Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering

Discipline
Keyword
Publication Year

Articles 61 - 79 of 79

Full-Text Articles in Biomedical Devices and Instrumentation

Esophageal Mapping And Temperature Regulation For Catheter Ablation, Madison J. Keith, Morgan A. Jawitz, Sarah L. Sanders Mar 2019

Esophageal Mapping And Temperature Regulation For Catheter Ablation, Madison J. Keith, Morgan A. Jawitz, Sarah L. Sanders

Biomedical Engineering

The purpose of this document is to provide a development summary for a proposed esophageal temperature mapping device used during catheter ablation. Catheter ablation therapy is performed in the left atria with hot or cold materials to create scar tissue to treat atrial fibrillation. However, utilized temperatures and absorbed energies from the catheter can cause undesired esophageal damage. Therefore, this medical device is designed to monitor esophageal temperature and map its location during catheter ablation. If dangerous temperatures are reached, the device will alarm the surgeon.

This document provides an in-depth overview of the esophageal temperaturemapping device’s development and contains …


Fluid Delivery System For A Cell Culture On A Microfluidic Chip, Austin J. Roeder, Colleen A. Richards, Emily A. Matteson Mar 2019

Fluid Delivery System For A Cell Culture On A Microfluidic Chip, Austin J. Roeder, Colleen A. Richards, Emily A. Matteson

Biomedical Engineering

This project report provides a description of the progress made in the development of a fluid delivery system for a microfluidic cell culture on a chip. The system is intended to be used in a humidified incubator in a university laboratory and the fluid delivery system is required to exist and operate within that incubator for extended periods of time. Therefore, the system will be gravity-driven and contain no electronic components. The key specification of the system is to provide fluid flow at a constant velocity.

After manufacturing and testing the device, all specifications were met except for the fluid …


Pressure Cylinder Controlled Release Valve, Alexa Dominique Balbuena Mar 2019

Pressure Cylinder Controlled Release Valve, Alexa Dominique Balbuena

Biomedical Engineering

This project aims to integrate an automatic gas release system in a pre-existing scaffold fabrication process for tissue engineering applications.

To form the proper scaffold structure, the fabrication process is heavily influenced by the change in its surrounding pressure. The current production involves a pressure transducer and electric valve that is managed manually to create a suitable pressure environment for the scaffold. This method, although functional, proves to be ineffective when creating several batches; the user needs to constantly monitor the developing pressure profile and alter voltage parameters accordingly to create a linear gas release under a predetermined slope.

To …


Automated Microscope Stage, Corin Nishimoto, Alison Flesch, Theo Anastos Mar 2019

Automated Microscope Stage, Corin Nishimoto, Alison Flesch, Theo Anastos

Biomedical Engineering

This document seeks to describe the background information, customer requirements, design specifications, indications for use, selected materials, proposed budget, prototypes, final design, manufacturing processes, and testing methods regarding the CellOptimizer automated microscope stage product.


Slit Lamp Ophthalmoscope Redesign, Michael Hostetler, Austin Mattmiller, Alexis Brewer Mar 2019

Slit Lamp Ophthalmoscope Redesign, Michael Hostetler, Austin Mattmiller, Alexis Brewer

Biomedical Engineering

The slit lamp ophthalmoscope is used by ophthalmologists for diagnosis of pathologies in the eye. The device is used for identifying ocular diseases or indications of other possible systemic diseases to treat them before the diseases progress. Redesign of the ergonomics and adjustment mechanisms of the slit lamp ophthalmoscope will attempt to improve the compatibility of the device across a greater variety of patients. The wider headrest tower of 12.75 inches, the wider table cutout of 12 inches, and the 12 inches of extension of the headrest tower creates a better ergonomic fit for the patient and doctor. The wider …


Upright Sleep Device For Patients Required To Sleep Upright Post Surgery/Medical Procedure, Kristin J. Abele, Madeleine H. Hummel, Tayler R. Kastlunger Jan 2019

Upright Sleep Device For Patients Required To Sleep Upright Post Surgery/Medical Procedure, Kristin J. Abele, Madeleine H. Hummel, Tayler R. Kastlunger

Biomedical Engineering

No abstract provided.


Virtual Stethoscope/Otoscope Duo, Camila P. Monchini, Paige R. Mazur, Christian Navarro Mar 2018

Virtual Stethoscope/Otoscope Duo, Camila P. Monchini, Paige R. Mazur, Christian Navarro

Biomedical Engineering

The virtual stethoscope/otoscope duo is a medical device intended to allow patients to be seen by their medical provider via internet consultations from the comfort of their own home. This device allows patients to substitute in-person doctor visits by checking a patient’s cardiovascular, respiratory, and auditory health. This document is the statement of work for the virtual stethoscope/otoscope duo and contains information on similar products, patents, and relevant literatures containing virtual technologies that assist in patient diagnosis. Product specifications and other details for the device such as performance evaluation review techniques can also be found within this document outlining the …


Redesign Of The Medtronic Kyphon Bone Cement Mixer For Vertebral Compression Fractures, Mollie Benson, Sarah Freesemann, Aj Konnath, Benjamin Murray Jun 2017

Redesign Of The Medtronic Kyphon Bone Cement Mixer For Vertebral Compression Fractures, Mollie Benson, Sarah Freesemann, Aj Konnath, Benjamin Murray

Biomedical Engineering

The complete senior project report was submitted to the project advisor and sponsor. The results of this project are of a confidential nature and will not be published at this time.


Prosthetic Leg Kit For Deployment In Developing Countries, Brian Murphy, Dominique Porcincula, Derek Morgan, Kendall Ruggles, Christian Aguayo Jun 2016

Prosthetic Leg Kit For Deployment In Developing Countries, Brian Murphy, Dominique Porcincula, Derek Morgan, Kendall Ruggles, Christian Aguayo

Biomedical Engineering

The World Health Organization estimates that over 30 million people require some sort of prosthetic technology. However, traditional prosthetic fitting practices take a lot of time and cost a lot of money, making them inaccessible to millions of people around the world. StandUP Worldwide is an interdisciplinary project team devoted to creating low-cost prosthetic technologies for use around the world, especially in resource poor areas. They are currently developing a low cost, below-the-knee prosthetic kit that can be easily deployed in a resource-poor area. The following presents their solution for a below-the-knee prosthetic socket, foot, and leg.


The Effect Of Neurostimulation On Ischemic Pain And Methods Of Assessing Pain, Kaylee Keck Dec 2015

The Effect Of Neurostimulation On Ischemic Pain And Methods Of Assessing Pain, Kaylee Keck

Biomedical Engineering

Peripheral arterial disease (PAD) impacts approximately eight million people in the United States [1]. Disease progression leads to chronic ischemic pain, hindering quality of life. Pharmaceuticals are a typical treatment for pain associated with PAD; but as few as 30% of patients have a significant reduction of pain (≥50%) [2].

Neurostimulation is commonly used as a treatment for various diseases and injuries, including Parkinson’s disease and sports-related back and knee injuries [2]. The objective of the study was to explore neurostimulation and its effect on pain and paresthesia for a model of acute peripheral ischemia in young college students.

Pain …


A Comprehensive Review Of The Food And Drug Administration, The 510(K) Application Process, And Fda Certification For A Diagnostic Device, Taylor Davis Jun 2015

A Comprehensive Review Of The Food And Drug Administration, The 510(K) Application Process, And Fda Certification For A Diagnostic Device, Taylor Davis

Biomedical Engineering

The company G-Force CRC LLC is currently experiencing the dichotomy of the FDA's conflicting role right now as they begin to approach FDA approval. G-Force CRC LLC is a small medical device company headquartered in San Diego, CA. The owner of the company, Dr. Ian Purcell, is an Otoneurologist apart of Alvarado Hospital. His medical practice mainly deals with patients who have balance disorders and therefore the devices that he has developed over the last 6+ years are primarily used to assist in the diagnosis of those balance disorders. G-Force CRC LLC was officially created in the summer of 2013 …


Self-Contained Breathing Apparatus For Firefighter With A Permanent Stoma, Jason Delgadillo, Aaron Wheeler, Zachary Wishbow Jun 2015

Self-Contained Breathing Apparatus For Firefighter With A Permanent Stoma, Jason Delgadillo, Aaron Wheeler, Zachary Wishbow

Biomedical Engineering

The purpose of this project was to create a unique SCBA (self-contained breathing apparatus) for a firefighter named Chris Gauer. This prototype consists of a SCBA headgear connected to a polycarbonate-formed stoma mask with a medical-grade sanitary silicone hose.


Development, Characterization, And Optimization Of Process For Minimal Functional Barrier And Channel Width In Nitrocellulose Paper Microfluidic Diagnostic Platforms, Ryan Daniel Silva Sep 2014

Development, Characterization, And Optimization Of Process For Minimal Functional Barrier And Channel Width In Nitrocellulose Paper Microfluidic Diagnostic Platforms, Ryan Daniel Silva

Biomedical Engineering

A central goal of diagnostic microfluidics is to reduce the cost of diagnostic medicine by reducing the equipment and reagents needed to perform diagnostic tests. The literature has demonstrated that a wax printer can be used to pattern nitrocellulose paper with hydrophobic barriers to direct a sample in a defined reaction path, eliminating the need for external pumps and controllers. However, manufacturing methods for minimizing sample volume (and thus reagent volume) in a paper-diagnostic chip have not been well defined. In this work, we experimentally determine manufacturing processes for creating functional features of minimal size—effectively reducing the sample size and …


Sonar For The Visually Impaired, Anastasia Newark, Edwin Ng, Scott Terhorst Jun 2014

Sonar For The Visually Impaired, Anastasia Newark, Edwin Ng, Scott Terhorst

Biomedical Engineering

There are currently no inexpensive assistive devices that allow the visually impaired detect low hanging objects that are above waist height and may cause injury, such as a rope or tree branch. The challenge presented to the team by the Quality of Life Plus Lab (QL+) was to develop a Sonar Cane device that attaches to a traditional white cane to address this problem. This device must be lightweight, inexpensive to manufacture, have a long battery life, and accurately detect obstacles to prevent user injury.


Analysis Of Acetabular Cup Orientation Effects On Stress Shielding In Total Hip Replacements Using Finite Element Methods, Brogan Mcguire, Jennifer Gemkow, Brad Gausewitz, Alex Georges Jun 2013

Analysis Of Acetabular Cup Orientation Effects On Stress Shielding In Total Hip Replacements Using Finite Element Methods, Brogan Mcguire, Jennifer Gemkow, Brad Gausewitz, Alex Georges

Biomedical Engineering

Improper positioning of the acetabular cup has been shown to contribute to issues such as high wear rates and dislocations in total hip replacements. The differences in contact mechanics due to varying orientation of the acetabular cup may also significantly affect strain distribution in the femur. This study examined these effects of acetabular orientation changes and their contribution to stress shielding using finite element analysis. A solid model of a cementless total hip implant was obtained using 3D point scanning and implanted virtually into a femur solid model. The implanted femur model was imported into ABAQUS and loaded with a …


A Mouse Model Of Aortic Endothelial Denudation And Neointimal Formation, Ashkon C. Nehzati Jun 2013

A Mouse Model Of Aortic Endothelial Denudation And Neointimal Formation, Ashkon C. Nehzati

Biomedical Engineering

More than 385,000 people die from coronary heart disease (CHD) annually and treatment costs $108.9 billion each year including the cost of health care services, medications, and lost productivity. CHD decreases heart function by limiting oxygen and nutrient transport carried through the coronary arteries. A complete block to the coronary arteries causes a myocardial infarction in response to an elimination of blood supply to cardiomyocytes. Partial occlusion results in insufficient blood supply to cardiomyocytes, producing myocardial ischemia and angina, which are usually treated with intravascular stents deployed percutaneously, before myocardial infarction occurs. Stents are the most common ways to expand …


A Microfluidic Pretreatment Isoelectric Focusing Dc-Field Assisted H-Filter For The Separation Of Charged Particles, Cameron Sean Carroll Mar 2013

A Microfluidic Pretreatment Isoelectric Focusing Dc-Field Assisted H-Filter For The Separation Of Charged Particles, Cameron Sean Carroll

Biomedical Engineering

Microfluidic devices are small portable diagnostic chips that allow for analysis of a biologic sample at relatively low cost. This makes them ideal for settings where a hospital is unavailable. The microfluidic pretreatment isoelectric focusing DC-field assisted H-filter is a device that allows for the separation of differently charged particles in a biologic sample. It does this by employing the concepts of diffusion, electrophoresis, and isoelectric focusing. This is perfect for isolation of a desired analyte or separation of waste from a sample in order to achieve better diagnostic results. The device was first modeled mathematically and visually using Comsol. …


Testing And Validation Of An Autostainer, Nicholas Hanne Jun 2012

Testing And Validation Of An Autostainer, Nicholas Hanne

Biomedical Engineering

Histology performed by Cal Poly students for research projects and labs are currently performed by hand using a dipping technique. This technique is time consuming, expensive, imprecise, and often unrepeatable. Central Coast Pathology donated a Dako Autostainer to the Biomedical Engineering Department that can perform immunohistological stains of up to 48 samples simultaneously using tightly controlled reagent volumes and incubation times. Protocols are programmed into the machine and can be repeated under the same conditions every time with minimal preparation and exposure to potentially dangerous reagents. The autostainer was repaired and validated by comparing PECAM & BBI stains performed on …


An Inexpensive Method For Creating Paste To Be Used In Paper-Based Microfluidic Devices, Kirra Marie Sankey Jun 2011

An Inexpensive Method For Creating Paste To Be Used In Paper-Based Microfluidic Devices, Kirra Marie Sankey

Biomedical Engineering

Microfluidic devices are diagnostic tools that are small, portable, and inexpensive. This makes them ideally suited for resource-limited settings. To construct a 3D device, each layer of patterned paper is stacked using double-sided tape with holes corresponding to the pattern. It is necessary to have a paste to fill the holes in the tape and provide a medium for the fluid to wick through. The powder used to make the paste is very expensive and must be bought in bulk (an estimated $1121 - $1231), so it is not convenient for the Biomedical (BMED) department to use. This project was …