Open Access. Powered by Scholars. Published by Universities.®

Physical Sciences and Mathematics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 61 - 69 of 69

Full-Text Articles in Physical Sciences and Mathematics

Emisja Zanieczyszczeń Ze Spalania Odpadów Przemysłowych W Piecu Obrotowym, Robert Oleniacz, Marian Mazur, Marek Bogacki Dec 1996

Emisja Zanieczyszczeń Ze Spalania Odpadów Przemysłowych W Piecu Obrotowym, Robert Oleniacz, Marian Mazur, Marek Bogacki

Robert Oleniacz

The paper presents the results of measurements of the concentration of selected pollutants in the flue gases from the incineration of industrial wastes in a full-scale rotary kiln. The study included three waste mixtures introduced into the kiln: 1) coal tar waste (tar origin of coke); 1) waste paints, varnish and lubricant; 3) resin and rubber waste. The article also assesses the effectiveness of the existing wet flue gas cleaning system (alkaline scrubber) and specifies minimum exhaust gas purifying performance guarantees compliance with European emission standards for waste incineration.

English title: Pollutant emissions from incineration of industrial waste in a …


Emisja Związków Siarki Z Procesu Wielkopiecowego, Marian Mazur, Marek Bogacki, Robert Oleniacz Nov 1996

Emisja Związków Siarki Z Procesu Wielkopiecowego, Marian Mazur, Marek Bogacki, Robert Oleniacz

Robert Oleniacz

The paper describes the problem of the presence of sulfur in the blast furnace process and identifies emission sources of sulfur compounds in this process. On the basis of the measurements and calculations, the types and quantities of these compounds emitted to the air were determined. It was found that pig iron smelting in a blast furnace causes emissions of COS, SO2 and H2S. These emissions occur by losses of blast furnace gas (COS and SO2), transport of blast furnace slag inside the furnace hall (SO2) and treatment of the slag by granulation (H2S). However, the most important are only …


Wpływ Komponentów Alkalicznych W Procesach Spiekania I Wielkopiecowym Na Technologię I Emisję Zanieczyszczeń, Marian Mazur, Ryszard Benesch, Andrzej Łędzki, Robert Oleniacz Nov 1996

Wpływ Komponentów Alkalicznych W Procesach Spiekania I Wielkopiecowym Na Technologię I Emisję Zanieczyszczeń, Marian Mazur, Ryszard Benesch, Andrzej Łędzki, Robert Oleniacz

Robert Oleniacz

The paper presents the impact of alkali metals on sintering and blast furnace processes and air pollutant emissions including particulate matter. On the basis of the balance calculations, it was found that the main source of alkali (Na2O and K2O) in the sintering process is a raw mixture unweathered. The calculations showed that the level of dust emissions from the sinter strand to a large extent depends on: the total alkali content in a mixture of sinter, ash content in coke breeze, K2O concentration in coke ash and alkalinity of the produced sinter. Alkali metals are introduced into the blast …


Monitoring Zanieczyszczeń Powietrza Wokół Elektrowni "Jaworzno Iii", Marian Mazur, Robert Oleniacz, Marek Bogacki, Ryszard Kozakiewicz Sep 1996

Monitoring Zanieczyszczeń Powietrza Wokół Elektrowni "Jaworzno Iii", Marian Mazur, Robert Oleniacz, Marek Bogacki, Ryszard Kozakiewicz

Robert Oleniacz

The article presents the concept of system of monitoring of air pollution around the Power Plant "Jaworzno III" in Jaworzno (Poland), whose objective is to evaluate the impact of this object on air quality. This system is based on a few measuring points and a mobile station should also allow for the assessment of ecological effects associated with the use of low-emission burners in power boilers (reduction of NOx emission) and run the wet installation of flue gas desulfurization (reduction of SO2 emission). An additional aim of the measurements is to identify the possible effects of a changes in the …


Kompleksowa Ocena Jakości Powietrza W Nowym Sączu Przy Pomocy Metody Obliczeniowo-Pomiarowej, Marian Mazur, Marek Bogacki, Robert Oleniacz Sep 1996

Kompleksowa Ocena Jakości Powietrza W Nowym Sączu Przy Pomocy Metody Obliczeniowo-Pomiarowej, Marian Mazur, Marek Bogacki, Robert Oleniacz

Robert Oleniacz

The paper presents the results of a comprehensive assessment of air pollution in the city of Nowy Sącz (Poland). This involved determining the emissions of selected pollutants from various sources with their percentages of the total emission and immission on the area under consideration. As a result of measurement of concentrations of particulate matter and benzo(a)pyrene in several parts of the city were verified results of theoretical calculations and determined the size of the inflow of pollutants from outside the area in question.

English title: A comprehensive assessment of air quality in Nowy Sącz using computational and measuring methods.


Emisja Chlorowodoru I Związków Fluoru Ze Spalania Odpadów Niebezpiecznych, Marian Mazur, Robert Oleniacz, Marek Bogacki Jun 1996

Emisja Chlorowodoru I Związków Fluoru Ze Spalania Odpadów Niebezpiecznych, Marian Mazur, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

The paper presents the results of measurements of the concentration of hydrogen chloride (HCl) and fluoride compounds (as HF) in raw and purified combustion gases discharged from the incineration of selected hazardous wastes. The study included two installations operating on an industrial scale: a multiple hearth furnace and a rotary kiln incinerator equipped with a single wet flue gas cleaning systems. In the multiple hearth furnace was being incinerated sludge from coke industry. In the rotary kiln were being incinerated coal (coke) tars, contaminated cleaning rags, sawdust, used gloves, outdated pharmaceuticals and medicines, hospital waste, waste paints, varnish and lubricant, …


Termiczna Utylizacja Odpadów W Spalarni "Lobbe" W Dąbrowie Górniczej – Problemy Emisji Zanieczyszczeń, Marian Mazur, Ryszard Januszek, Robert Oleniacz May 1996

Termiczna Utylizacja Odpadów W Spalarni "Lobbe" W Dąbrowie Górniczej – Problemy Emisji Zanieczyszczeń, Marian Mazur, Ryszard Januszek, Robert Oleniacz

Robert Oleniacz

The paper presents selected results of comprehensive studies of air quality impact assessment carried out for the „LOBBE” incineration plant in Dąbrowa Górnicza (Poland) in 1995. It focused mainly on air emissions problems. Stack concentrations and emissions of selected air pollutants formed during thermal treatment processes of different kinds of waste materials and incinerators is performed. The study covered both sludge and slime incinerated in a multiple hearth furnace and four example groups of waste materials incinerated in a rotary furnace. The research have helped confirm the levels of air emissions as a function of the type of incinerated waste …


Zanieczyszczenie Powietrza Kotliny Sądeckiej Przez Przemysł Elektrodowy, Marian Mazur, Marek Bogacki, Robert Oleniacz Feb 1996

Zanieczyszczenie Powietrza Kotliny Sądeckiej Przez Przemysł Elektrodowy, Marian Mazur, Marek Bogacki, Robert Oleniacz

Robert Oleniacz

The article evaluates the impact of electrode industry (production of carbon and graphite electrodes in the plant Polgraph SA) on air quality in the Kotlina Sądecka valley and the city Nowy Sącz (Poland). The work presents completed so far environmental investments and the level of emissions of selected air pollutants characteristic of the analyzed facility, including PAHs emissions. Based on the modeling of the dispersion of pollutants in ambient air was determined the levels of pollutant concentrations in the air and location of most affected areas. The calculation results were compared with the results of direct measurements. Particular attention was …


Ocena I Weryfikacja Lokalizacji Stanowisk Pomiarowych Imisji Zanieczyszczeń Powietrza W Województwie Kieleckim, Marian Mazur, Robert Oleniacz Jun 1995

Ocena I Weryfikacja Lokalizacji Stanowisk Pomiarowych Imisji Zanieczyszczeń Powietrza W Województwie Kieleckim, Marian Mazur, Robert Oleniacz

Robert Oleniacz

The paper presents the implementation of air pollution monitoring in the province of Kielce (Poland), associated with verification of the location and the measuring range of points to measure the concentrations of air pollutants. For this purpose were used calculations of the pollutants dispersion and statistical analysis of measurement results obtained on existing measuring stations. In the statistical calculations were used analysis of variance homogeneity, based on Cochran, Bartlett and Hartley tests. As a result of analysis and calculations, it was found that the original location is not always correct and does not reflect the spatial differentiation of pollutant concentrations. …