Full-Text Articles in Biomedical Devices and Instrumentation

The Smart Hard Hat, Darcy Fyffe, Connor Langenderfer, Charlton Johns Jan 2016

The Smart Hard Hat, Darcy Fyffe, Connor Langenderfer, Charlton Johns

Williams Honors College, Honors Research Projects

In a wide variety of manual labor industries, workers are often unaware that they are approaching dangerous vital thresholds until they have already overexerted themselves. According to a 2012 white paper by the Occupational Safety and Health Administration (OSHA), over 4,500 workers lose their lives, and more than 4 million are seriously injured each year. There is an immediate need to improve the safety and monitoring of manual workers to reduce the number of workplace injuries and fatalities. Millions of laborers around the globe go to work every day relying on basic safety devices, such as harnesses and steel toed …


Reducing Fretting Corrosion At The Femoral Neck To Taper Junction In Total Hip Arthroplasty, Andrea M. Carly, Nicholas S. Moyer, Abel S. Pietros Jan 2016

Reducing Fretting Corrosion At The Femoral Neck To Taper Junction In Total Hip Arthroplasty, Andrea M. Carly, Nicholas S. Moyer, Abel S. Pietros

Williams Honors College, Honors Research Projects

Fretting corrosion due to micromotion between the femoral head and neck of hip implants is a growing concern of surgeons and patients. Debris from corrosion can lead to severe adverse effects for patients of total hip arthroplasty and reduce the lifespan of the product. Previous studies conducted by Zimmer Biomet show a connection between higher impaction force and reduced fretting corrosion and debris. This design project explored this issue and developed a training device using a current technology, a dynamic force sensor, and data analysis software for surgeons to obtain muscle memory of a 4kN strike on the head impactor, …


Pediatric Electrical Stimulation For Limb Lengthening: A Non-Invasive Approach, Corey J. Schurko, Sofia Chinchilla, Amanda E. Pinheiro, Jacob A. Brock Jan 2016

Pediatric Electrical Stimulation For Limb Lengthening: A Non-Invasive Approach, Corey J. Schurko, Sofia Chinchilla, Amanda E. Pinheiro, Jacob A. Brock

Williams Honors College, Honors Research Projects

Leg Length Discrepancy (LLD) is a problematic ailment for children as the differences in limb lengths can lead to scoliosis, hip, knee, and ankle problems, and back pain. If LLD is untreated, the symptoms will worsen as the child matures. Today LLD is corrected by using the Ilizarov Method, which uses pins that are externally attached to the broken bone for extension over time using a fixator or by using internal plates that do not require externalization. In our project we aim to use external electrical stimulation to correct the limb discrepancies. Several companies, such as Zimmer Biomet, have created …


Emlighten, Emily Mulvany Jan 2016

Emlighten, Emily Mulvany

Williams Honors College, Honors Research Projects

This project is focused on creating a system to increase patient satisfaction in hospitals. My senior design team has been working hand in hand with the emergency department of Akron General to design this system called EMlighten. The goal is to create an experience for patients where they exit the hospital feeling more satisfied than they currently are. Patient satisfaction is a key performance indicator used by many hospitals to determine how much additional funding each hospital department is granted. If patients feel more satisfied, not only is that indicative of better care, but departments will receive extra funding. EMlighten …


Hydroband: The Continuous Hydration Monitoring System, Karina E. Atkinson, Catherine P. Benedict Jan 2016

Hydroband: The Continuous Hydration Monitoring System, Karina E. Atkinson, Catherine P. Benedict

Williams Honors College, Honors Research Projects

Dehydration is defined as a mild, moderate, or extreme loss of water in the body. It can result in fever, muscle cramps, headaches, dizziness, or heat stroke in athletes. Ways to determine hydration levels include analysis of the urine, blood, or sweat, body weight changes, skin elasticity tests, and increases in core temperature. Patent search, research journals, and outside studies in the health and fitness market showed that a convenient and continuous hydration monitoring system was not available. Changes in core body temperature proved to be the quickest way to measure hydration levels. The HydroBand system is geared towards athletes …


Design And Development Of Optical Elastography Setup, Abhinav Madhavachandran Jan 2016

Design And Development Of Optical Elastography Setup, Abhinav Madhavachandran

Dissertations, Master's Theses and Master's Reports

The mechanical properties of the skin are an indication of its physiological condition. The properties can serve as potential information for dermatologists for diagnosis and qualitative assessment. Elastography is a medical imaging modality developed to extract the elastic properties of a tissue by application of an external force. Optical elastography is a technique of elastography which uses laser speckle tracking to study the elastic properties of several soft tissue including skin.

This work is aimed at developing an optical elastography setup that can study the elastic properties of skin. The setup includes an imaging system and a force-application system controlled …


Analysis Of Vocal Fold Kinematics Using High Speed Video, Harikrishnan Unnikrishnan Jan 2016

Analysis Of Vocal Fold Kinematics Using High Speed Video, Harikrishnan Unnikrishnan

Theses and Dissertations--Electrical and Computer Engineering

Vocal folds are the twin in-folding of the mucous membrane stretched horizontally across the larynx. They vibrate modulating the constant air flow initiated from the lungs. The pulsating pressure wave blowing through the glottis is thus the source for voiced speech production. Study of vocal fold dynamics during voicing are critical for the treatment of voice pathologies. Since the vocal folds move at 100 - 350 cycles per second, their visual inspection is currently done by strobosocopy which merges information from multiple cycles to present an apparent motion. High Speed Digital Laryngeal Imaging(HSDLI) with a temporal resolution of up to …


Assessment Of Optimized Electrode Configuration In Electrical Impedance Myography Study Using Genetic Algorithm Via Finite Element Model, Somen Baidya Jan 2016

Assessment Of Optimized Electrode Configuration In Electrical Impedance Myography Study Using Genetic Algorithm Via Finite Element Model, Somen Baidya

College of Graduate Studies: Theses & Dissertations

Electrical Impedance Myography (EIM) is a neurophysiologic technique in which high- frequency, low-intensity electrical current is applied via surface electrodes over a muscle or muscle group of interest and the resulting electrical parameters (resistance, reactance and phase) are analyzed to isolate diseased muscles from healthy ones. Beside muscle properties, some other anatomic and non-anatomic factors like muscle shape, subcutaneous fat (SF) thickness, inter-electrode distance, etc. also impact the major EIM parameters and thus affect the EIM analysis outcomes. The purpose of this study is to explore the effects of variation in some of these factors impose on EIM parameters and …


Impairment Of Continuous Insulin Delivery Therapy And Analysis From Graeco-Latin Square Design Model, Norou Diawara, Ayodeji Demuren, Eric Gyuricsko Jan 2016

Impairment Of Continuous Insulin Delivery Therapy And Analysis From Graeco-Latin Square Design Model, Norou Diawara, Ayodeji Demuren, Eric Gyuricsko

Mathematics & Statistics Faculty Publications

The desire to deliver measured amount of insulin continuously to patients with type I diabetes, for glycemic control, has attracted a lot of attention. Continuous subcutaneous insulin infusion has seen some success in recent years. However, occlusion of insulin delivery may prevent the patient from receiving the prescribed dosage, with adverse consequence. An in vitro study of insulin delivery is performed, using different insulin pumps, insulin analogs and operating conditions. The aim is to identify incidences of occlusion due to bubble formation in the infusion line. A detailed statistical analysis was performed on the data collected to determine any significant …