Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Biomedical Devices and Instrumentation (98)
- Other Biomedical Engineering and Bioengineering (66)
- Biomechanics and Biotransport (49)
- Molecular, Cellular, and Tissue Engineering (37)
- Bioelectrical and Neuroengineering (32)
-
- Biomaterials (30)
- Electrical and Computer Engineering (25)
- Mechanical Engineering (25)
- Bioimaging and Biomedical Optics (22)
- Life Sciences (21)
- Medicine and Health Sciences (21)
- Biological Engineering (17)
- Biomedical (17)
- Biomechanical Engineering (14)
- Systems and Integrative Engineering (11)
- Physical Sciences and Mathematics (10)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (9)
- Electrical and Electronics (9)
- Materials Science and Engineering (9)
- Computer-Aided Engineering and Design (7)
- Computer Sciences (6)
- Signal Processing (6)
- Social and Behavioral Sciences (6)
- Applied Mechanics (5)
- Biology and Biomimetic Materials (5)
- Civil and Environmental Engineering (5)
- Computer Engineering (5)
- Diseases (5)
- Institution
- Keyword
-
- Biomechanics (13)
- Microfluidics (13)
- Electrospinning (8)
- Ischemia (8)
- Tissue Engineering (8)
-
- Bone (7)
- Endothelial Dysfunction (7)
- Finite Element Analysis (7)
- Gait (7)
- Scaffold (7)
- FEA (6)
- Tissue engineering (6)
- Angiogenesis (5)
- Arteriogenesis (5)
- Blood Vessel Mimic (5)
- Bone Remodeling (5)
- COMSOL (5)
- Electrophysiology (5)
- Microfluidic Device (5)
- Bioreactor (4)
- Blood vessel mimic (4)
- Cartilage (4)
- Cell Culture (4)
- Collateral circulation (4)
- Cycling (4)
- Diabetes (4)
- Engineering (4)
- Hypoxia (4)
- ICD (4)
- Keratinocytes (4)
Articles 271 - 300 of 304
Full-Text Articles in Biomedical Engineering and Bioengineering
Implementation Of Physiologic Pressure Conditions In A Blood Vessel Mimic Bioreactor System, Kevin Mark Okarski
Implementation Of Physiologic Pressure Conditions In A Blood Vessel Mimic Bioreactor System, Kevin Mark Okarski
Master's Theses
ABSTRACT
Implementation of Physiologic Pressure Conditions in a Blood Vessel Mimic Bioreactor System
Kevin Mark Okarski
Tissue engineering has traditionally been pursued as a therapeutic science intended for restoring or replacing diseased or damaged biologic tissues or organs. Cal Poly’s Blood Vessel Mimic Laboratory is developing a novel application of tissue engineering as a tool for the preclinical evaluation of intravascular devices. The blood vessel mimic (BVM) system has been previously used to assess the tissue response to deployed stents, but under non-physiologic conditions. Since then, efforts have been made to improve the vessel and bioreactor’s ability to emulate in …
Frontal Plane Humeral Elevation Effects On The Pullout Strength Of Suture Anchors Used In Rotator Cuff Repair, Peter Joshua Larson
Frontal Plane Humeral Elevation Effects On The Pullout Strength Of Suture Anchors Used In Rotator Cuff Repair, Peter Joshua Larson
Master's Theses
The rotator cuff offers the stabilizing forces necessary for fine arm movement. The most common injury to the rotator cuff is the partial or full thickness tear of the supraspinatus tendon, which attaches the humerus to the scapula on the superior side, due to an acute or chronic injury. These injuries account for more than 4.5 million physician visits per year. Depending on the degree of tear, arthroscopic surgery may be needed to reattach the torn tendon to the humeral head. The current preferred method of surgery involves the insertion of a suture anchor into the humeral head that ties …
Effects Of Reamer-Femoral Component Offset On Cement Mantle Penetration In Hip Resurfacing Arthroplasty, Mark Lloyd Paulick
Effects Of Reamer-Femoral Component Offset On Cement Mantle Penetration In Hip Resurfacing Arthroplasty, Mark Lloyd Paulick
Master's Theses
Hip resurfacing arthroplasty has changed the treatment of end stage arthritis without severe deformity for young, active adults. Presently, there are varying clinical approaches to implant design selection and cementation techniques. The purpose of this project is to determine what amount of reamer-femoral component offset allows for the best cement penetration into the femoral head.
Rapid prototyped femoral component models were produced with reamer femoral component offsets of 0.0 mm, 0.5 mm, and 1.0 mm. After implantation onto models of reamed femoral heads made from high-density open-cell reticulated carbon foam, cement penetration was assessed from cross-sections of the foam-implant unit. …
Finite Element Modeling Of Icd Lead Silicone Soft-Tips, Jose J. Lepe
Finite Element Modeling Of Icd Lead Silicone Soft-Tips, Jose J. Lepe
Master's Theses
Although highly underutilized by the medical device industry, Finite Element Analysis (FEA) in the development of new technologies is gaining popularity as regulatory bodies such as the Food and Drug Administration (FDA) begin to require additional proof of safety through scientific methods. Non-linear FEA allows engineers to realistically simulate the mechanical behavior of implants as seen in the in-vitro, or in some cases, the in-vivo configurations. The work presented in this report investigates how computational methods can be used to simulate the interaction of a St. Jude Medical silicone soft-tip as it passes through a Peel-Away Sheath (i.e. introducer). In …
Modeling The Long Term Effects Of Alendronate On Bone Mass Preservation Of The Femur With Articular Surface And Total Hip Replacements, Trevor J. Hryce
Modeling The Long Term Effects Of Alendronate On Bone Mass Preservation Of The Femur With Articular Surface And Total Hip Replacements, Trevor J. Hryce
Master's Theses
Calculating femoral bone density changes after hip arthroplasty is of interest to researchers and clinicians for predicting the longevity of the prosthetic implant and the surrounding bone. Recently clinicians have been administering bisphosphonate drugs in an attempt to reduce the bone resorption due to stress shielding caused by these implants. Current strain-adaptive computational models with bisphosphonate treatment don’t predict the long term effects or look at treatment with hip resurfacing implants. The main goal of this study was to create and validate a computer model of the human femur incorporating a bone remodeling algorithm based on biological remodeling processes and …
Finite Element Analysis And Modeling Of A .38 Lead Round Nose Ballistic Gelatin Test, Danielle Datoc
Finite Element Analysis And Modeling Of A .38 Lead Round Nose Ballistic Gelatin Test, Danielle Datoc
Master's Theses
Firearms are present in two-thirds of United States households. As of 2003, roughly 500,000 projectile wounds occur annually in the United States. This costs an estimated 2.3 billion dollars of medical spending. The best treatment of gunshot wounds relies heavily on experience, but even with experience the unpredictable nature of ballistics can make treatment difficult.
Wound ballistics studies the injury pattern of a particular bullet. Ballistic gelatin tests are used to analyze this pattern. A block of 10 or 20% ballistic gelatin is set and a bullet is fired through the block. Key characteristics of the wound profile seen in …
An Investigative Study Into The Relationship Of Bone Morphogenetic Protein Antagonist Expression And Osteocyte Density By Region And Quadrant, Scott C. Mosher
An Investigative Study Into The Relationship Of Bone Morphogenetic Protein Antagonist Expression And Osteocyte Density By Region And Quadrant, Scott C. Mosher
Master's Theses
The role of cytokines and cell behavior and viability with respect to bone remodeling and bone behavior is an exciting area of orthopedic research. The purpose of this study was to investigate the relationships between BMP antagonist expression and osteocyte density, lacunar densities and osteocyte viability in cortical bone. Samples of unloaded tibial bone obtained from six C57Bl/6 mice were immunohistochemically stained for gremlin and noggin expression and also underwent methyl green staining to determine osteocyte presence. Bone sections were divided into four quadrants (cranial, caudal, medial and lateral) and three regions (proximal, mid shaft and distal), followed by analysis …
Biomechanical Comparison Of Wire Circlage And Rigid Plate Fixation For Median Sternotomy Closure In Human Cadaver Specimens, Mark Steven Wong
Biomechanical Comparison Of Wire Circlage And Rigid Plate Fixation For Median Sternotomy Closure In Human Cadaver Specimens, Mark Steven Wong
Master's Theses
Background:
Over 700,000 patients per year undergo open-heart surgery. Healing complication rates can be up to 5% of patients who undergo this procedure, with a morbidity rate of 50% if mediastinitis supervenes. A secure and rigid fixation of surgically divided sternum is critical to avoid healing complications. The purpose of this study was to compare the yield load, construct stiffness, ultimate load, displacement at ultimate load, and post-yield behavior of three sternotomy closure methods (Peristernal wires or Sternalock titanium plates) when stressed in each of three directions: lateral distraction, rostro-caudal (longitudinal) shear distraction, and anterior-posterior (transverse) shear in a cadaveric …
St Monitoring On The Programmer For Implantable Cardioverter Devices, Sarina Satya
St Monitoring On The Programmer For Implantable Cardioverter Devices, Sarina Satya
Master's Theses
Cardiovascular disease is one of the most prevalent causes of death which has a high mortality rate. If identified early and treated appropriately, the mortality in patients with cardiovascular disease can be hugely reduced. For several decades, 12-Lead ECG has been the standard technique used to identify ischemia, and recent studies have shown that intracardiac electrogram has many benefits over external monitoring such as holter. ST Monitoring feature has been added to St. Jude Medical intracardiac cardioverter defibrillators (ICD) to leverage the ECG technology for identifying cardiovascular disease. This algorithm monitors the intracardiac electrogram to detect and report patterns which …
An Investigation Of Humeral Stress Fractures In Racing Thoroughbreds Using A 3d Finite Element Model In Conjunction With A Bone Remodeling Algorithm, Ryan James Moore
An Investigation Of Humeral Stress Fractures In Racing Thoroughbreds Using A 3d Finite Element Model In Conjunction With A Bone Remodeling Algorithm, Ryan James Moore
Master's Theses
The humerus of a racing horse Thoroughbred is highly susceptible to stress fractures at a characteristic location as a result of cyclic loading. The propensity of a Thoroughbred to exhibit humeral fracture has made equines useful models in the epidemiology of stress fractures. In this study, a racing Thoroughbred humerus was simulated during training using a 3D finite element model in conjunction with a bone remodeling algorithm. Nine muscle forces and two contact forces were applied to the 3-dimensional finite element model, which contains four separate load cases representing fore-stance, mid-stance, aft-stance, and standing. Four different training programs were incorporated …
Merlin.Net Automation Of External Reports Verification Process, Gabriel John Wettlaufer
Merlin.Net Automation Of External Reports Verification Process, Gabriel John Wettlaufer
Master's Theses
Merlin.net Patient Care Network is a St. Jude Medical product that is used for remote patient management. The basic concept of Merlin.net is to allow the physician to view patient device follow-up information as well as general patient and device information on a web application. The Merlin.net system also interfaces with the patient and will send them notification if they miss a follow-up. All device information will be collected automatically while the patient is sleeping. This information is sent through a telephone line to a Merlin.net server to process a report package and display the collected information on the Merlin.net …
Implementation Of Risk Management In The Medical Device Industry, Rachelo Dumbrique
Implementation Of Risk Management In The Medical Device Industry, Rachelo Dumbrique
Master's Theses
This study looks at the implementation and effectiveness of risk management (RM) activities in the medical device industry. An online survey was distributed to medical device professionals who were asked to identify RM-related activities performed during the device life cycle. RM activities and techniques included Establishing Risk Acceptance Criteria, Hazard Identification, Human Factors/Usability, Fault Tree Analysis (FTA), Design Failure Mode and Effects Analysis (DFMEA), Process Failure Mode and Effects Analysis (PFMEA), Hazard and Operability Study (HAZOP), Hazard Analysis and Critical Control Point (HACCP), Risk Benefit Analysis, and Risk Assessment of Customer Complaint. Devices were identified by type (therapeutic, surgical/clinical tools, …
Single Cell Impedance Measurements Using Microfabricated Electrodes And Labview Graphical Programming, Stephanie Sophia Hernandez
Single Cell Impedance Measurements Using Microfabricated Electrodes And Labview Graphical Programming, Stephanie Sophia Hernandez
Master's Theses
This Master’s Thesis project consists of the research, design, and fabrication of a system that could perform broadband impedance measurements (1kHz-20Mhz) of single cells using National Instruments Labview data acquisition and programming in coordination with a single cell capture device. Presented first is the background information on cells and their electrical properties, along with background in micro-total-analysis systems as well as impedance spectroscopy. Experimental Methods are then discussed for the electrode design, cellular modeling in COMSOL, fabrication methods, and Labview 8.0 Set-up and programming. Measurements were performed using the single-cell capture device on saline, yeast cells, and a polysterene bead. …
Laser Scanning Confocal Microscopy (Lscm): An Application For The Detection Of Morphological Alterations In Skin Structure, Shea C. Smith
Laser Scanning Confocal Microscopy (Lscm): An Application For The Detection Of Morphological Alterations In Skin Structure, Shea C. Smith
Master's Theses
Laser scanning confocal microscopy (LSCM) is an optical imaging technique that provides improved resolution and sensitivity over conventional methods of optical microscopy. However, the cost of most commercial LSCM systems exceeds the financial limitations of many smaller laboratories. The design of a custom LSCM created at a fraction of the cost of a commercial model is discussed in this paper.
The increase in the incidence rate of skin cancer in the world today is alarming, as such, it is essential to provide an early, rapid and effective method for in vivo diagnostics of human skin tissue. LSCM is capable of …
The Electrical Properties Of Human Tissue For The Diagnosis And Treatment Of Melanoma Skin Cancer, Glenn Cameron Stante
The Electrical Properties Of Human Tissue For The Diagnosis And Treatment Of Melanoma Skin Cancer, Glenn Cameron Stante
Master's Theses
This thesis discusses the research, experimental methods, and data gathered for the investigation of a novel method for the diagnosis of melanoma skin cancer. First, a background about human skin tissue is presented. Then, a detailed description of melanoma along with current diagnosis techniques and treatment options are presented. In the experimental methods, the electrical properties of several types of tissue were analyzed, the purpose of which was to discover if a tissue type can be distinguished by its electrical properties alone. This would allow for the diagnosis of melanoma to be done by examining the electrical properties of the …
A Computational Model Of Apoptotic Osteocyte Correlation To Cortical Bone Remodeling Parameters, Michael Stephen Alexander
A Computational Model Of Apoptotic Osteocyte Correlation To Cortical Bone Remodeling Parameters, Michael Stephen Alexander
Master's Theses
The onset of osteoporosis caused by aging, disease states, and post-menopausal conditions significantly impacts patient quality of life, required healthcare funding, personal autonomy losses from increased fracture risk and the subsequent corrective surgery. Research has indicated that osteocyte apoptosis may be a key parameter in bone remodeling, raising the possibility of remodeling rate modulation for the mitigation of bone mass resorption. By developing therapies that target osteocyte apoptosis, it may be possible to prevent undesired bone remodeling activity while maintaining a healthy balance between damage formation in the form of microcracks induced by the strain environment and the removal of …
A Rapid Prototyping Method For Constructing A Complex Three-Dimensional Substrate, Kathryn Jacoba Hart
A Rapid Prototyping Method For Constructing A Complex Three-Dimensional Substrate, Kathryn Jacoba Hart
Master's Theses
Cell culturing on three-dimensional structures has increased the possibilities in tissue engineering and bioreactor research. These structures enable cells to differentiate, proliferate, mobilize, and function in a conformation that more accurately mimics in vivo conditions. Computer generated models aid in development and rapid alteration of three-dimensional cell substrates, defining their internal structure as well as their external morphology. The rapid transition from substrate design to a viable culture is imperative to quickly advance research in biomedical and tissue engineering applications.
The aim of this thesis is to investigate the feasibility of a rapid prototyping process by selectively cross-linking and assembling …
Regression Analysis Of Fracture Toughness For Secondary Osteons Located In Human Cortical Bone, Chase A. Fetzer
Regression Analysis Of Fracture Toughness For Secondary Osteons Located In Human Cortical Bone, Chase A. Fetzer
Master's Theses
An experiment was carried out in order to locate and quantify osteon types within a sample of cortical bone taken from a human tibia. This was done using a microscope-camera assembly and the BioQuant computer software. The results of this were correlated with a previous experiment’s results on fracture toughness so that an analysis could be run on the data in order to determine the factors that most affect the value of fracture toughness of this cortical bone. Results were examined closely and the analysis repeated until the author was satisfied that the best possible model for fracture toughness had …
A Pdms Sample Pretreatment Device For The Optimization Of Electrokinetic Manipulations Of Blood Serum, Timothy J. Abram
A Pdms Sample Pretreatment Device For The Optimization Of Electrokinetic Manipulations Of Blood Serum, Timothy J. Abram
Master's Theses
This project encompasses the design of a pretreatment protocol for blood serum and adaption of that protocol to a microfluidic environment in order to optimize key sample characteristics, namely pH, conductivity, and viscosity, to enable on-chip electrokinetic separations. The two major parts of this project include (1) designing a pretreatment protocol to optimize key parameters of the sample solution within a target range and (2) designing /fabricating a microchip that will effectively combine the sample solution with the appropriate buffers to replicate the same bench-scale protocol on the micro-scale.
Biomarker detection in complex samples such as blood necessitates appropriate sample …
Assessment Of Electrospinning As An In-House Fabrication Technique For Blood Vessel Mimic Cellular Scaffolding, Colby M. James
Assessment Of Electrospinning As An In-House Fabrication Technique For Blood Vessel Mimic Cellular Scaffolding, Colby M. James
Master's Theses
Intravascular devices, such as stents, must be rigorously tested before they can be approved by the FDA. This includes bench top in vitro testing to determine biocompatibility, and animal model testing to ensure safety and efficacy. As an intermediate step, a blood vessel mimic (BVM) testing method has been developed that mimics the three dimensional structure of blood vessels using a perfusion bioreactor system, human derived endothelial cells, and a biocompatible polymer scaffold used to support growth of the blood vessel cells. The focus of this thesis was to find an in-house fabrication method capable of making cellular scaffolding for …
The Effect Of Particle Surface Area To Volume Ratio On Ion Release From Cocr Spheres, Darin J. Grandfield
The Effect Of Particle Surface Area To Volume Ratio On Ion Release From Cocr Spheres, Darin J. Grandfield
Master's Theses
In 2005, over 200,000 Americans underwent a hip arthroplasty, the replacement of a hip joint with an artificial prosthesis. Of these arthroplasties, metal-on-metal type implants represent an increasing usage percentage. Metal-on-metal implants are selected largely for their low volumetric wear rate, durability, and resistance to corrosion. In spite of these advantages, little is known concerning the long-term consequences of heavy metal alloy use in the body, although early research indicates potentially carcinogenic results. This thesis is a preliminary investigation into these long term effects and their root causes.
An improved comprehension of the corrosion kinetics and the rate of ion …
Evaluating The Electrical Response Of Polyaniline To Mechanical Strain, Matthew L. Goebel
Evaluating The Electrical Response Of Polyaniline To Mechanical Strain, Matthew L. Goebel
Master's Theses
This thesis focuses on the electrical output of polyaniline films subjected to uniaxial strain in hydrochloric acid solutions. Polyaniline belongs to novel class of materials known as conducting polymers. Alternating single and double bonds in the backbone of conducting polymers allow them to transmit electric charge when they are doped with negatively charged ions. Modifying the degree of doping and other electrical/chemical treatments allow conducting polymers to exhibit conducting, semi-conducting, or insulating electrical properties. Resilient mechanical properties, good processability, and low cost make conducting polymers good candidates for applications traditionally held by metals and semi-conductors.
When tensile strain is applied …
Preparation For Nerve Membrane Potential Readings Of A Leech, Laboratory Setup And Dissection Process, Jason Patrick Caulfield
Preparation For Nerve Membrane Potential Readings Of A Leech, Laboratory Setup And Dissection Process, Jason Patrick Caulfield
Master's Theses
A well documented laboratory setup, leech preparation process, and bio-potential data recording process are needed. Repeatability and quality data recordings are essential and thus dictate the requirements of the laboratory setup and processes listed above. Advances in technology have both helped and hindered this development. While very precise equipment is required to record the low voltage bio-potentials, noisy electronic equipment and wires surrounding the work area provide high levels of interference. Proper laboratory setup and data recording processes, however, limit the unwanted interference. Quality data can only be recorded from a properly handled and prepared leech subject. Proper setup and …
Do Canines Experience The Effects Of Heart Rate Turbulence?, Melanie Ann Gurunathan
Do Canines Experience The Effects Of Heart Rate Turbulence?, Melanie Ann Gurunathan
Master's Theses
Background
The canine cardiac system has been the model against which many Class III cardiac devices are validated. Thus, it is expected that the canine heart has very similar electrical model to that found in humans. In 1999, the absence of Heart Rate Turbulence (HRT) after a single Pre-Ventricular Contraction (PVC) was linked to high-risk patient after acute myocardial infarction. Studies of HRT were performed on high-risk patients with Holter-Monitors as were most subsequent HRT studies. If HRT could potentially be used as a risk factor of heart disease, it is interesting to study whether HRT is present following a …
Time-Frequency Analysis Of Intracardiac Electrogram, Erik Brockman
Time-Frequency Analysis Of Intracardiac Electrogram, Erik Brockman
Master's Theses
The Cardiac Rhythm Management Division of St. Jude Medical specializes in the development of implantable cardioverter defibrillators that improve the quality of life for patients diagnosed with a variety of cardiac arrhythmias, especially for patients prone to sudden cardiac death. With the goal to improve detection of cardiac arrhythmias, this study explored the value in time-frequency analysis of intracardiac electrogram in four steps. The first two steps characterized, in the frequency domain, the waveforms that construct the cardiac cycle. The third step developed a new algorithm that putatively provides the least computationally expensive way to identifying cardiac waveforms in the …
Mechanical Simulation Of Articular Cartilage Based On Experimental Results, Kevin Matthew Stewart
Mechanical Simulation Of Articular Cartilage Based On Experimental Results, Kevin Matthew Stewart
Master's Theses
Recently, a constituent based cartilage growth finite element model (CGFEM) was developed in order to predict articular cartilage (AC) biomechanical properties before and after growth. Previous research has noted limitations in the CGFEM such as model convergence with growth periods greater than 12 days. The main aims of this work were to address these limitations through (1) implementation of an exact material Jacobian matrix definition using the Jaumann-Kirchhoff (J-K) method and (2) quantification of elastic material parameters based upon research findings of the Cal Poly Cartilage Biomechanics Group (CPGBG). The J-K method was successfully implemented into the CGFEM and exceeded …
The Impact Of Lipid Percentage On Fibrous Cap Stability In Atherosclerotic Lesions, Anita Lorraine Crompton
The Impact Of Lipid Percentage On Fibrous Cap Stability In Atherosclerotic Lesions, Anita Lorraine Crompton
Master's Theses
Coronary artery disease (CAD) is a common cause of sudden cardiac death. Much of the disease is not completely understood, which makes treatment and prevention difficult. Many researchers are using technology, such as advanced imaging techniques and finite element analysis, to better understand the disease. While there is much progress being made to look at the analysis of actual excised diseased arteries, there is still not a standardized model to predict the future of any one lesion. The purpose of this study is to explore the possibility of creating a standardized model to predict the mechanical stability of the fibrous …
Preparation And Characterization Of Electrospun Poly(D, L-Lactide-Co-Glycolide) Scaffolds For Vascular Tissue Engineering And The Advancement Of An In Vitro Blood Vessel Mimic, Tiffany Richelle Pena
Preparation And Characterization Of Electrospun Poly(D, L-Lactide-Co-Glycolide) Scaffolds For Vascular Tissue Engineering And The Advancement Of An In Vitro Blood Vessel Mimic, Tiffany Richelle Pena
Master's Theses
PREPARATION AND CHARACTERIZATION OF ELECTROSPUN POLY(D,L-LACTIDE-CO-GLYCOLIDE) SCAFFFOLDS FOR VASCULAR TISSUE ENGINEERING AND THE ADVANCEMENT OF AN IN VITRO BLOOD VESSEL MIMIC
Tiffany Richelle Peña
Currently, an estimated 1 in every 3 adult Americans are affected by one or more cardiovascular complications. The most common complication is coronary artery disease, specifically atherosclerosis. Outcomes of balloon angioplasty treatments have been significantly improved with the addition of drug eluting stents to the process. Although both bare metal and drug eluting stents have greatly increased the effectiveness of angioplasty and decreased the occurrence of restenosis, several complications still exist. For this reason, the stent …
Design, Fabrication, And Implementation Of A Single-Cell Capture Chamber For A Microfluidic Impedance Sensor, Joshua-Jed Doria Fadriquela
Design, Fabrication, And Implementation Of A Single-Cell Capture Chamber For A Microfluidic Impedance Sensor, Joshua-Jed Doria Fadriquela
Master's Theses
A microfluidic device was created for single-cell capture and analysis using polydimethylsiloxane (PDMS) channels and a glass substrate to develop a microfluidic single-cell impedance sensor for cell diagnostics. The device was fabricated using photolithography to create a master mold which in turn will use soft lithography to create the PDMS components for constant device production. The commercial software, COMSOLTM Multiphysics, was used to quantify the fluid dynamics in shallow micro-channels.
The device will be able to capture a cell and sequester it long enough to enable measurement of the impedance spectra that can characterize cell. The proposed device will be …
Implementation Of Physiologic Flow Conditions In A Blood Vessel Mimic Bioreactor System For The Evaluation Of Intravascular Devices, Marc Cody Dawson
Implementation Of Physiologic Flow Conditions In A Blood Vessel Mimic Bioreactor System For The Evaluation Of Intravascular Devices, Marc Cody Dawson
Master's Theses
The prevalence and devastating nature of cardiovascular diseases has led to many advancements in the therapies used to treat the millions of patients that suffer as a result of these conditions. As coronary artery disease (CAD) is the most common of these cardiovascular conditions, it is a major focus of research among the medical industry. Although lifestyle changes and drug therapies can treat early CAD, more advanced cases often require more definitive interventions. In conjunction with angioplasty, stenting of an occluded vessel has shown significant success in preventing restenosis. However, as with nearly every therapeutic process in the medical field, …