Open Access. Powered by Scholars. Published by Universities.®

Analytical, Diagnostic and Therapeutic Techniques and Equipment

Institution
Keyword
Publication Year
Publication
Publication Type

Articles 61 - 71 of 71

Full-Text Articles in Biomedical Devices and Instrumentation

Quantification Of Analyte Concentration From A Paper-Based Lateral Flow Assay Device Using Reflective Sensors, Megan Z. Chiu, Jacqueline Linnes Aug 2015

Quantification Of Analyte Concentration From A Paper-Based Lateral Flow Assay Device Using Reflective Sensors, Megan Z. Chiu, Jacqueline Linnes

The Summer Undergraduate Research Fellowship (SURF) Symposium

Paper-based point-of-care (POC) diagnostics is a growing field in global health due to the extreme portability, accuracy, affordability, and ease of use of these tests. Advancements in recent years have led to more accurate detection and improved functionality using multistep molecular diagnostics. Many such assays utilize lateral flow detection strips for visualization of diagnostic results by eye, which limits the results to qualitative Yes/No readouts. This project focused on combining recent developments in paper-based POC diagnostics to develop and optimize an in-house built quantitative paper-based diagnostic reader for lateral flow detection in low-resource settings. Initially different sensors, including photocell sensors, …


Design And Development Of Two Component Hydrogel Ejector For Three-Dimensional Cell Growth, Thomas Dunkle, Jessica Deschamps, Connie Dam May 2015

Design And Development Of Two Component Hydrogel Ejector For Three-Dimensional Cell Growth, Thomas Dunkle, Jessica Deschamps, Connie Dam

Honors Scholar Theses

Hydrogels are useful in wound healing, drug delivery, and tissue engineering applications, but the available methods of injecting them quickly and noninvasively are limited. The medical industry does not yet have access to an all-purpose device that can quickly synthesize hydrogels of different shapes and sizes. Many synthesis procedures that have been developed result in the formation of amorphous hydrogels. While generally useful, amorphous hydrogels exhibit limited capability in tissue engineering applications, especially due to their viscous properties. This endeavor aims to modulate the appropriate gelation parameters, optimize the injection process, and create a prototype that allows for the extrusion …


Noncontact Diffuse Correlation Tomography Of Breast Tumor, Lian He Jan 2015

Noncontact Diffuse Correlation Tomography Of Breast Tumor, Lian He

Theses and Dissertations--Biomedical Engineering

Since aggressive cancers are frequently hypermetabolic with angiogenic vessels, quantification of blood flow (BF) can be vital for cancer diagnosis. Our laboratory has developed a noncontact diffuse correlation tomography (ncDCT) system for 3-D imaging of BF distribution in deep tissues (up to centimeters). The ncDCT system employs two sets of optical lenses to project source and detector fibers respectively onto the tissue surface, and applies finite element framework to model light transportation in complex tissue geometries. This thesis reports our first step to adapt the ncDCT system for 3-D imaging of BF contrasts in human breast tumors. A commercial 3-D …


Diffuse Optical Measurements Of Head And Neck Tumor Hemodynamics For Early Prediction Of Chemo-Radiation Therapy Outcomes, Lixin Dong Jan 2015

Diffuse Optical Measurements Of Head And Neck Tumor Hemodynamics For Early Prediction Of Chemo-Radiation Therapy Outcomes, Lixin Dong

Theses and Dissertations--Biomedical Engineering

Chemo-radiation therapy is a principal modality for the treatment of head and neck cancers, and its efficacy depends on the interaction of tumor oxygen with free radicals. In this study, we adopted a novel hybrid diffuse optical instrument combining a commercial frequency-domain tissue oximeter (Imagent) and a custom-made diffuse correlation spectroscopy (DCS) flowmeter, which allowed for simultaneous measurements of tumor blood flow and blood oxygenation. Using this hybrid instrument we continually measured tumor hemodynamic responses to chemo-radiation therapy over the treatment period of 7 weeks. We also explored monitoring dynamic tumor hemodynamic changes during radiation delivery. Blood flow data analysis …


Design And Creation Of A Device To Induce Vergence Eye Movements, Jacob B. Jaminet, Paul A. Wetzel Jan 2015

Design And Creation Of A Device To Induce Vergence Eye Movements, Jacob B. Jaminet, Paul A. Wetzel

Undergraduate Research Posters

Automated eye-tracking systems can detect and analyze eye movements as a means to accurately diagnose more than 20 neurological diseases including mild traumatic brain injury. Mild traumatic brain injury is an occurrence of injury to the head resulting from blunt trauma or from acceleration or deceleration forces. Eye movement refers to the voluntary or involuntary movement of the eyes, helping in acquiring, fixating and tracking visual stimuli. There are three types of voluntary eye movement to track objects: smooth pursuit, vergence shifts and saccades. Vergence shifts are eye movements where the eyes move in opposite directions: moving to the midline …


Design And Development Of A Miniature In Vivo Surgical Robot With Distributed Motor Control For Laparoendoscopic Single-Site Surgery, Eric J. Markvicka Aug 2014

Design And Development Of A Miniature In Vivo Surgical Robot With Distributed Motor Control For Laparoendoscopic Single-Site Surgery, Eric J. Markvicka

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Paradigm shifts in invasiveness, recovery time, cosmesis, and cost have been seen within the field of general surgery through major advances in surgical technology. Some of the most advanced types of general surgery now include Minimally Invasive Surgery (MIS), LaparoEndoscopic Single-Site (LESS) surgery, and Natural Orifice Translumenal Endoscopic Surgery (NOTES). One of the newest and rapidly developing catalysts is robotic platforms. Such platforms have improved ergonomics and control, increased workspace and dexterity, and have surpassed the efficacy of many non-robotic platforms such as traditional laparoscopic surgical tools. This thesis presents the design and development of a four-degree-of-freedom (4- DOF) miniature …


Fluid Powered Miniature In Vivo Robots For Minimally Invasive Surgery (Mis), Abolfazl Pourghodrat Aug 2014

Fluid Powered Miniature In Vivo Robots For Minimally Invasive Surgery (Mis), Abolfazl Pourghodrat

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Minimizing the invasiveness of surgery is believed to improve patient outcomes. Bleeding, infection, and pain are major concerns in surgery afflicting patients for decades. Minimally invasive techniques have come into play to reduce these concerns and smooth the evolution of abdominal surgery to a scarless process where nearly all surgeries can be performed without a skin incision. Technology continually advances the frontier of development of novel surgical devices to implement less invasive surgical techniques.

Fusion of robotics and Minimally Invasive Surgery (MIS) has created new opportunities to develop diagnostic and therapeutic tools. Surgical robotics is advancing from externally actuated systems …


Utilizing Fast Spin Echo Mri To Reduce Image Artifacts And Improve Implant/Tissue Interface Detection In Refractory Parkinson’S Patients With Deep Brain Stimulators, Subhendra N. Sarkar, Pooja R. Sarkar, Efstathios Papavassiliou, Rafael Rojas Feb 2014

Utilizing Fast Spin Echo Mri To Reduce Image Artifacts And Improve Implant/Tissue Interface Detection In Refractory Parkinson’S Patients With Deep Brain Stimulators, Subhendra N. Sarkar, Pooja R. Sarkar, Efstathios Papavassiliou, Rafael Rojas

Publications and Research

Introduction. In medically refractory Parkinson’s disease (PD) deep-brain stimulation (DBS) is an effective therapeutic tool. Postimplantation MRI is important in assessing tissue damage and DBS lead placement accuracy. We wanted to identify which MRI sequence can detectDBS leads with smallest artifactual signal void, allowing better tissue/electrode edge conspicuity.

Methods. Using an IRB approved protocol 8 advanced PDpatientswere imagedwithinMRconditional safety guidelines at lowRF power (SAR ≤ 0.1 W/kg) in coronal plane at 1.5T by various sequences.The image slices were subjectively evaluated for diagnostic quality and the lead contact diameters were compared to identify a sequence least affected by metallic leads.

Results …


Automated Point-Of-Care Image Processing Methodology For The Diagnosis Of Malaria, Michael B. Jorgensen Jan 2013

Automated Point-Of-Care Image Processing Methodology For The Diagnosis Of Malaria, Michael B. Jorgensen

Master's Theses

Malaria has profoundly influenced human history for over four thousand years and despite numerous attempts at eradication, the prevention, diagnosis, and treatment of malaria have been largely ineffective. More than five hundred million people are affected by malaria every year resulting in over one million deaths. Drug resistance development by the parasite has diminished the effectiveness of numerous treatment options due, in part, to overtreatment of negative patients based on insufficient clinical algorithms and diagnostic methods. The goal of this research was to develop an image analysis algorithm to diagnose malaria with a high degree of sensitivity and specificity in …


Cyberknife Radiation Modeling: Effects Of Relaxed Translational And Rotational Constraints On Healthy Tissue Irradiation, Sudha Bhavaroop Potineni Jul 2011

Cyberknife Radiation Modeling: Effects Of Relaxed Translational And Rotational Constraints On Healthy Tissue Irradiation, Sudha Bhavaroop Potineni

Electrical & Computer Engineering Theses & Dissertations

The Cyberknife system is a robotic radio surgery instrument that is used to treat cancers in different parts of the human body. Because of its accuracy and precision, it has become one of the best radio surgery systems in the world. However, even with Cyberknife the treatment time for one session takes from 30 minutes up to 120 minutes depending on the size, shape, and position of the tumor in the human body. In this research, a solution is presented to aid in reducing this long treatment time. An algorithm is developed which simulates the amount of the healthy tissue …


Laser Etched Pmma Microfluidic Chip Design And Manufacture With Applications In Capillary Zone Electrophoresis, Evan Allen Barbre Feb 2011

Laser Etched Pmma Microfluidic Chip Design And Manufacture With Applications In Capillary Zone Electrophoresis, Evan Allen Barbre

Master's Theses

This thesis encompasses a feasibility study of using low-cost materials to manufacture microfluidic chips that can perform the same functions as chips manufactured using traditional methods within an acceptable range of efficiency of chips created with more exotic methods and materials. The major parts of the project are the selection and characterization of the fabrication methods for creating the channels for fluid flow, the methods for sealing the channels to create a usable chip and the electrophoretic separations of carboxylated microspheres of different potentials. In this work we seek to answer the question if laser-etched PMMA microfluidic chips are comparable …