Open Access. Powered by Scholars. Published by Universities.®

Biomechanical Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

California Polytechnic State University, San Luis Obispo

Discipline
Keyword
Publication Year
Publication
Publication Type

Articles 61 - 90 of 103

Full-Text Articles in Biomechanical Engineering

Low-Cost Prosthetic Transfemoral Socket, Emelie Deans, Joshua Ledgerwood, Leah Moore, Shaina Jung, Kristen Temnyk Jun 2016

Low-Cost Prosthetic Transfemoral Socket, Emelie Deans, Joshua Ledgerwood, Leah Moore, Shaina Jung, Kristen Temnyk

Mechanical Engineering

The goal of this senior project was to design and fabricate a low-cost adjustable prosthetic socket for above the knee amputees. This low-cost consideration was incorporated with the original intent to be used in Fiji, however, this changed to the Dominican Republic. It became clear that the need for an adjustable socket was more as a transitional socket. This transitional socket would be used for the first 6 -12 months upon amputation because this when the most amount of volume fluctuation occurs. The project sponsor, LIM Innovations, has already designed the Infinite Socket which contains four main functioning parts: baseplate, …


Prosthetic Socket Cooling System, Benjamin K. Kraw, Kathy Ha, Derek Piastrelli, Cuong Lai Jun 2016

Prosthetic Socket Cooling System, Benjamin K. Kraw, Kathy Ha, Derek Piastrelli, Cuong Lai

Mechanical Engineering

A team of four senior-level undergraduate students in the Interdisciplinary Senior Project Design course in the Engineering Department of California Polytechnic State University: San Luis Obispo have worked to develop a prosthetic socket cooling system, namely for veteran Taylor Morris and exclusively for a transfemoral prosthetic socket, under the Quality of Life+ Laboratory. This cooling system will utilize the thermoelectric effect known as the Peltier effect to transmit heat generated from the residual limb to the surrounding environment by means of forced convection over small aluminum heat sinks. Two measurement devices have also been developed to, one, measure the heat …


The Effects Of Obesity On Resultant Knee Joint Loads For Gait And Cycling, Juan Gutierrez-Franco Jun 2016

The Effects Of Obesity On Resultant Knee Joint Loads For Gait And Cycling, Juan Gutierrez-Franco

Master's Theses

Osteoarthritis (OA) is a degenerative disease of cartilage and bone tissue and the most common form of arthritis, accounting for US$ 10.5 billion in hospital charges in 2006. Obesity (OB) has been linked to increased risk of developing knee OA due to increased knee joint loads and varus-valgus misalignment. Walking is recommended as a weight-loss activity but it may increase risk of knee OA as OB gait increases knee loads. Cycling has been proposed as an alternative weight-loss measure, however, lack of studies comparing normal weight (NW) and OB subjects in cycling and gait hinder identification of exercises that may …


Design And Analysis Of A Lift Assist Walker, Deep P. Shah Mar 2016

Design And Analysis Of A Lift Assist Walker, Deep P. Shah

Master's Theses

Walkers provided stability to the elderly but cannot assist a person from sitting to standing. The objective of this project is to present the design and analysis of a lift assist walker. This report discusses the design and analysis of a collapsible lift assist walker capable of lifting a patient up to 250 lbs. from seated to standing in under 10 seconds. The designed walker utilized a two stage scissor mechanism with a gas spring assisted embedded linear actuator.


Carbon Articulating Backpack Spine, Salvatore Monforte Iii, Darci Lawrence, Savan Patel Dec 2015

Carbon Articulating Backpack Spine, Salvatore Monforte Iii, Darci Lawrence, Savan Patel

Mechanical Engineering

In the field, firefighters and Urban Search and Rescue (USAR) personnel need to transport variable loads efficiently, safely, and comfortably while simultaneously performing certain physical tasks. Current models of external and internal framed backpacks distribute the load of a pack efficiently, but do not allow for the natural movement of the wearer. Wolfpack Gear, Inc. proposed the need for a system which both effectively carries a load and allows for the unhindered natural movement of the user. The goal of this project was to design, build, and test an articulating backpack support system. The first stage of the project comprised …


A Finite Element Analysis Of Tibial Stem Geometry For Total Knee Replacements, Aaron Isidro Bautista Jun 2015

A Finite Element Analysis Of Tibial Stem Geometry For Total Knee Replacements, Aaron Isidro Bautista

Master's Theses

The purpose of this study was to investigate the influence of tibial stem geometry on stress shielding of the tibia for patients with a total knee replacement. Finite element analysis was used to study different tibial stem geometry types, as well as a vast array of different geometric sizes. Both a peg and stem type geometry were analyzed and compared in order to determine what type geometry causes the least amount of stress shielding. A static loading condition with a dynamic loading factor of three was used for the system and the stress responses were analyzed at regions of interest …


Development And Validation Of A Tibiofemoral Joint Finite Element Model And Subsequent Gait Analysis Of Intact Acl And Acl Deficient Individuals, Nicholas Czapla Jun 2015

Development And Validation Of A Tibiofemoral Joint Finite Element Model And Subsequent Gait Analysis Of Intact Acl And Acl Deficient Individuals, Nicholas Czapla

Master's Theses

Osteoarthritis (OA) is a degenerative condition of articular cartilage that affects more than 25 million people in the US. Joint injuries, like anterior cruciate ligament (ACL) tears, can lead to OA due to a change in articular cartilage loading. Gait analysis combined with knee joint finite element modeling (FEM) has been used to predict the articular cartilage loading. To predict the change of articular cartilage loading during gait due to various ACL injuries, a tibiofemoral FEM was developed from magnetic resonance images (MRIs) of a 33 year male, with no prior history of knee injuries. The FEM was validated for …


Sapien3 Comb Stitch Improvement For Edwards Lifesciences, William Harley, Thomas Pluschkell, John Mctigue, Garrett Reed Jun 2015

Sapien3 Comb Stitch Improvement For Edwards Lifesciences, William Harley, Thomas Pluschkell, John Mctigue, Garrett Reed

Mechanical Engineering

The complete senior project report was submitted to the project advisor and sponsor. The results of this project are of a confidential nature and will not be published at this time.


Team Nathan Suspension, Frankie J. Wiggins, Alex D. Seitz, Justin P. Bautista Oct 2014

Team Nathan Suspension, Frankie J. Wiggins, Alex D. Seitz, Justin P. Bautista

Mechanical Engineering

Nathan Cooper is an 8-year old boy with Spinal Muscular Atrophy (SMA). SMA has affected Nathan’s muscle development and requires him to use the Standing Dani™ mobility device. The Standing Dani is a motorized standing wheelchair, or Wheelstand. Nathan controls and uses it to get around. Though the Standing Dani performs well for most functions, it has some distinct issues. The primary issue that this project addresses is its lack of suspension and the discomfort that Nathan feels as a result. After talking with our client, we developed several specifications generally related to geometry, safety, vehicle dynamics, and reliability. Many …


Low-Cost Strider For Guatemala, Nicole Catherine Cooper, Gonzalo Hernandez, Jared W. Tower Jun 2014

Low-Cost Strider For Guatemala, Nicole Catherine Cooper, Gonzalo Hernandez, Jared W. Tower

Mechanical Engineering

The purpose of this project was to create a strider, a type of standing rehabilitation device, for children in developing countries who have trouble walking and supporting their full body weight. The project was initially brought to us by Cal Poly professor Brian Self, who had visited a clinic in San Marcos and determined that there were children there who had difficulties with walking and were a need for a rehabilitation device. The team discussed the problem with Dr. Self, Matt Robinson (a local San Luis Obispo prosthetist), and Cal Poly physics professor Pete Schwartz, all of whom had visited …


2d Wireform Process Improvement, Katy Conlin, Carlo Ebora, Jordan Gamble Jun 2014

2d Wireform Process Improvement, Katy Conlin, Carlo Ebora, Jordan Gamble

Mechanical Engineering

The body of this work has been created for Edwards Lifesciences in conjunction with senior project requirements. As such, the information produced and contained within is under a non‐disclosure agreement. As per request by sponsor, the body of the work will not be submitted to any outside parties, and the title page will serve as proof of completion.


Semi-Automated Method Of Assembly For Physio Ii Ring, Cameron Anderson Deines, Kelsey Jean Engel, Christopher Kiuyen Wong Jun 2014

Semi-Automated Method Of Assembly For Physio Ii Ring, Cameron Anderson Deines, Kelsey Jean Engel, Christopher Kiuyen Wong

Mechanical Engineering

No abstract provided.


Folding Wheelchair Improvement, Matthew Edison Grace, Kevin Alan Miyamoto, Andrey Lee Oliveira Jun 2014

Folding Wheelchair Improvement, Matthew Edison Grace, Kevin Alan Miyamoto, Andrey Lee Oliveira

Mechanical Engineering

No abstract provided.


Development And Validation Of A Human Knee Joint Finite Element Model For Tissue Stress And Strain Predictions During Exercise, Spencer D. Wangerin Dec 2013

Development And Validation Of A Human Knee Joint Finite Element Model For Tissue Stress And Strain Predictions During Exercise, Spencer D. Wangerin

Master's Theses

Osteoarthritis (OA) is a degenerative condition of cartilage and is the leading cost of disability in the United States. Motion analysis experiments in combination with knee-joint finite element (FE) analysis may be used to identify exercises that maintain knee-joint osteochondral (OC) loading at safe levels for patients at high-risk for knee OA, individuals with modest OC defects, or patients rehabilitating after surgical interventions. Therefore, a detailed total knee-joint FE model was developed by modifying open-source knee-joint geometries in order to predict OC tissue stress and strain during the stance phase of gait. The model was partially validated for predicting the …


Development And Validation Of A Human Hip Joint Finite Element Model For Tissue Stress And Strain Predictions During Gait, Jeffrey D. Pyle Dec 2013

Development And Validation Of A Human Hip Joint Finite Element Model For Tissue Stress And Strain Predictions During Gait, Jeffrey D. Pyle

Master's Theses

Articular cartilage degeneration, called osteoarthritis, in the hip joint is a serious condition that affects millions of individuals yearly, with limited clinical solutions available to prevent or slow progression of damage. Additionally, the effects of high-risk factors (e.g. obesity, soft and hard tissue injuries, abnormal joint alignment, amputations) on the progression of osteoarthritis are not fully understood. Therefore, the objective of this thesis is to generate a finite element model for predicting osteochondral tissue stress and strain in the human hip joint during gait, with a future goal of using this model in clinically relevant studies aimed at prevention, treatment, …


Finite Element Models Of The Knee & Hip Joints: Using Opensim To Predict Muscle Forces, Kevin S. Jones, Spencer D. Wangerin, Jeffrey D. Pyle, Stephen M. Klisch, Scott J. Hazelwood Aug 2013

Finite Element Models Of The Knee & Hip Joints: Using Opensim To Predict Muscle Forces, Kevin S. Jones, Spencer D. Wangerin, Jeffrey D. Pyle, Stephen M. Klisch, Scott J. Hazelwood

STAR Program Research Presentations

Quantitative data of stresses and strains in the cartilage of the knee and hip joints are required to design prostheses and can be used to give accurate advice to patients with cartilage damage as to which activities should be avoided. Instrumented hip implants can only give the overall resultant force in the joint, not the stresses and strains throughout the cartilage. Finite Element (FE) models of the Knee and Hip are being constructed in order to obtain the stresses and strains in articular (of the joint) cartilage. Muscle forces and joint contact forces are required as inputs to these FE …


Guidance System, Kayaking For The Visually Impaired, D. Ryan Kirtland, Ryan Phife, William Gardner, Amy Johnson Jun 2013

Guidance System, Kayaking For The Visually Impaired, D. Ryan Kirtland, Ryan Phife, William Gardner, Amy Johnson

Biomedical Engineering

Quality Life Plus is working with Team River Runner to develop an assistive guidance system for veterans who want to remain active by kayaking, after sustaining an injury that impairs vision. This system allows these veterans to complete a slalom speed race independent of a personal guide in the water. The system incorporates 3 stations that each contain a speaker connected to a microcontroller system covered by a Pelican Case on a custom made buoy. During the slalom race, a kayaker will travel from shore towards buoy #1 as it omits sound from the speaker. As the kayaker moves around …


Intuity Sleeve Redesign, Maxwell Arnold, Brittany Kinkade, Dominic Nicoletti Jun 2013

Intuity Sleeve Redesign, Maxwell Arnold, Brittany Kinkade, Dominic Nicoletti

Mechanical Engineering

No abstract provided.


Adaptive Floor Hockey Device, Chris Gaul, Ricardo Gaytan, Matt Spaulding, Shannon Brant Jun 2013

Adaptive Floor Hockey Device, Chris Gaul, Ricardo Gaytan, Matt Spaulding, Shannon Brant

Mechanical Engineering

Sean is a young boy living with ataxic cerebral palsy. Ataxic cerebral

palsy affects Sean’s balance and coordination, so he uses a walker to

increase his mobility. Sean would like to play Special Olympics Floor

Hockey but his walker prevents him from participating. The goal of this

Senior project was to develop a device to be attached to his previous

walker to allow Sean to play floor hockey in the least restrictive

environment possible. The Adaptive Floor Hockey Device is the product

we designed to satisfy this need.


Design And Development Of A Stair Ascension Assistive Device For Transfemoral Amputees, Casey Michael Barbarino Jun 2013

Design And Development Of A Stair Ascension Assistive Device For Transfemoral Amputees, Casey Michael Barbarino

Master's Theses

Transfemoral amputees around the world experience increased difficulty in climbing stairs due to lack of muscle, balance, and other factors. The loss of a lower limb greatly diminishes the amount of natural force generation provided that is necessary to propel oneself up stairs. This study investigated possible solutions to the problem of stair ascension for transfemoral amputees by the means of designing and developing an externally attachable device to a prosthesis. The number of amputations from military service has greatly increased since 2008, which shows there is a clear need for assistive devices (Wenke, Krueger, & Ficke, 2012). With the …


Design And Testing Of A Low Cost Prosthetic Foot, Shalan Ertis, John Kearns, Seija Maniskas Jun 2012

Design And Testing Of A Low Cost Prosthetic Foot, Shalan Ertis, John Kearns, Seija Maniskas

Mechanical Engineering

No abstract provided.


Viscoelastic Anisotropic Finite Element Mixture Model Of Articular Cartilage Using Viscoelastic Collagen Fibers And Validation With Stress Relaxation Data, Matthew Alexander Griebel Jun 2012

Viscoelastic Anisotropic Finite Element Mixture Model Of Articular Cartilage Using Viscoelastic Collagen Fibers And Validation With Stress Relaxation Data, Matthew Alexander Griebel

Master's Theses

Experimental results show that collagen fibers exhibit stress relaxation under tension and a highly anisotropic distribution. To further develop the earlier model of Stender [1], the collagen constituent was updated to reflect its intrinsic viscoelasticity and anisotropic distribution, and integrated with an existing mixture model with glycosaminoglycans and ground substance matrix. A two-term Prony series expansion of the quasi-linear viscoelastic model was chosen to model the viscoelastic properties of the collagen fibers. Material parameters were determined by using the simplex method to minimize the sum of squared errors between model results and experimental stress relaxation data of tissue in tension. …


Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser Jun 2012

Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser

Mechanical Engineering

Amputations are a common occurrence in soldiers returning home who have suffered the effects of IED and munitions explosions. For upper limb amputees, trans-radial amputations are the most common. Traditional hook devices do not offer an adequate level of normalcy for users, prompting the use of myoelectric devices. While current myoelectric devices do offer a more natural experience, they come with a host of other problems that makes their adoption by service personnel not desirable or not permitted by the VA. PolyGrasp Reach seeks to reduce weight and cost and improve performance. This addresses several of the issues with devices …


Hydraulically Driven Mechanical Representation Of A Biological System, Andrea Argouarch, Michael Mceachern, Brandon Parham Jun 2012

Hydraulically Driven Mechanical Representation Of A Biological System, Andrea Argouarch, Michael Mceachern, Brandon Parham

Biomedical Engineering

No abstract provided.


Prediction Of Articular Cartilage Remodeling During Dynamic Compression With A Finite Element Model, Kevin Akira Yamauchi Jun 2012

Prediction Of Articular Cartilage Remodeling During Dynamic Compression With A Finite Element Model, Kevin Akira Yamauchi

Master's Theses

First, an in vitro growth experiment was performed to test the hypothesis that applying dynamic unconfined compression during culture produces het- erogeneous remodeling in newborn bovine articular cartilage explants. Het- erogeneous measures of cartilage microstructure were obtained by biochemical assays and quantified polarized light microscopy. Significant differences were measured between the GAG content in the inner and outer portions of the sam- ples stimulated with dynamic unconfined compression. The COL fiber network was found to be more highly aligned in the inner portion of the sample than in the peripheral region.

Next, a poroelastic finite element model with a remodeling …


Access|Closure Balloon Catheter Redesign Project, Keenan Bamburg, Yvette Castillo, Elizabeth Eskildsen Dec 2011

Access|Closure Balloon Catheter Redesign Project, Keenan Bamburg, Yvette Castillo, Elizabeth Eskildsen

Mechanical Engineering

No abstract provided.


Challenger J Hockey Prosthesis Final Design Report, Ryan Bakker, Spencer Noe, Christopher Perkins Dec 2011

Challenger J Hockey Prosthesis Final Design Report, Ryan Bakker, Spencer Noe, Christopher Perkins

Mechanical Engineering

The content of this report is withheld as confidential. QL+ is the owner of the intellectual property created throughout the duration of this project. Dr. Tom Mase (mechanical engineering) maintains a full copy of the report and intends to disseminate it upon completion of the necessary intellectual property protection measures.


Golf Prosthesis Final Design Report, Joseph Barcus, Lauren Wilson, Ryan Satcher Dec 2011

Golf Prosthesis Final Design Report, Joseph Barcus, Lauren Wilson, Ryan Satcher

Mechanical Engineering

A prosthetic attachment designed to allow an upper extremity bilateral amputee to golf.


Rock-N-Bowler Ii, Josh Grip, Travis Rodrigues, Richard Rozporka Jun 2011

Rock-N-Bowler Ii, Josh Grip, Travis Rodrigues, Richard Rozporka

Mechanical Engineering

The report of the creation of an adaptive bowling device designed for people in powered wheelchairs. The basic design is a ramp that attaches to the wheelchair and has the ability to add spin to the ball to allow the user to hook the ball.


Poroelastic Finite Element Analysis Of A Heterogeneous Articular Cartilage Explant Under Dynamic Compression In Abaqus, Kelsey Kiyo Kam Jun 2011

Poroelastic Finite Element Analysis Of A Heterogeneous Articular Cartilage Explant Under Dynamic Compression In Abaqus, Kelsey Kiyo Kam

Master's Theses

A poroelastic finite element model of a heterogeneous articular cartilage disc was

created to examine the tissue response to low amplitude (± 2% strain), low

frequency (0.1 Hz) dynamic unconfined compression (UCC). A strong correlation

has been made between the relative fluid velocity and stimulation of

glycosaminoglycan synthesis. A contour plot of the model shows the relative fluid

velocity during compression exceeds a trigger value of 0.25 μm/s at the radial

periphery. Dynamic UCC biochemical results have also reported a higher

glycosaminoglycan content in this region versus that of day 0 specimens. Fluid

velocity was also found not to be …