Open Access. Powered by Scholars. Published by Universities.®
Other Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Biomedical Devices and Instrumentation (37)
- Mechanical Engineering (15)
- Medicine and Health Sciences (14)
- Biomechanics and Biotransport (12)
- Bioimaging and Biomedical Optics (11)
-
- Electrical and Computer Engineering (11)
- Life Sciences (11)
- Biological Engineering (10)
- Biomaterials (10)
- Molecular, Cellular, and Tissue Engineering (10)
- Bioelectrical and Neuroengineering (9)
- Biomechanical Engineering (9)
- Biomedical (9)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (7)
- Diseases (7)
- Cardiovascular Diseases (5)
- Physiology (5)
- Systems and Integrative Engineering (5)
- Medical Sciences (4)
- Other Electrical and Computer Engineering (4)
- Cellular and Molecular Physiology (3)
- Computer Engineering (3)
- Diagnosis (3)
- Electrical and Electronics (3)
- Manufacturing (3)
- Other Mechanical Engineering (3)
- Physical Sciences and Mathematics (3)
- Keyword
-
- Arteriogenesis (9)
- Ischemia (7)
- Device (4)
- Endothelial Dysfunction (4)
- Microfluidics (4)
-
- Vasodilation (4)
- Angiogenesis (3)
- Collateral circulation (3)
- Diagnostics (3)
- Mouse (3)
- Osteoporosis (3)
- Peripheral arterial occlusive disease (3)
- 3D printing (2)
- Aptamer (2)
- Bone Remodeling (2)
- Calibrated Cuff Plethysmography (2)
- Cardiovascular Disease (2)
- Cell transplantation (2)
- Cold-Water Immersion (2)
- Computational (2)
- Diabetes (2)
- FEA (2)
- Filtration (2)
- Finite Element Analysis (2)
- Isoelectric Focusing (2)
- Learning (2)
- MRI (2)
- Medical device (2)
- Microfluidic (2)
- Myoblast (2)
- Publication Year
- Publication
- Publication Type
Articles 91 - 110 of 110
Full-Text Articles in Other Biomedical Engineering and Bioengineering
Evaluation Of Decellularization Procedures For Porcine Arteries, Charles Clapp
Evaluation Of Decellularization Procedures For Porcine Arteries, Charles Clapp
Biomedical Engineering
Coronary artery disease has become the leading cause of death in the United States, with over 425,000 deaths in 2006. Stenting has evolved into the preferred preventative technique for myocardial infarction by opening up an occluded artery, due to its low invasiveness compared to the alternative of coronary artery bypass grafting. Bare metal stents have been improved by coating with anti-proliferative drugs to advance their effects, but even drug eluting stents still have a risk of restenosis, thrombus formation, and necessary revascularization. Continual advancement in stent design necessitates faster, effective pre-clinical evaluation techniques. Kristen Cardinal, Ph.D., developed the blood vessel …
Impact Of Collateral Enlargement On Smooth Muscle Phenotype, Alexander Jerome Bynum
Impact Of Collateral Enlargement On Smooth Muscle Phenotype, Alexander Jerome Bynum
Master's Theses
Peripheral Artery Disease is a very serious disease characterized by an arterial occlusion due to atherosclerotic plaques. In response to an arterial occlusion, arteriogenesis occurs, causing smooth muscle cells to transition from a contractile to synthetic state. Also following an arterial occlusion, functional impairment was seen in the collateral circuit. An immunofluorescence protocol was developed in order to assess the impact of collateral enlargement (arteriogenesis) on smooth muscle phenotype at various time points. Smooth muscle α-actin was used to mark all smooth muscle cells, Ki-67 was used to label proliferating smooth muscle cells, and a fluorescent nuclear stain was used …
Effect Of Size Reduction Parameters In Pharmaceutical Manufacturing Process, Brian Breneman
Effect Of Size Reduction Parameters In Pharmaceutical Manufacturing Process, Brian Breneman
Biomedical Engineering
Within pharmaceutical manufacturing, size reduction is one of the most extensively used and vital unit operations. Size reduction in tablet production is achieved primarily through milling procedures, which allows for attaining product uniformity, optimizing product solubility, and improving bioavailability. Additionally, powders with a narrow range of size distribution can obviate problems in downstream processing as pertains to blending, compression, and coating as well as improve drug performance1. The purpose this study was to characterize the effect of various size reduction parameters as a result of the pharmaceutical milling process on a lactose wet granulation formulation and chemically active …
Ischemia Impairs Vasodilation In Skeletal Muscle Resistance Artery, Kyle Remington Struthers
Ischemia Impairs Vasodilation In Skeletal Muscle Resistance Artery, Kyle Remington Struthers
Master's Theses
Functional vasodilation in arterioles is impaired with chronic ischemia. We sought to examine the impact of chronic ischemia and age on skeletal muscle resistance artery function. To examine the impact of chronic ischemia, the femoral artery was resected from young (2-3mo) and adult (6-7mo) mice and the profunda femoris artery diameter was measured at rest and following gracilis muscle contraction 14 days later using intravital microscopy. Functional vasodilation was significantly impaired in ischemic mice (14.4±4.6% vs. 137.8±14.3%, p<0.0001 n=8) and non-ischemic adult mice (103.0±9.4% vs. 137.8±14.3%, p=0.05 n=10). In order to analyze the cellular mechanisms of the impairment, a protocol was developed to apply pharmacological agents to the experimental preparation while maintaining tissue homeostasis. Endothelial and smooth muscle dependent vasodilation were impaired with ischemia, 39.6 ± 13.6% vs. 80.5 ± 11.4% and 43.0 ± 11.7% vs. 85.1 ± 10.5%, respectively. From this data, it can be supported that smooth muscle dysfunction is the reason for the observed impairment in arterial vasodilation.
An Inexpensive Method For Creating Paste To Be Used In Paper-Based Microfluidic Devices, Kirra Marie Sankey
An Inexpensive Method For Creating Paste To Be Used In Paper-Based Microfluidic Devices, Kirra Marie Sankey
Biomedical Engineering
Microfluidic devices are diagnostic tools that are small, portable, and inexpensive. This makes them ideally suited for resource-limited settings. To construct a 3D device, each layer of patterned paper is stacked using double-sided tape with holes corresponding to the pattern. It is necessary to have a paste to fill the holes in the tape and provide a medium for the fluid to wick through. The powder used to make the paste is very expensive and must be bought in bulk (an estimated $1121 - $1231), so it is not convenient for the Biomedical (BMED) department to use. This project was …
Mammary Epithelial Cell Growth On A Three-Dimensional Scaffold In An Operating Bioreactor, Melissa Marie Davalle
Mammary Epithelial Cell Growth On A Three-Dimensional Scaffold In An Operating Bioreactor, Melissa Marie Davalle
Master's Theses
Mammary epithelial cells are highly efficient secreting cells. With genetic engineering, the uses of these cells could be endless. Research is being conducted on these cells to determine their full potential to the biotech industry.
This paper investigates whether bovine epithelial mammary cells can survive in glutaraldehyde-treated gelatin tubes in an operating bioreactor. Many bioreactors were developed and tested to suit the needs of the cells. Procedures were created and carried out to ensure sterility of the bioreactors. Bovine mammary epithelial cells were implanted in the bioreactors and samples of their growth were taken over time.
A Study Of Osteocyte Apoptosis By Region And Quadrant In Murine Cortical Bone, Jessica Kristen Chan
A Study Of Osteocyte Apoptosis By Region And Quadrant In Murine Cortical Bone, Jessica Kristen Chan
Master's Theses
ABSTRACT
A Study of Osteocyte Apoptosis by Region and Quadrant in Murine Cortical Bone
Jessica Kristen Chan
Osteocytes undergo apoptosis to spatially and temporally initiate bone remodeling. This study investigates the distribution of apoptotic osteocytes within different quadrants and regions of cortical bone and compares the frequency of osteocyte apoptosis to regional factors associated with bone remodeling. Specifically, the quantity of apoptosis was compared to levels of the bone morphagenic protein antagonists noggin and gremlin. Samples of unloaded right tibial bone obtained from C57/Bl/6 mice underwent TUNEL staining for apoptotic osteocytes and were counterstained with methyl green to detect osteocyte …
Sar Map Of Gel Phantom In A 64mhz Mri Birdcage By Fiber-Optic Thermometry And Fdtd Simulation, Chirag Mukesh Patel
Sar Map Of Gel Phantom In A 64mhz Mri Birdcage By Fiber-Optic Thermometry And Fdtd Simulation, Chirag Mukesh Patel
Master's Theses
As implantable medical devices are being used more often to treat medical problems for which pharmaceuticals don’t suffice, it is important to understand their interactions with commonly used medical modalities. The interactions between medical implants and Magnetic Resonance Imaging machines have proven to be a risk for patients with implants.
Implanted medical devices with elongated metallic components can create harmful levels of local heating in a Magnetic Resonance Imaging (MRI) environment [1]. The heating of a biological medium under MRI is monitored via the Specific Absorption Rate (SAR). SAR, defined as power absorbed per unit mass (W/kg), can be calculated …
Assessment Of Morphology And Hemodynamics In Normal And Remodeled Microvasculature With Parameter Sensitivity Analysis, Shilpi Ghosh
Assessment Of Morphology And Hemodynamics In Normal And Remodeled Microvasculature With Parameter Sensitivity Analysis, Shilpi Ghosh
Master's Theses
The goal of this study was to compare the morphological and hemodynamic characteristics of normal and remodeled vascular networks in the mouse gracilis muscle. To this end, previously developed models to assess flows and vascular branching were used to assess the normal and remodeled microcirculatory networks. The analysis revealed that the average individual vessel flow rates for vessels of similar caliber and total volumetric flow rates in the networks do not change for vessels of the same caliber after remodeling. Connectivity changes and average diameters primarily change in the larger arterioles after remodeling. A few correlations could be made between …
An Investigative Study Into The Relationship Of Bone Morphogenetic Protein Antagonist Expression And Osteocyte Density By Region And Quadrant, Scott C. Mosher
An Investigative Study Into The Relationship Of Bone Morphogenetic Protein Antagonist Expression And Osteocyte Density By Region And Quadrant, Scott C. Mosher
Master's Theses
The role of cytokines and cell behavior and viability with respect to bone remodeling and bone behavior is an exciting area of orthopedic research. The purpose of this study was to investigate the relationships between BMP antagonist expression and osteocyte density, lacunar densities and osteocyte viability in cortical bone. Samples of unloaded tibial bone obtained from six C57Bl/6 mice were immunohistochemically stained for gremlin and noggin expression and also underwent methyl green staining to determine osteocyte presence. Bone sections were divided into four quadrants (cranial, caudal, medial and lateral) and three regions (proximal, mid shaft and distal), followed by analysis …
Finite Element Analysis And Modeling Of A .38 Lead Round Nose Ballistic Gelatin Test, Danielle Datoc
Finite Element Analysis And Modeling Of A .38 Lead Round Nose Ballistic Gelatin Test, Danielle Datoc
Master's Theses
Firearms are present in two-thirds of United States households. As of 2003, roughly 500,000 projectile wounds occur annually in the United States. This costs an estimated 2.3 billion dollars of medical spending. The best treatment of gunshot wounds relies heavily on experience, but even with experience the unpredictable nature of ballistics can make treatment difficult.
Wound ballistics studies the injury pattern of a particular bullet. Ballistic gelatin tests are used to analyze this pattern. A block of 10 or 20% ballistic gelatin is set and a bullet is fired through the block. Key characteristics of the wound profile seen in …
An Investigation Of Humeral Stress Fractures In Racing Thoroughbreds Using A 3d Finite Element Model In Conjunction With A Bone Remodeling Algorithm, Ryan James Moore
An Investigation Of Humeral Stress Fractures In Racing Thoroughbreds Using A 3d Finite Element Model In Conjunction With A Bone Remodeling Algorithm, Ryan James Moore
Master's Theses
The humerus of a racing horse Thoroughbred is highly susceptible to stress fractures at a characteristic location as a result of cyclic loading. The propensity of a Thoroughbred to exhibit humeral fracture has made equines useful models in the epidemiology of stress fractures. In this study, a racing Thoroughbred humerus was simulated during training using a 3D finite element model in conjunction with a bone remodeling algorithm. Nine muscle forces and two contact forces were applied to the 3-dimensional finite element model, which contains four separate load cases representing fore-stance, mid-stance, aft-stance, and standing. Four different training programs were incorporated …
A Computational Model Of Apoptotic Osteocyte Correlation To Cortical Bone Remodeling Parameters, Michael Stephen Alexander
A Computational Model Of Apoptotic Osteocyte Correlation To Cortical Bone Remodeling Parameters, Michael Stephen Alexander
Master's Theses
The onset of osteoporosis caused by aging, disease states, and post-menopausal conditions significantly impacts patient quality of life, required healthcare funding, personal autonomy losses from increased fracture risk and the subsequent corrective surgery. Research has indicated that osteocyte apoptosis may be a key parameter in bone remodeling, raising the possibility of remodeling rate modulation for the mitigation of bone mass resorption. By developing therapies that target osteocyte apoptosis, it may be possible to prevent undesired bone remodeling activity while maintaining a healthy balance between damage formation in the form of microcracks induced by the strain environment and the removal of …
The Electrical Properties Of Human Tissue For The Diagnosis And Treatment Of Melanoma Skin Cancer, Glenn Cameron Stante
The Electrical Properties Of Human Tissue For The Diagnosis And Treatment Of Melanoma Skin Cancer, Glenn Cameron Stante
Master's Theses
This thesis discusses the research, experimental methods, and data gathered for the investigation of a novel method for the diagnosis of melanoma skin cancer. First, a background about human skin tissue is presented. Then, a detailed description of melanoma along with current diagnosis techniques and treatment options are presented. In the experimental methods, the electrical properties of several types of tissue were analyzed, the purpose of which was to discover if a tissue type can be distinguished by its electrical properties alone. This would allow for the diagnosis of melanoma to be done by examining the electrical properties of the …
Time-Frequency Analysis Of Intracardiac Electrogram, Erik Brockman
Time-Frequency Analysis Of Intracardiac Electrogram, Erik Brockman
Master's Theses
The Cardiac Rhythm Management Division of St. Jude Medical specializes in the development of implantable cardioverter defibrillators that improve the quality of life for patients diagnosed with a variety of cardiac arrhythmias, especially for patients prone to sudden cardiac death. With the goal to improve detection of cardiac arrhythmias, this study explored the value in time-frequency analysis of intracardiac electrogram in four steps. The first two steps characterized, in the frequency domain, the waveforms that construct the cardiac cycle. The third step developed a new algorithm that putatively provides the least computationally expensive way to identifying cardiac waveforms in the …
The Impact Of Lipid Percentage On Fibrous Cap Stability In Atherosclerotic Lesions, Anita Lorraine Crompton
The Impact Of Lipid Percentage On Fibrous Cap Stability In Atherosclerotic Lesions, Anita Lorraine Crompton
Master's Theses
Coronary artery disease (CAD) is a common cause of sudden cardiac death. Much of the disease is not completely understood, which makes treatment and prevention difficult. Many researchers are using technology, such as advanced imaging techniques and finite element analysis, to better understand the disease. While there is much progress being made to look at the analysis of actual excised diseased arteries, there is still not a standardized model to predict the future of any one lesion. The purpose of this study is to explore the possibility of creating a standardized model to predict the mechanical stability of the fibrous …
Mechanical Simulation Of Articular Cartilage Based On Experimental Results, Kevin Matthew Stewart
Mechanical Simulation Of Articular Cartilage Based On Experimental Results, Kevin Matthew Stewart
Master's Theses
Recently, a constituent based cartilage growth finite element model (CGFEM) was developed in order to predict articular cartilage (AC) biomechanical properties before and after growth. Previous research has noted limitations in the CGFEM such as model convergence with growth periods greater than 12 days. The main aims of this work were to address these limitations through (1) implementation of an exact material Jacobian matrix definition using the Jaumann-Kirchhoff (J-K) method and (2) quantification of elastic material parameters based upon research findings of the Cal Poly Cartilage Biomechanics Group (CPGBG). The J-K method was successfully implemented into the CGFEM and exceeded …
Preparation For Nerve Membrane Potential Readings Of A Leech, Laboratory Setup And Dissection Process, Jason Patrick Caulfield
Preparation For Nerve Membrane Potential Readings Of A Leech, Laboratory Setup And Dissection Process, Jason Patrick Caulfield
Master's Theses
A well documented laboratory setup, leech preparation process, and bio-potential data recording process are needed. Repeatability and quality data recordings are essential and thus dictate the requirements of the laboratory setup and processes listed above. Advances in technology have both helped and hindered this development. While very precise equipment is required to record the low voltage bio-potentials, noisy electronic equipment and wires surrounding the work area provide high levels of interference. Proper laboratory setup and data recording processes, however, limit the unwanted interference. Quality data can only be recorded from a properly handled and prepared leech subject. Proper setup and …
Do Canines Experience The Effects Of Heart Rate Turbulence?, Melanie Ann Gurunathan
Do Canines Experience The Effects Of Heart Rate Turbulence?, Melanie Ann Gurunathan
Master's Theses
Background
The canine cardiac system has been the model against which many Class III cardiac devices are validated. Thus, it is expected that the canine heart has very similar electrical model to that found in humans. In 1999, the absence of Heart Rate Turbulence (HRT) after a single Pre-Ventricular Contraction (PVC) was linked to high-risk patient after acute myocardial infarction. Studies of HRT were performed on high-risk patients with Holter-Monitors as were most subsequent HRT studies. If HRT could potentially be used as a risk factor of heart disease, it is interesting to study whether HRT is present following a …
Implementation Of Physiologic Flow Conditions In A Blood Vessel Mimic Bioreactor System For The Evaluation Of Intravascular Devices, Marc Cody Dawson
Implementation Of Physiologic Flow Conditions In A Blood Vessel Mimic Bioreactor System For The Evaluation Of Intravascular Devices, Marc Cody Dawson
Master's Theses
The prevalence and devastating nature of cardiovascular diseases has led to many advancements in the therapies used to treat the millions of patients that suffer as a result of these conditions. As coronary artery disease (CAD) is the most common of these cardiovascular conditions, it is a major focus of research among the medical industry. Although lifestyle changes and drug therapies can treat early CAD, more advanced cases often require more definitive interventions. In conjunction with angioplasty, stenting of an occluded vessel has shown significant success in preventing restenosis. However, as with nearly every therapeutic process in the medical field, …