Full-Text Articles in Biomedical Devices and Instrumentation

Fabrication And Characterization Of Nanofiber Nylon-6-Mwcnt As An Electrochemical Sensor For Sodium Ions Concentration Detection In Sweat, Kelsey Mills Jan 2019

Fabrication And Characterization Of Nanofiber Nylon-6-Mwcnt As An Electrochemical Sensor For Sodium Ions Concentration Detection In Sweat, Kelsey Mills

Williams Honors College, Honors Research Projects

Fabrication and characterization nylon-6-MWCNT nanofiber as an electrochemical sensor to detect sodium ion concentrations specifically in sweat. Using contact angle to determine surface morphology and chronoamperometry testing to identify ideal sensor conditions, tests optimized parameters like weight percent of nylon or other polymers, carbon nanotube (CNT) isomer, and solution concentration to determine reproducibility of functional sensors. Utilizing the electric qualities of carbon nanotubes partnered with the sodium ion selectivity of calixarene treatment and polymers unique properties like flexibility and scalability create open an arena for optimizing sodium ion sensors for further development for functional prototypes. Morphology tests showed that the …


Estimation Of Multi-Directional Ankle Impedance As A Function Of Lower Extremity Muscle Activation, Lauren Knop Jan 2019

Estimation Of Multi-Directional Ankle Impedance As A Function Of Lower Extremity Muscle Activation, Lauren Knop

Dissertations, Master's Theses and Master's Reports

The purpose of this research is to investigate the relationship between the mechanical impedance of the human ankle and the corresponding lower extremity muscle activity. Three experimental studies were performed to measure the ankle impedance about multiple degrees of freedom (DOF), while the ankle was subjected to different loading conditions and different levels of muscle activity. The first study determined the non-loaded ankle impedance in the sagittal, frontal, and transverse anatomical planes while the ankle was suspended above the ground. The subjects actively co-contracted their agonist and antagonistic muscles to various levels, measured using electromyography (EMG). An Artificial Neural Network …


Dual-Display Laparoscopic Laser Speckle Contrast Imaging For Real-Time Surgical Assistance, Jaepyeong Cha, Corey Zheng, Lung Wai Lau Nov 2018

Dual-Display Laparoscopic Laser Speckle Contrast Imaging For Real-Time Surgical Assistance, Jaepyeong Cha, Corey Zheng, Lung Wai Lau

Pediatrics Faculty Publications

Laser speckle contrast imaging (LSCI) utilizes the speckle pattern of a laser to determine the blood flow in tissues. The current approaches for its use in a clinical setting require a camera system with a laser source on a separate optical axis making it unsuitable for minimally invasive surgery (MIS). With blood flow visualization, bowel viability, for example, can be determined. Thus, LSCI can be a valuable tool in gastrointestinal surgery. In this work, we develop the first-of-its-kind dual-display laparoscopic vision system integrating LSCI with a commercially available 10mm rigid laparoscope where the laser has the same optical axis as …


Hyperspectral Imaging For Characterizing Single Plasmonic Nanostructure And Single-Cell Analysis, Nishir Sanatkumar Mehta Oct 2018

Hyperspectral Imaging For Characterizing Single Plasmonic Nanostructure And Single-Cell Analysis, Nishir Sanatkumar Mehta

LSU Master's Theses

Orientation of plasmonic nanostructures is an important feature in many nanoscale applications such as photovoltaics, catalyst, biosensors DNA interactions, protein detections, hotspot of surface-enhanced Raman spectroscopy (SERS), and fluorescence resonant energy transfer (FRET) experiments. Silver nanocubes with significant spectral signatures between 400-700 nm are observed in this experimental research. Whereas study of single cells will enable the analysis of cell-to-cell variations within a heterogeneous population. These variations are important for further analysis and understanding of disease propagation, drug development, stem cell differentiation, embryos development, and how cells respond to each other and their environment. Adipose-derived mesenchymal stem cells possess the …


Microfluidic Electrical Impedance Spectroscopy, John J. Foley Sep 2018

Microfluidic Electrical Impedance Spectroscopy, John J. Foley

Master's Theses

The goal of this study is to design and manufacture a microfluidic device capable of measuring changes in impedance valuesof microfluidic cell cultures. Tocharacterize this, an interdigitated array of electrodes was patterned over glass, where it was then bonded to a series of fluidic networks created in PDMS via soft lithography. The device measured ethanol impedance initially to show that values remain consistent over time. Impedance values of water and 1% wt. saltwater were compared to show that the device is able to detect changes in impedance, with up to a 60% reduction in electrical impedance in saltwater. Cells were …


Wearable Assistive Technologies For Autism: Opportunities And Challenges, Emma Mansouri Benssassi, Juan-Carlos Gomez, Louanne E. Boyd, Gillian R. Hayes, Juan Ye Jun 2018

Wearable Assistive Technologies For Autism: Opportunities And Challenges, Emma Mansouri Benssassi, Juan-Carlos Gomez, Louanne E. Boyd, Gillian R. Hayes, Juan Ye

Engineering Faculty Articles and Research

Autism is a lifelong developmental condition that affects how people perceive the world and interact with others. Challenges with typical social engagement, common in the autism experience, can have a significant negative impact on the quality of life of individuals and families living with autism. Recent advances in sensing, intelligent, and interactive technologies can enable new forms of assistive and augmentative technologies to support social interactions. However, researchers have not yet demonstrated effectiveness of these technologies in long-term real-world use. This article presents an overview of the social and sensory challenges of autism, which offer great opportunities and challenges for …


Extended-Use Ecg Monitor, Daniel Aaron Soski Jun 2018

Extended-Use Ecg Monitor, Daniel Aaron Soski

Master's Theses

In this thesis, a prototype ECG monitor was developed that is integrated into an elastic shirt and takes a 3-lead ECG for over 5 days. The high-quality measurements can be used to identify markers indicative of various detrimental heart conditions. Measurements recorded by the device are encrypted and stored onto a micro-SD card. Current Holter monitors are expensive and have functional lives less than 48 hours; however, extended duration monitoring has been proven more useful in diagnosis. The device designed demonstrates that ECG measurements can be taken over longer durations without sacrificing quality, comfort, or device cost.


Design & Delivery Of Automated Winston-Lutz Test For Isocentric & Off-Axis Delivery Stability Utilizing Truebeam Developer Mode & Electronic Portal Imaging Device, Mahmoud Mohammad Yaqoub May 2018

Design & Delivery Of Automated Winston-Lutz Test For Isocentric & Off-Axis Delivery Stability Utilizing Truebeam Developer Mode & Electronic Portal Imaging Device, Mahmoud Mohammad Yaqoub

UNLV Theses, Dissertations, Professional Papers, and Capstones

The uncertainties in treatment delivery cannot be ignored in radiation therapy. Thus, the quality assurance QA tests are very important task of the medical physicist in clinical practice. Assuring the coincidence between the mechanical isocenter of the Linear Accelerator (LINAC) and its radiation beams isocenter is one of the most important qualities need to be tested, and the Winston Lust (WL) test is the

most popular technique to perform this task, especially for the treatment modalities which need high precision in beam delivery such as the stereotactic radiosurgery/stereotactic body radiotherapy (SRS/SBRT). The linear accelerator-based SRS/SBRT is a well-established method in …


Power Mobility Sensor Data Collection Verified Through Standardized Pediatric Assessments, Ayshka Elise Rodriguez-Velez Jan 2018

Power Mobility Sensor Data Collection Verified Through Standardized Pediatric Assessments, Ayshka Elise Rodriguez-Velez

UNF Graduate Theses and Dissertations

The collaboration between the School of Engineering and the Department of Physical Therapy at the University of North Florida has introduced the possibility of creating a new environment for pediatric physical therapy assessments. There are currently no methods for remotely monitoring children with impairments. However, with embedded sensor technology in the form of power mobility and accepted therapy assessment tools, remote monitoring can become a possibility. As a part of this work, a ride-on toy car was developed as a remote monitoring device and a case study with a child with a mobility impairment was used as a proof of …


Gui For Mri-Compatible Neural Stimulator And Recorder, Soo Han Soon, Nishant Babaria, Ranajay Mandal, Zhongming Liu Aug 2017

Gui For Mri-Compatible Neural Stimulator And Recorder, Soo Han Soon, Nishant Babaria, Ranajay Mandal, Zhongming Liu

The Summer Undergraduate Research Fellowship (SURF) Symposium

Functional magnetic resonance imaging (fMRI) and electroencephalography (EEG) are useful tools to analyze brain activities given active stimulation. However, the electromagnetic noise from the MRI distorts the brain signal recording and damages the subject with excessive heat generated on the electrodes attached to the skin. MRI-compatible recording and stimulation systems previously developed at LIBI lab were capable of removing the electromagnetic noise during the imaging process. Previously, the hardware systems had required the integrative software that could control both circuits simultaneously and enable users to easily change recording and stimulation parameters. Graphical user interface (GUI) programmed with computer language informed …


Optimization Of Prosthetic Hands: Utilizing Modularity To Improve Grip Force, Grasp, And Versatility, Jordan William Harris Aug 2017

Optimization Of Prosthetic Hands: Utilizing Modularity To Improve Grip Force, Grasp, And Versatility, Jordan William Harris

UNLV Theses, Dissertations, Professional Papers, and Capstones

It has been demonstrated that although many varieties of upper limb prosthetics exist, commercially available prosthetics are outdated and unsatisfactory. Ineffectiveness and limitations have led to some prosthesis wearers having to own multiple devices, whereas others have given up on them entirely. Even though ample research has been conducted to design and test new hand designs, the industry appears to rest in an overall stagnated state.

It was proposed here, that one problem with prosthetic research is an excess of variables involved in testing, and therefore the improper application of the scientific method. It seems that each time a research …


Skin Tone Tracking Device (Chromaband), Ziyang Bian Jun 2017

Skin Tone Tracking Device (Chromaband), Ziyang Bian

Computer Engineering

It’s long been said that your skin is a window into your health and with many illnesses the first signs of trouble actually show up in your skin. So if we have this natural warning system, then why isn’t anyone able to effectively use it to predict changes in our health? The problem is that currently there is no reliable way to accurately measure the change in skin tone and how these changes may or may not change with variations in health. This project’s aim is to design and develop a device that will record the changes in a user’s …


Poly Drop, Zachary T. Scott, Lilly J. Paul Jun 2017

Poly Drop, Zachary T. Scott, Lilly J. Paul

Computer Engineering

Poly Drop is a software interface to control an Open Drop digital micro-fluidics system. We obtained a hardware system from Gaudi labs. Our task was to create a Graphical User Interface that made the control of the device easier and more automated for better testing. We created software that had 3 parts: a control GUI, arduino code to control the hardware, and Image Analysis that gives the user information such as location and color of liquid drops as they move across the electrode grid of the Open Drop system. The GUI was developed using Java Swing. The communication between the …


3d Printed Microfluidics, Hua Gong, Clayton Ramstedt, Adam T. Woolley, Gregory P. Nordin Feb 2017

3d Printed Microfluidics, Hua Gong, Clayton Ramstedt, Adam T. Woolley, Gregory P. Nordin

Biomedical Engineering Western Regional Conference

3D printing for microfluidic (lab-on-a-chip) devices


Implantable Wireless Sensor Networks: Application To Measuring Temperature For In Vivo Detection Of Infections, Praharsh Madappaly Veetil Jan 2017

Implantable Wireless Sensor Networks: Application To Measuring Temperature For In Vivo Detection Of Infections, Praharsh Madappaly Veetil

Dissertations, Master's Theses and Master's Reports

It is has been proven that infection in the body cause a local temperature increase due to localized inflammation. Therefore, a method to provide early diagnostic or long-term tracking of this infection will provide great benefits to patients with diabetic foot ulcers or sickle cell disease, and those receiving hemodialysis where they suffer from a weakened immune system. The goal of this project is to develop an implantable wireless temperature sensor based on a wireless sensor network system for monitoring infections in situ. The analog signals from the thermistors are digitized and wirelessly transmitted to a computer with an ez430-rf2500 …


A Wireless, Passive Sensor For Measuring Temperature At Orthopedic Implant Sites For Early Diagnosis Of Infections, Salil Sidharthan Karipott Jan 2017

A Wireless, Passive Sensor For Measuring Temperature At Orthopedic Implant Sites For Early Diagnosis Of Infections, Salil Sidharthan Karipott

Dissertations, Master's Theses and Master's Reports

Sensorized implants with embedded wireless, passive temperature sensors were developed for early detection of implant-associated infections. The operation principle of the sensor is based on the hypothesis that infections can lead to an increase in local temperature prior to the rise of body temperature. The sensor was an inductive capacitive (LC) circuit that has been used for monitoring of different parameters wirelessly, often in difficult to access environments. The sensor was fabricated on to an interference screw, which is used for tendon and ligament reconstruction surgeries. In this project, a sensorized interference screw was designed and fabricated by accommodating an …


An Emg-Based Patient Monitoring System Using Zynq Soc Device, Farhad Fallahlalehzari Dec 2016

An Emg-Based Patient Monitoring System Using Zynq Soc Device, Farhad Fallahlalehzari

UNLV Theses, Dissertations, Professional Papers, and Capstones

This thesis describes the design, development, and testing of an EMG-based patient monitoring system using the Zynq device. Zynq is a system on chip device designed by Xilinx which consists of an ARM dual cortex-A9 processor as well as an FPGA integrated into one chip. This work also analyzes the performance of image-processing algorithms on this system and compares that performance to more traditional PC-based systems. Image processing algorithms, such as Sobel edge detection, dilation and erosion, could be used in conjunction with a camera for the patient monitoring purposes. These algorithms often perform sub-optimally on processors because of their …


Radiation Therapy And Dosing Material Transport Methodology, Robert O'Brien Dec 2016

Radiation Therapy And Dosing Material Transport Methodology, Robert O'Brien

UNLV Theses, Dissertations, Professional Papers, and Capstones

A technique is examined here that utilizes high energy beta decays from a short lived radioisotope to treat medical conditions such as shallow cancerous lesions. A major benefit of beta particle interaction in tissue is a fixed penetration depth for the charged particle, with dose limited to the ultimate range of the beta particle. This method improves on some current techniques of radioactive brachytherapy, where "seeds" are placed inside patients through temporary or permanent implantation in order to kill cancerous cells or inhibit growth of tissue. The use of low energy gamma-rays is the most common method of treatment currently …


The Effects Of Cryopreservation On Human Dental Pulp-Derived Mesenchymal Stem Cells, Allison Elaine Tomlin Dec 2016

The Effects Of Cryopreservation On Human Dental Pulp-Derived Mesenchymal Stem Cells, Allison Elaine Tomlin

UNLV Theses, Dissertations, Professional Papers, and Capstones

Many studies have demonstrated clinical applications for the use of dental pulp stem cells (DPSC) for the treatment of various conditions. This has driven medical and scientific interest in the collection, isolation and banking of DPSC tissues for research into these potential therapies. Few studies to date have evaluated the viability of DPSC following long-term cryopreservation. The purpose of this study is to evaluate the effects of cryopreservation on dental pulp-derived stem cells (DPSC) viability over a period of three years. Dental pulp-derived stem cells were isolated and cultured from thirty-one healthy teeth. DPSC isolates were assessed for doubling-time and …


Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee Aug 2016

Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee

The Summer Undergraduate Research Fellowship (SURF) Symposium

Hydrocephalus is a neurological disorder that typically requires a long-term implantation of a shunt system to manage its symptoms. These shunt systems are notorious for their extremely high failure rate. More than 40% of all implanted shunt systems fail within the first year of implantation. On average, 85% of all hydrocephalus patients with shunt systems undergo at least two shunt-revision surgeries within 10 years of implantation. A large portion of this high failure rate can be attributed to biofouling-related obstructions and infections. Previously, we developed flexible polyimide-based magnetic microactuators to remove obstructions formed on hydrocephalus shunts. To test the long-term …


Validation Of A Confocal Light Sheet Microscope Using Push Broom Translation For Biomedical Applications, Joshua Hutcheson May 2016

Validation Of A Confocal Light Sheet Microscope Using Push Broom Translation For Biomedical Applications, Joshua Hutcheson

Graduate Theses and Dissertations

There exists a need for research of optical methods capable of image cytometry suitable for point-of-care technology. To propose am optical approach with no moving parts for simplification of mechanical components for the further development of the technology to the poin-of-care, a linear sensor with push broom translation method. Push broom translation is a method of moving objects by the sensor for an extended field of view. A polydimethylsiloxane (PDMS) microfluidic chamber with a syringe pump was used to deliver objects by the sensor. The volumetric rate of the pump was correlated to the integration time of the sensor to …


Portable High Throughput Digital Microfluidics And On-Chip Bacteria Cultures, Yiyan Li May 2016

Portable High Throughput Digital Microfluidics And On-Chip Bacteria Cultures, Yiyan Li

UNLV Theses, Dissertations, Professional Papers, and Capstones

An intelligent, portable, and high throughput digital microfluidic (DMF) system is developed. Chapter 1 introduces microfluidics and DMF systems. In Chapter 2, a low-cost and high resolution capacitive-to-digital converter integrated circuit is used for droplet position detection. A field-programmable gate array FPGA is used as the integrated logic hub of the system for highly reliable and efficient control of the circuit. In this chapter a fast-fabricating PCB (printed circuit board) substrate microfluidic system is proposed. Smaller actuation threshold voltages than those previously reported are obtained. Droplets (3 µL) are actuated using 200 V, 500 Hz DC pulses. Droplet positions can …


A Software Application For Cardiac-Gated Computerized Tomography Scanning, Stephen Caldwell, Trevor Engelsman Jan 2016

A Software Application For Cardiac-Gated Computerized Tomography Scanning, Stephen Caldwell, Trevor Engelsman

Williams Honors College, Honors Research Projects

Computerized tomography (CT) scans are a common clinical imaging procedure used worldwide. Operating in the X-Ray spectrum, these machines rotate scanners around a stationary body in order to compile two-dimensional images into a unified three-dimensional image. With adjustment to scan frequency and intensity, internal features such as muscles, organs, and tendons can easily be viewed. However, the heart has long evaded CT use due to its near-constant motion. Recently, cardiac-gated scans have entered the market as a technique to image the heart at a specific moment in time when it is nearly still - the quiescent period. Occurring during rapid …


Emlighten, Emily Mulvany Jan 2016

Emlighten, Emily Mulvany

Williams Honors College, Honors Research Projects

This project is focused on creating a system to increase patient satisfaction in hospitals. My senior design team has been working hand in hand with the emergency department of Akron General to design this system called EMlighten. The goal is to create an experience for patients where they exit the hospital feeling more satisfied than they currently are. Patient satisfaction is a key performance indicator used by many hospitals to determine how much additional funding each hospital department is granted. If patients feel more satisfied, not only is that indicative of better care, but departments will receive extra funding. EMlighten …


Assessment Of Optimized Electrode Configuration In Electrical Impedance Myography Study Using Genetic Algorithm Via Finite Element Model, Somen Baidya Jan 2016

Assessment Of Optimized Electrode Configuration In Electrical Impedance Myography Study Using Genetic Algorithm Via Finite Element Model, Somen Baidya

College of Graduate Studies: Theses & Dissertations

Electrical Impedance Myography (EIM) is a neurophysiologic technique in which high- frequency, low-intensity electrical current is applied via surface electrodes over a muscle or muscle group of interest and the resulting electrical parameters (resistance, reactance and phase) are analyzed to isolate diseased muscles from healthy ones. Beside muscle properties, some other anatomic and non-anatomic factors like muscle shape, subcutaneous fat (SF) thickness, inter-electrode distance, etc. also impact the major EIM parameters and thus affect the EIM analysis outcomes. The purpose of this study is to explore the effects of variation in some of these factors impose on EIM parameters and …


Image Processing And Visualization Of Terahertz Pulsed Imaging Of Breast Cancer Tumors, Yuhao Wu Dec 2015

Image Processing And Visualization Of Terahertz Pulsed Imaging Of Breast Cancer Tumors, Yuhao Wu

Graduate Theses and Dissertations

Terahertz imaging technology has grown substantially in recent years. With new advances made in the generation, manipulation, and detection of terahertz radiation, terahertz imaging has found its application as inspection tools in a wide range of areas including biomedicine, materials science, and aerospace industries. In the field of medical imaging, terahertz (THz) has emerged as a new imaging modality due to some fundamental physical properties of the THz wave. THz imaging has been used to examine various biological structures, and THz tomography has been developed to probe the 3D structures of those samples.

THz pulsed imaging (TPI) is one of …


Quantification Of Blood Flow Velocity Using Color Sensing, Aditya Deepak Sanghani Oct 2015

Quantification Of Blood Flow Velocity Using Color Sensing, Aditya Deepak Sanghani

Master's Theses

Blood flow velocity is an important parameter that can give information on several pathologies including atherosclerosis, glaucoma, Raynaud’s phenomenon, and ischemic stroke [2,5,6,10]. Present techniques of measuring blood flow velocity involve expensive procedures such as Doppler echocardiography, Doppler ultrasound, and magnetic resonance imaging [11,12]. They cost from $8500-$20000. It is desired to find a low-cost yet equally effective solution for measuring blood flow velocity. This thesis has a goal of creating a proof of concept device for measuring blood flow velocity.

Finger blood flow velocity is investigated in this project. The close proximity to the skin of the finger’s arteries …


Simulating Low-Frequency Sonic Pulsations To Achieve Thrombolysis, Joseph C. Muskat, Matthew C. Pharris, Charles F. Babbs Aug 2015

Simulating Low-Frequency Sonic Pulsations To Achieve Thrombolysis, Joseph C. Muskat, Matthew C. Pharris, Charles F. Babbs

The Summer Undergraduate Research Fellowship (SURF) Symposium

Cardiovascular thrombosis may result in critical ischemia to a range of anatomical regions, constituting a leading cause of death in the United States. Current invasive treatments for such arterial blockages often yield blood clot recurrence, resulting in repeated hospitalization of patients. This research aims to show how internally introduced pressure oscillations may be used to initiate thrombolysis. We present a novel computational model for determining the resonant frequency and corresponding deformation of an idealized thrombus. Sinusoidal pressure differences across the thrombus induce axial displacements of frequency dependent amplitude. The maximum peak displacement occurs at a resonant frequency of 73 Hz …


Design And Fabrication Techniques Of Devices For Embedded Power Active Contact Lens, Errol Heradio Leon Jun 2015

Design And Fabrication Techniques Of Devices For Embedded Power Active Contact Lens, Errol Heradio Leon

Master's Theses

This thesis designed and fabricated various devices that were interfaced to an IC for an active contact lens that notifies the user of an event by detection of an external wireless signal. The contact lens consisted of an embedded antenna providing communication with a 2.4GHz system, as well as inductive charging at an operating frequency of 13.56 MHz. The lens utilized a CBC005 5µAh thin film battery by Cymbet and a manufactured graphene super capacitor as a power source. The custom integrated circuit (IC) was designed using the On Semiconductor CMOS C5 0.6 µm process to manage …


Mobile Health Sensing With Smart Phones, Abby Logan Wise May 2015

Mobile Health Sensing With Smart Phones, Abby Logan Wise

Electrical Engineering Undergraduate Honors Theses

Depression is a serious mental condition affecting many Americans and people across the world. Postpartum depression is a form of depression affecting women who have recently gone through childbirth. Postpartum depression can have serious symptoms that may affect not only the mother, but her newborn as well. Early detection of these symptoms is of critical importance to the welfare of the mother and her child. Many medical professionals express the need for postpartum screening being that treatment has proven to be very effective. This project aims to make early symptom detection convenient and reliable for mothers with newborns. This will …