Open Access. Powered by Scholars. Published by Universities.®

Signal Processing Commons

Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering

Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 61 - 81 of 81

Full-Text Articles in Signal Processing

Multi-Channel Analysis For Gradient Artifact Removal From Concurrent Eeg-Fmri Studies, Miguel R. Castellanos, Zhongming Liu Aug 2014

Multi-Channel Analysis For Gradient Artifact Removal From Concurrent Eeg-Fmri Studies, Miguel R. Castellanos, Zhongming Liu

The Summer Undergraduate Research Fellowship (SURF) Symposium

Concurrent electroencephalogram (EEG) and functional magnetic resonance imaging (fMRI) recordings are susceptible to large amounts of noise due to the static and dynamic magnetic fields present inside the MR scanner. EEG-fMRI studies are conducted to provide better spatial and temporal resolution for each recording, respectively, but the artifacts found in the EEG render the data impossible to interpret. Past studies have focused on signal post-processing techniques which are able to effectively remove noise upon the completion of a study, but there are no techniques able to process the data in real-time without extensive calibration. This research addresses this issue by …


Design, Characterization And Application Of A Multiple Input Stethoscope Apparatus, Spencer Geng Wong Aug 2014

Design, Characterization And Application Of A Multiple Input Stethoscope Apparatus, Spencer Geng Wong

Master's Theses

For this project, the design, implementation, characterization, calibration and possible applications of a multiple transducer stethoscope apparatus were investigated. The multi-transducer sensor array design consists of five standard stethoscope diaphragms mounted to a rigid frame for a-priori knowledge of their relative spatial locations in the x-y plane, with compliant z-direction positioning to ensure good contact and pressure against the subject’s skin for reliable acoustic coupling. When this apparatus is properly placed on the body, it can digitally capture the same important body sounds investigated with standard acoustic stethoscopes; especially heart sounds. Acoustic signal inputs from each diaphragm are converted to …


Clear Circuit Contact Lens, Paul Hecker Ii, Phillip Azar, Alexander Do, Benny Ng, Errol Leon Jun 2014

Clear Circuit Contact Lens, Paul Hecker Ii, Phillip Azar, Alexander Do, Benny Ng, Errol Leon

Electrical Engineering

The clear active contact lens project aims to address safety and hazard awareness with an unexplored field of eye wear technology. With advancements in nanotechnology and the advent of circuits on contact lens, this project is one of the first research and development into this new field, following University of Washington and Google. The team focuses on the safety and biocompatibility of the contact lens for a comfortable ease of use. The designs push the limits of thin film printed technology with its pursuit of fine designs of 250μm antennas. The project streamlines the manufacturing process for a combination substrate …


Quantized Nonnegative Matrix Factorization, Ruairí De Fréin Jan 2014

Quantized Nonnegative Matrix Factorization, Ruairí De Fréin

Conference papers

Even though Nonnegative Matrix Factorization (NMF) in its original form performs rank reduction and signal compaction implicitly, it does not explicitly consider storage or transmission constraints. We propose a Frobenius-norm Quantized Nonnegative Matrix Factorization algorithm that is 1) almost as precise as traditional NMF for decomposition ranks of interest (with in 1-4dB), 2) admits to practical encoding techniques by learning a factorization which is simpler than NMF’s (by a factor of 20-70) and 3) exhibits a complexity which is comparable with state-of-the-art NMF methods. These properties are achieved by considering the quantization residual via an outer quantization optimization step, in …


A Method For Non-Invasive, Automated Behavior Classification In Mice, Using Piezoelectric Pressure Sensors, Steven R. Gooch Jan 2014

A Method For Non-Invasive, Automated Behavior Classification In Mice, Using Piezoelectric Pressure Sensors, Steven R. Gooch

Theses and Dissertations--Electrical and Computer Engineering

While all mammals sleep, the functions and implications of sleep are not well understood, and are a strong area of investigation in the research community. Mice are utilized in many sleep studies, with electroencephalography (EEG) signals widely used for data acquisition and analysis. However, since EEG electrodes must be surgically implanted in the mice, the method is high cost and time intensive. This work presents an extension of a previously researched high throughput, low cost, non-invasive method for mouse behavior detection and classification. A novel hierarchical classifier is presented that classifies behavior states including NREM and REM sleep, as well …


Independent Component Analysis Enhancements For Source Separation In Immersive Audio Environments, Yue Zhao Jan 2013

Independent Component Analysis Enhancements For Source Separation In Immersive Audio Environments, Yue Zhao

Theses and Dissertations--Electrical and Computer Engineering

In immersive audio environments with distributed microphones, Independent Component Analysis (ICA) can be applied to uncover signals from a mixture of other signals and noise, such as in a cocktail party recording. ICA algorithms have been developed for instantaneous source mixtures and convolutional source mixtures. While ICA for instantaneous mixtures works when no delays exist between the signals in each mixture, distributed microphone recordings typically result various delays of the signals over the recorded channels. The convolutive ICA algorithm should account for delays; however, it requires many parameters to be set and often has stability issues. This thesis introduces the …


The Presence Of Regional Accents In Electrolarynx Speech And The Resultant Effect On Overall Intelligibility., Brian Madden, Eugene Coyle Apr 2012

The Presence Of Regional Accents In Electrolarynx Speech And The Resultant Effect On Overall Intelligibility., Brian Madden, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, a phonological analysis of a section of results from an online perceptual intelligibility test was performed which compared speech produced using a novel hands-free electrolarynx and a commercially available electrolarynx. A portion of the test consisted of a closed-set format containing a selection of four sets of four random CVC audio samples …


Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jan 2011

Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, the intelligibility of speech produced using a novel hands-free actuator is compared to speech produced using a conventional electrolarynx. Two able-bodied speakers (one male, one female) performed a closed response test containing 28 monosyllabic words, once using a conventional electrolarynx and a second time using the novel design. The resulting audio recordings …


Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle Jan 2011

Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx acts as the sound source, providing a quasi-periodic excitation of the vocal tract. Following a total laryngectomy, some people speak using an electrolarynx which employs an electromechanical actuator to perform the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the monotonic sound emitted, the need for a free-hand to operate the device, and the difficulty experienced by many laryngectomees in adapting to its use. One improvement to the electrolarynx, which clinicians and users frequently suggest, is the provision of a convenient hands-free control facility. This would allow more natural use of …


On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle Jan 2011

On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle

Conference Papers

Eye tracking is a well-established method of computer control for profoundly paralysed people (Anson et al., 2002). Cameras are commonly used to track eye movements (Morimoto et al., 2005) but one alternative is the bioelectrical signal known as the electrooculogram (EOG). There are some EOG mouse control systems that facilitate the use of GUI applications, but certain actions, which are straightforward using a conventional mouse, remain impossible. Unless the eyes are tracking a target, they move in saccades (jumps), making it impossible to voluntarily trace out smooth trajectories with one's gaze, as would be required to draw a smooth curve. …


Multi-Frequency Processing For Lumen Enhancement With Wideband Intravascular Ultrasound, Rory A. Carrillo Sep 2010

Multi-Frequency Processing For Lumen Enhancement With Wideband Intravascular Ultrasound, Rory A. Carrillo

Master's Theses

The application of high frequency ultrasound is the key to higher resolution intravascular ultrasound (IVUS) images. The need to further improve the IVUS spatial resolution may drive the transducer center frequency even higher than the current 40 MHz range. However, increasing the center frequency may be challenging as it leads to stronger scattering echoes from blood. The high level of blood scattering echoes may obscure the arterial lumen and make image interpretation difficult. Blood backscatter levels increase with transmission center frequency at a much greater rate compared to arterial tissue. These different frequency dependencies provide a potential method to distinguish …


Application Of Signal Advance Technology To Electrophysiology, Chris M. Hymel Aug 2010

Application Of Signal Advance Technology To Electrophysiology, Chris M. Hymel

Dissertations and Theses (Open Access)

Medical instrumentation used in diagnosis and treatment relies on the accurate detection and processing of various physiological events and signals. While signal detection technology has improved greatly in recent years, there remain inherent delays in signal detection/ processing. These delays may have significant negative clinical consequences during various pathophysiological events. Reducing or eliminating such delays would increase the ability to provide successful early intervention in certain disorders thereby increasing the efficacy of treatment.

In recent years, a physical phenomenon referred to as Negative Group Delay (NGD), demonstrated in simple electronic circuits, has been shown to temporally advance the detection of …


Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jun 2010

Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. Following a laryngectomy, some people speak using an electrolarynx which replaces the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the buzzing monotonic sound emitted, the need for a free hand to operate the device, and difficulty experienced by many laryngectomees in adapting to its use. Despite these shortcomings, it remains the preferred method of speech rehabilitation for a substantial minority of laryngectomees. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal …


Time-Frequency Analysis Of Intracardiac Electrogram, Erik Brockman Jun 2009

Time-Frequency Analysis Of Intracardiac Electrogram, Erik Brockman

Master's Theses

The Cardiac Rhythm Management Division of St. Jude Medical specializes in the development of implantable cardioverter defibrillators that improve the quality of life for patients diagnosed with a variety of cardiac arrhythmias, especially for patients prone to sudden cardiac death. With the goal to improve detection of cardiac arrhythmias, this study explored the value in time-frequency analysis of intracardiac electrogram in four steps. The first two steps characterized, in the frequency domain, the waveforms that construct the cardiac cycle. The third step developed a new algorithm that putatively provides the least computationally expensive way to identifying cardiac waveforms in the …


A Mobile Ecg Monitoring System With Context Collection, Jin Peng Li, Damon Berry, Richard Hayes Jan 2009

A Mobile Ecg Monitoring System With Context Collection, Jin Peng Li, Damon Berry, Richard Hayes

Conference Papers

Preventative health management represents a shift from the traditional approach of reactive treatment-based healthcare towards a proactive wellness-management approach where patients are encouraged to stay healthy with expert support when they need it, at any location and any time. This work represents a step along the road towards proactive, preventative healthcare for cardiac patients. It seeks to develop a smart mobile ECG monitoring system that requests and records context information about what is happening around the subject when an arrhythmia event occurs. Context information about the subject’s activities of daily living will, it is hoped, provide an enriched data set …


Least Squares Support Vector Machine Based Classification Of Abnormalities In Brain Mr Images, S. Thamarai Selvi, D. Selvathi, R. Ramkumar, Henry Selvaraj Mar 2006

Least Squares Support Vector Machine Based Classification Of Abnormalities In Brain Mr Images, S. Thamarai Selvi, D. Selvathi, R. Ramkumar, Henry Selvaraj

Electrical & Computer Engineering Faculty Research

The manual interpretation of MRI slices based on visual examination by radiologist/physician may lead to missing diagnosis when a large number of MRIs are analyzed. To avoid the human error, an automated intelligent classification system is proposed. This research paper proposes an intelligent classification technique to the problem of classifying four types of brain abnormalities viz. Metastases, Meningiomas, Gliomas, and Astrocytomas. The abnormalities are classified based on Two/Three/ Four class classification using statistical and textural features. In this work, classification techniques based on Least Squares Support Vector Machine (LS-SVM) using textural features computed from the MR images of patient are …


Applications Of Wavelet Transforms In Biomedical Optoacoustics, Zibiao Wei, Shujun Yang, Amin N. Dharamsi, Barbara Hargrave Jan 2000

Applications Of Wavelet Transforms In Biomedical Optoacoustics, Zibiao Wei, Shujun Yang, Amin N. Dharamsi, Barbara Hargrave

Biological Sciences Faculty Publications

We discuss the utility of wavelet transform methods in signal processing in general, and in particular, demonstrate the technique in optoacoustic applications. In several optoacoustic experiments with different samples, we have successfully enhanced the signal to noise ratios. Wavelet transforms optimize resolution by utilizing a tailored, variable time-window in different frequency regions. The technique's great advantage lies in the fact that the wavelet transform adds some redundancy to the original signal, and some desired features can be enhanced in the transformed space. In addition, proper choice of the basis set allows a sparse representation of the signal. Therefore, even when …


Computer Aided Detection Of Microcalcifications Utilizing Texture Analysis, Ronald C. Dauk Dec 1995

Computer Aided Detection Of Microcalcifications Utilizing Texture Analysis, Ronald C. Dauk

Theses and Dissertations

A comparative study of texture measures for the classification of breast tissue is presented. The texture features investigated include Angular Second Moments, Power Spectrum Analysis and a novel feature, Laws Energy Ratios. The texture study was accomplished as part of the development of a Model Based Vision (MBV) system for the automatic detection of microcalcifications. An overview of the Microcalcification Detection System is presented, which applies image differencing techniques, feature selection methods, and neural networks for locating microcalcification clusters in mammograms. The Power Spectrum Analysis feature set had the best overall performance with an 83% Probability of Detection and an …


Three Dimensional Localization Of Lesions From Digitized Mammograms, Amy L. Magnus Dec 1995

Three Dimensional Localization Of Lesions From Digitized Mammograms, Amy L. Magnus

Theses and Dissertations

This thesis describes new algorithms to localize regions-of-interests (ROIs) three dimensionally from a pair of digitized mammograms. This work is intended to add a layer of sophistication to computer aided diagnosis by putting to use the fixed and measurable parameters of mammographic imaging. The fixed parameters are the source to film orientation and the podium-image distance. Measurable parameters are the rotation angle of the x-ray tube from the horizontal and the compression depth (the distance from compression paddle to contact podium distance) at the time of imaging. As an additional benefit, three dimensional localization algorithms alleviate the confusion radiologists may …


Fetal Heart Rate Detection With A Passive Acoustic Sensor System, Zongyao Zhou Apr 1995

Fetal Heart Rate Detection With A Passive Acoustic Sensor System, Zongyao Zhou

Electrical & Computer Engineering Theses & Dissertations

Research and development is presented of real time signal processing methodologies for the detection of fetal heart tones from noise contaminated signals obtained from passive acoustic sensors. A nonlinear Teager energy operator is utilized for detection of the fetal heart tone event. Autocorrelation and a parallel redundancy correction algorithm derives fetal heart rates. A real time monitoring system is described which records and plots the time history of both the fetal heart rate and the acoustic fetal heart signal. The system is validated in the context of the fetal nonstress test. Comparisons are made with ultrasonic nonstress tests on a …


Signal Processing Methodologies For An Acoustic Fetal Heart Rate Monitor, Robert A. Pretlow Iii Apr 1991

Signal Processing Methodologies For An Acoustic Fetal Heart Rate Monitor, Robert A. Pretlow Iii

Electrical & Computer Engineering Theses & Dissertations

Research and development is presented of real time signal processing methodologies for the detection of fetal heart tones within a noise-contaminated signal from a passive acoustic sensor. A linear predictor algorithm is utilized for detection of the heart tone event and additional processing derives heart rate. The linear predictor is adaptively "trained" in a least mean square error sense on generic fetal heart tones recorded from patients. A real time monitor system is described which outputs to a strip chart recorder for plotting the time history of the fetal heart rate. The system is validated in the context of the …