Open Access. Powered by Scholars. Published by Universities.®
Biomedical Devices and Instrumentation Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- California Polytechnic State University, San Luis Obispo (17)
- University of Arkansas, Fayetteville (14)
- University of Nebraska - Lincoln (14)
- The University of Akron (13)
- Old Dominion University (11)
-
- University of Nevada, Las Vegas (10)
- Purdue University (9)
- University of Kentucky (8)
- Virginia Commonwealth University (8)
- Dartmouth College (7)
- University of Mississippi (7)
- Marquette University (5)
- University of Denver (5)
- University of New Mexico (5)
- Brigham Young University (4)
- City University of New York (CUNY) (4)
- Clemson University (4)
- University of Louisville (4)
- University of South Alabama (4)
- Wayne State University (4)
- West Virginia University (4)
- Embry-Riddle Aeronautical University (3)
- Loma Linda University (3)
- Louisiana State University (3)
- Technological University Dublin (3)
- The Texas Medical Center Library (3)
- University of Connecticut (3)
- University of Malaya (3)
- University of North Florida (3)
- Children's Health Medical Center Dallas (2)
- Keyword
-
- Biomedical engineering (9)
- Machine learning (6)
- Biomedical Engineering (5)
- Microfluidics (5)
- Biomechanics (4)
-
- Daniel Felix Ritchie School of Engineering and Computer Science (4)
- Gait (4)
- Hydrogel (4)
- Motor control (4)
- Prosthetics (4)
- 3D printing (3)
- Angiogenesis (3)
- Arduino (3)
- Arthroplasty (3)
- Cardiovascular disease (3)
- Cochlear implant (3)
- Electro-larynx (3)
- Endothelial Dysfunction (3)
- Engineering (3)
- Ergonomics (3)
- Heart failure (3)
- Intelligibility (3)
- Laryngectomy (3)
- Neuromodulation (3)
- Parkinson's Disease (3)
- Radiotherapy (3)
- Sensors (3)
- Simulation (3)
- Wearable technology (3)
- 3D-Printing (2)
- Publication Year
- Publication
-
- Williams Honors College, Honors Research Projects (13)
- Electronic Theses and Dissertations (10)
- Master's Theses (10)
- UNLV Theses, Dissertations, Professional Papers, and Capstones (9)
- Honors Theses (8)
-
- The Summer Undergraduate Research Fellowship (SURF) Symposium (7)
- Biomedical Engineering (6)
- Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research (6)
- Graduate Theses and Dissertations (6)
- Theses and Dissertations (6)
- Theses and Dissertations--Biomedical Engineering (5)
- Graduate Theses, Dissertations, and Problem Reports (ETD) (4)
- All Theses (3)
- Biomedical Engineering ETDs (3)
- Biomedical Engineering Undergraduate Honors Theses (3)
- Biomedical Engineering Western Regional Conference (3)
- Conference Papers (3)
- Dartmouth College Master’s Theses (3)
- Loma Linda University Electronic Theses, Dissertations & Projects (3)
- Master's Theses (2009 -) (3)
- Mechanical & Aerospace Engineering Faculty Publications (3)
- Student Works (2020-2029) (3)
- 2026 (2)
- Annual Research Symposium (2)
- Bioelectrics Publications (2)
- Biology and Medicine Through Mathematics Conference (2)
- Center for Bioelectronics Publications (2)
- Dartmouth College Ph.D Dissertations (2)
- Department of Mechanical and Materials Engineering: Faculty Publications (2)
- Discovery Day - Daytona Beach (2)
- Publication Type
- File Type
Articles 211 - 236 of 236
Full-Text Articles in Biomedical Devices and Instrumentation
Development Of A Multi-Purpose Automated Synthesis Module For Production Of Novel Pet Radiopharmaceuticals, I Hong Shih
Development Of A Multi-Purpose Automated Synthesis Module For Production Of Novel Pet Radiopharmaceuticals, I Hong Shih
Dissertations and Theses (Open Access)
Among radiopharmaceuticals of positron emission tomography (PET), 18F-Fluorodeoxyglucose (18F-FDG) made from commercialized automated synthesis module is the most frequently used in tumor diagnoses. But the false positive findings, such as infectious tissues and post-operative surgical conditions, show strong uptake of 18F-FDG in PET scans which requires extra clinical procedures to confirm the results. Moreover, the false negative findings, such as low glycolytic activity tumors, reduce the accuracy of PET scans. Therefore, there will be new PET radiopharmaceuticals to redeem the defects of 18FDG-PET applications.
Current commercialized automated synthesis modules are suitable for clinical use, but …
Utilizing Fast Spin Echo Mri To Reduce Image Artifacts And Improve Implant/Tissue Interface Detection In Refractory Parkinson’S Patients With Deep Brain Stimulators, Subhendra N. Sarkar, Pooja R. Sarkar, Efstathios Papavassiliou, Rafael Rojas
Utilizing Fast Spin Echo Mri To Reduce Image Artifacts And Improve Implant/Tissue Interface Detection In Refractory Parkinson’S Patients With Deep Brain Stimulators, Subhendra N. Sarkar, Pooja R. Sarkar, Efstathios Papavassiliou, Rafael Rojas
Publications and Research
Introduction. In medically refractory Parkinson’s disease (PD) deep-brain stimulation (DBS) is an effective therapeutic tool. Postimplantation MRI is important in assessing tissue damage and DBS lead placement accuracy. We wanted to identify which MRI sequence can detectDBS leads with smallest artifactual signal void, allowing better tissue/electrode edge conspicuity.
Methods. Using an IRB approved protocol 8 advanced PDpatientswere imagedwithinMRconditional safety guidelines at lowRF power (SAR ≤ 0.1 W/kg) in coronal plane at 1.5T by various sequences.The image slices were subjectively evaluated for diagnostic quality and the lead contact diameters were compared to identify a sequence least affected by metallic leads.
Results …
Head Impact Exposure In Male And Female Collegiate Ice Hockey Players, Bethany J. Wilcox, Jonathan G. Beckwith, Richard M. Greenwald, Jeffrey J. Chu, Thomas W. Mcallister, Laura A. Flashman, Arthur C. Maerlender, Ann-Christine Duhaime, Joseph J. Crisco
Head Impact Exposure In Male And Female Collegiate Ice Hockey Players, Bethany J. Wilcox, Jonathan G. Beckwith, Richard M. Greenwald, Jeffrey J. Chu, Thomas W. Mcallister, Laura A. Flashman, Arthur C. Maerlender, Ann-Christine Duhaime, Joseph J. Crisco
Department of Psychology: Faculty Publications
The purpose of this study was to quantify head impact exposure (frequency, location and magnitude of head impacts) for individual male and female collegiate ice hockey players and to investigate differences in exposure by sex, player position, session type, and team. Ninety-nine (41 male, 58 female) players were enrolled and 37,411 impacts were recorded over three seasons. Frequency of impacts varied significantly by sex (males: 287 per season, females: 170, p < 0.001) and helmet impact location (p < 0.001) but not by player position (p = 0.088). Head impact frequency also varied by session type; both male and female players sustained more impacts in games than in practices (p < 0.001), however the magnitude of impacts did not differ between session types. There was no difference in 95th percentile peak linear acceleration between sexes (males: 41.6 g, females: 40.8 g), but 95th percentile peak rotational acceleration and HITsp (a composite severity measure) were greater for males than females (4424, 3409 rad/s2, and 25.6, 22.3, respectively). Impacts to the back of the helmet resulted in the greatest 95th percentile peak linear accelerations for males (45.2 g) and females (50.4 g), while impacts to the side and back of the head were associated with the greatest 95th percentile peak rotational accelerations (males: 4719, 4256 rad/sec2, females: 3567, 3784 rad/sec2, respectively). It has been proposed that reducing an individual’s head impact exposure is a practical approach for reducing the risk of …
Formulation Development Of A Polymer-Drug Matrix With A Controlled Release Profile For The Treatment Of Glaucoma, Eric W. Tsoi
Formulation Development Of A Polymer-Drug Matrix With A Controlled Release Profile For The Treatment Of Glaucoma, Eric W. Tsoi
Master's Theses
Glaucoma is the leading cause of blindness in the United States accounting for 9-12% of all cases of blindness. Currently, the front line treatment for glaucoma are prostaglandins that may have to be taken up to several times a day. Even with proper treatment, roughly 11% of the patients using the treatment are non-compliant and lose their vision. In this project, ForSight Laboratories has developed a pharmaceutical drug delivering implant with the capability of sustaining long-term release of a prostaglandin as a new way to treat the condition. This project reports the product development of a polymer drug matrix with …
Closed Loop Control Of A Cylindrical Tube Type Ionic Polymer Metal Composite (Ipmc), Benjamin Mead
Closed Loop Control Of A Cylindrical Tube Type Ionic Polymer Metal Composite (Ipmc), Benjamin Mead
UNLV Theses, Dissertations, Professional Papers, and Capstones
The goal of this research is to provide a framework for the integration of tube type, cylindrical Ionic Polymer Metal-Composite (IPMC) into conventional devices. IPMCs are one of the most widely used types of electro-active polymer actuator, due to their low electric driving potential and large deformation range. For this research a tube type IPMC was investigated. This IPMC has a circular cross section with four separate electrodes on its surface and a hole through the middle. The four electrodes allow for biaxial bending and accurate control of the tip location. One of the main advantages of using this type …
Design And Implementation Of Wireless Point-Of-Care Health Monitoring Systems: Diagnosis For Sleep Disorders And Cardiovascular Diseases, Se Chang Oh
Graduate Theses and Dissertations
Chronic sleep disorders are present in 40 million people in the United States. More than 25 million people remain undiagnosed and untreated, which accounts for over $22 billion in unnecessary healthcare costs. In addition, another major chronic disease is the heart diseases which cause 23.8% of the deaths in the United States. Thus, there is a need for a low cost, reliable, and ubiquitous patient monitoring system. A remote point-of-care system can satisfy this need by providing real time monitoring of the patient's health condition at remote places. However, the currently available POC systems have some drawbacks; the fixed number …
Design And Testing Of Novel Mouthguard With Intermediate Nitinol And Foam Layers, Adam Kessler
Design And Testing Of Novel Mouthguard With Intermediate Nitinol And Foam Layers, Adam Kessler
UNLV Theses, Dissertations, Professional Papers, and Capstones
It is the aim of this study to investigate a novel mouthguard design that incorporates the use of a nickel-titanium (Nitinol) layer and thin foam layer in addition to EVA layers. It is thought that the Nitinol layer can distribute the force of an impact and that the thin foam layer may absorb this distributed force better than a solid EVA mouthguard of the same thickness. Rectangular, flat coupons representative of several mouthguard configurations were constructed for testing using an instrumented drop-weight impact tower. The coupon configurations include a control made of laminated EVA, a group of laminated EVA and …
Automated Point-Of-Care Image Processing Methodology For The Diagnosis Of Malaria, Michael B. Jorgensen
Automated Point-Of-Care Image Processing Methodology For The Diagnosis Of Malaria, Michael B. Jorgensen
Master's Theses
Malaria has profoundly influenced human history for over four thousand years and despite numerous attempts at eradication, the prevention, diagnosis, and treatment of malaria have been largely ineffective. More than five hundred million people are affected by malaria every year resulting in over one million deaths. Drug resistance development by the parasite has diminished the effectiveness of numerous treatment options due, in part, to overtreatment of negative patients based on insufficient clinical algorithms and diagnostic methods. The goal of this research was to develop an image analysis algorithm to diagnose malaria with a high degree of sensitivity and specificity in …
Modeling Hrtf For Sound Localization In Normal Listeners And Bilateral Cochlear Implant Users, Douglas A. Miller
Modeling Hrtf For Sound Localization In Normal Listeners And Bilateral Cochlear Implant Users, Douglas A. Miller
Electronic Theses and Dissertations
Mathematical models can be very useful for understanding complicated systems and for testing algorithms through simulation that would be difficult or expensive to implement. This dissertation presents a model that attempts to simulate the sound localization performance of persons using bilateral cochlear implants. The expectation is that this model could prove to be a useful tool in developing new signal processing algorithms for neural encoding strategies.
The head related transfer function (HRTF) is a critical component of this model, and in the ideal case, provides the base characteristics of head shadow, torso and pinna effects. This defines the temporal, intensity …
On The Importance Of Modeling Stent Procedure For Predicting Arterial Mechanics, Shijia Zhao, Linxia Gu, Stacey R. Froemming
On The Importance Of Modeling Stent Procedure For Predicting Arterial Mechanics, Shijia Zhao, Linxia Gu, Stacey R. Froemming
Department of Mechanical and Materials Engineering: Faculty Publications
The stent-artery interactions have been increasingly studied using the finite element method for better understanding of the biomechanical environment changes on the artery and its implications. However, the deployment of balloon-expandable stents was generally simplified without considering the balloon-stent interactions, the initial crimping process of the stent, its overexpansion routinely used in the clinical practice, or its recoil process. In this work, the stenting procedure was mimicked by incorporating all the above-mentioned simplifications. The impact of various simplifications on the stent-induced arterial stresses was systematically investigated. The plastic strain history of stent and its resulted geometrical variations, as well as …
Improving Health Care Quality And Safety: The Development And Assessment Of Laparoscopic Surgery Instrumentation, Practices And Procedures, Bernadette Mccrory
Improving Health Care Quality And Safety: The Development And Assessment Of Laparoscopic Surgery Instrumentation, Practices And Procedures, Bernadette Mccrory
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Adverse events due to medical errors are a leading cause of death in the United States exceeding the mortality rates of motor vehicle accidents, breast cancer and AIDS. Improvements can and should be made to reduce the rates of preventable surgical errors since they account for nearly half of all adverse events within hospitals. Although minimally invasive surgery has proven patient benefits such as reduced postoperative pain and hospital stay, its operative environment imposes substantial physical and cognitive strain on the surgeon increasing the risk of error. In order to mitigate errors and protect patients, a multidisciplinary approach was taken …
The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink
The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink
UNLV Theses, Dissertations, Professional Papers, and Capstones
Two areas of research interest in the design and use of lower limb prosthetic devices are how foot performance varies with design and how prosthesis alignment affects gait. The current study addressed both of these areas through the use of the JR3 triaxial transducer mounted at the base of the socket. The transducer is an innovative form of instrumentation that measures forces and moments at the end of the socket. Traditional measurement of gait uses a force plate buried in the floor of a gait laboratory. The study established that the transducer offers a viable means of instrumentation for amputee …
Safety, Ergonomics And Human Factors Engineering On Biomedical Devices Design, Alejandra Sandoval Vazquez^, Noe Vargas Hernandez*
Safety, Ergonomics And Human Factors Engineering On Biomedical Devices Design, Alejandra Sandoval Vazquez^, Noe Vargas Hernandez*
COURI Symposium Abstracts, Spring 2012
No abstract provided.
Artificial Devices As A Viable Alternative To The Conventional Heart Transplant, Hadassah Radzik
Artificial Devices As A Viable Alternative To The Conventional Heart Transplant, Hadassah Radzik
The Science Journal of the Lander College of Arts and Sciences
The human heart is one of the most vital organs in the body. It distributes blood throughout the body, providing the body with oxygen and nutrition, and contributes to metabolism. When the heart fails, blood flow is impaired, thereby limiting the exchange of oxygen within the cardiopulmonary system as well as diminishing oxygenation and nutrition to the other major organs and periphery. The only current proven treatment for advanced heart failure is cardiac transplant. Given the heart’s importance and the scarcity of donated organs, modern medicine has experimented with the creation of an artificial heart. Because the heart is primarily …
A Thousand Tiny Pieces: The Federal Circuit’S Fractured Myriad Ruling, Lessons To Be Learned, And The Way Forward, Jonathan R. K. Stroud
A Thousand Tiny Pieces: The Federal Circuit’S Fractured Myriad Ruling, Lessons To Be Learned, And The Way Forward, Jonathan R. K. Stroud
IP Theory
No abstract provided.
Cyberknife Radiation Modeling: Effects Of Relaxed Translational And Rotational Constraints On Healthy Tissue Irradiation, Sudha Bhavaroop Potineni
Cyberknife Radiation Modeling: Effects Of Relaxed Translational And Rotational Constraints On Healthy Tissue Irradiation, Sudha Bhavaroop Potineni
Electrical & Computer Engineering Theses & Dissertations
The Cyberknife system is a robotic radio surgery instrument that is used to treat cancers in different parts of the human body. Because of its accuracy and precision, it has become one of the best radio surgery systems in the world. However, even with Cyberknife the treatment time for one session takes from 30 minutes up to 120 minutes depending on the size, shape, and position of the tumor in the human body. In this research, a solution is presented to aid in reducing this long treatment time. An algorithm is developed which simulates the amount of the healthy tissue …
Laser Etched Pmma Microfluidic Chip Design And Manufacture With Applications In Capillary Zone Electrophoresis, Evan Allen Barbre
Laser Etched Pmma Microfluidic Chip Design And Manufacture With Applications In Capillary Zone Electrophoresis, Evan Allen Barbre
Master's Theses
This thesis encompasses a feasibility study of using low-cost materials to manufacture microfluidic chips that can perform the same functions as chips manufactured using traditional methods within an acceptable range of efficiency of chips created with more exotic methods and materials. The major parts of the project are the selection and characterization of the fabrication methods for creating the channels for fluid flow, the methods for sealing the channels to create a usable chip and the electrophoretic separations of carboxylated microspheres of different potentials. In this work we seek to answer the question if laser-etched PMMA microfluidic chips are comparable …
Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Conference Papers
During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, the intelligibility of speech produced using a novel hands-free actuator is compared to speech produced using a conventional electrolarynx. Two able-bodied speakers (one male, one female) performed a closed response test containing 28 monosyllabic words, once using a conventional electrolarynx and a second time using the novel design. The resulting audio recordings …
Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle
Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle
Conference Papers
During voiced speech, the larynx acts as the sound source, providing a quasi-periodic excitation of the vocal tract. Following a total laryngectomy, some people speak using an electrolarynx which employs an electromechanical actuator to perform the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the monotonic sound emitted, the need for a free-hand to operate the device, and the difficulty experienced by many laryngectomees in adapting to its use. One improvement to the electrolarynx, which clinicians and users frequently suggest, is the provision of a convenient hands-free control facility. This would allow more natural use of …
Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle
Conference Papers
During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. Following a laryngectomy, some people speak using an electrolarynx which replaces the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the buzzing monotonic sound emitted, the need for a free hand to operate the device, and difficulty experienced by many laryngectomees in adapting to its use. Despite these shortcomings, it remains the preferred method of speech rehabilitation for a substantial minority of laryngectomees. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal …
Effects Of Reamer-Femoral Component Offset On Cement Mantle Penetration In Hip Resurfacing Arthroplasty, Mark Lloyd Paulick
Effects Of Reamer-Femoral Component Offset On Cement Mantle Penetration In Hip Resurfacing Arthroplasty, Mark Lloyd Paulick
Master's Theses
Hip resurfacing arthroplasty has changed the treatment of end stage arthritis without severe deformity for young, active adults. Presently, there are varying clinical approaches to implant design selection and cementation techniques. The purpose of this project is to determine what amount of reamer-femoral component offset allows for the best cement penetration into the femoral head.
Rapid prototyped femoral component models were produced with reamer femoral component offsets of 0.0 mm, 0.5 mm, and 1.0 mm. After implantation onto models of reamed femoral heads made from high-density open-cell reticulated carbon foam, cement penetration was assessed from cross-sections of the foam-implant unit. …
Ekg Tracking For Augmented Standardized Patient Virtual Pathology Stethoscope Heart Auscultation, Sujith Surendran
Ekg Tracking For Augmented Standardized Patient Virtual Pathology Stethoscope Heart Auscultation, Sujith Surendran
Electrical & Computer Engineering Theses & Dissertations
In recent years, a lot of research has focused on improving the clinical skills of medical students and medical practitioners using standardized patients. Standardized patients (SP's) are used by the medical students and physicians in place of mannequins for a more realistic experience. SP's are real people trained to simulate specific illnesses and conditions to a high degree of accuracy which makes it difficult for the medical students to distinguish them from real patients. This research will enhance the capabilities of the standardized patients by providing a non-invasive, natural, harmless and realistic appearing tracking method for placing virtual pathologies using …
A Model For Electrical Communication Between Cochlear Implants And The Brain, Douglas A. Miller
A Model For Electrical Communication Between Cochlear Implants And The Brain, Douglas A. Miller
Electronic Theses and Dissertations
In the last thirty years, cochlear implants have become an invaluable instrument in the treatment of severe-to-profound hearing impairment. An important aspect of research in the continued development of cochlear implants is the in vivo assessment of signal processing algorithms intended to improve perception of speech and other auditory signals. In trying to determine how closely cochlear implant recipients process sound relative to the processing done by a normal auditory system, various assessment techniques have been applied. The most common technique has been measurement of auditory evoked potentials (AEPs), which involves the recording of neural responses to auditory stimulation. Depending …
Laser And Led Effects On The Proliferation Rate Of Periodontal Ligament Fibroblasts, Allen J. Job
Laser And Led Effects On The Proliferation Rate Of Periodontal Ligament Fibroblasts, Allen J. Job
Loma Linda University Electronic Theses, Dissertations & Projects
PURPOSE: To compare the effectiveness of a Gallium Aluminum Arsenide (GaAlAs) diode laser and a light emitting diode (LED) on periodontal ligament fibroblast cell proliferative rates.
METHODS and MATERIALS: PDLF obtained from freshly extracted permanent teeth were cultured under standard conditions until a subconfluent monolayer was present. The next section took 5 days to complete. On day 1, the initial cell concentration of 700 uL/cm2 was plated on 96-well assay plates and placed in a CO2 incubator at 37° C for 24 hours. On day 2, cell counts were first verified using hemocytometry then were irradiated using an …
New In Vivo And In Vitro Techniques For Quantification Of Lateral Force Levels That Cause Implants To Fail : A Progress Report On Monkey Research, V. Leroy Leggitt
New In Vivo And In Vitro Techniques For Quantification Of Lateral Force Levels That Cause Implants To Fail : A Progress Report On Monkey Research, V. Leroy Leggitt
Loma Linda University Electronic Theses, Dissertations & Projects
Two new techniques for quantification of forces generated by an expansion screw apparatus placed between pairs of cylindrical endosseous titanium implants are described, along with preliminary data gained from their use in Macaca rhesus monkeys. Strain gages were bonded to the expansion apparatus and were calibrated either directly by micro load cell, or indirectly by Instron Machine to reflect the applied force.
Immediate loads of up to 6 kilograms have been applied to the implants with no increase in mobility as verified by a Periotest device. No previous studies on the orthodontic uses of implants have evaluated in vivo forces …
A Procedure For The Measurement Of Glosso-Maxillary Forces, Howard L. Lilly Jr.
A Procedure For The Measurement Of Glosso-Maxillary Forces, Howard L. Lilly Jr.
Loma Linda University Electronic Theses, Dissertations & Projects
The purpose of this investigation was to develop a clinically feasible procedure for recording the magnitudes of glosso-maxillary forces at four palatal loci using an electronic transducer system described by Lear et, al. (1965). Of particular interest was the development of a convenient and accurate calibration device for both intraoral and extraoral application. A further object of interest was the effect an acrylic carrier plate might introduce to the magnitude of force response. Finally whether or not any significant adaptation to the carrier plate or to the transducers occurs during a reasonable testing period (six to seven hours).
A calibration …