Open Access. Powered by Scholars. Published by Universities.®
Biomedical Devices and Instrumentation Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Medicine and Health Sciences (14)
- Electrical and Computer Engineering (11)
- Other Biomedical Engineering and Bioengineering (11)
- Chemical Engineering (10)
- Mechanical Engineering (10)
-
- Biochemical and Biomolecular Engineering (9)
- Biomedical (9)
- Biomechanical Engineering (8)
- Biomechanics and Biotransport (8)
- Physical Sciences and Mathematics (8)
- Bioelectrical and Neuroengineering (7)
- Bioimaging and Biomedical Optics (5)
- Computer Sciences (5)
- Rehabilitation and Therapy (5)
- Computer Engineering (4)
- Medical Sciences (4)
- Molecular, Cellular, and Tissue Engineering (4)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (3)
- Biological Engineering (3)
- Biomaterials (3)
- Electrical and Electronics (3)
- Life Sciences (3)
- Medical Specialties (3)
- Orthotics and Prosthetics (3)
- Systems and Integrative Engineering (3)
- Vision Science (3)
- Acoustics, Dynamics, and Controls (2)
- Institution
-
- California Polytechnic State University, San Luis Obispo (18)
- Missouri University of Science and Technology (7)
- University of Arkansas, Fayetteville (7)
- The University of Akron (5)
- Michigan Technological University (4)
-
- Dartmouth College (3)
- University of Nebraska at Omaha (3)
- City University of New York (CUNY) (2)
- Georgia Southern University (2)
- Louisiana State University (2)
- Old Dominion University (2)
- University of Connecticut (2)
- University of Nevada, Las Vegas (2)
- Virginia Commonwealth University (2)
- Boise State University (1)
- Bridgewater College (1)
- Brigham Young University (1)
- Bucknell University (1)
- Eastern Washington University (1)
- Grand Valley State University (1)
- Southern Methodist University (1)
- University of Kentucky (1)
- University of Louisville (1)
- University of Nebraska - Lincoln (1)
- Valparaiso University (1)
- Wayne State University (1)
- West Virginia University (1)
- Western University (1)
- Wilfrid Laurier University (1)
- Keyword
-
- Arduino (3)
- Biomedical (3)
- Biomedical engineering (2)
- Device (2)
- Electromyography (2)
-
- Engineering (2)
- MATLAB (2)
- Medical device (2)
- Microfluidics (2)
- Piezoelectric (2)
- Prosthetics (2)
- 3D printing (1)
- AFO (1)
- AMS 800 (1)
- Acupuncture (1)
- Acute myeloid leukemia (1)
- Airway clearance technique (1)
- Alanine (1)
- Amputees (1)
- Ankle (1)
- Ankle support (1)
- Anti-saccade (1)
- Aspartate (1)
- Assist (1)
- Assistive technology (1)
- Audio (1)
- Automated (1)
- BMP (1)
- Binary shark smell optimization (1)
- Bio-impedance spectroscopy torso SFB7 fluid level (1)
- Publication
-
- Biomedical Engineering (11)
- Chemical and Biochemical Engineering Faculty Research & Creative Works (7)
- Master's Theses (6)
- Williams Honors College, Honors Research Projects (5)
- Dissertations, Master's Theses and Master's Reports (4)
-
- Graduate Theses and Dissertations (4)
- UNO Student Research and Creative Activity Fair (3)
- Bioelectrics Publications (2)
- Biomedical Engineering Undergraduate Honors Theses (2)
- ENGS 89/90 Reports (2)
- LSU Doctoral Dissertations (2)
- Publications and Research (2)
- Theses and Dissertations (2)
- UNLV Theses, Dissertations, Professional Papers, and Capstones (2)
- Boise State University Theses and Dissertations (1)
- Chemical Engineering Undergraduate Honors Theses (1)
- College of Graduate Studies: Theses & Dissertations (1)
- Department of Construction Engineering and Management: Dissertations, Theses, and Student Research (1)
- ENGS 88 Honors Thesis (AB Students) (1)
- EWU Masters Thesis Collection (1)
- Electrical Engineering (1)
- Electronic Theses and Dissertations (1)
- Graduate Theses, Dissertations, and Problem Reports (ETD) (1)
- Honors College Theses (1)
- Honors Projects (1)
- Honors Scholar Theses (1)
- Journal of Mind and Medical Sciences (1)
- Marriott Student Review (1)
- Masters Theses (1)
- Master’s Theses (1)
- Publication Type
Articles 61 - 76 of 76
Full-Text Articles in Biomedical Devices and Instrumentation
Well-Ordered Mesoporous Silica And Bioactive Glasses: Promise For Improved Hemostasis, Sara Pourshahrestani, Nahrizul Adib Kadri, Ehsan Zeimaran, Mark R. Towler
Well-Ordered Mesoporous Silica And Bioactive Glasses: Promise For Improved Hemostasis, Sara Pourshahrestani, Nahrizul Adib Kadri, Ehsan Zeimaran, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Immediate control of uncontrolled bleeding and infection are essential for saving lives in both combat and civilian arenas. Inorganic well-ordered mesoporous silica and bioactive glasses have recently shown great promise for accelerating hemostasis and infection control. However, to date, there has been no comprehensive report assessing their specific mechanism of action in accelerating the hemostasis process and exerting an antibacterial effect. After providing a brief overview of the hemostasis process, this review presents a critical overview of the recently developed inorganic mesoporous silica and bioactive glass-based materials proposed for hemostatic clinical applications and specifically investigates their unique characteristics that render …
The Impact Of Extreme Virtual Elevation Above Grade On Construction Workers' Physiological Responses, Physical Responses, And Task Performance, Mahmoud Habibnezhad
The Impact Of Extreme Virtual Elevation Above Grade On Construction Workers' Physiological Responses, Physical Responses, And Task Performance, Mahmoud Habibnezhad
Department of Construction Engineering and Management: Dissertations, Theses, and Student Research
On average, in every two work hours, one person dies from work-related injuries at construction sites. Most incidents are due to falling from elevated surfaces. Slips, trips, and loss of balance are the main causes. Studies suggest that instigating visual mismatch and physiological changes are among the most important reasons behind falling from narrow elevated surfaces. By using advanced virtual reality models, this dissertation aims to highlight some of the possible effects of a destabilizing environment (i.e., elevation above grade) on workers’ physiological responses and task performance. More specifically, this dissertation strives to find potential effects of elevation above grade …
Testing And Validation Framework For Closed-Loop Physiology Management Systems For Critical And Perioperative Care, Farooq M. Gessa
Testing And Validation Framework For Closed-Loop Physiology Management Systems For Critical And Perioperative Care, Farooq M. Gessa
Master’s Theses
The research aims at developing a framework for testing systems such as closed-loop physiology management systems to ensure that they are safe and effective for use with patients. Building medical devices that are both robust and safe is a challenge. There has been a tremendous increase in modernization and innovation of various medical systems but many of these systems either fail trials or are recalled due to safety issues.
Medical operation rooms require care teams responsible for monitoring the patients and other technical surgical devices. The care process requires a balancing administration that takes care of the drugs and fluids …
The Wrist Brace Project, Nathan Nicholas
The Wrist Brace Project, Nathan Nicholas
Williams Honors College, Honors Research Projects
This paper outlines the engineering design process of creating a specialized wrist brace for a local child. This project was completed by a team of senior Biomedical Engineering students.
Fabrication And Characterization Of Nanofiber Nylon-6-Mwcnt As An Electrochemical Sensor For Sodium Ions Concentration Detection In Sweat, Kelsey Mills
Williams Honors College, Honors Research Projects
Fabrication and characterization nylon-6-MWCNT nanofiber as an electrochemical sensor to detect sodium ion concentrations specifically in sweat. Using contact angle to determine surface morphology and chronoamperometry testing to identify ideal sensor conditions, tests optimized parameters like weight percent of nylon or other polymers, carbon nanotube (CNT) isomer, and solution concentration to determine reproducibility of functional sensors. Utilizing the electric qualities of carbon nanotubes partnered with the sodium ion selectivity of calixarene treatment and polymers unique properties like flexibility and scalability create open an arena for optimizing sodium ion sensors for further development for functional prototypes. Morphology tests showed that the …
The Second Wind, Jacob Heiss, Logan Neidert
The Second Wind, Jacob Heiss, Logan Neidert
Williams Honors College, Honors Research Projects
The Second Wind device is a set of sensors and a data processing unit capable of recording data necessary to conduct a simplified version of a complex cardiopulmonary stress test (CPET). This data includes VO2, VCO2, ventilation, and pulse oximetry data. VO2 and VCO2 are the percent, by volume, of oxygen and carbon dioxide in the patient's breath, spirometry is the measure of air flow, and the pulse oximetry data includes heart rate (HR) and percent oxygen in the blood (SpO2). In addition, the device was designed to be portable, so this test could be run from patients’ homes or …
Quickcough: An Instrumentational Proximal Airway Clearance Technique (Act) For Select Patients With Neuromuscular Disease (Nmd), Sean X. Sullivan, Russell K. Catania, Madison K. Plaster, Sydney E. Kandray, Mariah Costa
Quickcough: An Instrumentational Proximal Airway Clearance Technique (Act) For Select Patients With Neuromuscular Disease (Nmd), Sean X. Sullivan, Russell K. Catania, Madison K. Plaster, Sydney E. Kandray, Mariah Costa
Williams Honors College, Honors Research Projects
Patients with neuromuscular disease (NMD) requiring tracheostomy and mechanical ventilation secondary to respiratory failure encounter increased difficulty in removing pulmonary secretions from the airways. To combat issues associated with current treatment modalities for insufficient cough efficacy (cost, poor mobility, discomfort, lack of evidence), we have developed an instrumentational proximal airway clearance technique (ACT) which augments a manual proximal ACT developed by a client with NMD. QuickCough is a 3D-printed PLA attachment to the tracheostomy apparatus which has demonstrated its ability to facilitate pressure changes necessary to increase patient’s peak cough flow (PCF) by providing a stronger exsufflation for the patient. …
Easy Adjustable Protective Helmet, Ryan Balash
Easy Adjustable Protective Helmet, Ryan Balash
Williams Honors College, Honors Research Projects
Akron Children’s Hospital and The University of Akron’s Biomedical Engineering Design Team Engineering Forward have paired together to improve medical adapted helmets for post-operative and disabled patients. An issue is the helmets are only produced in a couple of sizes. Also, it is a tedious process to constantly adjust the pressure on the patient’s cranium within a trial-and-error process. Engineering Forward plans to improve the effectiveness of this helmet by creating an adjustable helmet that can read the pressure on a patient’s head. The caregiver can then make the necessary adjustments to the helmet to accommodate the patient. Documents of …
Exploring The Role And Impact Of Microscale Phenomena On Electrode, Microdevice, And Cellular Function, Sanaz Habibi
Exploring The Role And Impact Of Microscale Phenomena On Electrode, Microdevice, And Cellular Function, Sanaz Habibi
Dissertations, Master's Theses and Master's Reports
Microfluidic technologies enable the development of portable devices to perform multiple high-resolution unit operations with small sample and reagent volumes, low fabrication cost, facile operation, and quick response times. Microfluidic platforms are expected to effectively interpret both wanted and unwanted phenomena; however, a comprehensive evaluation of the unwanted phenomena has not been appropriately investigated in the literature. This work explored an attenuative evaluation of unwanted phenomena, also called here as secondary phenomena, in a unique approach.
Upon electric field utilization within microfluidic devices, electrode miniaturization improves device sensitivity. However, electrodes in contact with medium solution can yield byproducts that can …
Estimation Of Multi-Directional Ankle Impedance As A Function Of Lower Extremity Muscle Activation, Lauren Knop
Estimation Of Multi-Directional Ankle Impedance As A Function Of Lower Extremity Muscle Activation, Lauren Knop
Dissertations, Master's Theses and Master's Reports
The purpose of this research is to investigate the relationship between the mechanical impedance of the human ankle and the corresponding lower extremity muscle activity. Three experimental studies were performed to measure the ankle impedance about multiple degrees of freedom (DOF), while the ankle was subjected to different loading conditions and different levels of muscle activity. The first study determined the non-loaded ankle impedance in the sagittal, frontal, and transverse anatomical planes while the ankle was suspended above the ground. The subjects actively co-contracted their agonist and antagonistic muscles to various levels, measured using electromyography (EMG). An Artificial Neural Network …
A Smart Implantable Bone Fixation Plate Providing Actuation And Load Monitoring For Orthopedic Fracture Healing, Brad Nelson
A Smart Implantable Bone Fixation Plate Providing Actuation And Load Monitoring For Orthopedic Fracture Healing, Brad Nelson
Dissertations, Master's Theses and Master's Reports
Fracture non-union occurs in roughly 5-10% of all fracture cases, and current interventions are both time-consuming and costly. There is therefore significant incentive to develop new tools to improve fracture healing outcomes. Several studies have shown that low-magnitude, high-frequency (LMHF) mechanical loading can promote faster healing and reduce the risk of refracture in critical-size long bone fractures. This is typically done using whole-body vibration, which may result in undesirable systemic effects on the rest of the body. This work discusses an implantable piezoelectric fixation plate that can both apply LMHF loading directly to the fracture site using flexible scheduling and …
Development Of An Impedance-Controlled Hot Snare Polypectomy Device To Minimize Tissue Damage, Curtislee Thornton
Development Of An Impedance-Controlled Hot Snare Polypectomy Device To Minimize Tissue Damage, Curtislee Thornton
College of Graduate Studies: Theses & Dissertations
This study explores the ability to measure the changing impedance, ex vivo, of a porcine colon sample while undergoing a high-frequency alternating current from an Olympus PSD-30 electrosurgical unit and stop the applied current before excessive tissue damage ensues. The causes of the thermal damage are first examined, followed by the construction and testing of the impedance-controlled feedback device. Perforation was observed to occur when the impedance of the tissue sample increased by 25% or more. Using this information, the device was tested for five power settings ranging from 10W-50W. In each trial, the feedback device stopped the applied current …
Development Of An Eye Movement Based Predictive Model For Discrimination Of Parkinson's Disease From Other Parkinsonisms And Controls, Mary Anisa Kannan
Development Of An Eye Movement Based Predictive Model For Discrimination Of Parkinson's Disease From Other Parkinsonisms And Controls, Mary Anisa Kannan
Theses and Dissertations
Purpose: Due to the neurological aspects of Parkinson’s Disease (PD) and the sensitivity of eye movements to neurological issues, eye tracking has the potential to be an objective biomarker with higher accuracy in diagnosis than current clinical standards. Currently when PD is diagnosed clinically, there is an accuracy of 74% when diagnosed by a general practitioner and 82% when diagnosed by a movement disorder specialist. This study was designed to: 1. Assess eye movements as a potential biomarker for Parkinson’s Disease. 2. Determine if eye movements can distinguish between Parkinson’s Disease and commonly confounded movement disorders with parkinsonian symptoms. 3. …
Assessment Of Access Methods For Mobile Maps For Individuals Who Are Blind Or Visually Impaired, David Parker
Assessment Of Access Methods For Mobile Maps For Individuals Who Are Blind Or Visually Impaired, David Parker
Theses and Dissertations
When people go to a mall, museums, or other such locations they tend to rely on maps to find their way around. However, for people who are blind or visually impaired (BVI) maps are not easily accessible and they depend on other means, such as a guide, to get around. Research has only just begun to investigate providing maps for people who are BVI on touch screen devices. Many different types of feedback have been used: audio (sound), tactile (touch), audio-tactile, and multitouch. Some research has been conducted on the benefit of using multiple fingers (multitouch) and has found conflicting …
Assessing Endothelial Dysfunction Estimating The Differences Between 3 Minute And 5 Minute Reactive Hyperemia, Tamiko K. Saldin
Assessing Endothelial Dysfunction Estimating The Differences Between 3 Minute And 5 Minute Reactive Hyperemia, Tamiko K. Saldin
Master's Theses
The purpose of this study was to define a lower standard cuff occlusion time to induce reactive hyperemia in assessing endothelial dysfunction. In this study, strong evidence was found by a novel technique that used oscillometric methods, which supported that 3 minute reactive hyperemia was sufficient to elicit a significant difference in arterial compliance from baseline. Twenty healthy Cal Poly students were assessed, (n=12 female, n=8 male) aged 22 years old with a standard deviation of 2.04 years. Arterial compliance was estimated by measuring the peak-to-peak oscillations for baseline, 3 minute reactive hyperemia, and 5 minute reactive hyperemia tests, with …
Multiscale Mathematical Modelling Of Nonlinear Nanowire Resonators For Biological Applications, Rosa Fallahpourghadikolaei
Multiscale Mathematical Modelling Of Nonlinear Nanowire Resonators For Biological Applications, Rosa Fallahpourghadikolaei
Theses and Dissertations (Comprehensive)
Nanoscale systems fabricated with low-dimensional nanostructures such as carbon nanotubes, nanowires, quantum dots, and more recently graphene sheets, have fascinated researchers from different fields due to their extraordinary and unique physical properties. For example, the remarkable mechanical properties of nanoresonators empower them to have a very high resonant frequency up to the order of giga to terahertz. The ultra-high frequency of these systems attracted the attention of researchers in the area of bio-sensing with the idea to implement them for detection of tiny bio-objects. In this thesis, we originally propose and analyze a mathematical model for nonlinear vibrations of nanowire …