Open Access. Powered by Scholars. Published by Universities.®

2021

Discipline
Institution
Keyword
Publication
Publication Type

Articles 61 - 72 of 72

Full-Text Articles in Biomedical Devices and Instrumentation

Sensitray: An Integrated Measuring Device For Monitoring Children’S Mealtime Dietary Intake, Hunter S. Guru, Anthony D. Weng, Santosh Pitla, Dipti Dev Jan 2021

Sensitray: An Integrated Measuring Device For Monitoring Children’S Mealtime Dietary Intake, Hunter S. Guru, Anthony D. Weng, Santosh Pitla, Dipti Dev

Department of Child, Youth, and Family Studies: Faculty Publications

Childhood nutrition establishes consumption norms that affect an individual’s health over the course of their lives. However, early nutrition interventions to establish such norms are uncommon owing to the various inefficiencies associated with current methods of measuring childhood nutrition. Here, we present an IoT measuring device, called the SensiTray, which accurately tracks mealtime intake in a child-friendly and cost-effective fashion. Principal technologies underlying the SensiTray (including mass-sensing technologies, microcontrollers) are identified and analyzed, along with other design choices. Operation of the SensiTray is explained with special attention given to SensiTray software peripherals and algorithms. Preliminary testing consisted of static and …


Electrospinning Of Formic Acid/Acetic Acid And Nylon-6 Solutions For Wearable Hydration Sensors, Nichole Cooper, Jonathan Doak Jan 2021

Electrospinning Of Formic Acid/Acetic Acid And Nylon-6 Solutions For Wearable Hydration Sensors, Nichole Cooper, Jonathan Doak

Williams Honors College, Honors Research Projects

Students have been working on the development of wearable hydration sensors at the startup company RooSense. The goal of the company is to develop a lightweight wearable sensor that enables the user to know their hydration level, thus elevating their performance goals. To measure the hydration of the wearer, the sodium and other salt ions are collected from the user’s sweat as they exercise. This sweat is analyzed as it is collected to give the user an exact level of hydration, so they know how much fluids they need. The production of this ion sensor requires numerous steps and iteration …


Ecg Monitoring In Athletes, Jalal Jwayyed, Kelly Purgason, Joseph Linder, Annamarie Alfery, Silvia Furman Jan 2021

Ecg Monitoring In Athletes, Jalal Jwayyed, Kelly Purgason, Joseph Linder, Annamarie Alfery, Silvia Furman

Williams Honors College, Honors Research Projects

Athletes and medical personnel need reliable methods to monitor vital signs and detect potentially life-threatening issues before they occur. Electrocardiograph (ECG) monitors are currently the best method of detecting heart-related health issues. Current ECG monitors worn by athletes are difficult to use and lack the ability to track ECGs in real time. Through research and interviews with various clinicians, further problems have been identified that include poor electrode adhesion, and a lack of compatibility with the equipment worn by athletes. Our team proposes to develop solutions that will improve performance and comfort associated with ECG monitors for athletic applications. This …


Improving The Monitoring Of Post-Operative Patient Mobility, Owen T. Lacey, Alexandria Magyar-Averin, Elena Ewing, Samuel Elliott, Cameron Lazor Jan 2021

Improving The Monitoring Of Post-Operative Patient Mobility, Owen T. Lacey, Alexandria Magyar-Averin, Elena Ewing, Samuel Elliott, Cameron Lazor

Williams Honors College, Honors Research Projects

Patient post-operative care is essential in attaining positive patient outcomes. To ensure proper blood circulation for recovery and healing is achieved, a patient's mobility is monitored. However, medical professionals aren't always available to continuously monitor patient progress. The clinical need for a medical device to monitor and quantify patient movement automatically is derived and addressed here. By designing a novel device and associated code, an engineering solution to this clinical need can be developed to monitor and improve patient post-operative outcomes in the absence of a medical professional. After completing research on the clinical need and gathering information from stakeholders …


Tubing/Lines Entanglement Reduction In Healthcare Settings, Abigail Kraft, Amy Beskitt, Grace Elerick, Zachery Steck Jan 2021

Tubing/Lines Entanglement Reduction In Healthcare Settings, Abigail Kraft, Amy Beskitt, Grace Elerick, Zachery Steck

Williams Honors College, Honors Research Projects

Intravenous (IV) lines used in various healthcare settings pose a risk to patients and their caretakers. A few common risks include IV lines becoming torn out and coming into contact with open wounds. We propose to solve this problem by designing a device that prevents IV and wire entanglement without obstructing patient care. Our objectives in identifying a solution include increasing patient comfort, mobility, and ease of transfer. By solving this issue, other potential benefits include reducing time spent on non-essential tasks and reducing number of personnel needed to transport patients. We intend to validate our product with healthcare employees …


Exploring Rapid Solidification And Equal Channel Angular Pressing In The Fabrication Of Mg-Based Alloys For Medical Applications, Emily Tom Jan 2021

Exploring Rapid Solidification And Equal Channel Angular Pressing In The Fabrication Of Mg-Based Alloys For Medical Applications, Emily Tom

Dissertations, Master's Theses and Master's Reports

The development of magnesium bioresorbable implants has become increasingly popular due to the increased need for temporary implants and magnesium’s excellent biocompatibility and suitable elastic modulus. Even though magnesium is an excellent candidate, when alloyed with other metals magnesium’s corrosion rate becomes too rapid for bioresorbable medical applications. The investigation into novel processing techniques to control the formation of precipitates to improve mechanical strength and ductility as well as corrosion rates has become of interest. This work investigates the combination of two nonequilibrium processing techniques, rapid solidification (RS) and equal channel angular pressing (ECAP), and the effects it has on …


Assessing Heart Rate Using Consumer Technology Association Standards, Joel D. Reece, Jennifer A. Bunn, Minsoo Choi, James W. Navalta Jan 2021

Assessing Heart Rate Using Consumer Technology Association Standards, Joel D. Reece, Jennifer A. Bunn, Minsoo Choi, James W. Navalta

Kinesiology and Nutrition Sciences Faculty Research

It is difficult for developers, researchers, and consumers to compare results among emerging wearable technology without using a uniform set of standards. This study evaluated the accuracy of commercially available wearable technology heart rate (HR) monitors using the Consumer Technology Association (CTA) standards. Participants (N = 23) simultaneously wore a Polar chest strap (criterion measure), Jabra Elite earbuds, Scosche Rhythm 24 armband, Apple Watch 4, and Garmin Forerunner 735 XT during sitting, activities of daily living, walking, jogging, running, and cycling, totaling 57 min of monitored activity. The Apple Watch mean bias was within ±1 bpm, and mean absolute percent …


Safety Analysis Of Battery-Powered Adaptive Ride-On Toys For Children With Disabilities, Abbey Fraser Jan 2021

Safety Analysis Of Battery-Powered Adaptive Ride-On Toys For Children With Disabilities, Abbey Fraser

UNF Graduate Theses and Dissertations

Modified battery-powered ride-on toy cars, or adaptive ride-on toys, represent novel rehabilitation tools and developmental aids for children with disabilities. Studies have shown that children are benefiting socially and developmentally from their use. However, the use of these toys by children with disabilities potentially poses a risk of injury and it is vitally important to ensure the safe use of these toys, particularly for the benefit of those with developmental challenges.

Within this context, the purpose of the first study was to determine whether modifications to ride-on toys are sufficient to prevent common modes of injury such as falls, passenger …


Nebulizer-Based Systems To Improve Pharmaceutical Aerosol Delivery To The Lungs, Benjamin M. Spence Jan 2021

Nebulizer-Based Systems To Improve Pharmaceutical Aerosol Delivery To The Lungs, Benjamin M. Spence

Theses and Dissertations

Combining vibrating mesh nebulizers with additional new technologies leads to substantial improvements in pharmaceutical aerosol delivery to the lungs across therapeutic administration methods. In this dissertation, streamlined components, aerosol administration synchronization, and/or Excipient Enhanced Growth (EEG) technologies were utilized to develop and test several novel devices and aerosol delivery systems. The first focus of this work was to improve the poor delivery efficiency, e.g., 3.6% of nominal dose (Dugernier et al. 2017), of aerosolized medication administration to adult human subjects concurrent with high flow nasal cannula (HFNC) therapy, a form of continuous-flow non-invasive ventilation (NIV). The developed Low-Volume Mixer-Heater (LVMH) …


Development Of Light Actuated Chemical Delivery Platform On A 2-D Array Of Micropore Structure, Hojjat Rostami Azmand, Hojjat Rostami Azmand Jan 2021

Development Of Light Actuated Chemical Delivery Platform On A 2-D Array Of Micropore Structure, Hojjat Rostami Azmand, Hojjat Rostami Azmand

Dissertations and Theses

Localized chemical delivery plays an essential role in the fundamental information transfers within biological systems. Thus, the ability to mimic the natural chemical signal modulation would provide significant contributions to understand the functional signaling pathway of biological cells and develop new prosthetic devices for neurological disorders. In this paper, we demonstrate a light-controlled hydrogel platform that can be used for localized chemical delivery in a high spatial resolution. By utilizing the photothermal behavior of graphene-hydrogel composites confined within micron-sized fluidic channels, patterned light illumination creates the parallel and independent actuation of chemical release in a group of fluidic ports. The …


Development Of A Biaxial Testing System For Research Of Soft Tissue Biomechanics Using Laboratory Models, Tariq Shameen Jan 2021

Development Of A Biaxial Testing System For Research Of Soft Tissue Biomechanics Using Laboratory Models, Tariq Shameen

Dissertations and Theses

The rupture of the cap tissue layer of a fibroatheroma in human coronary vessels is considered the key event leading to the formation of a thrombus and myocardial infarction, resulting in more than half a million deaths in the US every year. In this study, we are interested in investigating the biomechanics of different elastomer materials that can be used as laboratory models to replicate coronary arteries’ ultimate tensile stress (0.2 - 2.08 MPa). To this end, we developed a biomechanical testing system that allows us to characterize the material properties of small samples with high accuracy and precision. We …


Activity Recognition Based On Thermopile Imaging Array Sensors, Qingshan Liang Jan 2021

Activity Recognition Based On Thermopile Imaging Array Sensors, Qingshan Liang

Dissertations and Theses @ UNI

With aging population, the importance of caring for elderly people is getting more and more attention. In this paper, a low resolution thermopile array sensor is used to develop an activity recognition system for elderly people. The sensor is composed of a 32x32 thermopile array with the corresponding 33° × 33° field of view. The outputs of the sensor are sequential images in which each pixel contains a temperature value. According to the thermopile images, the activity recognition system first determines whether the target is within the tracking area; if the target is within the tracking area, the location of …