Open Access. Powered by Scholars. Published by Universities.®
Biomedical Devices and Instrumentation Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- California Polytechnic State University, San Luis Obispo (17)
- University of Arkansas, Fayetteville (14)
- University of Nebraska - Lincoln (14)
- The University of Akron (13)
- Old Dominion University (11)
-
- University of Nevada, Las Vegas (10)
- Purdue University (9)
- University of Kentucky (8)
- Virginia Commonwealth University (8)
- Dartmouth College (7)
- University of Mississippi (7)
- Marquette University (5)
- University of Denver (5)
- University of New Mexico (5)
- Brigham Young University (4)
- City University of New York (CUNY) (4)
- Clemson University (4)
- University of Louisville (4)
- University of South Alabama (4)
- Wayne State University (4)
- West Virginia University (4)
- Embry-Riddle Aeronautical University (3)
- Loma Linda University (3)
- Louisiana State University (3)
- Technological University Dublin (3)
- The Texas Medical Center Library (3)
- University of Connecticut (3)
- University of Malaya (3)
- University of North Florida (3)
- Children's Health Medical Center Dallas (2)
- Keyword
-
- Biomedical engineering (9)
- Machine learning (6)
- Biomedical Engineering (5)
- Microfluidics (5)
- Biomechanics (4)
-
- Daniel Felix Ritchie School of Engineering and Computer Science (4)
- Gait (4)
- Hydrogel (4)
- Motor control (4)
- Prosthetics (4)
- 3D printing (3)
- Angiogenesis (3)
- Arduino (3)
- Arthroplasty (3)
- Cardiovascular disease (3)
- Cochlear implant (3)
- Electro-larynx (3)
- Endothelial Dysfunction (3)
- Engineering (3)
- Ergonomics (3)
- Heart failure (3)
- Intelligibility (3)
- Laryngectomy (3)
- Neuromodulation (3)
- Parkinson's Disease (3)
- Radiotherapy (3)
- Sensors (3)
- Simulation (3)
- Wearable technology (3)
- 3D-Printing (2)
- Publication Year
- Publication
-
- Williams Honors College, Honors Research Projects (13)
- Electronic Theses and Dissertations (10)
- Master's Theses (10)
- UNLV Theses, Dissertations, Professional Papers, and Capstones (9)
- Honors Theses (8)
-
- The Summer Undergraduate Research Fellowship (SURF) Symposium (7)
- Biomedical Engineering (6)
- Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research (6)
- Graduate Theses and Dissertations (6)
- Theses and Dissertations (6)
- Theses and Dissertations--Biomedical Engineering (5)
- Graduate Theses, Dissertations, and Problem Reports (ETD) (4)
- All Theses (3)
- Biomedical Engineering ETDs (3)
- Biomedical Engineering Undergraduate Honors Theses (3)
- Biomedical Engineering Western Regional Conference (3)
- Conference Papers (3)
- Dartmouth College Master’s Theses (3)
- Loma Linda University Electronic Theses, Dissertations & Projects (3)
- Master's Theses (2009 -) (3)
- Mechanical & Aerospace Engineering Faculty Publications (3)
- Student Works (2020-2029) (3)
- 2026 (2)
- Annual Research Symposium (2)
- Bioelectrics Publications (2)
- Biology and Medicine Through Mathematics Conference (2)
- Center for Bioelectronics Publications (2)
- Dartmouth College Ph.D Dissertations (2)
- Department of Mechanical and Materials Engineering: Faculty Publications (2)
- Discovery Day - Daytona Beach (2)
- Publication Type
- File Type
Articles 181 - 210 of 236
Full-Text Articles in Biomedical Devices and Instrumentation
Characterization Of Left-Ventricular Thrombus Formation Using High Frequency Ultrasound, Kelsey A. Bullens, Arvin H. Soepriatna, Pavlos P. Vlachos, Craig J. Goergen
Characterization Of Left-Ventricular Thrombus Formation Using High Frequency Ultrasound, Kelsey A. Bullens, Arvin H. Soepriatna, Pavlos P. Vlachos, Craig J. Goergen
The Summer Undergraduate Research Fellowship (SURF) Symposium
Heart failure is a leading cause of death in the United States, and cardiac thrombus, a common morbidity associated with heart failure, significantly increases a patient’s risk of embolic events. The objective of this project is to characterize left-ventricular (LV) thrombus development using high frequency ultrasound imaging in a murine model. C57BL/6J wild-type mice (n=6) were injected intraperitoneally with iron dextran five times a week for six weeks to increase oxidative stress in the heart. Granulocyte-colony stimulating factor (G-CSF) was subcutaneously injected daily during the second week to initiate stem cell migration and stimulate endothelial cell activation, thus increasing the …
Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee
Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee
The Summer Undergraduate Research Fellowship (SURF) Symposium
Hydrocephalus is a neurological disorder that typically requires a long-term implantation of a shunt system to manage its symptoms. These shunt systems are notorious for their extremely high failure rate. More than 40% of all implanted shunt systems fail within the first year of implantation. On average, 85% of all hydrocephalus patients with shunt systems undergo at least two shunt-revision surgeries within 10 years of implantation. A large portion of this high failure rate can be attributed to biofouling-related obstructions and infections. Previously, we developed flexible polyimide-based magnetic microactuators to remove obstructions formed on hydrocephalus shunts. To test the long-term …
Diffusion Modeling And Device Development For Peritoneal Membrane Oxygenation, Liana Hatoum
Diffusion Modeling And Device Development For Peritoneal Membrane Oxygenation, Liana Hatoum
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Acute respiratory distress syndrome (ARDS) is a pulmonary disease that causes hypoxemia and respiratory failure. The mortality rate for ARDS ranges between 27% and 45%. Current treatments including mechanical ventilation and extracorporeal membrane oxygenation (ECMO) are often associated with high risk complications including barotrauma, infection, thrombosis, and hemorrhage. Alternative pulmonary support techniques are needed to improve the survival rate of patients suffering from ARDS. Previous studies introducing pure O2 gas, perfluorocarbons and red blood cells into the intraperitoneal (IP) cavity have reported no effect or only a mild increase in oxygenation. Here we report peritoneal membrane oxygenation (PMO) using …
Design Of Medical Devices For Diagnostics In The Gastrointestinal System, Charles R. Welch
Design Of Medical Devices For Diagnostics In The Gastrointestinal System, Charles R. Welch
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
This thesis presents the design, controls, and testing of two systems: a novel colonoscope locomotion design for diagnostics, and a biosensor capsule that implants a sensor in the small intestine. Each system requires special design considerations for use in the gastrointestinal system.
Colonoscopy procedures are recommended as a screening for colon cancer and related conditions after the age of 50. The need for an improved colonoscope that reduces the colonoscopy time and patient discomfort is apparent. The semi-autonomous device presented here could likely reduce the colonoscopy procedure time by allowing the physician to focus more on the diagnosis and less …
Under The Needle: Ergonomic Issues With Lethal Injection Protocols, Gabriella Hancock
Under The Needle: Ergonomic Issues With Lethal Injection Protocols, Gabriella Hancock
Human Factors and Applied Psychology Student Conference
The institution of capital punishment represents one of the most contentious issues affecting societies today; and while the practice is only implemented in 58 countries, the controversy affects the world at large as over 60% of the human population lives in nations that condone the death penalty (Hali, 2015). In the United States, people who support capital punishment believe the practice to be an effective crime deterrent for potential criminals and therefore a prospective protective measure for law abiding citizens. Moreover, advocates defend their position by forwarding the argument that executions are ‘humane’; that use of lethal injection ensures that …
A New Technique To Improve The Operation Of Prosthetic Limbs During Muscle Fatigue, H. Albunashee, G. Rasool, K. Iqbal, G. White
A New Technique To Improve The Operation Of Prosthetic Limbs During Muscle Fatigue, H. Albunashee, G. Rasool, K. Iqbal, G. White
Journal of the Arkansas Academy of Science
Prosthetic limbs hold a promise to renew the quality of life for the amputee. Neural commands are decoded via a classifier to generate control signals for the prosthetic devices. In the literature, many challenges and limitations have been identified that affect the prosthesis operation. One such drawback is muscle fatigue which degrades the surface electromyogram (sEMG) signals, and consequently, the performance of the deployed classification algorithm declines from 90% to 50% of average accuracy. We used a new technique using the Linear Discrimination Analysis (LDA) algorithm and the muscle synergy-based task discrimination (MSD) algorithm to improve the classification accuracy. In …
A Microfluidic-Based Tactile Sensor For Palpating Mice Tumor Tissues, Yichao Yang, Garett Johnson, Dean Krusienski, Siqi Guo, Cheng Lin, Zhili Hao
A Microfluidic-Based Tactile Sensor For Palpating Mice Tumor Tissues, Yichao Yang, Garett Johnson, Dean Krusienski, Siqi Guo, Cheng Lin, Zhili Hao
Mechanical & Aerospace Engineering Faculty Publications
In light of the need of tissue palpation for Robotics-assisted Minimally Invasive Surgery (RMIS), this paper presents a microfluidic-based tactile sensor for palpating mice tissues for tumor localization. The core of the sensor is a 3x3 sensing-plate/transducer array built into a single polydimethylsiloxane (PDMS) microstructure, with a transducer spacing of 3.75mmx1.5mm. Mounted on a robot, the sensor is pressed against a tissue region with a pre-defined indentation depth pattern, and consequently the stiffness distribution across the tissue region translates to the deflection distribution of the sensing-plate array and is captured by the transducer array underneath as resistance changes. Thus, the …
Hydroband: The Continuous Hydration Monitoring System, Karina E. Atkinson, Catherine P. Benedict
Hydroband: The Continuous Hydration Monitoring System, Karina E. Atkinson, Catherine P. Benedict
Williams Honors College, Honors Research Projects
Dehydration is defined as a mild, moderate, or extreme loss of water in the body. It can result in fever, muscle cramps, headaches, dizziness, or heat stroke in athletes. Ways to determine hydration levels include analysis of the urine, blood, or sweat, body weight changes, skin elasticity tests, and increases in core temperature. Patent search, research journals, and outside studies in the health and fitness market showed that a convenient and continuous hydration monitoring system was not available. Changes in core body temperature proved to be the quickest way to measure hydration levels. The HydroBand system is geared towards athletes …
The Effect Of Neurostimulation On Ischemic Pain And Methods Of Assessing Pain, Kaylee Keck
The Effect Of Neurostimulation On Ischemic Pain And Methods Of Assessing Pain, Kaylee Keck
Biomedical Engineering
Peripheral arterial disease (PAD) impacts approximately eight million people in the United States [1]. Disease progression leads to chronic ischemic pain, hindering quality of life. Pharmaceuticals are a typical treatment for pain associated with PAD; but as few as 30% of patients have a significant reduction of pain (≥50%) [2].
Neurostimulation is commonly used as a treatment for various diseases and injuries, including Parkinson’s disease and sports-related back and knee injuries [2]. The objective of the study was to explore neurostimulation and its effect on pain and paresthesia for a model of acute peripheral ischemia in young college students.
Pain …
Feasibility Of Using Raman-Based Techniques For Breast Cancer Detection, Sara Mollamohammada
Feasibility Of Using Raman-Based Techniques For Breast Cancer Detection, Sara Mollamohammada
Department of Civil and Environmental Engineering: Dissertations, Theses, and Student Research
Breast cancer is one of the common types of cancer among women all over the world. Early diagnosis is an effective way that improve the treatment process and gives the patients a better chance of survival. Many of the patients infected by breast cancer choose breast conservation surgery (BCS). However, some of those will be subjected to mastectomy, and many will have tumor recurrence as there is no precise technique to show the tumor margins. Raman-based methods are powerful techniques with potential to rapidly differentiate normal from tumor tissues and provides a solution to detect tumor margin. This is because …
Quantification Of Blood Flow Velocity Using Color Sensing, Aditya Deepak Sanghani
Quantification Of Blood Flow Velocity Using Color Sensing, Aditya Deepak Sanghani
Master's Theses
Blood flow velocity is an important parameter that can give information on several pathologies including atherosclerosis, glaucoma, Raynaud’s phenomenon, and ischemic stroke [2,5,6,10]. Present techniques of measuring blood flow velocity involve expensive procedures such as Doppler echocardiography, Doppler ultrasound, and magnetic resonance imaging [11,12]. They cost from $8500-$20000. It is desired to find a low-cost yet equally effective solution for measuring blood flow velocity. This thesis has a goal of creating a proof of concept device for measuring blood flow velocity.
Finger blood flow velocity is investigated in this project. The close proximity to the skin of the finger’s arteries …
Lpcoms: Towards A Low Power Wireless Smart-Shoe System For Gait Analysis In People With Disabilities, Ishmat Zerin
Lpcoms: Towards A Low Power Wireless Smart-Shoe System For Gait Analysis In People With Disabilities, Ishmat Zerin
Master's Theses (2009 -)
Gait analysis using smart sensor technology is an important medical diagnostic process and has many applications in rehabilitation, therapy and exercise training. In this thesis, we present a low power wireless smart-shoe system (LPcomS) to analyze different functional postures and characteristics of gait while walking. We have designed and implemented a smart-shoe with a Bluetooth communication module to unobtrusively collect data using smartphone in any environment. With the design of a shoe insole equipped with four pressure sensors, the foot pressure is been collected, and those data are used to obtain accurate gait pattern of a patient. With our proposed …
Integrating Meal And Exercise Into Personalized Glucoregulation Models: Metabolic Dynamics And Diabetic Athletes, Sofie Schunk
Integrating Meal And Exercise Into Personalized Glucoregulation Models: Metabolic Dynamics And Diabetic Athletes, Sofie Schunk
Master's Theses (2009 -)
Diabetes affects nearly 26 million Americans, according to the American Diabetes Association, with as many as three million Americans who have Type 1 Diabetes (ADA, 2015). Type 1 Diabetes (T1D) is autoimmune and characterized by little to no insulin production whereas Type 2 Diabetes (T2D) concerns insulin resistance and inability to use produced insulin. Factors contributing to current diabetes management and regulation include exercise type, daily movement activities, and distinct tissue compartment metabolism, each challenging to model in a robust and comprehensive manner. Past models are highly limited in regard to exercise and varying glucose fluctuations dependent on type, intensity, …
Implantable Device For Wireless Regulation Of The Bladder Through Pelvic Nerve Stimulation, Kelsey C. Bayer, Chris Quinkert, Pedro Irazoqui
Implantable Device For Wireless Regulation Of The Bladder Through Pelvic Nerve Stimulation, Kelsey C. Bayer, Chris Quinkert, Pedro Irazoqui
The Summer Undergraduate Research Fellowship (SURF) Symposium
Urinary incontinence (UI) is the involuntarily urination that usually effects older people or is the result of an injury. UI affects more than eleven million people and the cost of incontinence management in the United States in 2000 was $19.5 billion. Where conventional physical therapies have failed, pelvic nerve stimulation is a promising form of regulating the bladder long term. Piezoresistive pressure sensors consist of two variable resistance values and two known resistance values that are represented on a daughterboard. This unknown resistance represents the change in pressure. The filling and voiding of the bladder was characterized through acute surgeries. …
A Non-Invasive Method Of Measuring Respiration While Providing Wireless Power For Rodents With Implantable Devices, Jynx O. Boyne, Daniel J. Pederson, Zhi Wang, Pedro Irazoqui Dr.
A Non-Invasive Method Of Measuring Respiration While Providing Wireless Power For Rodents With Implantable Devices, Jynx O. Boyne, Daniel J. Pederson, Zhi Wang, Pedro Irazoqui Dr.
The Summer Undergraduate Research Fellowship (SURF) Symposium
Respiratory measurements can be used as diagnostic and research tools. Spirometry is the gold standard for gaining these measurements, but is difficult to use in rodents as it requires an invasive procedure. Total Body Plethysmograpy (TBP) is a non-invasive way to measure respiration rates that does not cause stress to the rodent. In this system, the subject is encased in a solid, constant volume chamber with measurements determining the subject’s respiration. When using TBP in medical or research settings, challenges occur in powering devices within the TBP chamber as wires and other recording equipment compromise the airtightness of the chamber. …
Quantification Of Analyte Concentration From A Paper-Based Lateral Flow Assay Device Using Reflective Sensors, Megan Z. Chiu, Jacqueline Linnes
Quantification Of Analyte Concentration From A Paper-Based Lateral Flow Assay Device Using Reflective Sensors, Megan Z. Chiu, Jacqueline Linnes
The Summer Undergraduate Research Fellowship (SURF) Symposium
Paper-based point-of-care (POC) diagnostics is a growing field in global health due to the extreme portability, accuracy, affordability, and ease of use of these tests. Advancements in recent years have led to more accurate detection and improved functionality using multistep molecular diagnostics. Many such assays utilize lateral flow detection strips for visualization of diagnostic results by eye, which limits the results to qualitative Yes/No readouts. This project focused on combining recent developments in paper-based POC diagnostics to develop and optimize an in-house built quantitative paper-based diagnostic reader for lateral flow detection in low-resource settings. Initially different sensors, including photocell sensors, …
Design And Development Of Two Component Hydrogel Ejector For Three-Dimensional Cell Growth, Thomas Dunkle, Jessica Deschamps, Connie Dam
Design And Development Of Two Component Hydrogel Ejector For Three-Dimensional Cell Growth, Thomas Dunkle, Jessica Deschamps, Connie Dam
Honors Scholar Theses
Hydrogels are useful in wound healing, drug delivery, and tissue engineering applications, but the available methods of injecting them quickly and noninvasively are limited. The medical industry does not yet have access to an all-purpose device that can quickly synthesize hydrogels of different shapes and sizes. Many synthesis procedures that have been developed result in the formation of amorphous hydrogels. While generally useful, amorphous hydrogels exhibit limited capability in tissue engineering applications, especially due to their viscous properties. This endeavor aims to modulate the appropriate gelation parameters, optimize the injection process, and create a prototype that allows for the extrusion …
Evaluating The Effectiveness Of Cranial Molding For Treatment Of Positional Plagiocephaly Using Finite Element Analysis, Maziyar Keshtgar
Evaluating The Effectiveness Of Cranial Molding For Treatment Of Positional Plagiocephaly Using Finite Element Analysis, Maziyar Keshtgar
Master's Theses
Since the advent of recommendations for placing infants in the supine position during sleep to reduce the incidence of sudden infant death syndrome, clinicians have noted an increase in the frequency of cranial asymmetry due to deformation of suture sections of the infants’ skulls as a result of constant concentrated stress in one area at the back of their head. This specific form of cranial deformation is known as positional plagiocephaly and its rate of occurrence has increased from 0.3% in 8.2% within the past 30 years.
Current treatments and methodologies for preventing and correcting positional plagiocephaly such as stretching …
Noncontact Diffuse Correlation Tomography Of Breast Tumor, Lian He
Noncontact Diffuse Correlation Tomography Of Breast Tumor, Lian He
Theses and Dissertations--Biomedical Engineering
Since aggressive cancers are frequently hypermetabolic with angiogenic vessels, quantification of blood flow (BF) can be vital for cancer diagnosis. Our laboratory has developed a noncontact diffuse correlation tomography (ncDCT) system for 3-D imaging of BF distribution in deep tissues (up to centimeters). The ncDCT system employs two sets of optical lenses to project source and detector fibers respectively onto the tissue surface, and applies finite element framework to model light transportation in complex tissue geometries. This thesis reports our first step to adapt the ncDCT system for 3-D imaging of BF contrasts in human breast tumors. A commercial 3-D …
Diffuse Optical Measurements Of Head And Neck Tumor Hemodynamics For Early Prediction Of Chemo-Radiation Therapy Outcomes, Lixin Dong
Theses and Dissertations--Biomedical Engineering
Chemo-radiation therapy is a principal modality for the treatment of head and neck cancers, and its efficacy depends on the interaction of tumor oxygen with free radicals. In this study, we adopted a novel hybrid diffuse optical instrument combining a commercial frequency-domain tissue oximeter (Imagent) and a custom-made diffuse correlation spectroscopy (DCS) flowmeter, which allowed for simultaneous measurements of tumor blood flow and blood oxygenation. Using this hybrid instrument we continually measured tumor hemodynamic responses to chemo-radiation therapy over the treatment period of 7 weeks. We also explored monitoring dynamic tumor hemodynamic changes during radiation delivery. Blood flow data analysis …
Shotblocker® - Bionix® Senior Design, Samuel Dockery
Shotblocker® - Bionix® Senior Design, Samuel Dockery
Williams Honors College, Honors Research Projects
No abstract provided.
Design And Creation Of A Device To Induce Vergence Eye Movements, Jacob B. Jaminet, Paul A. Wetzel
Design And Creation Of A Device To Induce Vergence Eye Movements, Jacob B. Jaminet, Paul A. Wetzel
Undergraduate Research Posters
Automated eye-tracking systems can detect and analyze eye movements as a means to accurately diagnose more than 20 neurological diseases including mild traumatic brain injury. Mild traumatic brain injury is an occurrence of injury to the head resulting from blunt trauma or from acceleration or deceleration forces. Eye movement refers to the voluntary or involuntary movement of the eyes, helping in acquiring, fixating and tracking visual stimuli. There are three types of voluntary eye movement to track objects: smooth pursuit, vergence shifts and saccades. Vergence shifts are eye movements where the eyes move in opposite directions: moving to the midline …
Peracetic Acid: A Practical Agent For Sterilizing Heat-Labile Polymeric Tissue-Engineering Scaffolds, William R. Trahan
Peracetic Acid: A Practical Agent For Sterilizing Heat-Labile Polymeric Tissue-Engineering Scaffolds, William R. Trahan
Theses and Dissertations
Advanced biomaterials and sophisticated processing technologies aim to fabricate tissue-engineering scaffolds that can predictably interact within a biological environment at a cellular level. Sterilization of such scaffolds is at the core of patient safety and is an important regulatory issue that needs to be addressed prior to clinical translation. In addition, it is crucial that meticulously engineered micro- and nano- structures are preserved after sterilization. Conventional sterilization methods involving heat, steam and radiation are not compatible with engineered polymeric systems because of scaffold degradation and loss of architecture. Using electrospun scaffolds made from polycaprolactone (PCL), a low melting polymer, and …
Development Of A Heart Rate Variability Measurement System Using Embedded Electronics, Naresh Kumar Velmurugan
Development Of A Heart Rate Variability Measurement System Using Embedded Electronics, Naresh Kumar Velmurugan
Graduate Theses and Dissertations
Recent advances in embedded electronics have a remarkable influence on the health care system. One of the most important applications is to monitor the health care of the patients at anytime and anyplace. In the last two decades, many researchers have focused mainly on heart rate variability (HRV) measurements. Patient's heart rate variability should be continuously monitored to help them in case of emergency. Under these circumstances, patients are required to have a HRV measuring kit for a constant observation.
The proposed project focuses on the development of a heart rate variability measurement system with the use of embedded electronics. …
Induction Of Differentiation Of Dental Pulp-Derived Mesenchymal Stem Cells (Dpsc), Aubrey Young
Induction Of Differentiation Of Dental Pulp-Derived Mesenchymal Stem Cells (Dpsc), Aubrey Young
UNLV Theses, Dissertations, Professional Papers, and Capstones
Mesenchymal stem cells are derived from a variety of human tissues and are being bioengineered and studied for possible uses in the advancement of medicine. Recent efforts are being focused on Dental Pulp Stem Cells (DPSC's) due to the accessibility of this tissue. Many factors influence DPSC quality and quantity, including the specific methods used to isolate, collect, concentrate, and store these isolates once they are removed. Ancillary factors, such as the choice of media, the selection of early versus late passage cells, and cryopreservation techniques may also influence the differentiation potential and proliferative capacity of DPSC isolates.
The objective …
Implementation And Validation Of Aortic Remodeling In Hypertensive Rats, Shijia Zhao, Linxia Gu
Implementation And Validation Of Aortic Remodeling In Hypertensive Rats, Shijia Zhao, Linxia Gu
Department of Mechanical and Materials Engineering: Faculty Publications
A computational framework was implemented and validated to better understand the hypertensive artery remodeling in both geometric dimensions and material properties. Integrating the stress-modulated remodeling equations into commercial finite element codes allows a better control and visualization of local mechanical parameters. Both arterial thickening and stiffening effects were captured and visualized. An adaptive material remodeling strategy combined with the element birth and death techniques for the geometrical growth were implemented. The numerically predicted remodeling results in terms of the wall thickness, inner diameter, and the ratio of elastin to collagen content of the artery were compared with and fine-tuned by …
Design And Development Of A Miniature In Vivo Surgical Robot With Distributed Motor Control For Laparoendoscopic Single-Site Surgery, Eric J. Markvicka
Design And Development Of A Miniature In Vivo Surgical Robot With Distributed Motor Control For Laparoendoscopic Single-Site Surgery, Eric J. Markvicka
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Paradigm shifts in invasiveness, recovery time, cosmesis, and cost have been seen within the field of general surgery through major advances in surgical technology. Some of the most advanced types of general surgery now include Minimally Invasive Surgery (MIS), LaparoEndoscopic Single-Site (LESS) surgery, and Natural Orifice Translumenal Endoscopic Surgery (NOTES). One of the newest and rapidly developing catalysts is robotic platforms. Such platforms have improved ergonomics and control, increased workspace and dexterity, and have surpassed the efficacy of many non-robotic platforms such as traditional laparoscopic surgical tools. This thesis presents the design and development of a four-degree-of-freedom (4- DOF) miniature …
Computational Model Of A Left Ventricle: Showing The Effects Of Inertia On Cardiac Dyssynchrony, Andrew Mcnally, Matthew Korpela, Erin Lamke, Matthew Hudson
Computational Model Of A Left Ventricle: Showing The Effects Of Inertia On Cardiac Dyssynchrony, Andrew Mcnally, Matthew Korpela, Erin Lamke, Matthew Hudson
Journal of Undergraduate Research at Minnesota State University, Mankato
In an effort to research heart failure, a leading cause of death in the industrialized world, this research team has developed a segmented lumped parameter model of the left ventricle. The computations model developed focuses on dyssynchrony, a heart condition where some regions of the heart vary significantly in properties like internal muscle resistance, mass, or elastance. Inertial effects are often assumed as negligible by cardiovascular models. One primary function of this model is to investigate inertial effects as they relate to mechanical cardiac dyssynchrony. An added dimension of this analysis is to observe the thermodynamics of the cardiac cycle …
Fluid Powered Miniature In Vivo Robots For Minimally Invasive Surgery (Mis), Abolfazl Pourghodrat
Fluid Powered Miniature In Vivo Robots For Minimally Invasive Surgery (Mis), Abolfazl Pourghodrat
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Minimizing the invasiveness of surgery is believed to improve patient outcomes. Bleeding, infection, and pain are major concerns in surgery afflicting patients for decades. Minimally invasive techniques have come into play to reduce these concerns and smooth the evolution of abdominal surgery to a scarless process where nearly all surgeries can be performed without a skin incision. Technology continually advances the frontier of development of novel surgical devices to implement less invasive surgical techniques.
Fusion of robotics and Minimally Invasive Surgery (MIS) has created new opportunities to develop diagnostic and therapeutic tools. Surgical robotics is advancing from externally actuated systems …
Preliminary Test Of A Real-Time, Interactive Silent Speech Interface Based On Electromagnetic Articulograph, Jun Wang, Ashok Samal, Jordan R. Green
Preliminary Test Of A Real-Time, Interactive Silent Speech Interface Based On Electromagnetic Articulograph, Jun Wang, Ashok Samal, Jordan R. Green
School of Computing: Conference and Workshop Papers
A silent speech interface (SSI) maps articulatory movement data to speech output. Although still in experimental stages, silent speech interfaces hold significant potential for facilitating oral communication in persons after laryngectomy or with other severe voice impairments. Despite the recent efforts on silent speech recognition algorithm development using offline data analysis, online test of SSIs have rarely been conducted. In this paper, we present a preliminary, online test of a real-time, interactive SSI based on electromagnetic motion tracking. The SSI played back synthesized speech sounds in response to the user’s tongue and lip movements. Three English talkers participated in this …