Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons™

Open Access. Powered by Scholars. Published by Universities.®

Articles 61 - 90 of 104

Full-Text Articles in Biomedical Engineering and Bioengineering

Thermomagnetic-Responsive Self-Folding Microgrippers For Improving Minimally Invasive Surgical Techniques And Biopsies, Caleigh R. Dunn, Bruce Lee, Rupak Rajachar Aug 2022

Thermomagnetic-Responsive Self-Folding Microgrippers For Improving Minimally Invasive Surgical Techniques And Biopsies, Caleigh R. Dunn, Bruce Lee, Rupak Rajachar

Michigan Tech Publications, Part 1

Traditional open surgery complications are typically due to trauma caused by accessing the procedural site rather than the procedure itself. Minimally invasive surgery allows for fewer complications as microdevices operate through small incisions or natural orifices. However, current minimally invasive tools typically have restricted maneuverability, accessibility, and positional control of microdevices. Thermomagnetic-responsive microgrippers are microscopic multi-fingered devices that respond to temperature changes due to the presence of thermal-responsive polymers. Polymeric devices, made of poly(N-isopropylacrylamide-co-acrylic acid) (pNIPAM-AAc) and polypropylene fumarate (PPF), self-fold due to swelling and contracting of the hydrogel layer. In comparison, soft metallic devices feature a pre-stressed metal bilayer …


Antimicrobial Mechanisms Of Biomaterials: From Macro To Nano, Shounak Roy, Sanchita Sarkhel, Deepali Bisht, Samerender Nagam Hanumantharao, Smitha Rao, Amit Jaiswal Jun 2022

Antimicrobial Mechanisms Of Biomaterials: From Macro To Nano, Shounak Roy, Sanchita Sarkhel, Deepali Bisht, Samerender Nagam Hanumantharao, Smitha Rao, Amit Jaiswal

Michigan Tech Publications, Part 1

Overcoming the global concern of antibiotic resistance is one of the biggest challenge faced by scientists today and the key to tackle this issue of emerging infectious diseases is the development of next-generation antimicrobials. The rapid emergence of multi-drug resistant microbes, superbugs and mutated strains of viruses have fueled the search for new and alternate antimicrobial agents with broad-spectrum biocidal activity. Biomaterials, ranging from macroscopic polymers, proteins, and peptides to nanoscale materials such as nanoparticles, nanotubes and nanosheets have emerged as effective antimicrobials. An extensive body of research has established the antibacterial and antiviral efficiencies of different types of biomaterials. …


Comparison Of Performance Of Self-Expanding And Balloon-Expandable Transcatheter Aortic Valves, Hoda Hatoum, Milad Samaee, Janarthanan Sathananthan, Stephanie Sellers, Maximilian Kuetting, Scott M. Lilly, Abdul R. Ihdayhid, Philipp Blanke, Jonathon Leipsic, Vinod H. Thourani, Lakshmi Prasad Dasi Jun 2022

Comparison Of Performance Of Self-Expanding And Balloon-Expandable Transcatheter Aortic Valves, Hoda Hatoum, Milad Samaee, Janarthanan Sathananthan, Stephanie Sellers, Maximilian Kuetting, Scott M. Lilly, Abdul R. Ihdayhid, Philipp Blanke, Jonathon Leipsic, Vinod H. Thourani, Lakshmi Prasad Dasi

Michigan Tech Publications, Part 1

Objective: To evaluate the flow dynamics of self-expanding and balloon-expandable transcatheter aortic valves pertaining to turbulence and pressure recovery. Transcatheter aortic valves are characterized by different designs that have different valve performance and outcomes. Methods: Assessment of transcatheter aortic valves was performed using self-expanding devices (26-mm Evolut [Medtronic], 23-mm Allegra [New Valve Technologies], and small Acurate neo [Boston Scientific]) and a balloon-expandable device (23-mm Sapien 3 [Edwards Lifesciences]). Particle image velocimetry assessed the flow downstream. A Millar catheter was used for pressure recovery calculation. Velocity, Reynolds shear stresses, viscous shear stress, and pressure gradients were calculated. Results: The maximal velocity …


Overcoming Supply Disruptions During Pandemics By Utilizing Found Hardware For Open Source Gentle Ventilation, S. Oberloier, N. Gallup, J. M. Pearce Apr 2022

Overcoming Supply Disruptions During Pandemics By Utilizing Found Hardware For Open Source Gentle Ventilation, S. Oberloier, N. Gallup, J. M. Pearce

Michigan Tech Publications, Part 1

This article details the design of an open source emergency gentle ventilator (gentle-vent) framework that can be used in periods of scarcity. Although it is not a medical device, the system utilizes a wide range of commonly-available components that are combined using basic electronics skills to achieve the desired performance. The main function of the gentle-vent is to generate a calibrated pressure wave at the pump to provide support to the patient's breathing. Each gentle-vent permutation was tested using a DIY manometer as it would be utilized in the field in low-resource settings and validated with an open source VentMon. …


Gradient And Pressure Recovery Of A Self-Expandable Transcatheter Aortic Valve Depends On Ascending Aorta Size: In Vitro Study, Milad Samaee, Hoda Hatoum, Michael Biersmith, Breandan Yeats, Shelley C. Gooden, Vinod H. Thourani, Rebecca T. Hahn, Scott Lilly, Ajit Yoganathan, Lakshmi Prasad Dasi Mar 2022

Gradient And Pressure Recovery Of A Self-Expandable Transcatheter Aortic Valve Depends On Ascending Aorta Size: In Vitro Study, Milad Samaee, Hoda Hatoum, Michael Biersmith, Breandan Yeats, Shelley C. Gooden, Vinod H. Thourani, Rebecca T. Hahn, Scott Lilly, Ajit Yoganathan, Lakshmi Prasad Dasi

Michigan Tech Publications, Part 1

Objective: In this study we aimed to understand the role of interaction of the Medtronic Evolut R transcatheter aortic valve with the ascending aorta (AA) by evaluating the performance of the valve and the pressure recovery in different AA diameters with the same aortic annulus size. Methods: A 26-mm Medtronic Evolut R valve was tested using a left heart simulator in aortic root models of different AA diameter (D): small (D = 23 mm), medium (D = 28 mm), and large (D = 34 mm) under physiological conditions. Measurements of pressure from upstream to downstream of the valve were performed …


Novel Stimuli-Responsive Pectin-Pvp-Functionalized Clay Based Smart Hydrogels For Drug Delivery And Controlled Release Application, Shabnam Rehmat, Nayab Batool Rizvi, Saba Urooge Khan, Abdul Ghaffar, Atif Islam, Rafi Ullah Khan, Azra Mehmood, Hira Butt, Muhammad Rizwan Feb 2022

Novel Stimuli-Responsive Pectin-Pvp-Functionalized Clay Based Smart Hydrogels For Drug Delivery And Controlled Release Application, Shabnam Rehmat, Nayab Batool Rizvi, Saba Urooge Khan, Abdul Ghaffar, Atif Islam, Rafi Ullah Khan, Azra Mehmood, Hira Butt, Muhammad Rizwan

Michigan Tech Publications, Part 1

Stimuli-responsive drug delivery systems are urgently required for injectable site-specific delivery and release of drugs in a controlled manner. For this purpose, we developed novel pH-sensitive, biodegradable, and antimicrobial hydrogels from bio-macromolecule pectin, polyvinylpyrrolidone (PVP), 3-aminopropyl (diethoxy)methyl silane (3-APDEMS), and sepiolite clay via blending and solution casting technique. The purified sepiolite (40 um) was functionalized with 3-APDEMS crosslinker (ex-situ modification) followed by hydrogels fabrication. FTIR and SEM confirmed crosslinked structural integrity and rod-like morphology of hydrogels respectively. The swelling properties of hydrogels could be controlled by varying the concentration of modified clay in pectin/PVP blends. Moreover, the decrease in pH …


Graphene Oxide Functionalized Biosensor For Detection Of Stress-Related Biomarkers, Erican Santiago, Shailu Shree Poudyal, Sung Y. Shin, Hyeun Joong Yoon Jan 2022

Graphene Oxide Functionalized Biosensor For Detection Of Stress-Related Biomarkers, Erican Santiago, Shailu Shree Poudyal, Sung Y. Shin, Hyeun Joong Yoon

Michigan Tech Publications, Part 1

A graphene oxide (GO)-based cortisol biosensor was developed to accurately detect corti-sol concentrations from sweat samples at point-of-care (POC) sites. A reference electrode, counter electrode, and working electrode make up the biosensor, and the working electrode was functional-ized using multiple layers consisting of GO and antibodies, including Protein A, IgG, and anti-Cab. Sweat samples contact the anti-Cab antibodies to transport electrons to the electrode, resulting in an electrochemical current response. The sensor was tested at each additional functionalization layer and at cortisol concentrations between 0.1 and 150 ng/mL to determine how the current response differed. A potentiostat galvanostat device was …


Stress Corrosion Analysis And Direct Cell Viability Of Biodegradable Zn-Fe-Ca Alloy In In-Vitro Conditions, Orit Avior, Noa Ben Ghedalia-Peled, Tomer Ron, Jeremy Goldman, Razi Vago, Eli Aghion Jan 2022

Stress Corrosion Analysis And Direct Cell Viability Of Biodegradable Zn-Fe-Ca Alloy In In-Vitro Conditions, Orit Avior, Noa Ben Ghedalia-Peled, Tomer Ron, Jeremy Goldman, Razi Vago, Eli Aghion

Michigan Tech Publications, Part 1

Due to the excellent biocompatibility of Zn and Zn-based alloys, researchers have shown great interest in developing biodegradable implants based on zinc. Furthermore, zinc is an essential component of many enzymes and proteins. The human body requires ~15 mg of Zn per day, and there is minimal concern for systemic toxicity from a small zinc-based cardiovascular implant, such as an arterial stent. However, biodegradable Zn-based implants have been shown to provoke local fibrous encapsulation reactions that may isolate the implant from its surrounding environment and interfere with implant function. The development of biodegradable implants made from Zn-Fe-Ca alloy was designed …


Patient-Specific Cardiovascular Superelastic Niti Stents Produced By Laser Powder Bed Fusion, Valentina Finazzi, Francesca Berti, Roger J. Guillory Ii, Lorenza Petrini, Barbara Previtali, Ali Gökhan Demir Jan 2022

Patient-Specific Cardiovascular Superelastic Niti Stents Produced By Laser Powder Bed Fusion, Valentina Finazzi, Francesca Berti, Roger J. Guillory Ii, Lorenza Petrini, Barbara Previtali, Ali Gökhan Demir

Michigan Tech Publications, Part 1

To date, there is a general lack of customizability within the selection of endovascular devices for catheter-based vascular interventions. Laser powder bed fusion (LPBF) has been flexibly exploited to produce customized implants using conventional biomedical alloys for orthopedic and dental applications. Applying LPBF for cardiovascular applications, patient-specific stents can be produced with small struts (approximately 100-300 µm), variable geometries, and clinically used metals capable of superelastic behaviour at body temperature (eg. equiatomic nickel-titanium alloys, NiTi). Additionally, the growing availability and use of patient-specific 3D models provides a unique opportunity to outline the necessary manufacturing process that would be required for …


Bioabsorbable Metal Zinc Differentially Affects Mitochondria In Vascular Endothelial And Smooth Muscle Cells, Olivia R. M. Bagshaw, Fereshteh Moradi, Christopher S. Moffatt, Hillary A. Hettwer, Ping Liang, Jeremy Goldman, Jaroslaw Drelich, Jeffrey A. Stuart Dec 2021

Bioabsorbable Metal Zinc Differentially Affects Mitochondria In Vascular Endothelial And Smooth Muscle Cells, Olivia R. M. Bagshaw, Fereshteh Moradi, Christopher S. Moffatt, Hillary A. Hettwer, Ping Liang, Jeremy Goldman, Jaroslaw Drelich, Jeffrey A. Stuart

Michigan Tech Publications, Part 1

Zinc is an essential trace element having various structural, catalytic and regulatory interactions with an estimated 3000 proteins. Zinc has drawn recent attention for its use, both as pure metal and alloyed, in arterial stents due to its biodegradability, biocompatibility, and low corrosion rates. Previous studies have demonstrated that zinc metal implants prevent the development of neointimal hyperplasia, which is a common cause of restenosis following coronary intervention. This suppression appears to be smooth muscle cell-specific, as reendothelization of the neointima is not inhibited. To better understand the basis of zinc's differential effects on rat aortic smooth muscle (RASMC) versus …


3d Printing In Cardiology: A Review Of Applications And Roles For Advanced Cardiac Imaging, Ellen M. Lindquist, Jordan M. Gosnell, Sana K. Khan, John L. Byl, Weihua Zhou, Jingfeng Jiang, Et. Al. Dec 2021

3d Printing In Cardiology: A Review Of Applications And Roles For Advanced Cardiac Imaging, Ellen M. Lindquist, Jordan M. Gosnell, Sana K. Khan, John L. Byl, Weihua Zhou, Jingfeng Jiang, Et. Al.

Michigan Tech Publications, Part 1

With the rate of cardiovascular diseases in the U.S increasing throughout the years, there is a need for developing more advanced treatment plans that can be tailored to specific patients and scenarios. The development of 3D printing is rapidly gaining acceptance into clinical cardiology.

In this review, key technologies used in 3D printing are briefly summarized, particularly, the use of artificial intelligence (AI), open-source tools like MeshLab and MeshMixer, and 3D printing techniques such as fused deposition molding (FDM) and polyjet are reviewed. The combination of 3D printing, multiple image integration, and augmented reality may greatly enhance data visualization …


Hepatic Cell Mobilization For Protection Against Ischemic Myocardial Injury, Shu Q. Liu, John B. Troy, Chi Hao Luan, Roger J. Guillory Ii Aug 2021

Hepatic Cell Mobilization For Protection Against Ischemic Myocardial Injury, Shu Q. Liu, John B. Troy, Chi Hao Luan, Roger J. Guillory Ii

Michigan Tech Publications, Part 1

The heart is capable of activating protective mechanisms in response to ischemic injury to support myocardial survival and performance. These mechanisms have been recognized primarily in the ischemic heart, involving paracrine signaling processes. Here, we report a distant cardioprotective mechanism involving hepatic cell mobilization to the ischemic myocardium in response to experimental myocardial ischemia–reperfusion (MI-R) injury. A parabiotic mouse model was generated by surgical skin-union of two mice and used to induce bilateral MI-R injury with unilateral hepatectomy, establishing concurrent gain- and loss-of-hepatic cell mobilization conditions. Hepatic cells, identified based on the cell-specific expression of enhanced YFP, were found in …


Electroactive Polymeric Composites To Mimic The Electromechanical Properties Of Myocardium In Cardiac Tissue Repair, Kaylee Meyers, Bruce Lee, Rupak Rajachar May 2021

Electroactive Polymeric Composites To Mimic The Electromechanical Properties Of Myocardium In Cardiac Tissue Repair, Kaylee Meyers, Bruce Lee, Rupak Rajachar

Michigan Tech Publications, Part 1

Due to the limited regenerative capabilities of cardiomyocytes, incidents of myocardial infarction can cause permanent damage to native myocardium through the formation of acellular, non-conductive scar tissue during wound repair. The generation of scar tissue in the myocardium compromises the biomechanical and electrical properties of the heart which can lead to further cardiac problems including heart failure. Currently, patients suffering from cardiac failure due to scarring undergo transplantation but limited donor availability and complications (i.e., rejection or infectious pathogens) exclude many individuals from successful transplant. Polymeric tissue engineering scaffolds provide an alternative approach to restore normal myocardium structure and function …


Oxidation Chemistry Of Catechol Utilized In Designing Stimuli-Responsive Adhesives And Antipathogenic Biomaterials, Rattapol Pinnataip, Bruce Lee Feb 2021

Oxidation Chemistry Of Catechol Utilized In Designing Stimuli-Responsive Adhesives And Antipathogenic Biomaterials, Rattapol Pinnataip, Bruce Lee

Michigan Tech Publications, Part 1

Mussel foot proteins (Mfps) contain a large amount of the catecholic amino acid, DOPA, allowing the marine organism to anchor themselves onto various surfaces in a turbulent and wet environment. Modification of polymers with catechol imparts these materials with a strong, wet adhesive property. The oxidation chemistry and oxidation state of catechol are critical to the design of synthetic adhesives and biomaterials. In this Mini-Review, the effect of catechol oxidation state on adhesion, oxidation-mediated catechol cross-linking, and the generation of reactive oxygen species (ROS) during catechol oxidation are reviewed. Finally, the tuning of catechol oxidation state in designing stimuli-responsive adhesives …


Analysis Of Human Gait Using Hybrid Eeg-Fnirs-Based Bci System: A Review, Haroon Khan, Noman Naseer, Anis Yazidi, Per Kristian Eide, Hafiz Wajahat Hassan, Peyman Mirtaheri Jan 2021

Analysis Of Human Gait Using Hybrid Eeg-Fnirs-Based Bci System: A Review, Haroon Khan, Noman Naseer, Anis Yazidi, Per Kristian Eide, Hafiz Wajahat Hassan, Peyman Mirtaheri

Michigan Tech Publications, Part 1

Human gait is a complex activity that requires high coordination between the central nervous system, the limb, and the musculoskeletal system. More research is needed to understand the latter coordination's complexity in designing better and more effective rehabilitation strategies for gait disorders. Electroencephalogram (EEG) and functional near-infrared spectroscopy (fNIRS) are among the most used technologies for monitoring brain activities due to portability, non-invasiveness, and relatively low cost compared to others. Fusing EEG and fNIRS is a well-known and established methodology proven to enhance brain–computer interface (BCI) performance in terms of classification accuracy, number of control commands, and response time. Although …


Catechol-Based Antimicrobial Polymers, Seyedehfatemeh Razaviamri, Kan Wang, Bo Liu, Bruce P. Lee Jan 2021

Catechol-Based Antimicrobial Polymers, Seyedehfatemeh Razaviamri, Kan Wang, Bo Liu, Bruce P. Lee

Michigan Tech Publications, Part 1

Catechol is a key constituent in mussel adhesive proteins and is responsible for strong adhesive property and crosslinking formation. Plant-based polyphenols are also capable of chemical interactions similar to those of catechol and are inherently antimicrobial. This review reports a series of catechol-based antimicrobial polymers classified according to their antimicrobial mechanisms. Catechol is utilized as a surface anchoring group for adhering monomers and polymers of known antimicrobial properties onto various types of surfaces. Additionally, catechol's ability to form strong complexes with metal ions and nanoparticles was utilized to sequester these antimicrobial agents into coatings and polymer matrices. During catechol oxidation, …


The Economics Of Classroom 3-D Printing Of Open-Source Digital Designs Of Learning Aids, Nicole Gallup, Joshua M. Pearce Nov 2020

The Economics Of Classroom 3-D Printing Of Open-Source Digital Designs Of Learning Aids, Nicole Gallup, Joshua M. Pearce

Michigan Tech Publications, Part 1

While schools struggle financially, capital for purchasing physical learning aids is often cut. To determine if costs could be reduced for learning aids, this study analyzed classroom-based distributed digital manufacturing using 3-D printing of open-source learning aid designs. Learning aid designs are analyzed in detail for their economic viability considering printing and assembly costs with purchased components and compared to equivalent or inferior commercial products available on Amazon. The results show current open-source 3-D printers are capable of manufacturing useful learning aids and that doing so provides high economic savings in the classroom. Overall, the average learning aid would save …


Partially Reprapable Automated Open Source Bag Valve Mask-Based Ventilator, Aliaksei Petsiuk, Nagendra G. Tanikella, Samantha Dertinger, Adam Pringle, Shane Oberloier, Joshua M. Pearce Oct 2020

Partially Reprapable Automated Open Source Bag Valve Mask-Based Ventilator, Aliaksei Petsiuk, Nagendra G. Tanikella, Samantha Dertinger, Adam Pringle, Shane Oberloier, Joshua M. Pearce

Michigan Tech Publications, Part 1

This study describes the development of a simple and easy-to-build portable automated bag valve mask (BVM) compression system, which, during acute shortages and supply chain disruptions can serve as a temporary emergency ventilator. The resuscitation system is based on the Arduino controller with a real-time operating system installed on a largely RepRap 3-D printable parametric component-based structure. The cost of the materials for the system is under $170, which makes it affordable for replication by makers around the world. The device provides a controlled breathing mode with tidal volumes from 100 to 800 mL, breathing rates from 5 to 40 …


Parametric Nasopharyngeal Swab For Sampling Covid-19 And Other Respiratory Viruses: Open Source Design, Sla 3-D Printing And Uv Curing System, Nicole Gallup, Adam M. Pringle, Shane Oberloier, Nagendra G. Tanikella, Joshua M. Pearce Oct 2020

Parametric Nasopharyngeal Swab For Sampling Covid-19 And Other Respiratory Viruses: Open Source Design, Sla 3-D Printing And Uv Curing System, Nicole Gallup, Adam M. Pringle, Shane Oberloier, Nagendra G. Tanikella, Joshua M. Pearce

Michigan Tech Publications, Part 1

Access to nasopharyngeal swabs for sampling remain a bottleneck in some regions for COVID-19 testing. This study develops a distributed manufacturing solution using only an open source manufacturing tool chain consisting of two types of open source 3-D printing and batch UV curing, and provides a parametric fully free design of a nasopharyngeal swab. The swab was designed using parametric OpenSCAD in two components (a head with engineered break point and various handles), which has several advantages: i) minimizing print time on relatively slow SLA printers, ii) enabling the use of smaller print volume open source SLA printers, iii) reducing …


Wireless Technologies For Implantable Devices, Bradley D. Nelson, Salil Sidharthan Karipott, Yvonne Wang, Keat Ghee Ong Aug 2020

Wireless Technologies For Implantable Devices, Bradley D. Nelson, Salil Sidharthan Karipott, Yvonne Wang, Keat Ghee Ong

Michigan Tech Publications, Part 1

Wireless technologies are incorporated in implantable devices since at least the 1950s. With remote data collection and control of implantable devices, these wireless technologies help researchers and clinicians to better understand diseases and to improve medical treatments. Today, wireless technologies are still more commonly used for research, with limited applications in a number of clinical implantable devices. Recent development and standardization of wireless technologies present a good opportunity for their wider use in other types of implantable devices, which will significantly improve the outcomes of many diseases or injuries. This review briefly describes some common wireless technologies and modern advancements, …


Reprapable Automated Open Source Bag Valve Mask-Based Ventilator, Aliaksei Petsiuk, Nagendra Gautam Tanikella, Samantha C. Dertinger, Adam Pringle, Shane Oberloier, Joshua M. Pearce Jun 2020

Reprapable Automated Open Source Bag Valve Mask-Based Ventilator, Aliaksei Petsiuk, Nagendra Gautam Tanikella, Samantha C. Dertinger, Adam Pringle, Shane Oberloier, Joshua M. Pearce

Michigan Tech Publications, Part 1

This study describes the development of an automated bag valve mask (BVM) compression system, which, during acute shortages and supply chain disruptions can serve as a temporary emergency ventilator. The resuscitation system is based on the Arduino controller with a real-time operating system installed on a largely RepRap 3-D printable parametric component-based structure. The cost of the system is under $170, which makes it affordable for replication by makers around the world. The device provides a controlled breathing mode with tidal volumes from 100 to 800 milliliters, breathing rates from 5 to 40 breaths/minute, and inspiratory-to-expiratory ratio from 1:1 to …


Parametric Nasopharyngeal Swab For Sampling Covid-19 And Other Respiratory Viruses: Open Source Design, Sla 3-D Printing And Uv Curing System, Nicole Gallup, Adam Pringle, Shane Oberloier, Nagendra Gautam Tanikella, Joshua M. Pearce May 2020

Parametric Nasopharyngeal Swab For Sampling Covid-19 And Other Respiratory Viruses: Open Source Design, Sla 3-D Printing And Uv Curing System, Nicole Gallup, Adam Pringle, Shane Oberloier, Nagendra Gautam Tanikella, Joshua M. Pearce

Michigan Tech Publications, Part 1

Access to nasopharyngeal swabs for sampling remain a bottleneck in some regions for COVID19 testing. This study develops a distributed manufacturing solution using only an open source manufacturing tool chain consisting of two types of open source 3-D printing and batch UV curing, and provides a parametric fully free design of a nasopharyngeal swab. The swab was designed using parametric OpenSCAD in two components (a head with engineered break point and various handles), which has several advantages: i) minimizing print time on relatively slow SLA printers, ii) enabling the use of smaller print volume open source SLA printers, iii) reducing …


Tra-1-60-Positive/Cd45low Cells Found In The Peripheral Blood Of Prostate Cancer Patients With Metastatic Disease – A Proof-Of-Concept Study, Claudia Schäfer, Yawen Ju, Youngbin Tak, Cesar Vazquez, Sangyoon J. Han, Edwin Tan, Et Al. Jan 2020

Tra-1-60-Positive/Cd45low Cells Found In The Peripheral Blood Of Prostate Cancer Patients With Metastatic Disease – A Proof-Of-Concept Study, Claudia Schäfer, Yawen Ju, Youngbin Tak, Cesar Vazquez, Sangyoon J. Han, Edwin Tan, Et Al.

Michigan Tech Publications, Part 1

Purpose

Over 90% of all cancer related deaths are due to metastasis. However, current diagnostic tools can't reliably discriminate between invasive and localized cancers.

Patients and methods

In this proof-of-concept study, we employed the embryonic stem cell marker TRA-1-60 (TRA+) to identify TRA + cells within the blood of prostate cancer patients and searched for TRA + cells in men with metastatic and localized cancers. We isolated whole peripheral blood mononuclear cells from 26 metastatic prostate cancer patients, from 13 patients with localized prostate cancer and from 17 healthy controls. Cells were stained for DAPI, CD45 and TRA + by …


S-Nitroso-N-Acetyl-D-Penicillamine Modified Hyperbranched Polyamidoamine For High-Capacity Nitric Oxide Storage And Release, Sean Hopkins, Megan C. Frost Jan 2020

S-Nitroso-N-Acetyl-D-Penicillamine Modified Hyperbranched Polyamidoamine For High-Capacity Nitric Oxide Storage And Release, Sean Hopkins, Megan C. Frost

Michigan Tech Publications, Part 1

Synthetic nitric oxide (NO)-donating materials have been shown to have many beneficial effects when incorporated into biomedical materials. When released in the correct dosage, NO has been shown to increase the biocompatibility of blood and tissue contacting materials, but materials are often limited in the amount of NO that can be administered over a period of time. To address this, hyperbranched polyamidoamine (HPAMAM) was modified with the S-nitrosothiol, S-nitroso-N-acetyl-D-penicillamine, and nitrosated to form a controlled, high-capacity NO-donating compound (SNAP-HPAMAM). This compound has the potential of modifying polymers to release NO over long periods of time by being blended into a …


Engineered Three-Dimensional Scaffolds Modulating Fate Of Breast Cancer Cells Using Stiffness And Morphology Related Cell Adhesion, Samerender Nagam Hanumantharao, Carolynn Que, Brennan Vogl, Smitha Rao Jan 2020

Engineered Three-Dimensional Scaffolds Modulating Fate Of Breast Cancer Cells Using Stiffness And Morphology Related Cell Adhesion, Samerender Nagam Hanumantharao, Carolynn Que, Brennan Vogl, Smitha Rao

Michigan Tech Publications, Part 1

Goal: Artificially engineering the tumor microenvironment in vitro as a vital tool for understanding the mechanism of tumor progression. In this study, we developed three-dimensional cell scaffold systems with different topographical features and mechanical properties but similar surface chemistry. The cell behavior was modulated by the topography and mechanical properties of the scaffold. Adenocarcinoma (MCF7), triple-negative (MDA-MB-231) and premalignant (MCF10AneoT) breast cancer cells were seeded on the scaffold systems. The cell viability, cell-cell interaction and cell-matrix interactions were analyzed. The preferential growth and alignment of specific population of cells were demonstrated. Among the different scaffolds, triple-negative breast cancer cells preferred …


Multi-Functional Electrospun Nanofibers From Polymer Blends For Scaffold Tissue Engineering, Samerender Nagam Hanumantharao, Smitha Rao Jul 2019

Multi-Functional Electrospun Nanofibers From Polymer Blends For Scaffold Tissue Engineering, Samerender Nagam Hanumantharao, Smitha Rao

Michigan Tech Publications, Part 1

Electrospinning and polymer blending have been the focus of research and the industry for their versatility, scalability, and potential applications across many different fields. In tissue engineering, nanofiber scaffolds composed of natural fibers, synthetic fibers, or a mixture of both have been reported. This review reports recent advances in polymer blended scaffolds for tissue engineering and the fabrication of functional scaffolds by electrospinning. A brief theory of electrospinning and the general setup as well as modifications used are presented. Polymer blends, including blends with natural polymers, synthetic polymers, mixture of natural and synthetic polymers, and nanofiller systems, are discussed in …


Investigative Study On Nitric Oxide Production In Human Dermal Fibroblast Cells Under Normal And High Glucose Conditions, Maria Paula Kwesiga, Emily Cook, Jennifer Hannon, Sarah Wayward, Caroline Gwaltney, Smitha Rao, Megan C. Frost Nov 2018

Investigative Study On Nitric Oxide Production In Human Dermal Fibroblast Cells Under Normal And High Glucose Conditions, Maria Paula Kwesiga, Emily Cook, Jennifer Hannon, Sarah Wayward, Caroline Gwaltney, Smitha Rao, Megan C. Frost

Michigan Tech Publications, Part 1

Diabetic foot ulcers (DFU) are a major health problem associated with diabetes mellitus. Impaired nitric oxide (NO) production has been shown to be a major contributor to the dysregulation of healing in DFU. The level of impairment is not known primarily due to challenges with measuring NO. Herein, we report the actual level of NO produced by human dermal fibroblasts cultured under normal and high glucose conditions. Fibroblasts produce the extracellular matrix, which facilitate the migration of keratinocytes to close wounds. The results show that NO production was significantly higher in normal glucose compared to high glucose conditions. The real-time …


Synthesis And Characterization Of Controlled Nitric Oxide Release From S-Nitroso-N-Acetyl-D-Penicillamine Covalently Linked To Polyvinyl Chloride (Snap-Pvc), Sean Hopkins, Megan C. Frost Sep 2018

Synthesis And Characterization Of Controlled Nitric Oxide Release From S-Nitroso-N-Acetyl-D-Penicillamine Covalently Linked To Polyvinyl Chloride (Snap-Pvc), Sean Hopkins, Megan C. Frost

Michigan Tech Publications, Part 1

Polyvinyl chloride (PVC) is one of the most widely used polymers in medicine but has very poor biocompatibility when in contact with tissue or blood. To increase biocompatibility, controlled release of nitric oxide (NO) can be utilized to mitigate and reduce the inflammatory response. A synthetic route is described where PVC is aminated to a specified degree and then further modified by covalently linking S-nitroso-N-acetyl-d-penicillamine (SNAP) groups to the free primary amine sites to create a nitric oxide releasing polymer (SNAP-PVC). Controllable release of NO from SNAP-PVC is described using photoinitiation from light emitting diodes (LEDs). Ion-mediated NO release is …


The Effect Of Nd On Mechanical Properties And Corrosion Performance Of Biodegradable Mg-5%Zn Alloy, Lilach Elkaiam, Orly Hakimi, Jeremy Goldman, Eli Aghion Jun 2018

The Effect Of Nd On Mechanical Properties And Corrosion Performance Of Biodegradable Mg-5%Zn Alloy, Lilach Elkaiam, Orly Hakimi, Jeremy Goldman, Eli Aghion

Michigan Tech Publications, Part 1

Mg based implants are limited by their poor strength, ductility, and corrosion performance in physiological environments, drawbacks further compounded by their premature loss of mechanical integrity and evolution of harmful hydrogen gas. Neodymium additions to magnesium have been shown to improve mechanical properties through precipitation and solid solution hardening. Therefore, the present study incorporated Nd additions (up to 3%) into a promising Mg-5%Zn-0.13%Y-0.35%Zr alloy to improve mechanical properties and corrosion resistance. The microstructure evaluation of a series of alloys was performed using optical microscopy, scanning electron microscopy (SEM), and X-ray diffraction analysis. The mechanical properties were examined in terms of …


Bioactive Polydimethylsiloxane Surface For Optimal Human Mesenchymal Stem Cell Sheet Culture, Zichen Qian, David Ross, Wenkai Jia, Qi Xing, Feng Zhao Jun 2018

Bioactive Polydimethylsiloxane Surface For Optimal Human Mesenchymal Stem Cell Sheet Culture, Zichen Qian, David Ross, Wenkai Jia, Qi Xing, Feng Zhao

Michigan Tech Publications, Part 1

Human mesenchymal stem cell (hMSC) sheets hold great potential in engineering three-dimensional (3D) completely biological tissues for diverse applications. Conventional cell sheet culturing methods employing thermoresponsive surfaces are cost ineffective, and rely heavily on available facilities. In this study, a cost-effective method of layer-by-layer grafting was utilized for covalently binding a homogenous collagen I layer on a commonly used polydimethylsiloxane (PDMS) substrate surface in order to improve its cell adhesion as well as the uniformity of the resulting hMSC cell sheet. Results showed that a homogenous collagen I layer was obtained via this grafting method, which improved hMSC adhesion and …