Full-Text Articles in Biomechanical Engineering

Cfd Simulation Of The Thermal Performance Of A Parallel Counter-Parallel Flow Heat Exchanger For The Treatment Of Hypothermia, Alex Heller Aug 2014

Cfd Simulation Of The Thermal Performance Of A Parallel Counter-Parallel Flow Heat Exchanger For The Treatment Of Hypothermia, Alex Heller

UNLV Theses, Dissertations, Professional Papers, and Capstones

Hypothermia is a life-threatening condition. Currently, active warming methods are the most effective treatment for dysthermic patients. The aim of this study is to investigate the use of computational fluid dynamics (CFD) in evaluating the thermal performance of a parallel/counter-parallel flow heat exchanger used as part of a fluid warmer to treat Hypothermia. The 3D model of the heat exchanger is divided into three regions; Infusate (fluid to be heated), Hot Water (heating fluid), and a Solid Region (wall). At the end of the heat exchanger, an elbow section is used to create the counter-parallel flow arrangement specific to this …


Design And Development Of A Stair Ascension Assistive Device For Transfemoral Amputees, Casey Michael Barbarino Jun 2013

Design And Development Of A Stair Ascension Assistive Device For Transfemoral Amputees, Casey Michael Barbarino

Master's Theses

Transfemoral amputees around the world experience increased difficulty in climbing stairs due to lack of muscle, balance, and other factors. The loss of a lower limb greatly diminishes the amount of natural force generation provided that is necessary to propel oneself up stairs. This study investigated possible solutions to the problem of stair ascension for transfemoral amputees by the means of designing and developing an externally attachable device to a prosthesis. The number of amputations from military service has greatly increased since 2008, which shows there is a clear need for assistive devices (Wenke, Krueger, & Ficke, 2012). With the …


Design And Testing Of Novel Mouthguard With Intermediate Nitinol And Foam Layers, Adam Kessler May 2013

Design And Testing Of Novel Mouthguard With Intermediate Nitinol And Foam Layers, Adam Kessler

UNLV Theses, Dissertations, Professional Papers, and Capstones

It is the aim of this study to investigate a novel mouthguard design that incorporates the use of a nickel-titanium (Nitinol) layer and thin foam layer in addition to EVA layers. It is thought that the Nitinol layer can distribute the force of an impact and that the thin foam layer may absorb this distributed force better than a solid EVA mouthguard of the same thickness. Rectangular, flat coupons representative of several mouthguard configurations were constructed for testing using an instrumented drop-weight impact tower. The coupon configurations include a control made of laminated EVA, a group of laminated EVA and …


Closed Loop Control Of A Cylindrical Tube Type Ionic Polymer Metal Composite (Ipmc), Benjamin Mead May 2013

Closed Loop Control Of A Cylindrical Tube Type Ionic Polymer Metal Composite (Ipmc), Benjamin Mead

UNLV Theses, Dissertations, Professional Papers, and Capstones

The goal of this research is to provide a framework for the integration of tube type, cylindrical Ionic Polymer Metal-Composite (IPMC) into conventional devices. IPMCs are one of the most widely used types of electro-active polymer actuator, due to their low electric driving potential and large deformation range. For this research a tube type IPMC was investigated. This IPMC has a circular cross section with four separate electrodes on its surface and a hole through the middle. The four electrodes allow for biaxial bending and accurate control of the tip location. One of the main advantages of using this type …


Design, Analysis And Testing Of Haptic Feedback System For Laparoscopic Graspers In In Vivo Surgical Robots, Nikhil Salvi Jul 2012

Design, Analysis And Testing Of Haptic Feedback System For Laparoscopic Graspers In In Vivo Surgical Robots, Nikhil Salvi

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Laparo-Endoscopic Single Site (LESS) Robotics Surgery is an advanced technology in the field of Minimally Invasive Surgery (MIS). The LESS surgical robots significantly improve the surgeon’s accuracy, dexterity and visualization, and reduce the invasiveness of surgical procedure results in faster recovery time and improved cosmetic results. In a standard robotic endosurgery, the palpation of tissues is performed by laparoscopic graspers located at the end effectors. The master-slave configuration in robotic surgery leads in remote access to the operation site. Therefore, surgeon’s ability to perceive valuable sensory information is severely diminished. Sensory information such as haptics, which is essential for safe …


Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser Jun 2012

Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser

Mechanical Engineering

Amputations are a common occurrence in soldiers returning home who have suffered the effects of IED and munitions explosions. For upper limb amputees, trans-radial amputations are the most common. Traditional hook devices do not offer an adequate level of normalcy for users, prompting the use of myoelectric devices. While current myoelectric devices do offer a more natural experience, they come with a host of other problems that makes their adoption by service personnel not desirable or not permitted by the VA. PolyGrasp Reach seeks to reduce weight and cost and improve performance. This addresses several of the issues with devices …


Effect Of Extracellular Matrix (Ecm) Protein Micropatterns On The Behavior Of Human Neuroblastoma Cells, Ishwari Poudel Dec 2011

Effect Of Extracellular Matrix (Ecm) Protein Micropatterns On The Behavior Of Human Neuroblastoma Cells, Ishwari Poudel

Department of Engineering Mechanics: Dissertations, Theses, and Student Research

Recent advances in patterning techniques and emerging surface microtechnologies have allowed cell micropatterning to control spatial location of the cells on a surface as well as cell shape, attachment area, and number of contacting neighbor cells. These parameters play important roles in cell cellular behaviors. Cell micropatterning has thus become one of the most important strategies for biomedical applications, such as, tissue engineering, diagnostic immunoassays, lab-on-chip devices, bio-sensing, etc., and cell biology studies as well. For neuronal cells, there have been attempts to distribute neuronal cells on specific patterns to control cell-to-cell interaction. However, there have been very limited understanding …


Ros-Drill Automation: Visual Feedback Control And Rotational Motion Tracking, Jhon F. Diaz Aug 2011

Ros-Drill Automation: Visual Feedback Control And Rotational Motion Tracking, Jhon F. Diaz

Master's Theses

ICSI (intra-cytoplasmic sperm injection) has attracted research interest from both biological and engineering groups. The technology is constantly evolving to perform this procedure with precision and speed. One such development is the contribution of this thesis. We focus on a relatively recent procedure called Ros-Drill© (rotationally oscillating drill), of which the early versions have already been effectively utilized for the mice. In the first part, we present a procedure to automate a critical part of the operation: initiation of the rotational oscillation, Visual feedback is used to track the pipette tip. Predetermined species-specific penetration depth is successfully utilized …


Gas Embolic Factors In Cardiovascular Health, Eric L. Cutler Apr 2011

Gas Embolic Factors In Cardiovascular Health, Eric L. Cutler

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Gas emboli are a clinical issue often encountered in the space exploration, marine construction, and medical fields.  Individuals involved with these disciplines will often have asympomatic gas emboli circulating throughout their bodies on a regular basis.  A study into the impact of chronic asymptomatic gas emboli on the risk of atherosclerosis in humans is thus presented.  This research utilized a custom built cardiovascular flow simulator and accompanying data acquisition system to experimentally determine the influence of gas emboli under varied circumstances on the mean wall shear stress of a tube in-vitro.  A directly inverse relationship between gas embolus presence in …


Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jun 2010

Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. Following a laryngectomy, some people speak using an electrolarynx which replaces the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the buzzing monotonic sound emitted, the need for a free hand to operate the device, and difficulty experienced by many laryngectomees in adapting to its use. Despite these shortcomings, it remains the preferred method of speech rehabilitation for a substantial minority of laryngectomees. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal …


An Analysis Of The Performance Of Foams Used In Hurling Helmets, Keith Norris, Stephen Tiernan May 2008

An Analysis Of The Performance Of Foams Used In Hurling Helmets, Keith Norris, Stephen Tiernan

Conference Papers

Abstract Head injuries can occur in most sporting activities. The seriousness of these injuries can vary greatly depending on the sport. Many sports such as American football, cricket, baseball and hurling try to reduce this risk by designing helmets that are suitable to be worn by the players. The National Standard Authority of Ireland (NSAI) has recently made great strides in this area with the introduction of the first comprehensive standard adopted for the sport I.S. 355:2006, which sets out new testing procedures that all new helmets must meet. The Gaelic Athletic Association (GAA) has also stated its intention to …