Full-Text Articles in Biomedical Devices and Instrumentation

High Power, Low Frequency Ultrasound: Meniscal Tissue Interaction And Ablation Characteristics, Brendan O'Daly, Edmund Morris, Graham Gavin, Conor Keane, John O Byrne, Garrett Mcguinness Jan 2011

High Power, Low Frequency Ultrasound: Meniscal Tissue Interaction And Ablation Characteristics, Brendan O'Daly, Edmund Morris, Graham Gavin, Conor Keane, John O Byrne, Garrett Mcguinness

Articles

Abstract—This study evaluates high power low frequency ultrasound transmitted via a flat vibrating probe tip as an alternative technology for meniscal debridement in the bovine knee. An experimental force controlled testing rig was constructed using a 20 kHz ultrasonic probe suspended vertically from a load cell. Effect of variation in amplitude of distal tip displacement (242–494 mm peak-peak) settings and force (2.5–4.5 N) on tissue removal rate (TRR) and penetration rate (PR) for 52 bovine meniscus samples was analyzed. Temperature elevation in residual meniscus was measured by embedded thermocouples and histologic analysis. As amplitude or force increases, there is a …


Design, Fabrication, And Testing Of An Electrospinning Apparatus For The Deposition Of Pmma Polymer For Biomedical Applications, Harsha Malshe Jan 2011

Design, Fabrication, And Testing Of An Electrospinning Apparatus For The Deposition Of Pmma Polymer For Biomedical Applications, Harsha Malshe

Inquiry: The University of Arkansas Undergraduate Research Journal

This paper describes the successful design and fabrication of a deposition system for synthesis and assembly of nanoscale and submicron sized fibers of poly(methylmethacrylate)(PMMA) polymer. To optimize the electrospinning deposition process, the distance between the needle and the electrically grounded substrate, the applied voltage, and the concentration of PMMA polymer in the solution were varied. PMMA fibers as small as 500 nanometers were observed using scanning electron microscopy (SEM). The chemical signature of PMMA was confirmed for best quality and retention of chemistry using Fourier Transformed Infrared spectroscopy (FT-IR). PMMA is a biocompatible polymer, and nanofibers of PMMA are key …


In-Silico Hyperthermia Performance Of A Near-Field Patch Antenna At Various Positions On A Human Body Model, Sergio Curto, Terrence See, Patrick Mcevoy, Max Ammann, Zhi Ning Chen Jan 2011

In-Silico Hyperthermia Performance Of A Near-Field Patch Antenna At Various Positions On A Human Body Model, Sergio Curto, Terrence See, Patrick Mcevoy, Max Ammann, Zhi Ning Chen

Articles

A compact patch applicator designed to enhance targeted energy coupling at 434 MHz is a key enabler for sensitizing temperature increments in body regions containing superficial tumours. A detailed FDTD body model is used to explore simulated RF coupling and temperature increments for typical clinical conditions. The antenna impedance matching, specific absorption rate and thermal distribution parameters are evaluated to identify applied performance outcomes. The analysis reveals physiological-RF coupling patterns for an optimised closely-coupled single element applicator.


On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle Jan 2011

On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle

Conference Papers

Eye tracking is a well-established method of computer control for profoundly paralysed people (Anson et al., 2002). Cameras are commonly used to track eye movements (Morimoto et al., 2005) but one alternative is the bioelectrical signal known as the electrooculogram (EOG). There are some EOG mouse control systems that facilitate the use of GUI applications, but certain actions, which are straightforward using a conventional mouse, remain impossible. Unless the eyes are tracking a target, they move in saccades (jumps), making it impossible to voluntarily trace out smooth trajectories with one's gaze, as would be required to draw a smooth curve. …


Arterial Tissue Perforation Using Ultrasonically Vibrating Wire Waveguides, Mark Wylie Jan 2011

Arterial Tissue Perforation Using Ultrasonically Vibrating Wire Waveguides, Mark Wylie

Doctoral

Chronic Total Occlusions (CTOs) are fibrous and calcified atherosclerotic lesions which completely occlude the artery. They are difficult to treat with standard dilation procedures as they cannot be traversed easily. Their treatment is also associated with a high risk of arterial perforation. Low frequency ultrasonic vibrations delivered via wire waveguides represent a minimally invasive treatment for CTOs and other tissue ablation applications. These devices typically operate at 20–50 kHz delivering wire waveguide distal tip amplitudes of vibration of 0-60 μm. The diseased tissue is ablated or disrupted by repetitive direct mechanical contact and cavitation. This research assesses the susceptibility of …


The Bioactivity And Ion Release Of Titanium-Containing Glass Polyalkenoate Cements For Medical Applications, A. W. Wren, N. M. Cummins, F. R. Laffir, S. P. Hudson, Mark R. Towler Jan 2011

The Bioactivity And Ion Release Of Titanium-Containing Glass Polyalkenoate Cements For Medical Applications, A. W. Wren, N. M. Cummins, F. R. Laffir, S. P. Hudson, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

The ion release profiles and bioactivity of a series of Ti containing glass polyalkenoate cements. Characterization revealed each material to be amorphous with a Tg in the region of 650-660°C. The network connectivity decreased (1.83-1.35) with the addition of TiO2 which was also evident with analysis by X-ray photoelectron spectroscopy. Ion release from cements were determined using atomic absorption spectroscopy for zinc (Zn2+), calcium (Ca2+), strontium (Sr2+), Silica (Si4+) and titanium (Ti4+). Ions such as Zn2+ (0.1-2.0 mg/l), Ca2+ (2.0-8.3 mg/l,) Sr2+ (0.1-3.9 mg/l), and Si4+ …


The Response Of Pseudomonas Aeruginosa Biofilm To The Presence Of A Glass Polyalkenoate Cement Formulated From A Silver Containing Glass, A. Coughlan, M. P. Ryan, N. M. Cummins, Mark R. Towler Jan 2011

The Response Of Pseudomonas Aeruginosa Biofilm To The Presence Of A Glass Polyalkenoate Cement Formulated From A Silver Containing Glass, A. Coughlan, M. P. Ryan, N. M. Cummins, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

No abstract provided.