Wearable Hearing Accessory Technology, Tyler Cindea, Jaime Alcorn, Brooke Draper, Kyle Glascott, Ben Hanna, Robert Thoerner Jan 2018

Wearable Hearing Accessory Technology, Tyler Cindea, Jaime Alcorn, Brooke Draper, Kyle Glascott, Ben Hanna, Robert Thoerner

Williams Honors College, Honors Research Projects

We set out in August 2017 to develop an active noise suppressing device that would be usable both in military and civilian activities. Due to constraints in knowledge and time, we decided our best course of action was to divide the project into two equal projects with the hope to be able to combine them into a single project at the end of the allotted time. This consisted of an active noise suppression device and a passive noise suppression device. The passive device would have no electronic components and the active device would be pure circuitry with no housing. This …


Studying Mass And Mechanical Property Changes During The Degradation Of A Bioadhesive With Mass Tracking, Rheology And Magnetoelastic (Me) Sensors, Zhongtian Zhang Jan 2018

Studying Mass And Mechanical Property Changes During The Degradation Of A Bioadhesive With Mass Tracking, Rheology And Magnetoelastic (Me) Sensors, Zhongtian Zhang

Dissertations, Master's Theses and Master's Reports

In this research, the degradable polymer 4-arm poly (ethylene glycol)-glutaric acid-dopamine (PEG-GA-DM4) was synthesized. The degradation behavior of crosslinked PEG-GA-DM4 bioadhesive was studied with mass tracking, oscillatory rheology, and magnetoelastic (ME) sensors. Changes in mechanical properties were correlated with both dry mass and wet mass changes during the degradation. The results indicate that the loss of mechanical property in the bioadhesive can take place without losing the dry mass. The mass loss profile cannot describe the degradation behavior completely. In addition to studying the degradation of PEG-GA-DM4, this research also confirms the application of ME …


Collective Chemotaxis Of Retinal Neural Cells From Drosophila Melanogaster In Controlled Microenvironments, Stephanie Zhang Jan 2018

Collective Chemotaxis Of Retinal Neural Cells From Drosophila Melanogaster In Controlled Microenvironments, Stephanie Zhang

Dissertations and Theses

More than 172 million people are influenced by a retinal disorder that stems from either age-related or developmental causes. Of those, 1.5 million people endure a developmental retinal disorder. In the developing retina, neural cells undergo a series of highly complicated differentiation and migration process. A main cause of these diseases is abnormal collective migration of neural progenitors hindering the retinogenesis process. However, our grasp of collective migration and signaling molecules, critical to the developing retina, is incompletely understood. Understanding the molecular mechanisms, such as the fibroblast growth factor pathway, that regulate glial and neuronal migration provides decisive insights in …


Review Of Emerging Approaches In Non- Or Minimally Invasive Glucose Monitoring And Their Application To Physiological Human Body Fluids, Sunghoon Jang, Chen Xu Jan 2018

Review Of Emerging Approaches In Non- Or Minimally Invasive Glucose Monitoring And Their Application To Physiological Human Body Fluids, Sunghoon Jang, Chen Xu

Publications and Research

The frequent blood glucose monitoring by the diabetics and physicians is a very essential step in the management of the diabetes because this devastating disease can lead the patients to blindness, kidney disease, nervous & circulatory system disease, limb amputations, stroke and cardiovascular disease (CVD). There have been numerous attempts to develop viable painless non- or minimally invasive blood glucose monitoring techniques over the last five decades in order to replace all existing methods of home blood glucose monitoring require drawing a blood sample by piercing the skin. This review describes the principles of two main emerging general technologies such …


Power Mobility Sensor Data Collection Verified Through Standardized Pediatric Assessments, Ayshka Elise Rodriguez-Velez Jan 2018

Power Mobility Sensor Data Collection Verified Through Standardized Pediatric Assessments, Ayshka Elise Rodriguez-Velez

UNF Graduate Theses and Dissertations

The collaboration between the School of Engineering and the Department of Physical Therapy at the University of North Florida has introduced the possibility of creating a new environment for pediatric physical therapy assessments. There are currently no methods for remotely monitoring children with impairments. However, with embedded sensor technology in the form of power mobility and accepted therapy assessment tools, remote monitoring can become a possibility. As a part of this work, a ride-on toy car was developed as a remote monitoring device and a case study with a child with a mobility impairment was used as a proof of …


Reducing Uncertainty In Head And Neck Radiotherapy With Plastic Robotics, Mark R. Ostyn Jan 2018

Reducing Uncertainty In Head And Neck Radiotherapy With Plastic Robotics, Mark R. Ostyn

Theses and Dissertations

One of the greatest challenges in achieving accurate positioning in head and neck radiotherapy is that the anatomy at and above the cervical spine does not act as a single, mechanically rigid body. Current immobilization techniques contain residual uncertainties that are especially present in the lower neck that cannot be reduced by setting up to any single landmark. The work presented describes the development of a radiotherapy friendly mostly-plastic 6D robotic platform for positioning independent landmarks, (i.e., allowing remote, independent positioning of the skull relative to landmarks in the thorax), including analysis of kinematics, stress, radiographic compatibility, trajectory planning, physical …