Open Access. Powered by Scholars. Published by Universities.®
Biomedical Devices and Instrumentation Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Medicine and Health Sciences (10)
- Electrical and Computer Engineering (7)
- Mechanical Engineering (7)
- Biomedical (6)
- Bioimaging and Biomedical Optics (5)
-
- Medical Specialties (5)
- Other Biomedical Engineering and Bioengineering (5)
- Biomaterials (4)
- Biomechanical Engineering (4)
- Chemical Engineering (4)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (3)
- Biochemical and Biomolecular Engineering (3)
- Bioelectrical and Neuroengineering (3)
- Life Sciences (3)
- Surgical Procedures, Operative (3)
- Cardiology (2)
- Cell and Developmental Biology (2)
- Computer Engineering (2)
- Computer Sciences (2)
- Electrical and Electronics (2)
- Medical Biotechnology (2)
- Medical Sciences (2)
- Microbiology (2)
- Molecular, Cellular, and Tissue Engineering (2)
- Neurology (2)
- Physical Sciences and Mathematics (2)
- Psychiatry (2)
- Institution
-
- University of Nebraska - Lincoln (8)
- California Polytechnic State University, San Luis Obispo (6)
- Kettering University (5)
- Marquette University (5)
- University of Arkansas, Fayetteville (5)
-
- Missouri University of Science and Technology (3)
- University of Kentucky (3)
- University of Nevada, Las Vegas (3)
- Minnesota State University, Mankato (2)
- Purdue University (2)
- City University of New York (CUNY) (1)
- Cleveland State University (1)
- Syracuse University (1)
- The Texas Medical Center Library (1)
- University of Arkansas Little Rock (1)
- Virginia Commonwealth University (1)
- Western Michigan University (1)
- Keyword
-
- Artery (2)
- Fracture (2)
- Hypertension (2)
- Kinematics (2)
- Mechanical stimuli (2)
-
- Medical Devices (2)
- Remodeling (2)
- Tissue mechanics (2)
- Wall stress (2)
- 3D Printing (1)
- Accident prevention (1)
- Accidents (1)
- Activities of Daily Living (1)
- Actuators (1)
- Angle Stable (1)
- Aptamer (1)
- Articular joint replacements (1)
- Artificial Gravity (1)
- Artificial Implants (1)
- Artificial implants (1)
- Artificial muscle (1)
- Automated device (1)
- Avian Influenza Virus H5N1 (1)
- Beamforming Optimization (1)
- Biocompatible (1)
- Biodetection (1)
- Biomaterials (1)
- Biomechanics (1)
- Biomedical Imaging (1)
- Biomimetics (1)
- Publication
-
- Graduate Theses and Dissertations (5)
- Master's Theses (2009 -) (4)
- Chemical and Biochemical Engineering Faculty Research & Creative Works (3)
- Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research (3)
- Master's Theses (3)
-
- Theses and Dissertations--Biomedical Engineering (3)
- UNLV Theses, Dissertations, Professional Papers, and Capstones (3)
- Biomedical Engineering (2)
- Department of Mechanical and Materials Engineering: Faculty Publications (2)
- Journal of Undergraduate Research at Minnesota State University, Mankato (2)
- Mechanical Engineering Patents (2)
- Mechanical Engineering Publications (2)
- The Summer Undergraduate Research Fellowship (SURF) Symposium (2)
- Theses and Dissertations (2)
- Chemical Engineering Patents (1)
- Computer Engineering (1)
- Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research (1)
- Department of Psychology: Faculty Publications (1)
- Dissertations (1934 -) (1)
- Dissertations and Theses (Open Access) (1)
- Honors Theses (1)
- Publications and Research (1)
- Renée Crown University Honors Thesis Projects - All (1)
- School of Computing: Conference and Workshop Papers (1)
- Undergraduate Research Posters 2014 (1)
- Publication Type
Articles 31 - 49 of 49
Full-Text Articles in Biomedical Devices and Instrumentation
Design And Validation Of A Wearable, Continuous, And Non-Invasive Hydration Monitor That Uses Ultrasonic Pulses To Detect Changes In Tissue Hydration Status, Zoie Engman
Master's Theses
Chronic dehydration is an endemic problem for many population groups. Current methods of monitoring hydration status are invasive, time consuming, cannot be performed while exercising, and require lab resources. A proposed solution is a wearable, continuous, and non-invasive device that uses harm-free ultrasonic pulses to detect changes in tissue hydration status over time. Customer and engineering requirements were defined and used to guide the design process. Literature reviews were performed to identify essential information on dehydration, assess current methods, discover state of the art devices, and describe ultrasonic theory. Market research was performed to identify athletes as the target population …
Team Omnimouse, Derek J. Halman, Josh B. Porter, Steven A. Silver, Ian S. Stemper
Team Omnimouse, Derek J. Halman, Josh B. Porter, Steven A. Silver, Ian S. Stemper
Computer Engineering
INFORMATION, DATA, FIGURES AND DRAWINGS EMBODIED IN THIS DOCUMENT ARE STRICTLY CONFIDENTIAL AND ARE SUPPLIED ON THE UNDERSTANDING THAT THEY WILL NOT BE DISCLOSED TO THIRD PARTIES WITHOUT THE PRIOR WRITTEN CONSENT OF QUALITY OF LIFE PLUS.
Sonar For The Visually Impaired, Anastasia Newark, Edwin Ng, Scott Terhorst
Sonar For The Visually Impaired, Anastasia Newark, Edwin Ng, Scott Terhorst
Biomedical Engineering
There are currently no inexpensive assistive devices that allow the visually impaired detect low hanging objects that are above waist height and may cause injury, such as a rope or tree branch. The challenge presented to the team by the Quality of Life Plus Lab (QL+) was to develop a Sonar Cane device that attaches to a traditional white cane to address this problem. This device must be lightweight, inexpensive to manufacture, have a long battery life, and accurately detect obstacles to prevent user injury.
A Study Of Ciliary Beating In Chlamydomonas, Xin Li
A Study Of Ciliary Beating In Chlamydomonas, Xin Li
Renée Crown University Honors Thesis Projects - All
The goal of this research is to understand how a unicellular green alga, Chlamydomonas-reinhardtii, responds to red light (670nm) and sound waves, by monitoring the beating frequency of its two cilia, which control cell motility. Ciliary beating frequency (BF) is proportional to the production of ATP, mainly generated by photosynthesis. A photosynthesis inhibitor, 3-(3-, 4-dichlorophenyl)-1, 1-dimethylurea (DCMU) decreases ATP production by photosynthesis. I used DCMU as a tool to analyze the red light effect on BF.
In the process of studying the effect of red light, I unexpectedly discovered experimental conditions for unstable ciliary beating (as shown in the video). …
Development Of A Multi-Purpose Automated Synthesis Module For Production Of Novel Pet Radiopharmaceuticals, I Hong Shih
Development Of A Multi-Purpose Automated Synthesis Module For Production Of Novel Pet Radiopharmaceuticals, I Hong Shih
Dissertations and Theses (Open Access)
Among radiopharmaceuticals of positron emission tomography (PET), 18F-Fluorodeoxyglucose (18F-FDG) made from commercialized automated synthesis module is the most frequently used in tumor diagnoses. But the false positive findings, such as infectious tissues and post-operative surgical conditions, show strong uptake of 18F-FDG in PET scans which requires extra clinical procedures to confirm the results. Moreover, the false negative findings, such as low glycolytic activity tumors, reduce the accuracy of PET scans. Therefore, there will be new PET radiopharmaceuticals to redeem the defects of 18FDG-PET applications.
Current commercialized automated synthesis modules are suitable for clinical use, but …
Subtalar Fusion Fixture Design And Test, Nathan Ortiz
Subtalar Fusion Fixture Design And Test, Nathan Ortiz
Honors Theses
Subtalar arthrodesis is performed when cartilage in the talo-calcaneal (the ankle) joint is degraded in a patient and there are multiple approaches to this surgery. Using synthetic bone material, fixtures were cast from aluminum, using the process of evaporation pattern casting, and epoxy. This casting was used to grip the calcaneus bone of the foot in order to load it mechanically, simulating different scenarios that would be encountered during walking. The relative displacement of the ankle joint was measured using a digital image correlation (DIC) program that was modified to work in both two- and three-dimensional space. This program can …
Computational Evaluation Of Shear Stress And Restenosis In Stented Coronary Arteries Using Optical Coherence Tomography, Joshua K. Hughey
Computational Evaluation Of Shear Stress And Restenosis In Stented Coronary Arteries Using Optical Coherence Tomography, Joshua K. Hughey
Master's Theses (2009 -)
The cause of coronary artery neointimal thickness (NT) leading to restenosis in ~10% of drug-eluting stents (DES) is unknown, but adverse wall shear stress (WSS) may contribute. Prior studies comparing WSS to restenosis for first generation DES yielded conflicting results, and cited different mechanisms of action for DES agents. Studies to date have not accounted for stent geometry, which dictates local WSS patterns influencing drug concentration. The objective of this investigation was to evaluate current generation stent platforms via their WSS patterns and their respective impact on NT. We prospectively enrolled 19 patients, who were randomized to thin-strut (81μm) 2-link …
Markerless Analysis Of Upper Extremity Kinematics During Standardized Pediatric Assessment, Jacob R. Rammer
Markerless Analysis Of Upper Extremity Kinematics During Standardized Pediatric Assessment, Jacob R. Rammer
Master's Theses (2009 -)
Children with hemiplegic cerebral palsy experience reduced motor performance in the affected upper extremity and are typically evaluated based on degree of functional impairment using activity-based assessments such as the Shriners Hospitals for Children Upper Extremity Evaluation (SHUEE), a validated clinical measure, to describe performance prior to and following rehabilitative or surgical interventions. Evaluations rely on subjective therapist scoring techniques and lack sensitivity to detect change. Objective clinical motion analysis systems are an available but time-consuming and cost-intensive alternative, requiring uncomfortable application of markers to the patient. There is currently no available markerless, low-cost system that quantitatively assesses upper extremity …
Design Of Controlled Environment For Tissue Engineering, Malcolm Gerald Lapera
Design Of Controlled Environment For Tissue Engineering, Malcolm Gerald Lapera
Master's Theses
Design of Controlled Environment for Tissue Engineering
Malcolm Lapera
Tissue engineering aims at relieving the need for donor tissue and organs by developing a process of creating viable tissues in the laboratory setting. With over 120,000 people awaiting a transplant, the need for generating tissue engineered organs is very large [3]. In order for organs to be engineered, a few issues need to be overcome. A work space that both creates an environment which maintains cell viability over an extended period of time as well as accommodates the necessary fabrication equipment will be needed to further tissue engineering research. Therefore, …
Utilizing Fast Spin Echo Mri To Reduce Image Artifacts And Improve Implant/Tissue Interface Detection In Refractory Parkinson’S Patients With Deep Brain Stimulators, Subhendra N. Sarkar, Pooja R. Sarkar, Efstathios Papavassiliou, Rafael Rojas
Utilizing Fast Spin Echo Mri To Reduce Image Artifacts And Improve Implant/Tissue Interface Detection In Refractory Parkinson’S Patients With Deep Brain Stimulators, Subhendra N. Sarkar, Pooja R. Sarkar, Efstathios Papavassiliou, Rafael Rojas
Publications and Research
Introduction. In medically refractory Parkinson’s disease (PD) deep-brain stimulation (DBS) is an effective therapeutic tool. Postimplantation MRI is important in assessing tissue damage and DBS lead placement accuracy. We wanted to identify which MRI sequence can detectDBS leads with smallest artifactual signal void, allowing better tissue/electrode edge conspicuity.
Methods. Using an IRB approved protocol 8 advanced PDpatientswere imagedwithinMRconditional safety guidelines at lowRF power (SAR ≤ 0.1 W/kg) in coronal plane at 1.5T by various sequences.The image slices were subjectively evaluated for diagnostic quality and the lead contact diameters were compared to identify a sequence least affected by metallic leads.
Results …
Head Impact Exposure In Male And Female Collegiate Ice Hockey Players, Bethany J. Wilcox, Jonathan G. Beckwith, Richard M. Greenwald, Jeffrey J. Chu, Thomas W. Mcallister, Laura A. Flashman, Arthur C. Maerlender, Ann-Christine Duhaime, Joseph J. Crisco
Head Impact Exposure In Male And Female Collegiate Ice Hockey Players, Bethany J. Wilcox, Jonathan G. Beckwith, Richard M. Greenwald, Jeffrey J. Chu, Thomas W. Mcallister, Laura A. Flashman, Arthur C. Maerlender, Ann-Christine Duhaime, Joseph J. Crisco
Department of Psychology: Faculty Publications
The purpose of this study was to quantify head impact exposure (frequency, location and magnitude of head impacts) for individual male and female collegiate ice hockey players and to investigate differences in exposure by sex, player position, session type, and team. Ninety-nine (41 male, 58 female) players were enrolled and 37,411 impacts were recorded over three seasons. Frequency of impacts varied significantly by sex (males: 287 per season, females: 170, p < 0.001) and helmet impact location (p < 0.001) but not by player position (p = 0.088). Head impact frequency also varied by session type; both male and female players sustained more impacts in games than in practices (p < 0.001), however the magnitude of impacts did not differ between session types. There was no difference in 95th percentile peak linear acceleration between sexes (males: 41.6 g, females: 40.8 g), but 95th percentile peak rotational acceleration and HITsp (a composite severity measure) were greater for males than females (4424, 3409 rad/s2, and 25.6, 22.3, respectively). Impacts to the back of the helmet resulted in the greatest 95th percentile peak linear accelerations for males (45.2 g) and females (50.4 g), while impacts to the side and back of the head were associated with the greatest 95th percentile peak rotational accelerations (males: 4719, 4256 rad/sec2, females: 3567, 3784 rad/sec2, respectively). It has been proposed that reducing an individual’s head impact exposure is a practical approach for reducing the risk of …
Microsphere Spray System For Wound Coverage, Nicholas J. Andersen
Microsphere Spray System For Wound Coverage, Nicholas J. Andersen
Theses and Dissertations--Biomedical Engineering
Spinal fusion is used to treat diseases or disorders of the spine by fusing together two or more vertebrae. Two associated risks with spinal fusion are infection and blood loss. Administration of tranexamic acid is used to prevent blood loss, and transfusions are given following blood loss. Surgical site infections are prevented with vancomycin powder spread into the surgical wound, while established infections are treated by debridement and delivery of antibiotics for 4 to 6 weeks. The present research explored an alternate method to prevent and treat blood loss or infection in spinal fusion. Poly(lactic-co-glycolic acid) (PLGA) microspheres was used …
Novel Technologies For The Detection And Mitigation Of Drowsy Driving, Samuel Lawoyin
Novel Technologies For The Detection And Mitigation Of Drowsy Driving, Samuel Lawoyin
Theses and Dissertations
In the human control of motor vehicles, there are situations regularly encountered wherein the vehicle operator becomes drowsy and fatigued due to the influence of long work days, long driving hours, or low amounts of sleep. Although various methods are currently proposed to detect drowsiness in the operator, they are either obtrusive, expensive, or otherwise impractical. The method of drowsy driving detection through the collection of Steering Wheel Movement (SWM) signals has become an important measure as it lends itself to accurate, effective, and cost-effective drowsiness detection. In this dissertation, novel technologies for drowsiness detection using Inertial Measurement Units (IMUs) …
A Method To Modify Angle-Stable Intramedullary Nail Construct Compliance, Patrick Atkinson, B. P. Flanagan, D. Lecronier, M. R. Kubacki, P. Telehowski
A Method To Modify Angle-Stable Intramedullary Nail Construct Compliance, Patrick Atkinson, B. P. Flanagan, D. Lecronier, M. R. Kubacki, P. Telehowski
Mechanical Engineering Publications
Traditional interlocked intramedullary (IM) nails have recently been modified to provide enhanced angular stability. These so-called ‘angle-stable’ IM nails are designed to eliminate construct toggle and also provide increased axial, bending, and torsional stiffness. While this added stability is needed for small fracture gaps to heal, angle-stable nails may be too stiff for large fracture gaps to unite. Even though relative stability is recommended for large fracture gaps, recent in vivo data indicates that traditional nails may allow for too much motion for healing to occur. The current study evaluated a modified technique for implanting an angle-stable nail which allows …
Biomechanical Performance Of Variable And Fixed Angle Locked Volar Plates For The Dorsally Comminuted Distal Radius, Patrick Atkinson, D. Martineau, J. Shorez, C. Beran, A. G. Dass
Biomechanical Performance Of Variable And Fixed Angle Locked Volar Plates For The Dorsally Comminuted Distal Radius, Patrick Atkinson, D. Martineau, J. Shorez, C. Beran, A. G. Dass
Mechanical Engineering Publications
Background
The ideal treatment strategy for the dorsally comminuted distal radius fracture continues to evolve. Newer plate designs allow for variable axis screw placement while maintaining the advantages of locked technology. The purpose of this study is to compare the biomechanical properties of one variable axis plate with two traditional locked constructs.
Methods
Simulated fractures were created via a distal 1 cm dorsal wedge osteotomy in radius bone analogs. The analogs were of low stiffness and rigidity to create a worst-case strength condition for the subject radius plates. This fracture-gap model was fixated using one of three different locked volar …
Human Cardiovascular Responses To Artificial Gravity Variables: Ground-Based Experimentation For Spaceflight Implementation, Mark Howarth
Human Cardiovascular Responses To Artificial Gravity Variables: Ground-Based Experimentation For Spaceflight Implementation, Mark Howarth
Theses and Dissertations--Biomedical Engineering
One countermeasure to cardiovascular spaceflight deconditioning being tested is the application of intermittent artificial gravity provided by centripetal acceleration of a human via centrifuge. However, artificial gravity protocols have not been optimized for the cardiovascular system, or any other physiological system for that matter. Before artificial gravity protocols can be optimized for the cardiovascular system, cardiovascular responses to the variables of artificial gravity need to be quantified.
The research presented in this document is intended to determine how the artificial gravity variables, radius (gravity gradient) and lower limb exercise, affect cardiovascular responses during centrifugation. Net fluid (blood) shifts between body …
The Study Of Trunk Mechanical And Neuromuscular Behaviors, Brian D. Koch
The Study Of Trunk Mechanical And Neuromuscular Behaviors, Brian D. Koch
Theses and Dissertations--Biomedical Engineering
Low back pain (LBP) is a common ailment in the United States, affecting up to 80% of adults at least once in their lifetime. Although 90% of LBP cases are considered nonspecific, recent studies show that abnormal mechanics of the lower back can be a major factor. One method of assessing the lower back mechanical environment is through perturbation experiments. An intensive literature review of perturbation systems was used to select and develop a system for the Human Musculoskeletal Biomechanics Lab (HMBL). Following construction, individuals with high/low exposure to day-long physical activity were assessed to quantify daily changes in their …
Investigating The Effect Of Sio2-Tio2-Cao-Na 2o-Zno Bioactive Glass Doped Hydroxyapatite: Characterisation And Structural Evaluation, Chokchai Yatongchai, Anthony W. Wren, Declan J. Curran, Stuart Hampshire, Mark R. Towler
Investigating The Effect Of Sio2-Tio2-Cao-Na 2o-Zno Bioactive Glass Doped Hydroxyapatite: Characterisation And Structural Evaluation, Chokchai Yatongchai, Anthony W. Wren, Declan J. Curran, Stuart Hampshire, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
The effects of increasing bioactive glass additions,
SiO2-TiO2-CaO-Na2O-ZnO up to 25 wt% in increments of 5 wt%, on the physical and mechanical properties of hydroxyapatite (HA) sintered at 900, 1000, 1100 and 1200°C for 2 h was investigated. Increasing both the glass content and the temperature resulted in increased HA decomposition. This resulted in the formation of a number of bioactive phases. However the presence of the liquidus glass phase did not result in increased densification levels. At 1000 and 1100°C the additions of 5 wt% glass resulted in a decrease in density which …
Degradable Borate Glass Polyalkenoate Cements, L. Shen, A. Coughlan, Mark R. Towler, M. Hall
Degradable Borate Glass Polyalkenoate Cements, L. Shen, A. Coughlan, Mark R. Towler, M. Hall
Chemical and Biochemical Engineering Faculty Research & Creative Works
Glass polyalkenoate cements (GPCs) containing aluminum-free borate glasses having the general composition Ag2O-Na2O-CaO-SrO-ZnO- TiO2-B2O3 were evaluated in this work. An initial screening study of sixteen compositions was used to identify regions of glass formation and cement compositions with promising rheological properties. The results of the screening study were used to develop four model borate glass compositions for further study. A second round of rheological experiments was used to identify a preferred GPC formulation for each model glass composition. The model borate glasses containing higher levels of TiO2 (7.5 mol %) …