Articles 121 - 150 of 170

Full-Text Articles in Biomedical Devices and Instrumentation

Development And Evaluation Of A Biocompatible Electroactive Sensor For Continuous Blood Pressure Measurement., Scott D. Cambron May 2017

Development And Evaluation Of A Biocompatible Electroactive Sensor For Continuous Blood Pressure Measurement., Scott D. Cambron

Electronic Theses and Dissertations

Piezo-active composites have been implemented for sensing and transduction for decades. The 0-3 ceramic/polymer composite is one of the most common composite types used for sensing applications, owing to their tailorable properties of the two-phase composition, consisting of a three-dimensionally connected polymer/rubber matrix (inactive phase) with a dispersion of isolated piezo-ceramic particles (active phase). This thesis describes a method to develop novel biocompatible perivascular band comprised of a two-phase piezo-active composite to be fabricated using simple manufacturing processes. Biomaterials such as tissue scaffolds comprised of silk fibroin (SF) and chitosan (CS), and biocompatible soft rubbers will be implemented as the …


Development Of Peritoneal Microbubble Oxygenation As An Extrapulmonary Treatment For Hypoxia, Nathan Legband May 2017

Development Of Peritoneal Microbubble Oxygenation As An Extrapulmonary Treatment For Hypoxia, Nathan Legband

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Patients affected by a respiratory disease or injury experience a substantially impaired respiratory system and as a consequence are unable to obtain a sufficient amount of oxygen. Hypoxia can quickly result in developing permanent tissue damage or death. Currently, the medical methods of treating hypoxia are mechanical ventilation or extracorporeal membrane oxygenation. However, these treatments are ineffective in certain cases and possess significant additional risks including barotrauma, infection, hemorrhage, and thrombosis.

The extrapulmonary method of peritoneal oxygenation has been investigated by other research groups as a potential alternative to providing supplemental oxygen in hypoxic animals. In peritoneal oxygenation, the peritoneum, …


Design And Validation Of An In Vivo Long-Term Attachment Capsule Robot, Wanchuan Xie May 2017

Design And Validation Of An In Vivo Long-Term Attachment Capsule Robot, Wanchuan Xie

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

The invention of capsule endoscopy (CE) made the non-invasive monitoring of the entire small bowel possible and became the primary means for diagnosing small bowel pathology. In the last decade, capsule robots have been transformed from diagnostic devices into a widely studied biomedical platform with the potential for active locomotion, drug delivery and therapeutic capabilities. To perform accurate on-site drug release and therapy, it is necessary for a capsule robot to be able to attach to the intestinal tissue and maintain its position long-term. Design challenges derive from the task of long-term mucosal adhesion which requires firm, quick-response attachment without …


Redesign Of Computer Keyboards For Hospital And Consumer Use, Kent Williams, Brian Jensen, Anton Bowden Feb 2017

Redesign Of Computer Keyboards For Hospital And Consumer Use, Kent Williams, Brian Jensen, Anton Bowden

Biomedical Engineering Western Regional Conference

Application of carbon nanotube coatings to computer keyboards in order to reduce the spread of bacteria in hospitals and homes.

Keywords: carbon nanotube, bacteria, antimicrobial, keyboard, design, MRSA, biofilm


A Nanocomposite Sensor Neck Sleeve For Tracking In Vivo Spine Kinematics In The Alpaca, Colton Porter Graham, Anton Bowden Feb 2017

A Nanocomposite Sensor Neck Sleeve For Tracking In Vivo Spine Kinematics In The Alpaca, Colton Porter Graham, Anton Bowden

Biomedical Engineering Western Regional Conference

Chronic low back pain in the US is often attributed to intervertebral disc degeneration. Camelids, particularly alpacas, pose a potential model for spinal treatment due to similarity of the spinal structure and vertical loading. Alpacas also exhibit a high rate of natural disc degeneration. To gain more understanding about how disc degeneration is caused in alpacas it is necessary to understand the loading and motion of the alpaca cervical spine. The goal of the present work was to incorporate nanocomposite sensors into a custom-designed neck sleeve to track the daily in-vivo neck motion of an alpaca in its natural environment.


Biophysical Tools To Study Cellular Mechanotransduction, Ismeel Muhamed, Farhan Chowdhury, Venkat Maruthamuthu Feb 2017

Biophysical Tools To Study Cellular Mechanotransduction, Ismeel Muhamed, Farhan Chowdhury, Venkat Maruthamuthu

Mechanical & Aerospace Engineering Faculty Publications

The cell membrane is the interface that volumetrically isolates cellular components from the cell's environment. Proteins embedded within and on the membrane have varied biological functions: reception of external biochemical signals, as membrane channels, amplification and regulation of chemical signals through secondary messenger molecules, controlled exocytosis, endocytosis, phagocytosis, organized recruitment and sequestration of cytosolic complex proteins, cell division processes, organization of the cytoskeleton and more. The membrane's bioelectrical role is enabled by the physiologically controlled release and accumulation of electrochemical potential modulating molecules across the membrane through specialized ion channels (e.g., Na, Ca2+, K channels). …


Skintronics: Wireless, Skin-Wearable Electronics For Monitoring Of Electrocardiogram, Matthew B. Piper, Woon-Hong Yeo, Yongkuk Lee Jan 2017

Skintronics: Wireless, Skin-Wearable Electronics For Monitoring Of Electrocardiogram, Matthew B. Piper, Woon-Hong Yeo, Yongkuk Lee

Undergraduate Research Posters

The ECGs I micro-fabricate are designed to be flexible, stretchable and wireless circuits that can be applied to the skin directly. The device is encased in a conformal, silicon-like substrate, that allows the ECG to be attached with the electrodes. Each electrode has been previously measured and verified that it will be correctly placed for an accurate reading. Prototyping this ECG/electrode device allows the user to mount the prototype directly to the patient without having to attach and wire ten other electrodes. This prototype solves the issue that comes about when a doctor, nurse or emergency medical technician must attach …


Final Design Report: Polymer Fatigue Characterization Test Method, Wyatt Ayling, Tyler Price, Brandon Stell, Michela Upson Dec 2016

Final Design Report: Polymer Fatigue Characterization Test Method, Wyatt Ayling, Tyler Price, Brandon Stell, Michela Upson

Mechanical Engineering

Polylogix is a team dedicated to the design, build, and testing of a fatigue machine to simulate cyclic loading on a biomedical polymer. This project is sponsored by Endologix, Inc. to provide test data characterizing mechanical material properties of various formulations of polymer used in abdominal aortic aneurysm surgeries. With this project goal, the machine must be able to test the polymer at body conditions; these include a testing temperature of 37°C and a cycling frequency ranging from 1 Hz to 10 Hz. This report proposes the following solution to this design challenge: an AC motor-driven mechanism utilizing a planetary …


Radiation Therapy And Dosing Material Transport Methodology, Robert O'Brien Dec 2016

Radiation Therapy And Dosing Material Transport Methodology, Robert O'Brien

UNLV Theses, Dissertations, Professional Papers, and Capstones

A technique is examined here that utilizes high energy beta decays from a short lived radioisotope to treat medical conditions such as shallow cancerous lesions. A major benefit of beta particle interaction in tissue is a fixed penetration depth for the charged particle, with dose limited to the ultimate range of the beta particle. This method improves on some current techniques of radioactive brachytherapy, where "seeds" are placed inside patients through temporary or permanent implantation in order to kill cancerous cells or inhibit growth of tissue. The use of low energy gamma-rays is the most common method of treatment currently …


The Effects Of Cryopreservation On Human Dental Pulp-Derived Mesenchymal Stem Cells, Allison Elaine Tomlin Dec 2016

The Effects Of Cryopreservation On Human Dental Pulp-Derived Mesenchymal Stem Cells, Allison Elaine Tomlin

UNLV Theses, Dissertations, Professional Papers, and Capstones

Many studies have demonstrated clinical applications for the use of dental pulp stem cells (DPSC) for the treatment of various conditions. This has driven medical and scientific interest in the collection, isolation and banking of DPSC tissues for research into these potential therapies. Few studies to date have evaluated the viability of DPSC following long-term cryopreservation. The purpose of this study is to evaluate the effects of cryopreservation on dental pulp-derived stem cells (DPSC) viability over a period of three years. Dental pulp-derived stem cells were isolated and cultured from thirty-one healthy teeth. DPSC isolates were assessed for doubling-time and …


An Emg-Based Patient Monitoring System Using Zynq Soc Device, Farhad Fallahlalehzari Dec 2016

An Emg-Based Patient Monitoring System Using Zynq Soc Device, Farhad Fallahlalehzari

UNLV Theses, Dissertations, Professional Papers, and Capstones

This thesis describes the design, development, and testing of an EMG-based patient monitoring system using the Zynq device. Zynq is a system on chip device designed by Xilinx which consists of an ARM dual cortex-A9 processor as well as an FPGA integrated into one chip. This work also analyzes the performance of image-processing algorithms on this system and compares that performance to more traditional PC-based systems. Image processing algorithms, such as Sobel edge detection, dilation and erosion, could be used in conjunction with a camera for the patient monitoring purposes. These algorithms often perform sub-optimally on processors because of their …


Design Of A Flexible Control Platform And Miniature In Vivo Robots For Laparo-Endoscopic Single-Site Surgeries, Lou P. Cubrich Dec 2016

Design Of A Flexible Control Platform And Miniature In Vivo Robots For Laparo-Endoscopic Single-Site Surgeries, Lou P. Cubrich

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Minimally-invasive laparoscopic procedures have proven efficacy for a wide range of surgical procedures as well as benefits such as reducing scarring, infection, recovery time, and post-operative pain. While the procedures have many advantages, there are significant shortcomings such as limited instrument motion and reduced dexterity. In recent years, robotic surgical technology has overcome some of these limitations and has become an effective tool for many types of surgeries. These robotic platforms typically have an increased workspace, greater dexterity, improved ergonomics, and finer control than traditional laparoscopic methods. This thesis presents the designs of both a four degree-of-freedom (DOF) and 5-DOF …


Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee Aug 2016

Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee

The Summer Undergraduate Research Fellowship (SURF) Symposium

Hydrocephalus is a neurological disorder that typically requires a long-term implantation of a shunt system to manage its symptoms. These shunt systems are notorious for their extremely high failure rate. More than 40% of all implanted shunt systems fail within the first year of implantation. On average, 85% of all hydrocephalus patients with shunt systems undergo at least two shunt-revision surgeries within 10 years of implantation. A large portion of this high failure rate can be attributed to biofouling-related obstructions and infections. Previously, we developed flexible polyimide-based magnetic microactuators to remove obstructions formed on hydrocephalus shunts. To test the long-term …


Prosthetic Socket Cooling System, Benjamin K. Kraw, Kathy Ha, Derek Piastrelli, Cuong Lai Jun 2016

Prosthetic Socket Cooling System, Benjamin K. Kraw, Kathy Ha, Derek Piastrelli, Cuong Lai

Mechanical Engineering

A team of four senior-level undergraduate students in the Interdisciplinary Senior Project Design course in the Engineering Department of California Polytechnic State University: San Luis Obispo have worked to develop a prosthetic socket cooling system, namely for veteran Taylor Morris and exclusively for a transfemoral prosthetic socket, under the Quality of Life+ Laboratory. This cooling system will utilize the thermoelectric effect known as the Peltier effect to transmit heat generated from the residual limb to the surrounding environment by means of forced convection over small aluminum heat sinks. Two measurement devices have also been developed to, one, measure the heat …


Improvement Of Mounting Techniques For Accelerated Wear Testing Of Artificial Heart Valves, Kyle Koon, Clay Bougher, Lawrence Yang Jun 2016

Improvement Of Mounting Techniques For Accelerated Wear Testing Of Artificial Heart Valves, Kyle Koon, Clay Bougher, Lawrence Yang

Mechanical Engineering

Confidential


Portable High Throughput Digital Microfluidics And On-Chip Bacteria Cultures, Yiyan Li May 2016

Portable High Throughput Digital Microfluidics And On-Chip Bacteria Cultures, Yiyan Li

UNLV Theses, Dissertations, Professional Papers, and Capstones

An intelligent, portable, and high throughput digital microfluidic (DMF) system is developed. Chapter 1 introduces microfluidics and DMF systems. In Chapter 2, a low-cost and high resolution capacitive-to-digital converter integrated circuit is used for droplet position detection. A field-programmable gate array FPGA is used as the integrated logic hub of the system for highly reliable and efficient control of the circuit. In this chapter a fast-fabricating PCB (printed circuit board) substrate microfluidic system is proposed. Smaller actuation threshold voltages than those previously reported are obtained. Droplets (3 µL) are actuated using 200 V, 500 Hz DC pulses. Droplet positions can …


Design Of Medical Devices For Diagnostics In The Gastrointestinal System, Charles R. Welch Apr 2016

Design Of Medical Devices For Diagnostics In The Gastrointestinal System, Charles R. Welch

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

This thesis presents the design, controls, and testing of two systems: a novel colonoscope locomotion design for diagnostics, and a biosensor capsule that implants a sensor in the small intestine. Each system requires special design considerations for use in the gastrointestinal system.

Colonoscopy procedures are recommended as a screening for colon cancer and related conditions after the age of 50. The need for an improved colonoscope that reduces the colonoscopy time and patient discomfort is apparent. The semi-autonomous device presented here could likely reduce the colonoscopy procedure time by allowing the physician to focus more on the diagnosis and less …


Design And Analysis Of A Lift Assist Walker, Deep P. Shah Mar 2016

Design And Analysis Of A Lift Assist Walker, Deep P. Shah

Master's Theses

Walkers provided stability to the elderly but cannot assist a person from sitting to standing. The objective of this project is to present the design and analysis of a lift assist walker. This report discusses the design and analysis of a collapsible lift assist walker capable of lifting a patient up to 250 lbs. from seated to standing in under 10 seconds. The designed walker utilized a two stage scissor mechanism with a gas spring assisted embedded linear actuator.


Expanded 3d Nanofiber Scaffolds: Cell Penetration, Neovascularization, And Host Response, Jiang Jiang, Zhuoran Li, Hongjun Wang, Yue Wang, Mark A. Carlson, Matthew J. Teusink, Matthew R. Macewan, Linxia Gu, Jingwei Xie Jan 2016

Expanded 3d Nanofiber Scaffolds: Cell Penetration, Neovascularization, And Host Response, Jiang Jiang, Zhuoran Li, Hongjun Wang, Yue Wang, Mark A. Carlson, Matthew J. Teusink, Matthew R. Macewan, Linxia Gu, Jingwei Xie

Department of Mechanical and Materials Engineering: Faculty Publications

Herein, a robust method to fabricate expanded nanofiber scaffolds with controlled size and thickness using a customized mold during the modified gas-foaming process is reported. The expansion of nanofiber membranes is also simulated using a computational fluid model. Expanded nanofiber scaffolds implanted subcutaneously in rats show cellular infiltration, whereas non-expanded scaffolds only have surface cellular attachment. Compared to unexpanded nanofiber scaffolds, more CD68+ and CD163+ cells are observed within expanded scaffolds at all tested time points post-implantation. More CCR7+ cells appear within expanded scaffolds at week 8 post-implantation. In addition, new blood vessels are present within the expanded scaffolds at …


Efficiency Evaluation Of A Magnetically Driven Multiple Disk Centrifugal Blood Pump, Kayla H. Moody Jan 2016

Efficiency Evaluation Of A Magnetically Driven Multiple Disk Centrifugal Blood Pump, Kayla H. Moody

Theses and Dissertations

Heart failure is expected to ail over 8 million people in America by 2030 leaving many in need of cardiac replacement. To accommodate this large volume of people, ventricular assist devices (VADs) are necessary to provide mechanical circulatory support. Current VADs exhibit issues such as thrombosis and hemolysis caused by large local pressure drops and turbulent flow within the pump. Multiple disk centrifugal pumps (MDCPs) use shearing and centrifugal forces to produce laminar flow patterns and eliminate large pressure drops within the pump which greatly reduce risks that are in current VADs. The MDCP has a shaft drive system (SDS) …


Sapien3 Comb Stitch Improvement For Edwards Lifesciences, William Harley, Thomas Pluschkell, John Mctigue, Garrett Reed Jun 2015

Sapien3 Comb Stitch Improvement For Edwards Lifesciences, William Harley, Thomas Pluschkell, John Mctigue, Garrett Reed

Mechanical Engineering

The complete senior project report was submitted to the project advisor and sponsor. The results of this project are of a confidential nature and will not be published at this time.


Designing A Biomimetic Testing Platform For Actuators In A Series-Elastic Co-Contraction System, Ryan Tyler Schroeder Dec 2014

Designing A Biomimetic Testing Platform For Actuators In A Series-Elastic Co-Contraction System, Ryan Tyler Schroeder

UNLV Theses, Dissertations, Professional Papers, and Capstones

Actuators determine the performance of robotic systems at the most intimate of levels. As a result, much work has been done to assess the performance of different actuator systems. However, biomimetics has not previously been utilized as a pretext for tuning a series elastic actuator system with the purpose of designing an empirical testing platform. Thus, an artificial muscle tendon system has been developed in order to assess the performance of two distinct actuator types: (1) direct current electromagnetic motors and (2) ultrasonic rotary piezoelectric motors. Because the design of the system takes advantage of biomimetic operating principles such as …


Induction Of Differentiation Of Dental Pulp-Derived Mesenchymal Stem Cells (Dpsc), Aubrey Young Dec 2014

Induction Of Differentiation Of Dental Pulp-Derived Mesenchymal Stem Cells (Dpsc), Aubrey Young

UNLV Theses, Dissertations, Professional Papers, and Capstones

Mesenchymal stem cells are derived from a variety of human tissues and are being bioengineered and studied for possible uses in the advancement of medicine. Recent efforts are being focused on Dental Pulp Stem Cells (DPSC's) due to the accessibility of this tissue. Many factors influence DPSC quality and quantity, including the specific methods used to isolate, collect, concentrate, and store these isolates once they are removed. Ancillary factors, such as the choice of media, the selection of early versus late passage cells, and cryopreservation techniques may also influence the differentiation potential and proliferative capacity of DPSC isolates.

The objective …


Implementation And Validation Of Aortic Remodeling In Hypertensive Rats, Shijia Zhao, Linxia Gu Sep 2014

Implementation And Validation Of Aortic Remodeling In Hypertensive Rats, Shijia Zhao, Linxia Gu

Department of Mechanical and Materials Engineering: Faculty Publications

A computational framework was implemented and validated to better understand the hypertensive artery remodeling in both geometric dimensions and material properties. Integrating the stress-modulated remodeling equations into commercial finite element codes allows a better control and visualization of local mechanical parameters. Both arterial thickening and stiffening effects were captured and visualized. An adaptive material remodeling strategy combined with the element birth and death techniques for the geometrical growth were implemented. The numerically predicted remodeling results in terms of the wall thickness, inner diameter, and the ratio of elastin to collagen content of the artery were compared with and fine-tuned by …


Cfd Simulation Of The Thermal Performance Of A Parallel Counter-Parallel Flow Heat Exchanger For The Treatment Of Hypothermia, Alex Heller Aug 2014

Cfd Simulation Of The Thermal Performance Of A Parallel Counter-Parallel Flow Heat Exchanger For The Treatment Of Hypothermia, Alex Heller

UNLV Theses, Dissertations, Professional Papers, and Capstones

Hypothermia is a life-threatening condition. Currently, active warming methods are the most effective treatment for dysthermic patients. The aim of this study is to investigate the use of computational fluid dynamics (CFD) in evaluating the thermal performance of a parallel/counter-parallel flow heat exchanger used as part of a fluid warmer to treat Hypothermia. The 3D model of the heat exchanger is divided into three regions; Infusate (fluid to be heated), Hot Water (heating fluid), and a Solid Region (wall). At the end of the heat exchanger, an elbow section is used to create the counter-parallel flow arrangement specific to this …


Fluid Powered Miniature In Vivo Robots For Minimally Invasive Surgery (Mis), Abolfazl Pourghodrat Aug 2014

Fluid Powered Miniature In Vivo Robots For Minimally Invasive Surgery (Mis), Abolfazl Pourghodrat

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Minimizing the invasiveness of surgery is believed to improve patient outcomes. Bleeding, infection, and pain are major concerns in surgery afflicting patients for decades. Minimally invasive techniques have come into play to reduce these concerns and smooth the evolution of abdominal surgery to a scarless process where nearly all surgeries can be performed without a skin incision. Technology continually advances the frontier of development of novel surgical devices to implement less invasive surgical techniques.

Fusion of robotics and Minimally Invasive Surgery (MIS) has created new opportunities to develop diagnostic and therapeutic tools. Surgical robotics is advancing from externally actuated systems …


Subtalar Fusion Fixture Design And Test, Nathan Ortiz Apr 2014

Subtalar Fusion Fixture Design And Test, Nathan Ortiz

Honors Theses

Subtalar arthrodesis is performed when cartilage in the talo-calcaneal (the ankle) joint is degraded in a patient and there are multiple approaches to this surgery. Using synthetic bone material, fixtures were cast from aluminum, using the process of evaporation pattern casting, and epoxy. This casting was used to grip the calcaneus bone of the foot in order to load it mechanically, simulating different scenarios that would be encountered during walking. The relative displacement of the ankle joint was measured using a digital image correlation (DIC) program that was modified to work in both two- and three-dimensional space. This program can …


Biomechanical Performance Of Variable And Fixed Angle Locked Volar Plates For The Dorsally Comminuted Distal Radius, Patrick Atkinson, D. Martineau, J. Shorez, C. Beran, A. G. Dass Jan 2014

Biomechanical Performance Of Variable And Fixed Angle Locked Volar Plates For The Dorsally Comminuted Distal Radius, Patrick Atkinson, D. Martineau, J. Shorez, C. Beran, A. G. Dass

Mechanical Engineering Publications

Background

The ideal treatment strategy for the dorsally comminuted distal radius fracture continues to evolve. Newer plate designs allow for variable axis screw placement while maintaining the advantages of locked technology. The purpose of this study is to compare the biomechanical properties of one variable axis plate with two traditional locked constructs.

Methods

Simulated fractures were created via a distal 1 cm dorsal wedge osteotomy in radius bone analogs. The analogs were of low stiffness and rigidity to create a worst-case strength condition for the subject radius plates. This fracture-gap model was fixated using one of three different locked volar …


Near-Infrared Surface-Enhanced Fluorescence Using Silver Nanoparticles In Solution, Michael D. Furtaw Dec 2013

Near-Infrared Surface-Enhanced Fluorescence Using Silver Nanoparticles In Solution, Michael D. Furtaw

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Fluorescence spectroscopy is a widely used detection technology in many research and clinical assays. Further improvement to assay sensitivity may enable earlier diagnosis of disease, novel biomarker discovery, and ultimately, improved outcomes of clinical care along with reduction in costs. Near-infrared, surface-enhanced fluorescence (NIR-SEF) is a promising approach to improve assay sensitivity via simultaneous increase in signal with a reduction in background. This dissertation describes research conducted with the overall goal to determine the extent to which fluorescence in solution may be enhanced by altering specific variables involved in the formation of plasmonactive nanostructures of dye-labeled protein and silver nanoparticles …


Design Of A Compliant Underactuated Robotic Finger With Coordinated Stiffness, Etienne Dessauw Aug 2013

Design Of A Compliant Underactuated Robotic Finger With Coordinated Stiffness, Etienne Dessauw

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

The concept of underactuation has been previously developed in the robotic field for grasping applications. For these anthropomorphic grippers, the minimization of the number of input signals, or in other words underactuation, is the most expected characteristic. This method has become very popular in recent decades. Indeed, by minimizing the number of input signals, it minimizes the complexity of the system’s control and at the same time avoids increased weight and cost. The inconvenience of such a technique is that the design of this type of system remains a difficult task if the behavior of the underactuated set of joints …