughout the duration of this project. Dr. Tom Mase (mechanical engineering) maintains a full copy of the report and intends to disseminate it upon completion of the necessary intellectual property protection measures.


Golf Prosthesis Final Design Report, Joseph Barcus, Lauren Wilson, Ryan Satcher Dec 2011

Golf Prosthesis Final Design Report, Joseph Barcus, Lauren Wilson, Ryan Satcher

Mechanical Engineering

A prosthetic attachment designed to allow an upper extremity bilateral amputee to golf.


Rock-N-Bowler Ii, Josh Grip, Travis Rodrigues, Richard Rozporka Jun 2011

Rock-N-Bowler Ii, Josh Grip, Travis Rodrigues, Richard Rozporka

Mechanical Engineering

The report of the creation of an adaptive bowling device designed for people in powered wheelchairs. The basic design is a ramp that attaches to the wheelchair and has the ability to add spin to the ball to allow the user to hook the ball.


Low-Cost Prosthetic Leg For The Vida Nueva Prosthesis Clinic, Sarah M. Baker, Justin G. Lekos, Jen Van Donk, Kevin Yamauchi Jan 2011

Low-Cost Prosthetic Leg For The Vida Nueva Prosthesis Clinic, Sarah M. Baker, Justin G. Lekos, Jen Van Donk, Kevin Yamauchi

Mechanical Engineering

The Piernas de Vida team partnered with the Vida Nueva Clinic of Prostheses and Orthoses in Choluteca, Honduras to design, plan, and implement a prosthetic foot that could be manufactured entirely by the technicians at the clinic in order to reduce their costs and ultimately allow them to serve more patients each year. Currently, the clinic uses a prefabricated prosthetic lower limb provided by the International Committee of the Red Cross (ICRC) which can be adapted to both transDfemoral and transDtibial patients. The team has successfully developed a foot, currently called the Layer Foot, which can be used by the …


Strider, Eric Johnson, Alex Trask, Ricardo Garcia Jun 2010

Strider, Eric Johnson, Alex Trask, Ricardo Garcia

Mechanical Engineering

No abstract provided.


Medtronic Universal Crimping Machine, Justin Ginochio, Andrew Hanson, Zachary (Zach) Dieterle Jun 2010

Medtronic Universal Crimping Machine, Justin Ginochio, Andrew Hanson, Zachary (Zach) Dieterle

Mechanical Engineering

This project is geared towards the redesign and implementation of a crimping tool for use in the manufacturing of catheters produced by Medtronic Inc. Catheters require two steering cables to maneuver the end of the catheter through the body. The steering cables have a sleeve that is crimped onto their end in order to hold the cable in place inside the catheter steering handle. The current crimping tool, designed by Astro Tool Corp, has a few problems associated with its design. Additionally we are trying to get rid of a step in the manufacturing process that involves the adhesive, cyanoacrylate, …


Edwards Lifesciences: Heart Valve Tension Validation, Lucas Fochler, Alex Mark, Shilpan Shah Jun 2010

Edwards Lifesciences: Heart Valve Tension Validation, Lucas Fochler, Alex Mark, Shilpan Shah

Mechanical Engineering

No abstract provided.


Simulating The Growth Of Articular Cartilage Explants In A Permeation Bioreactor To Aid In Experimental Protocol Design, Timothy P. Ficklin, Andrew Davol, Stephen M. Klisch Apr 2009

Simulating The Growth Of Articular Cartilage Explants In A Permeation Bioreactor To Aid In Experimental Protocol Design, Timothy P. Ficklin, Andrew Davol, Stephen M. Klisch

Mechanical Engineering

Recently a cartilage growth finite element model (CGFEM) was developed to solve nonhomogeneous and time-dependent growth boundary-value problems (Davol et al., 2008, “A Nonlinear Finite Element Model of Cartilage Growth,” Biomech. Model. Mechanobiol., 7, pp. 295–307). The CGFEM allows distinct stress constitutive equations and growth laws for the major components of the solid matrix, collagens and proteoglycans. The objective of the current work was to simulate in vitro growth of articular cartilage explants in a steady-state permeation bioreactor in order to obtain results that aid experimental design. The steady-state permeation protocol induces different types of mechanical stimuli. When the specimen …


A Cartilage Growth Mixture Model With Collagen Remodeling: Validation Protocols, Stephen M. Klisch, Anna Asanbaeva, Sevan R. Oungoulian, Koichi Masuda, Eugene J.-Ma. Thonar, Andrew Davol, Robert L. Sah Jun 2008

A Cartilage Growth Mixture Model With Collagen Remodeling: Validation Protocols, Stephen M. Klisch, Anna Asanbaeva, Sevan R. Oungoulian, Koichi Masuda, Eugene J.-Ma. Thonar, Andrew Davol, Robert L. Sah

Mechanical Engineering

A cartilage growth mixture (CGM) model is proposed to address limitations of a model used in a previous study. New stress constitutive equations for the solid matrix are derived and collagen (COL) remodeling is incorporated into the CGM model by allowing the intrinsic COL material constants to evolve during growth. An analytical validation protocol based on experimental data from a recent in vitro growth study is developed. Available data included measurements of tissue volume, biochemical composition, and tensile modulus for bovine calf articular cartilage (AC) explants harvested at three depths and incubated for 13 days in 20% fetal borine serum …


Articular Cartilage Tensile Integrity: Modulation By Matrix Depletion Is Maturation-Dependent, Anna Asanbaeva, Johnny Tam, Barbara L. Schumacher, Stephen M. Klisch, Koichi Masuda, Robert L. Sah Jun 2008

Articular Cartilage Tensile Integrity: Modulation By Matrix Depletion Is Maturation-Dependent, Anna Asanbaeva, Johnny Tam, Barbara L. Schumacher, Stephen M. Klisch, Koichi Masuda, Robert L. Sah

Mechanical Engineering

Articular cartilage function depends on the molecular composition and structure of its extracellular matrix (ECM). The collagen network (CN) provides cartilage with tensile integrity, but must also remodel during growth. Such remodeling may depend on matrix molecules interacting with the CN to modulate the tensile behavior of cartilage. The objective of this study was to determine the effects of increasingly selective matrix depletion on tensile properties of immature and mature articular cartilage, and thereby establish a framework for identifying molecules involved in CN remodeling. Depletion of immature cartilage with guanidine, chondroitinase ABC, chondroitinase AC, and Streptomyces hyaluronidase markedly increased tensile …


A Growth Mixture Theory For Cartilage With Application To Growth-Related Experiments On Cartilage Explants, Stephen M. Klisch, Silvia S. Chen, Robert L. Sah, Anne Hoger Apr 2003

A Growth Mixture Theory For Cartilage With Application To Growth-Related Experiments On Cartilage Explants, Stephen M. Klisch, Silvia S. Chen, Robert L. Sah, Anne Hoger

Mechanical Engineering

In this paper, we present a growth mixture model for cartilage. The main features of this model are illustrated in a simple equilibrium boundary-value problem that is chosen to illustrate how a mechanical theory of cartilage growth may be applied to growth-related experiments on cartilage explants. The cartilage growth mixture model describes the independent growth of the proteoglycan and collagen constituents due to volumetric mass deposition, which leads to the remodeling of the composition and the mechanical properties of the solid matrix. The model developed here also describes how the material constants of the collagen constituent depend on a scalar …


A Growth Mixture Theory For Cartilage, Stephen M. Klisch, Robert L. Sah, Anne Hoger Nov 2000

A Growth Mixture Theory For Cartilage, Stephen M. Klisch, Robert L. Sah, Anne Hoger

Mechanical Engineering

In this paper we present a model of growth for cartilaginous tissues in which there exists a saturated solid matrix composed of multiple constituents that may grow and remodel independently of each other. Klisch and Hoger recently developed a general theory of volumetric growth for a mixture of ν-1 growing elastic materials and an inviscid fluid, which included a treatment of two special types of internal constraints that are relevant to cartilage. Here, that theory is specialized to construct a cartilage growth model. This theory allows the constituents of the solid matrix to grow independently of each other, and can …


A Special Theory Of Biphasic Mixtures And Experimental Results For Human Annulus Fibrosus Tested In Confined Compression, Stephen M. Klisch, Jeffrey C. Lotz Apr 2000

A Special Theory Of Biphasic Mixtures And Experimental Results For Human Annulus Fibrosus Tested In Confined Compression, Stephen M. Klisch, Jeffrey C. Lotz

Mechanical Engineering

A finite deformation mixture theory is used to quantify the mechanical properties of the annulus fibrosus using experimental data obtained from a confined compression protocol. Certain constitutive assumptions are introduced to derive a special mixture of an elastic solid and an inviscid fluid, and the constraint of intrinsic incompressibility is introduced in a manner that is consistent with results obtained for the special theory. Thirty-two annulus fibrosus specimens oriented in axial (n = 16) and radial (n = 16) directions were obtained from the middle-lateral portion of intact intervertebral discs from human lumbar spines and tested in a stress-relaxation protocol. …