Open Access. Powered by Scholars. Published by Universities.®

2019

Discipline
Institution
Keyword
Publication
Publication Type
File Type

Articles 61 - 76 of 76

Full-Text Articles in Biomedical Devices and Instrumentation

Well-Ordered Mesoporous Silica And Bioactive Glasses: Promise For Improved Hemostasis, Sara Pourshahrestani, Nahrizul Adib Kadri, Ehsan Zeimaran, Mark R. Towler Jan 2019

Well-Ordered Mesoporous Silica And Bioactive Glasses: Promise For Improved Hemostasis, Sara Pourshahrestani, Nahrizul Adib Kadri, Ehsan Zeimaran, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Immediate control of uncontrolled bleeding and infection are essential for saving lives in both combat and civilian arenas. Inorganic well-ordered mesoporous silica and bioactive glasses have recently shown great promise for accelerating hemostasis and infection control. However, to date, there has been no comprehensive report assessing their specific mechanism of action in accelerating the hemostasis process and exerting an antibacterial effect. After providing a brief overview of the hemostasis process, this review presents a critical overview of the recently developed inorganic mesoporous silica and bioactive glass-based materials proposed for hemostatic clinical applications and specifically investigates their unique characteristics that render …


The Impact Of Extreme Virtual Elevation Above Grade On Construction Workers' Physiological Responses, Physical Responses, And Task Performance, Mahmoud Habibnezhad Jan 2019

The Impact Of Extreme Virtual Elevation Above Grade On Construction Workers' Physiological Responses, Physical Responses, And Task Performance, Mahmoud Habibnezhad

Department of Construction Engineering and Management: Dissertations, Theses, and Student Research

On average, in every two work hours, one person dies from work-related injuries at construction sites. Most incidents are due to falling from elevated surfaces. Slips, trips, and loss of balance are the main causes. Studies suggest that instigating visual mismatch and physiological changes are among the most important reasons behind falling from narrow elevated surfaces. By using advanced virtual reality models, this dissertation aims to highlight some of the possible effects of a destabilizing environment (i.e., elevation above grade) on workers’ physiological responses and task performance. More specifically, this dissertation strives to find potential effects of elevation above grade …


Testing And Validation Framework For Closed-Loop Physiology Management Systems For Critical And Perioperative Care, Farooq M. Gessa Jan 2019

Testing And Validation Framework For Closed-Loop Physiology Management Systems For Critical And Perioperative Care, Farooq M. Gessa

Master’s Theses

The research aims at developing a framework for testing systems such as closed-loop physiology management systems to ensure that they are safe and effective for use with patients. Building medical devices that are both robust and safe is a challenge. There has been a tremendous increase in modernization and innovation of various medical systems but many of these systems either fail trials or are recalled due to safety issues.

Medical operation rooms require care teams responsible for monitoring the patients and other technical surgical devices. The care process requires a balancing administration that takes care of the drugs and fluids …


The Wrist Brace Project, Nathan Nicholas Jan 2019

The Wrist Brace Project, Nathan Nicholas

Williams Honors College, Honors Research Projects

This paper outlines the engineering design process of creating a specialized wrist brace for a local child. This project was completed by a team of senior Biomedical Engineering students.


Fabrication And Characterization Of Nanofiber Nylon-6-Mwcnt As An Electrochemical Sensor For Sodium Ions Concentration Detection In Sweat, Kelsey Mills Jan 2019

Fabrication And Characterization Of Nanofiber Nylon-6-Mwcnt As An Electrochemical Sensor For Sodium Ions Concentration Detection In Sweat, Kelsey Mills

Williams Honors College, Honors Research Projects

Fabrication and characterization nylon-6-MWCNT nanofiber as an electrochemical sensor to detect sodium ion concentrations specifically in sweat. Using contact angle to determine surface morphology and chronoamperometry testing to identify ideal sensor conditions, tests optimized parameters like weight percent of nylon or other polymers, carbon nanotube (CNT) isomer, and solution concentration to determine reproducibility of functional sensors. Utilizing the electric qualities of carbon nanotubes partnered with the sodium ion selectivity of calixarene treatment and polymers unique properties like flexibility and scalability create open an arena for optimizing sodium ion sensors for further development for functional prototypes. Morphology tests showed that the …


The Second Wind, Jacob Heiss, Logan Neidert Jan 2019

The Second Wind, Jacob Heiss, Logan Neidert

Williams Honors College, Honors Research Projects

The Second Wind device is a set of sensors and a data processing unit capable of recording data necessary to conduct a simplified version of a complex cardiopulmonary stress test (CPET). This data includes VO2, VCO2, ventilation, and pulse oximetry data. VO2 and VCO2 are the percent, by volume, of oxygen and carbon dioxide in the patient's breath, spirometry is the measure of air flow, and the pulse oximetry data includes heart rate (HR) and percent oxygen in the blood (SpO2). In addition, the device was designed to be portable, so this test could be run from patients’ homes or …


Quickcough: An Instrumentational Proximal Airway Clearance Technique (Act) For Select Patients With Neuromuscular Disease (Nmd), Sean X. Sullivan, Russell K. Catania, Madison K. Plaster, Sydney E. Kandray, Mariah Costa Jan 2019

Quickcough: An Instrumentational Proximal Airway Clearance Technique (Act) For Select Patients With Neuromuscular Disease (Nmd), Sean X. Sullivan, Russell K. Catania, Madison K. Plaster, Sydney E. Kandray, Mariah Costa

Williams Honors College, Honors Research Projects

Patients with neuromuscular disease (NMD) requiring tracheostomy and mechanical ventilation secondary to respiratory failure encounter increased difficulty in removing pulmonary secretions from the airways. To combat issues associated with current treatment modalities for insufficient cough efficacy (cost, poor mobility, discomfort, lack of evidence), we have developed an instrumentational proximal airway clearance technique (ACT) which augments a manual proximal ACT developed by a client with NMD. QuickCough is a 3D-printed PLA attachment to the tracheostomy apparatus which has demonstrated its ability to facilitate pressure changes necessary to increase patient’s peak cough flow (PCF) by providing a stronger exsufflation for the patient. …


Easy Adjustable Protective Helmet, Ryan Balash Jan 2019

Easy Adjustable Protective Helmet, Ryan Balash

Williams Honors College, Honors Research Projects

Akron Children’s Hospital and The University of Akron’s Biomedical Engineering Design Team Engineering Forward have paired together to improve medical adapted helmets for post-operative and disabled patients. An issue is the helmets are only produced in a couple of sizes. Also, it is a tedious process to constantly adjust the pressure on the patient’s cranium within a trial-and-error process. Engineering Forward plans to improve the effectiveness of this helmet by creating an adjustable helmet that can read the pressure on a patient’s head. The caregiver can then make the necessary adjustments to the helmet to accommodate the patient. Documents of …


Exploring The Role And Impact Of Microscale Phenomena On Electrode, Microdevice, And Cellular Function, Sanaz Habibi Jan 2019

Exploring The Role And Impact Of Microscale Phenomena On Electrode, Microdevice, And Cellular Function, Sanaz Habibi

Dissertations, Master's Theses and Master's Reports

Microfluidic technologies enable the development of portable devices to perform multiple high-resolution unit operations with small sample and reagent volumes, low fabrication cost, facile operation, and quick response times. Microfluidic platforms are expected to effectively interpret both wanted and unwanted phenomena; however, a comprehensive evaluation of the unwanted phenomena has not been appropriately investigated in the literature. This work explored an attenuative evaluation of unwanted phenomena, also called here as secondary phenomena, in a unique approach.

Upon electric field utilization within microfluidic devices, electrode miniaturization improves device sensitivity. However, electrodes in contact with medium solution can yield byproducts that can …


Estimation Of Multi-Directional Ankle Impedance As A Function Of Lower Extremity Muscle Activation, Lauren Knop Jan 2019

Estimation Of Multi-Directional Ankle Impedance As A Function Of Lower Extremity Muscle Activation, Lauren Knop

Dissertations, Master's Theses and Master's Reports

The purpose of this research is to investigate the relationship between the mechanical impedance of the human ankle and the corresponding lower extremity muscle activity. Three experimental studies were performed to measure the ankle impedance about multiple degrees of freedom (DOF), while the ankle was subjected to different loading conditions and different levels of muscle activity. The first study determined the non-loaded ankle impedance in the sagittal, frontal, and transverse anatomical planes while the ankle was suspended above the ground. The subjects actively co-contracted their agonist and antagonistic muscles to various levels, measured using electromyography (EMG). An Artificial Neural Network …


A Smart Implantable Bone Fixation Plate Providing Actuation And Load Monitoring For Orthopedic Fracture Healing, Brad Nelson Jan 2019

A Smart Implantable Bone Fixation Plate Providing Actuation And Load Monitoring For Orthopedic Fracture Healing, Brad Nelson

Dissertations, Master's Theses and Master's Reports

Fracture non-union occurs in roughly 5-10% of all fracture cases, and current interventions are both time-consuming and costly. There is therefore significant incentive to develop new tools to improve fracture healing outcomes. Several studies have shown that low-magnitude, high-frequency (LMHF) mechanical loading can promote faster healing and reduce the risk of refracture in critical-size long bone fractures. This is typically done using whole-body vibration, which may result in undesirable systemic effects on the rest of the body. This work discusses an implantable piezoelectric fixation plate that can both apply LMHF loading directly to the fracture site using flexible scheduling and …


Development Of An Impedance-Controlled Hot Snare Polypectomy Device To Minimize Tissue Damage, Curtislee Thornton Jan 2019

Development Of An Impedance-Controlled Hot Snare Polypectomy Device To Minimize Tissue Damage, Curtislee Thornton

College of Graduate Studies: Theses & Dissertations

This study explores the ability to measure the changing impedance, ex vivo, of a porcine colon sample while undergoing a high-frequency alternating current from an Olympus PSD-30 electrosurgical unit and stop the applied current before excessive tissue damage ensues. The causes of the thermal damage are first examined, followed by the construction and testing of the impedance-controlled feedback device. Perforation was observed to occur when the impedance of the tissue sample increased by 25% or more. Using this information, the device was tested for five power settings ranging from 10W-50W. In each trial, the feedback device stopped the applied current …


Development Of An Eye Movement Based Predictive Model For Discrimination Of Parkinson's Disease From Other Parkinsonisms And Controls, Mary Anisa Kannan Jan 2019

Development Of An Eye Movement Based Predictive Model For Discrimination Of Parkinson's Disease From Other Parkinsonisms And Controls, Mary Anisa Kannan

Theses and Dissertations

Purpose: Due to the neurological aspects of Parkinson’s Disease (PD) and the sensitivity of eye movements to neurological issues, eye tracking has the potential to be an objective biomarker with higher accuracy in diagnosis than current clinical standards. Currently when PD is diagnosed clinically, there is an accuracy of 74% when diagnosed by a general practitioner and 82% when diagnosed by a movement disorder specialist. This study was designed to: 1. Assess eye movements as a potential biomarker for Parkinson’s Disease. 2. Determine if eye movements can distinguish between Parkinson’s Disease and commonly confounded movement disorders with parkinsonian symptoms. 3. …


Assessment Of Access Methods For Mobile Maps For Individuals Who Are Blind Or Visually Impaired, David Parker Jan 2019

Assessment Of Access Methods For Mobile Maps For Individuals Who Are Blind Or Visually Impaired, David Parker

Theses and Dissertations

When people go to a mall, museums, or other such locations they tend to rely on maps to find their way around. However, for people who are blind or visually impaired (BVI) maps are not easily accessible and they depend on other means, such as a guide, to get around. Research has only just begun to investigate providing maps for people who are BVI on touch screen devices. Many different types of feedback have been used: audio (sound), tactile (touch), audio-tactile, and multitouch. Some research has been conducted on the benefit of using multiple fingers (multitouch) and has found conflicting …


Assessing Endothelial Dysfunction Estimating The Differences Between 3 Minute And 5 Minute Reactive Hyperemia, Tamiko K. Saldin Jan 2019

Assessing Endothelial Dysfunction Estimating The Differences Between 3 Minute And 5 Minute Reactive Hyperemia, Tamiko K. Saldin

Master's Theses

The purpose of this study was to define a lower standard cuff occlusion time to induce reactive hyperemia in assessing endothelial dysfunction. In this study, strong evidence was found by a novel technique that used oscillometric methods, which supported that 3 minute reactive hyperemia was sufficient to elicit a significant difference in arterial compliance from baseline. Twenty healthy Cal Poly students were assessed, (n=12 female, n=8 male) aged 22 years old with a standard deviation of 2.04 years. Arterial compliance was estimated by measuring the peak-to-peak oscillations for baseline, 3 minute reactive hyperemia, and 5 minute reactive hyperemia tests, with …


Multiscale Mathematical Modelling Of Nonlinear Nanowire Resonators For Biological Applications, Rosa Fallahpourghadikolaei Jan 2019

Multiscale Mathematical Modelling Of Nonlinear Nanowire Resonators For Biological Applications, Rosa Fallahpourghadikolaei

Theses and Dissertations (Comprehensive)

Nanoscale systems fabricated with low-dimensional nanostructures such as carbon nanotubes, nanowires, quantum dots, and more recently graphene sheets, have fascinated researchers from different fields due to their extraordinary and unique physical properties. For example, the remarkable mechanical properties of nanoresonators empower them to have a very high resonant frequency up to the order of giga to terahertz. The ultra-high frequency of these systems attracted the attention of researchers in the area of bio-sensing with the idea to implement them for detection of tiny bio-objects. In this thesis, we originally propose and analyze a mathematical model for nonlinear vibrations of nanowire …