Open Access. Powered by Scholars. Published by Universities.®
Biomechanics and Biotransport Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- California Polytechnic State University, San Luis Obispo (16)
- University of Arkansas, Fayetteville (10)
- The University of Akron (7)
- City University of New York (CUNY) (5)
- Clemson University (5)
-
- University of Kentucky (4)
- University of Connecticut (3)
- University of Nebraska - Lincoln (3)
- Dartmouth College (2)
- Loma Linda University (2)
- Old Dominion University (2)
- Universitas Indonesia (2)
- University of Central Florida (2)
- University of Denver (2)
- University of Louisville (2)
- University of Nebraska at Omaha (2)
- Virginia Commonwealth University (2)
- Washington University in St. Louis (2)
- Boise State University (1)
- Duquesne University (1)
- Florida Institute of Technology (1)
- Grand Valley State University (1)
- Louisiana State University (1)
- Marquette University (1)
- Michigan Technological University (1)
- Purdue University (1)
- Southern Illinois University Edwardsville (1)
- Southern Methodist University (1)
- Technological University Dublin (1)
- The University of Southern Mississippi (1)
- Keyword
-
- Biomechanics (6)
- Microfluidics (6)
- Biomedical (4)
- Device (3)
- Finite element analysis (3)
-
- Tissue Engineering (3)
- Walking (3)
- Biomedical Engineering (2)
- Breast cancer (2)
- Cell stiffness (2)
- Daniel Felix Ritchie School of Engineering and Computer Science (2)
- Electromyography (2)
- Engineering (2)
- Ergonomics (2)
- Exoskeleton (2)
- Hip Joint (2)
- Kinematics (2)
- Mechanical (2)
- Mechanical and Materials Engineering (2)
- Microfabrication (2)
- Minimally invasive surgery (2)
- OpenSim (2)
- Prosthesis (2)
- Prosthetic (2)
- Rehabilitation (2)
- Total knee arthroplasty (2)
- 3D Printing (1)
- 3D Stem Cell Culture (1)
- 3D printing (1)
- 3D-Printing (1)
- Publication Year
- Publication
-
- Biomedical Engineering (9)
- Biomedical Engineering Undergraduate Honors Theses (8)
- Master's Theses (8)
- Williams Honors College, Honors Research Projects (7)
- Electronic Theses and Dissertations (5)
-
- All Theses (4)
- Dissertations and Theses (4)
- Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research (2)
- Graduate Theses and Dissertations (2)
- Honors Scholar Theses (2)
- Honors Theses (2)
- Honors Undergraduate Theses (2)
- Loma Linda University Electronic Theses, Dissertations & Projects (2)
- Makara Journal of Technology (2)
- McKelvey School of Engineering Graduate Student Theses & Dissertations (2)
- Mechanical & Aerospace Engineering Faculty Publications (2)
- Theses and Dissertations (2)
- Theses and Dissertations--Biomedical Engineering (2)
- UNO Student Research and Creative Activity Fair (2)
- All Dissertations (1)
- Biology and Medicine Through Mathematics Conference (1)
- Biomedical Engineering: Graduate Reports and Projects (1)
- Boise State University Theses and Dissertations (1)
- Conference Papers (1)
- Dartmouth College Undergraduate Theses (1)
- Department of Mechanical and Materials Engineering: Faculty Publications (1)
- Dissertations, Master's Theses and Master's Reports (1)
- ENGS 88 Honors Thesis (AB Students) (1)
- Graduate Theses, Dissertations, and Problem Reports (ETD) (1)
- LSU Doctoral Dissertations (1)
- Publication Type
Articles 31 - 60 of 91
Full-Text Articles in Biomechanics and Biotransport
Nano-, Encapsulated Manganese Oxide (Nemo) Particles For Mri Enhancement In Microfluidic Tumor Models, Kasey Alexis Freshwater
Nano-, Encapsulated Manganese Oxide (Nemo) Particles For Mri Enhancement In Microfluidic Tumor Models, Kasey Alexis Freshwater
Graduate Theses, Dissertations, and Problem Reports (ETD)
Breast cancer is among the deadliest cancers in women, with approximately 2.3 million new cases and 685,000 deaths reported globally in 2020 alone. Magnetic Resonance Imaging (MRI) is commonly used to diagnose, stage, and develop treatment plans for patients predisposed to breast cancer. However, current MRI-based screening of breast cancer has high false-positive rates up to 25%, leading to unnecessary invasive follow-up screening and testing. The gold-standard intravenous gadolinium (Gd)-based contrast agents (GBCAs) account for false-positive rates because they are always “ON”, providing a constant MRI signal that highlights both benign and malignant tumors. The work detailed in this thesis …
Impact Of Percutaneous Transluminal Intervention On Vascular Hypoxia And The Role Of Micro-Calcifications On Atherosclerotic Plaque Rupture, Andrea Corti
Dissertations and Theses
Atherosclerotic disease is initiated by cholesterol build-up beneath the endothelium, which evolves into a fibroatheroma, a lipid-rich plaque covered by a fibrous cap. Many of these plaques are considered as vulnerable, as they grow to occlude the luminal section of the artery (chronically stenotic) or become mechanically unstable with a higher chance of rupturing (rupture-prone). On one hand, chronically stenotic vulnerable plaques are symptomatic lesions that are often treated with Percutaneous Transluminal Intervention (PTI). Unfortunately, approximately 10% of PTI procedures are followed by severe Neointima Hyperplasia (NH), which causes a new occlusion and failure of the implant. A significant precursor …
Classifying Common Knee Rehabilitation Exercise Mistakes Using Imu Data, Fedor Myagkov
Classifying Common Knee Rehabilitation Exercise Mistakes Using Imu Data, Fedor Myagkov
Dartmouth College Undergraduate Theses
Physical therapy following major surgeries is a branch of medicine that has seen its fair share of technologically inspired advances. One important facet of physical therapy, the “at-home exercises” patients are prescribed to do, is still somewhat of a “black box” to many physical therapists (PTs). PTs have no way of knowing (1) whether the patient is doing the home exercises, or (2) whether the patient is doing the exercises in the correct and healthy manner. This lack of awareness makes it difficult for the PT to guide the patient, which can often lead to prolonged rehabilitation periods or (sometimes) …
Flywheel Fanny Pack Balance Assist, Ella Joy Mahood, Jason Scott Provol, Raymond Ming Tseng
Flywheel Fanny Pack Balance Assist, Ella Joy Mahood, Jason Scott Provol, Raymond Ming Tseng
Biomedical Engineering
The aim of this project is to develop a wearable device that will provide support to a balance impaired individual. The device will be predicated on the principle of gyroscopes. It will include a rapidly spinning flywheel, which will resist any changes to spatial orientation.
New Force Transducer For Mitral Valve Chordae Tendinea, Joseph Berryman
New Force Transducer For Mitral Valve Chordae Tendinea, Joseph Berryman
Biomedical Engineering Undergraduate Honors Theses
In order to inform the future of mitral valve repair and replacement, more investigation into the mechanics of the sub-valvular structure is needed. Understanding the roles of each chord during valve closure requires a sensor capable of detecting these small forces with enough sensitivity to determine the characteristics of each of the chordal types. The focus of the cantilever force transducer is to maximize this sensitivity while also minimizing the invasiveness of the sensor on the overall function of the chord. The design utilizes flexible yet strong 3D printed resin and cantilever arms to improve the strain exerted on a …
Safety Analysis Of Battery-Powered Adaptive Ride-On Toys For Children With Disabilities, Abbey Fraser
Safety Analysis Of Battery-Powered Adaptive Ride-On Toys For Children With Disabilities, Abbey Fraser
UNF Graduate Theses and Dissertations
Modified battery-powered ride-on toy cars, or adaptive ride-on toys, represent novel rehabilitation tools and developmental aids for children with disabilities. Studies have shown that children are benefiting socially and developmentally from their use. However, the use of these toys by children with disabilities potentially poses a risk of injury and it is vitally important to ensure the safe use of these toys, particularly for the benefit of those with developmental challenges.
Within this context, the purpose of the first study was to determine whether modifications to ride-on toys are sufficient to prevent common modes of injury such as falls, passenger …
Development Of Light Actuated Chemical Delivery Platform On A 2-D Array Of Micropore Structure, Hojjat Rostami Azmand, Hojjat Rostami Azmand
Development Of Light Actuated Chemical Delivery Platform On A 2-D Array Of Micropore Structure, Hojjat Rostami Azmand, Hojjat Rostami Azmand
Dissertations and Theses
Localized chemical delivery plays an essential role in the fundamental information transfers within biological systems. Thus, the ability to mimic the natural chemical signal modulation would provide significant contributions to understand the functional signaling pathway of biological cells and develop new prosthetic devices for neurological disorders. In this paper, we demonstrate a light-controlled hydrogel platform that can be used for localized chemical delivery in a high spatial resolution. By utilizing the photothermal behavior of graphene-hydrogel composites confined within micron-sized fluidic channels, patterned light illumination creates the parallel and independent actuation of chemical release in a group of fluidic ports. The …
Development Of A Biaxial Testing System For Research Of Soft Tissue Biomechanics Using Laboratory Models, Tariq Shameen
Development Of A Biaxial Testing System For Research Of Soft Tissue Biomechanics Using Laboratory Models, Tariq Shameen
Dissertations and Theses
The rupture of the cap tissue layer of a fibroatheroma in human coronary vessels is considered the key event leading to the formation of a thrombus and myocardial infarction, resulting in more than half a million deaths in the US every year. In this study, we are interested in investigating the biomechanics of different elastomer materials that can be used as laboratory models to replicate coronary arteries’ ultimate tensile stress (0.2 - 2.08 MPa). To this end, we developed a biomechanical testing system that allows us to characterize the material properties of small samples with high accuracy and precision. We …
Utilizing Neural Networks And Wearables To Quantify Hip Joint Angles And Moments During Walking And Stair Ascent, Megan V. Mccabe
Utilizing Neural Networks And Wearables To Quantify Hip Joint Angles And Moments During Walking And Stair Ascent, Megan V. Mccabe
ENGS 88 Honors Thesis (AB Students)
Wearable sensors were leveraged to develop two methods for computing hip joint angles and moments during walking and stair ascent that are more portable than the gold standard. The Insole-Standard (I-S) approach replaced force plates with force-measuring insoles and achieved results that match the curvature of results from similar studies. Peaks in I-S kinetic results are high due to error induced by applying the ground reaction force to the talus. The Wearable-ANN (W-A) approach combines wearables with artificial neural networks to compute the same results. Compared against the I-S, the W-A approach performs well (average rRMSE = 18%, R2 …
Redesign And Quantitative Assessment Of An Accelerated Venous Valve Fatigue Apparatus, Megan Kueh
Redesign And Quantitative Assessment Of An Accelerated Venous Valve Fatigue Apparatus, Megan Kueh
Biomedical Engineering Undergraduate Honors Theses
Chronic venous insufficiency (CVI) is a form of cardiovascular disease that is caused when valves in the leg become incompetent. Current treatment methods serve to manage symptoms, but there are currently no ways to treat the underlying cause of CVI. A venous valve prosthetic made from a xenograft of a bovine jugular vein is one possible treatment method currently in the research phase. Prosthetic valves must be tested with an accelerated wear tester prior to approval for clinical testing. Although such testers exist for heart valves, physiological differences between heart and venous valves restrict the use those testers on venous …
Mechanical Analysis Of In Vitro Tbi Models, Dana Hamed
Mechanical Analysis Of In Vitro Tbi Models, Dana Hamed
Honors Scholar Theses
This work details the damage done to cells when mechanically hit. The goal was to mechanically analyze in vitro traumatic brain injury (TBI) models. Parts were designed in SolidWorks to create the machine that is used to induce this damage on the cells. A force applicator that uses a 3D-printed micro-hammer to apply force on the brain cells that are being tested was created. Mechanical trauma experimentation was performed with the force applicator, while a high-speed camera recorded the damage, in order to analyze TBI models. Displacement along the scaffold can be tracked from multiple video frames. With these results, …
Solostand, Hau Nhat Doan, Sydney Gray, Celina Dioso
Solostand, Hau Nhat Doan, Sydney Gray, Celina Dioso
Biomedical Engineering
The purpose of this scope of work is to highlight the progress and development of SoloStand sponsored by Derek Herrera, chief technical officer and founder of SpinalSingularity. SoloStand is an attachment to a wheelchair that will benefit paraplegics that use wheelchairs. A portable and customizable attachment to a wheelchair will allow the user to do everyday tasks without transferring into a separate standing wheelchair and travel more easily. This document outlines everything that has been done in fulfillment of our senior project requirements.
On-Body Pressure For Subcutaneous Infusion Of Drug, Hannah Cole, Kayla Meacham, Eleanor Moran, Kaylee Voss
On-Body Pressure For Subcutaneous Infusion Of Drug, Hannah Cole, Kayla Meacham, Eleanor Moran, Kaylee Voss
Biomedical Engineering
No abstract provided.
Knee Joint Loading Following Anterior Cruciate Ligament Reconstruction: Link To Patient Reported Outcomes And A Novel Method To Monitor With Wearable Sensors, Alex Spencer
Theses and Dissertations--Kinesiology and Health Promotion
Recovery from anterior cruciate ligament reconstruction (ACLR) commonly results in undesirable physical and patient-reported outcomes (PROs). Identification of modifiable factors such as knee contact force (KCF) early in rehabilitation that can improve these outcomes is important due to the rapid decrease in function, quality of life, and joint health in this population. Additionally, if noninvasive measurement of KCFs outside of a traditional laboratory were possible, clinicians could optimize patient treatment with personalized care. Therefore, there are two primary aims to this thesis: 1) quantify the link between KCF and PROs which measure pain, ability to perform activities of daily living, …
The Tera Multi Terrain Mobility Aid Chassis, Colton Kemp, Daniel Nicoll, Ibrahim Suleiman, Mohammad Alyami
The Tera Multi Terrain Mobility Aid Chassis, Colton Kemp, Daniel Nicoll, Ibrahim Suleiman, Mohammad Alyami
Williams Honors College, Honors Research Projects
The natural environment poses a significant number of obstacles and dynamic settings that makes mobility difficult for those with physical and mobility impairments. To approach this problem, a suspension was designed using inspiration from the early Mars rovers developed by NASA for traversing the varied Martian landscape. The course of the project followed the direction of a start-up through problem identification, early design generation and review, and final design production. The project outcome, through client request and proven market research, aimed to produce a multi-terrain wheelchair. The final product is a kinematic body with mobile front “legs” and a rotational …
Upper Extremity Mobility Device, Timothy J. Grassi, Jacob R. Miller
Upper Extremity Mobility Device, Timothy J. Grassi, Jacob R. Miller
Williams Honors College, Honors Research Projects
The goal of this project was to evaluate a clinical problem, explore possible solutions, and produce a functioning prototype that would conform to all the established guidelines and requirements. The project focused on developing an upper extremity mobility device for a singular client with limited muscle activity in his arms due to childhood polio. Our design process was governed by an adapted form of the FDA Design Control Process, 21 CFR 820.30 [1]. The outcome of this project was a functioning prototype that utilized the concept of a motorized pulley system remote controlled using a key fob. This research project …
All-Wheel-Ukraine, Sofiya Rakovska, Hannah Mcculloch, Andrey Garasimchuk, Ahmad Alsaihati
All-Wheel-Ukraine, Sofiya Rakovska, Hannah Mcculloch, Andrey Garasimchuk, Ahmad Alsaihati
Williams Honors College, Honors Research Projects
We are working with a non-profit organization in Ukraine that provides wheelchairs/strollers to families of disables children who cannot afford them. Their current preferred solution is a baby stroller. The organization asked us to create a wheelchair that is cost efficient, light and collapsible to be used for children ages up to thirteen years old. We will be creating an alpha prototype wheelchair by modifying a basic wheelchair that we purchased. This modifications include adding a headrest that is adjustable and provides a sufficient support for children within the age group given to us and diverse levels of disabilities. We …
Lower Extremity Exoskeleton, Kelly Haslett, Jacalyn Everhart
Lower Extremity Exoskeleton, Kelly Haslett, Jacalyn Everhart
Williams Honors College, Honors Research Projects
Develop a lower extremity device that provides assistance, support, and gait correction for children with cerebral palsy who display crouch gait as a symptom. The device will be designed for children ages 7-12. The device will be adjustable to accommodate varying levels of gait irregularity, weakness and human growth. The device would assist walking and stair climbing by providing bilateral support at hips, knees and ankle joints. The device will be designed for ease of donning and doffing. Battery, drive and control electronics will be designed to reside in a minimalistic backpack (outside the scope of this project).
Development Of A Torque-Based Device For The Quantification Of Arm Rigidity In Patients With Parkinson’S Disease, Georgina O. Miller
Development Of A Torque-Based Device For The Quantification Of Arm Rigidity In Patients With Parkinson’S Disease, Georgina O. Miller
Theses and Dissertations
Parkinsonian rigidity is caused by the inability of the muscles to relax and extend properly, due to reduced dopamine levels and often begins on one side of the body before spreading contralaterally. The current standard for determining joint rigidity in a clinical setting is a test completed by the clinician based on the feel of the relaxed wrist and elbow joints as they are passively flexed and extended and a series of ordinal rating scales, the Movement Disorder Society’s – Unified Parkinson’s Disease Rating Scale (MDS-UPDRS), Hoehn and Yahr Scale (H&Y), and Parkinson’s Disease Questionnaire-39 (PDQ-39). These methods are used …
Transcatheter Mitral Valve Replacement: Structural And Hemodynamic Analysis, Saba Ravaghi
Transcatheter Mitral Valve Replacement: Structural And Hemodynamic Analysis, Saba Ravaghi
Electronic Theses and Dissertations
Transcatheter mitral valve replacement (TMVR) is being developed to become a substitute therapy for surgery in prohibitive or high surgical risk patients to treat severe mitral regurgitation. A limited number of TMVR systems are under clinical evaluation. However, transcatheter mitral valve (TMV) long-term durability and hemodynamic performance is not known. TMV durability and hemodynamics must match with that of surgical bioprostheses for potential commercialization of TMVR. Experimental and computational approaches were used to find the leaflets’ three-dimensional anisotropic mechanical properties in a transcatheter Edwards SAPIEN 3 valve and a surgical Carpentier-Edwards PERIMOUNT Magna mitral valve and finite element (FE) simulations …
Development Of A Statistical Shape-Function Model Of The Implanted Knee For Real-Time Prediction Of Joint Mechanics, Kalin Gibbons
Development Of A Statistical Shape-Function Model Of The Implanted Knee For Real-Time Prediction Of Joint Mechanics, Kalin Gibbons
Boise State University Theses and Dissertations
Outcomes of total knee arthroplasty (TKA) are dependent on surgical technique, patient variability, and implant design. Non-optimal design or alignment choices may result in undesirable contact mechanics and joint kinematics, including poor joint alignment, instability, and reduced range of motion. Implant design and surgical alignment are modifiable factors with potential to improve patient outcomes, and there is a need for robust implant designs that can accommodate patient variability. Our objective was to develop a statistical shape-function model (SFM) of a posterior stabilized implant knee to instantaneously predict output mechanics in an efficient manner. Finite element methods were combined with Latin …
Transmission Probability Of Embolic Debris Through The Aortic Arch And Daughter Vessels During A Transcatheter Aortic Valve Replacement Procedure, Jessica Lena Wirth
Transmission Probability Of Embolic Debris Through The Aortic Arch And Daughter Vessels During A Transcatheter Aortic Valve Replacement Procedure, Jessica Lena Wirth
Master's Theses
Cerebral ischemia leading to an ischemic stroke is a possible complication of a transcatheter aortic valve replacement (TAVR) procedure. This is because embolic debris can become dislodged and travel through the aortic arch, where they either continue to the descending aorta and join the systemic circulation or travel into the cerebral vasculature through the three daughter vessels that branch off the top of the aortic arch. These three vessels are the brachiocephalic artery, the left subclavian artery, and the left common carotid artery. These three vessels lead either directly or indirectly to the cerebral vasculature, where the diameter of vessels …
Sand Foot: A Prosthesis For Walking On Sand, Samantha A. Galicinao, John Dewing, Daniel Dugan Dotson, Christopher Urasaki
Sand Foot: A Prosthesis For Walking On Sand, Samantha A. Galicinao, John Dewing, Daniel Dugan Dotson, Christopher Urasaki
Biomedical Engineering
This critical design report describes the product development of a prosthesis for use on sand. Quality of Life Plus (QL+), a national non-profit organization aimed to develop prostheses for veterans and people with disabilities, introduced this project and its accompanying challenger, Sgt. Brady, to Cal Poly’s Interdisciplinary Senior Project class in September 2018. After consulting with Sgt. Brady and QL+ and performing extensive research, the Sand Foot team defined customer requirements and engineering specifications to meet these requirements. Comfortability, durability, and sandproof were key customer requirements. Several conceptual models were brainstormed and a final design was selected based on the …
Developing An Optomechanical Approach For Characterizing Mechanical Properties Of Single Adherent Cells, Ali Mehrnezhad
Developing An Optomechanical Approach For Characterizing Mechanical Properties Of Single Adherent Cells, Ali Mehrnezhad
LSU Doctoral Dissertations
Mechanical properties of a cell reflect its biological and pathological conditions including cellular disorders and fundamental cellular processes such as cell division and differentiation. There have been active research efforts to develop high-throughput platforms to mechanically characterize single cells. Yet, many of these research efforts are focused on suspended cells and use a flow-through configuration. Therefore, adherent cells are detached prior to the characterization, which seriously perturbs the cellular conditions. Also, methods for adherent cells are limited in their throughput.
My study is aimed to fill the technical gap in the field of single cell analysis, which is a high-throughput …
Vector Flow Imaging In Pediatric Cardiology - Extracting And Validating Data, Mason Belue
Vector Flow Imaging In Pediatric Cardiology - Extracting And Validating Data, Mason Belue
Biomedical Engineering Undergraduate Honors Theses
In the field of bedside cardiac diagnostic imaging, Doppler Ultrasound (DU) is the gold standard for diagnosing heart conditions. The largest benefit of DU is its ability to noninvasively image cardiac flow and allow the estimation of blood velocity and quantification of anatomical disease. However, to get correct velocity estimation, the position of the transducer in relation to the flow field needs to be known. This is the problem of angle/direction dependency and limits DUs accuracy when imaging in areas where perfect alignment or exact position of the transducer in relation to flow field is not possible or known, such …
Effects Of A Passive Dynamic Lower-Leg Exoskeleton During Walking, Blake Beier
Effects Of A Passive Dynamic Lower-Leg Exoskeleton During Walking, Blake Beier
UNO Student Research and Creative Activity Fair
The ankle joint is one of the most important joints during walking. If the muscles surrounding the ankle are weak, there are reductions in the ability to generate appropriate torques and powers at the ankle. This leads to slower self-selected walking speeds, which correlate with poor physical functioning, more disabilities, increased hospitalization visits and costs, and even mortality. Because of this, many orthotic and exoskeletal devices have been created to restore proper ankle function by promoting ankle plantar flexion. Utilizing 3D printing and an extension spring, we created an easily accessible, reproducible, and modifiable exoskeleton that has the potential to …
Fluid Delivery System For A Cell Culture On A Microfluidic Chip, Austin J. Roeder, Colleen A. Richards, Emily A. Matteson
Fluid Delivery System For A Cell Culture On A Microfluidic Chip, Austin J. Roeder, Colleen A. Richards, Emily A. Matteson
Biomedical Engineering
This project report provides a description of the progress made in the development of a fluid delivery system for a microfluidic cell culture on a chip. The system is intended to be used in a humidified incubator in a university laboratory and the fluid delivery system is required to exist and operate within that incubator for extended periods of time. Therefore, the system will be gravity-driven and contain no electronic components. The key specification of the system is to provide fluid flow at a constant velocity.
After manufacturing and testing the device, all specifications were met except for the fluid …
Estimation Of Multi-Directional Ankle Impedance As A Function Of Lower Extremity Muscle Activation, Lauren Knop
Estimation Of Multi-Directional Ankle Impedance As A Function Of Lower Extremity Muscle Activation, Lauren Knop
Dissertations, Master's Theses and Master's Reports
The purpose of this research is to investigate the relationship between the mechanical impedance of the human ankle and the corresponding lower extremity muscle activity. Three experimental studies were performed to measure the ankle impedance about multiple degrees of freedom (DOF), while the ankle was subjected to different loading conditions and different levels of muscle activity. The first study determined the non-loaded ankle impedance in the sagittal, frontal, and transverse anatomical planes while the ankle was suspended above the ground. The subjects actively co-contracted their agonist and antagonistic muscles to various levels, measured using electromyography (EMG). An Artificial Neural Network …
Impoved Hardware Design Of Iot Prosthetic Device, Yu Wang, Warren Hunter, Xiaolin Chen, Housney Ahmed, Haneefah Safo
Impoved Hardware Design Of Iot Prosthetic Device, Yu Wang, Warren Hunter, Xiaolin Chen, Housney Ahmed, Haneefah Safo
Publications and Research
Our previous IoT based prosthetic arm prototype used servo motors to control finger movement through an Arduino Mega, which is connected to the muscle, pulse, and temperature sensors. The Arduino Mega was also connected to a Raspberry Pi 3 model B to transfer data from/to an online web application. One major limitation encountered during testing this prosthetic device was the space occupied by these components, which makes the device bulky. In addition, these servo motors cannot control the movement of the prosthetic device precisely. In this paper, we propose to improve on the existing prosthetic limb prototype by transitioning the …
Microfluidic Electrical Impedance Spectroscopy, John J. Foley
Microfluidic Electrical Impedance Spectroscopy, John J. Foley
Master's Theses
The goal of this study is to design and manufacture a microfluidic device capable of measuring changes in impedance valuesof microfluidic cell cultures. Tocharacterize this, an interdigitated array of electrodes was patterned over glass, where it was then bonded to a series of fluidic networks created in PDMS via soft lithography. The device measured ethanol impedance initially to show that values remain consistent over time. Impedance values of water and 1% wt. saltwater were compared to show that the device is able to detect changes in impedance, with up to a 60% reduction in electrical impedance in saltwater. Cells were …