Articles 241 - 270 of 304

Full-Text Articles in Biomedical Engineering and Bioengineering

Equivalent Circuit Implementation Of Demyelinated Human Neuron In Spice, Nathan A. Angel Aug 2011

Equivalent Circuit Implementation Of Demyelinated Human Neuron In Spice, Nathan A. Angel

Master's Theses

This work focuses on modeling a demyelinated Hodgkin and Huxley (HH) neuron with Simulated Program with Integrated Circuit Emphasis (SPICE) platform. Demyelinating disorders affect over 350,000 people in the U.S and understanding the demyelination process at the cellular level is necessary to find safe ways to treat the diseases [9]. Utilizing a previous SPICE model of an electrically small cell neuron developed by Szlavik [32], an extended core conductor myelinated neuron was produced in this work. The myelinated neuron developed has seven active Nodes of Ranvier (nodes) separated by a myelin sheath. The myelin sheath can be successfully modeled with …


Studying Milk Coagulation Kinetics With Laser Scanning Confocal Microscopy, Image Processing, And Computational Modeling, Richard Joseph Hennessy Jun 2011

Studying Milk Coagulation Kinetics With Laser Scanning Confocal Microscopy, Image Processing, And Computational Modeling, Richard Joseph Hennessy

Master's Theses

The kinetics of milk coagulation are complex and still not well understood. A deeper understanding of coagulation and the impact of the relevant factors would aid in both cheese manufacturing and also in determining the nutritional benefits of dairy products. A method using confocal microscopy was developed to follow the movement of milk fat globules and the formation of a milk protein network during the enzyme-induced coagulation of milk. Image processing methods were then used to quantify the rate of coagulation. It was found that the texture of the protein network is an indicator of the current status of the …


Implementation And Assessment Of Hyperglycemic Conditions For The Creation Of A Diabetic Blood Vessel Mimic, Vikramaditya Mediratta Jun 2011

Implementation And Assessment Of Hyperglycemic Conditions For The Creation Of A Diabetic Blood Vessel Mimic, Vikramaditya Mediratta

Master's Theses

Introduction: Diabetes Mellitus is a metabolic disorder that affects a person’s ability to either produce insulin (Type I diabetes mellitus) or properly use insulin (Type II diabetes mellitus) in order to maintain adequate blood glucose levels. The most severe diabetic complications arise due to hyperglycemia – a state of extremely high blood glucose levels – such as, coronary artery disease (CAD), in which coronary stent therapy is a popular method of treatment. However, research has shown a high rate of in-stent restenosis in diabetic patients with CAD, most likely due to activation of cellular adhesion molecules on endothelial cells exposed …


A Novel Exercise Device For Users In Wheelchairs: A Study Of Abdominal Muscle Activation, Rebecca Jo Campbell Jun 2011

A Novel Exercise Device For Users In Wheelchairs: A Study Of Abdominal Muscle Activation, Rebecca Jo Campbell

Master's Theses

This study evaluates the use of a wheelchair balance board. The balance board was created as a sensory stimulation tool for users with various disabilities. It was originally designed to create vestibular stimulation for the person after they were loaded on.  This study was used as a way to test if the balance board could be used for other things such as physical therapy and exercise.  Ten able-bodied individuals were used to show the functionality of the device.  They were asked to perform six different abdominal exercises while the muscle activity of their rectus abdominis and external obliques was measured …


Measuring The Nanoindentation Properties Of Alendronate-Time Treated Canine Cortical, Folorunso Ashaolu Jun 2011

Measuring The Nanoindentation Properties Of Alendronate-Time Treated Canine Cortical, Folorunso Ashaolu

Master's Theses

This study examines the nanoindentation (energy inclusive) properties of 0.2 mg/kg alendronate treated ribs at one and three years against a vehicle treated control in a fresh-frozen, non-cold-mounted, condition.  This was to verify if the tissue-level properties for 0.2 ALN treated beagles would increase because of an increased level of mineralization despite a microdamage increase.

A total of twelve (12) skeletally mature (1–2 years old) female beagle dogs were treated daily for three years and one year with oral doses of vehicle (VEH, 1 mL/kg saline) or alendronate (ALN, 0.2 Merck, Rahway, NJ). The 0.2 mg dose corresponds, on a …


Ischemia Impairs Vasodilation In Skeletal Muscle Resistance Artery, Kyle Remington Struthers Jun 2011

Ischemia Impairs Vasodilation In Skeletal Muscle Resistance Artery, Kyle Remington Struthers

Master's Theses

Functional vasodilation in arterioles is impaired with chronic ischemia. We sought to examine the impact of chronic ischemia and age on skeletal muscle resistance artery function. To examine the impact of chronic ischemia, the femoral artery was resected from young (2-3mo) and adult (6-7mo) mice and the profunda femoris artery diameter was measured at rest and following gracilis muscle contraction 14 days later using intravital microscopy. Functional vasodilation was significantly impaired in ischemic mice (14.4±4.6% vs. 137.8±14.3%, p<0.0001 n=8) and non-ischemic adult mice (103.0±9.4% vs. 137.8±14.3%, p=0.05 n=10). In order to analyze the cellular mechanisms of the impairment, a protocol was developed to apply pharmacological agents to the experimental preparation while maintaining tissue homeostasis. Endothelial and smooth muscle dependent vasodilation were impaired with ischemia, 39.6 ± 13.6% vs. 80.5 ± 11.4% and 43.0 ± 11.7% vs. 85.1 ± 10.5%, respectively. From this data, it can be supported that smooth muscle dysfunction is the reason for the observed impairment in arterial vasodilation.


A Pmma Conductivity Pretreatment Microfluidics Device For The Optimization Of Electrokinetic Manipulations, Cameron Paul Purcell Jun 2011

A Pmma Conductivity Pretreatment Microfluidics Device For The Optimization Of Electrokinetic Manipulations, Cameron Paul Purcell

Master's Theses

This project encompasses the design and development of a pretreatment microfluidic device for samples of physiological conductivity, namely a saline solution. The conductivity was reduced through the combination of dilution and ion removal using electric fields to enable downstream electro kinetic manipulations. The two major parts of this project include (1) designing a pretreatment protocol to reduce the conductivity of the sample solution to an acceptable level and (2) designing /fabricating a microchip that will effectively allow aim (1) to be performed on chip.

This project is one of the first to observe the effects of an electric field, used …


Development Of An Open Source Prosthetic Hand Platform, Scott James Garrett Jun 2011

Development Of An Open Source Prosthetic Hand Platform, Scott James Garrett

Master's Theses

Development of an Open Source Prosthetic Hand Platform

Scott Garrett

In the field of upper extremity prosthetic devices, advancements in technology drive the design of products which are becoming capable of restoring the lost functions of the native hand. While several dexterous devices have been developed to serve this purpose, they remain prohibitively expensive and thus are not a viable option for many upper extremity amputees. To address this problem a prosthetic hand platform was developed utilizing the open source Arduino microcontroller and off-the-shelf electrical components. Using these resources, a novel finger actuation mechanism was developed to show how …


Characterization And Implementation Of A Decellularized Porcine Vessel As A Biologic Scaffold For A Blood Vessel Mimic, Aubrey N. Smith Jun 2011

Characterization And Implementation Of A Decellularized Porcine Vessel As A Biologic Scaffold For A Blood Vessel Mimic, Aubrey N. Smith

Master's Theses

Every 34 seconds, someone in the United States suffers from a heart attack.  Most heart attacks are caused by atherosclerotic build up in the coronary arteries, occluding normal blood flow.  Balloon angioplasty procedures in combination with a metal stent often result in successful restoration of normal blood flow.  However, bare metal stents often lead to restenosis and other complications.  To compensate for this problem, industry has created drug-eluting stents to promote healing of the artery wall post stenting.  These stents are continually advancing toward better drug-eluting designs and methods, resulting in a need for fast and reliable pre-clinical testing modalities. …


Seawater/Wastewater Production Of Microalgae-Based Biofuels In Closed Loop Tubular Photobioreactors, Joshua Bradley Lowrey Jun 2011

Seawater/Wastewater Production Of Microalgae-Based Biofuels In Closed Loop Tubular Photobioreactors, Joshua Bradley Lowrey

Master's Theses

The push for alternatives to petroleum fuels has forced researchers to look for highly productive, renewable, non-food resources.  The advantages of using microalgae instead of traditional oil crops for biofuel production include high oil yields, rapid reproductive rates, and versatile growing requirements.  In order to reduce the cost of producing microalgae based biofuels, wastewater has been used as a nutrient source instead of specialized plant nutrients.  The purpose of this study was to compare the relative effectiveness of different combinations of microalgae strain and dairy wastewater for increasing biomass.  The methods for monitoring growth included optical density, cell counting, biomass …


Finite Element Analysis Of The Effect Of Low-Speed Rear End Collisions On The Medial Meniscus, Daniel J. Tichon May 2011

Finite Element Analysis Of The Effect Of Low-Speed Rear End Collisions On The Medial Meniscus, Daniel J. Tichon

Master's Theses

Low-speed, rear end vehicle collisions can inflict soft tissue damage to the passenger’s knees, especially the medial meniscus, which has been previously unexplained in published literature.  It is difficult to determine if factors such as age or other injury was the primary cause of the injury or if the accident acutely caused the meniscal tear.  Rear end collisions may produce a combination of compressive loading and torque about the knee that will injure the medial meniscus during the initial impact and the rebound phase.  The purpose of this study is to determine if it is possible for rear end low-speed …


Noninvasive Assessment Of Joint Motion Over Long Durations: System Evaluation And Data Analysis Methods, Maria J. Qadri May 2011

Noninvasive Assessment Of Joint Motion Over Long Durations: System Evaluation And Data Analysis Methods, Maria J. Qadri

Master's Theses

The development, progression, and treatment of degenerative musculoskeletal diseases, such as carpal tunnel and shoulder impingement syndromes, may be better characterized when joint motions are assessed over long durations outside clinical, laboratory, or rehabilitation settings that involve standardized assessment, exercise protocols, and/or regimented movements. Assessment methods for human movement capture beyond laboratory or clinical experiments are typically limited to short capture times of less than one hour. Noninvasive, long-duration measurements of joint motion in occupational settings provides more insight into movement patterns and quantitative assessments regarding joint usage, which lead to a better understanding of the cumulative effects associated with …


A Comparative Study Of Total Hemoglobin Measurement Technology: Noninvasive Pulse Co-Oximetry And Conventional Methods, Jared S. Ruckman May 2011

A Comparative Study Of Total Hemoglobin Measurement Technology: Noninvasive Pulse Co-Oximetry And Conventional Methods, Jared S. Ruckman

Master's Theses

Hemoglobin can be measured on a variety of devices using different principles of operation. Noninvasive pulse CO-oximetry represents the latest development in hemoglobin measuring technology. The technology uses principles similar to pulse oximetry to measure total hemoglobin, oxyhemoglobin, reduced oxyhemoglobin, carboxyhemoglobin and methemoglobin. Similar to the introduction of pulse oximetry to the medical field, pulse CO-oximetry has been met with skepticism. Since the technology is noninvasive and provides continuous monitoring in comparison to invasive and discrete techniques used in other methods, CO-oximetry purportedly provides an advantage in patient care. The purpose of this research is threefold: (a) to review the …


The Use Of Motion Analysis Technology As An Alternative Means Of Assessing Spinal Deformity In Patients With Adolescent Idiopathic Scoliosis, Matthew J. Solomito May 2011

The Use Of Motion Analysis Technology As An Alternative Means Of Assessing Spinal Deformity In Patients With Adolescent Idiopathic Scoliosis, Matthew J. Solomito

Master's Theses

Adolescent Idiopathic Scoliosis (AIS) is a three dimensional deformity of the spine that causes abnormal curvatures in the coronal and sagittal planes and abnormal vertebral rotations. The gold standard for diagnosing and tracking the progression of the deformity is through the use of repeated radiography and a patient can receive upwards of fifteen radiographic series over the course of treatment, which exposes this population to an increased risk of radiation-dependent complications.

This thesis presents the necessary calculations and the marker set required to make the motion capture technology a viable alternative to radiographs, in an effort to reduce the patient’s …


Design Of A Pragmatic Test Lab For Evaluating And Testing Wireless Medical Devices For Deployment On An Integrated It Wireless Network, Allie Paquette May 2011

Design Of A Pragmatic Test Lab For Evaluating And Testing Wireless Medical Devices For Deployment On An Integrated It Wireless Network, Allie Paquette

Master's Theses

In today’s healthcare environment, networking of medical devices is becoming more and more prevalent. There is an increasing need for mobile technology to meet clinical needs. Wireless communication is essential for allowing medical devices to be able to move with the patient, while continuing to record and communicate patient data. A traditional example is telemetry monitoring, but other examples of wireless utilization include sending ECG test results to the EMR or remotely updating the drug library on numerous IV pumps. Each wireless application has varying demands on the connectivity infrastructure and will share radio frequency (RF) spectrum resources with a …


Characterization And Implementation Of Low Intensity Pulsed Ultrasound As A Tool To Apply Physical Load To Scaffolds And Bone Cells For Fracture Repair, Scott Frazee May 2011

Characterization And Implementation Of Low Intensity Pulsed Ultrasound As A Tool To Apply Physical Load To Scaffolds And Bone Cells For Fracture Repair, Scott Frazee

Master's Theses

One current challenge in treating bone fractures is the effective treatment of non-unions and delayed unions. Low Intensity Pulsed Ultrasound (LIPUS) has been approved by the FDA to treat fresh fractures since 1994 and non-unions since 2000 and is an attractive treatment option because it is non-invasive. The mechanism by which it works, however, is not well understood; what is known is largely confined to the resultant changes in chemical output of cells. In this thesis several concepts and techniques were brought together to investigate the following hypothesis: LIPUS produces a measurable physical load that results in measurable deformation and …


Mammary Epithelial Cell Growth On A Three-Dimensional Scaffold In An Operating Bioreactor, Melissa Marie Davalle May 2011

Mammary Epithelial Cell Growth On A Three-Dimensional Scaffold In An Operating Bioreactor, Melissa Marie Davalle

Master's Theses

Mammary epithelial cells are highly efficient secreting cells. With genetic engineering, the uses of these cells could be endless. Research is being conducted on these cells to determine their full potential to the biotech industry.

This paper investigates whether bovine epithelial mammary cells can survive in glutaraldehyde-treated gelatin tubes in an operating bioreactor. Many bioreactors were developed and tested to suit the needs of the cells. Procedures were created and carried out to ensure sterility of the bioreactors. Bovine mammary epithelial cells were implanted in the bioreactors and samples of their growth were taken over time.


Investigation Of A Simulated Annealing Cooling Schedule Used To Optimize The Estimation Of The Fiber Diameter Distribution In A Peripheral Nerve Trunk, Arya Vigeh May 2011

Investigation Of A Simulated Annealing Cooling Schedule Used To Optimize The Estimation Of The Fiber Diameter Distribution In A Peripheral Nerve Trunk, Arya Vigeh

Master's Theses

In previous studies it was determined that the fiber diameter distribution in a peripheral nerve could be estimated by a simulation technique known as group delay. These results could be further improved using a combinatorial optimization algorithm called simulated annealing. This paper explores the structure and behavior of simulated annealing for the application of optimizing the group delay estimated fiber diameter distribution. Specifically, a set of parameters known as the cooling schedule is investigated to determine its effectiveness in the optimization process.

Simulated annealing is a technique for finding the global minimum (or maximum) of a cost function which may …


Design And Development Of Two Test Fixtures To Test The Longitudinal And Transverse Tensile Properties Of Small Diameter Tubular Polymers, Carolyn Berry Apr 2011

Design And Development Of Two Test Fixtures To Test The Longitudinal And Transverse Tensile Properties Of Small Diameter Tubular Polymers, Carolyn Berry

Master's Theses

Hundreds of thousands of vascular bypass grafts are implanted in the United States every year, but there has yet to be an ideal graft material to substitute for one’s own autologous vessel. Many synthetic materials have been shown to be successful vessel replacements; however, none have been proven to exhibit the same mechanical properties as native vessels, one of the most important criteria in selecting a vascular graft material. Part of this issue is due to the fact that, currently, there is no “gold standard” for testing the longitudinal and transverse tensile properties of small diameter tubular materials. While there …


A Study Of Osteocyte Apoptosis By Region And Quadrant In Murine Cortical Bone, Jessica Kristen Chan Mar 2011

A Study Of Osteocyte Apoptosis By Region And Quadrant In Murine Cortical Bone, Jessica Kristen Chan

Master's Theses

ABSTRACT

A Study of Osteocyte Apoptosis by Region and Quadrant in Murine Cortical Bone

Jessica Kristen Chan

Osteocytes undergo apoptosis to spatially and temporally initiate bone remodeling.  This study investigates the distribution of apoptotic osteocytes within different quadrants and regions of cortical bone and compares the frequency of osteocyte apoptosis to regional factors associated with bone remodeling.  Specifically, the quantity of apoptosis was compared to levels of the bone morphagenic protein antagonists noggin and gremlin.  Samples of unloaded right tibial bone obtained from C57/Bl/6 mice underwent TUNEL staining for apoptotic osteocytes and were counterstained with methyl green to detect osteocyte …


Universal Engineering Programmer – An In-House Development Tool For Developing And Testing Implantable Medical Devices In St. Jude Medical, Khoa Tat Do Mar 2011

Universal Engineering Programmer – An In-House Development Tool For Developing And Testing Implantable Medical Devices In St. Jude Medical, Khoa Tat Do

Master's Theses

During development and testing of the functionality of the pacemaker and defibrillator device, engineers in the St. Jude Medical Cardiac Rhythm Management Division use an in-house development tool called Universal Engineering Programmer (UEP) to ensure the device functions as expected, before it can be used to test on an animal or a human during the implantation process.  In addition, some applications of UEP are incorporated into the official releases of the device product.  UEP has been developed and used by engineers across departments in the St. Jude Medical Cardiac Rhythm Management Division (CRMD).  This thesis covers the flexible and reusable …


Laser Etched Pmma Microfluidic Chip Design And Manufacture With Applications In Capillary Zone Electrophoresis, Evan Allen Barbre Feb 2011

Laser Etched Pmma Microfluidic Chip Design And Manufacture With Applications In Capillary Zone Electrophoresis, Evan Allen Barbre

Master's Theses

This thesis encompasses a feasibility study of using low-cost materials to manufacture microfluidic chips that can perform the same functions as chips manufactured using traditional methods within an acceptable range of efficiency of chips created with more exotic methods and materials. The major parts of the project are the selection and characterization of the fabrication methods for creating the channels for fluid flow, the methods for sealing the channels to create a usable chip and the electrophoretic separations of carboxylated microspheres of different potentials. In this work we seek to answer the question if laser-etched PMMA microfluidic chips are comparable …


Sar Map Of Gel Phantom In A 64mhz Mri Birdcage By Fiber-Optic Thermometry And Fdtd Simulation, Chirag Mukesh Patel Feb 2011

Sar Map Of Gel Phantom In A 64mhz Mri Birdcage By Fiber-Optic Thermometry And Fdtd Simulation, Chirag Mukesh Patel

Master's Theses

As implantable medical devices are being used more often to treat medical problems for which pharmaceuticals don’t suffice, it is important to understand their interactions with commonly used medical modalities. The interactions between medical implants and Magnetic Resonance Imaging machines have proven to be a risk for patients with implants.

Implanted medical devices with elongated metallic components can create harmful levels of local heating in a Magnetic Resonance Imaging (MRI) environment [1]. The heating of a biological medium under MRI is monitored via the Specific Absorption Rate (SAR). SAR, defined as power absorbed per unit mass (W/kg), can be calculated …


Modeling Of Aortic Valve Anatomic Geometry From Clinical Multi Detector-Row Computed Tomography Images, Gregory A. Book Dec 2010

Modeling Of Aortic Valve Anatomic Geometry From Clinical Multi Detector-Row Computed Tomography Images, Gregory A. Book

Master's Theses

Transcatheter aortic valve implantation (TAVI) is an emerging and viable alternative to surgical valve replacement. A TAVI procedure involves insertion of a catheter into the heart through an artery or transapically, and expanding valve stent in place. This procedure dramatically reduces the recovery time by eliminating the need for open heart surgery. Understanding the biomechanics of the stent-valve interaction is crucial for proper device deployment and function. In this study, we examine the extraction of valve geometries and creation of valve models from multi-detector row computed tomography (MDCT) images that may eventually be used to model stent expansion on a …


The Development And Validation Of A Finite Element Model Of A Canine Rib For Use With A Bone Remodeling Algorithm., Scott J. Sylliaasen Dec 2010

The Development And Validation Of A Finite Element Model Of A Canine Rib For Use With A Bone Remodeling Algorithm., Scott J. Sylliaasen

Master's Theses

Studies are currently being performed to determine the effects of bisphosphonate treatments on the structure and density of bone tissue. One of the pathways for gaining a better understanding of the effects of this and other treatments involves creating a computer simulation. Theory suggests that bone tissue structure and density are directly related to the manner in which the tissue is loaded. Remodeling is the process in which bone tissue is resorbed in areas of low stress distributions, and generated in areas of high stress distributions. Previous studies have utilized numerical methods and finite element methods to predict bone structure …


Assessment Of Morphology And Hemodynamics In Normal And Remodeled Microvasculature With Parameter Sensitivity Analysis, Shilpi Ghosh Dec 2010

Assessment Of Morphology And Hemodynamics In Normal And Remodeled Microvasculature With Parameter Sensitivity Analysis, Shilpi Ghosh

Master's Theses

The goal of this study was to compare the morphological and hemodynamic characteristics of normal and remodeled vascular networks in the mouse gracilis muscle. To this end, previously developed models to assess flows and vascular branching were used to assess the normal and remodeled microcirculatory networks. The analysis revealed that the average individual vessel flow rates for vessels of similar caliber and total volumetric flow rates in the networks do not change for vessels of the same caliber after remodeling. Connectivity changes and average diameters primarily change in the larger arterioles after remodeling. A few correlations could be made between …


Multi-Frequency Processing For Lumen Enhancement With Wideband Intravascular Ultrasound, Rory A. Carrillo Sep 2010

Multi-Frequency Processing For Lumen Enhancement With Wideband Intravascular Ultrasound, Rory A. Carrillo

Master's Theses

The application of high frequency ultrasound is the key to higher resolution intravascular ultrasound (IVUS) images. The need to further improve the IVUS spatial resolution may drive the transducer center frequency even higher than the current 40 MHz range. However, increasing the center frequency may be challenging as it leads to stronger scattering echoes from blood. The high level of blood scattering echoes may obscure the arterial lumen and make image interpretation difficult. Blood backscatter levels increase with transmission center frequency at a much greater rate compared to arterial tissue. These different frequency dependencies provide a potential method to distinguish …


St. Jude Medical: Enhanced Mics (Emics), Devanshi Shah Aug 2010

St. Jude Medical: Enhanced Mics (Emics), Devanshi Shah

Master's Theses

Heart disease is one of the most prevalent diseases in the world. The survival chances for patients with ventricular fibrillation/ventricular tachycardia reduces significantly as time passes without treatment and even after getting timely treatment recurring episode are common. These patients can benefit from an Implantable Cardioverter Defibrillator (ICD) which can monitor heart rhythm and provide immediate treatment. Due to the ever changing physical conditions and disease progression, the ICD needs to collect diagnostic data as well as support programming by the physician. The ICD uses inductive telemetry and radio-frequency telemetry for the communication with the external devices such as a …


Integration Of Microfluidics With Surface Plasmon Resonance, Scott B. Fratzke Aug 2010

Integration Of Microfluidics With Surface Plasmon Resonance, Scott B. Fratzke

Master's Theses

This thesis successfully integrates laminate microfluidic devices with an analytic Surface Plasmon Resonance (SPR) instrument. Integration was accomplished at low-cost using materials such as polydimethylsiloxane (PDMS), Poly(methyl methacrylate) (PMMA), Tygon tubing, and a 3-way stopcock. The main components of this thesis are the design and fabrication of the low-cost, in-house fluidics that can integrate with upstream microfluidics and the validation of the in-house fluidics using the Biosensing Instruments BI-2000 SPR instrument. The low-cost fluidics was designed and fabricated “in-house” using a novel investment casting technique that required the use of laser cutting technology to make a master cast, and candle …


St. Jude Medical: An Object-Oriented Software Architecture For Embedded And Real-Time Medical Devices, Atila Amiri Aug 2010

St. Jude Medical: An Object-Oriented Software Architecture For Embedded And Real-Time Medical Devices, Atila Amiri

Master's Theses

Medical devices used for surgical or therapeutic purposes require a high degree of safety and effectiveness. Software is critical component of many such medical devices. The software architecture of a system defines organizational structure and the runtime characteristic of the application used to control the operation of the system and provides a set of frameworks that are used to develop that. As such, the design of software architecture is a critical element in achieving the intended functionality, performance, and safety requirements of a medical device. This architecture uses object-oriented design techniques, which model the underlying system as a set of …