Open Access. Powered by Scholars. Published by Universities.®
- Discipline
- Institution
- Publication
- Publication Type
Articles 1 - 7 of 7
Full-Text Articles in Plasma and Beam Physics
Impulse Measurement Methods For Pulsed Laser Ablation Propulsion, Ishaan Mishra, Scott Kirkpatrick
Impulse Measurement Methods For Pulsed Laser Ablation Propulsion, Ishaan Mishra, Scott Kirkpatrick
Rose-Hulman Undergraduate Research Publications
Pulsed laser ablation propulsion has the potential to revolutionize space exploration by eliminating the requirement of a spacecraft to carry its propellant and power source as the high-power laser is situated off-board. More experimentation needs to be done to optimize this propulsion system and understand the mechanisms of thrust generation. There are many methods used to calculate the impulse imparted in pulsed laser ablation experiments. In this paper, key performance parameters are derived for some of the impulse measurement methods used in ablation propulsion experiments. Regimes discussed include the torsional pendulum system, simple pendulum system, and solid and liquid microspheres.
Plasma Spectroscopy Of Titanium Monoxide For Characterization Of Laser Ablation, Todd A. Van Woerkom, Glen P. Perram, Christian G. Parigger, Brian D. Dolasinski, Charles D. Phelps, Patrick A. Berry
Plasma Spectroscopy Of Titanium Monoxide For Characterization Of Laser Ablation, Todd A. Van Woerkom, Glen P. Perram, Christian G. Parigger, Brian D. Dolasinski, Charles D. Phelps, Patrick A. Berry
Faculty Publications
Ablation of titanium wafers in air is accomplished with 60 µs pulsed, 2.94 µm laser radiation. Titanium monoxide spectra are measured in the wavelength range of 500 nm to 750 nm, and molecular signatures include bands of the C3 Δ → X3 Δ α, B3 Π → X3 Δ γ', and A3 Φ → X3 Δ γ transitions. The spatially and temporally averaged spectra appear to be in qualitative agreement with previous temporally resolved studies that employed shorter wavelengths and shorter pulse durations than utilized in this work. The background signals in the current study are possibly due to particulate …
Aluminum Multicharged Ion Generation From Femtosecond Laser Plasma, Md. Haider A. Shaim, Frederick Guy Wilson, Hani E. Elsayed-Ali
Aluminum Multicharged Ion Generation From Femtosecond Laser Plasma, Md. Haider A. Shaim, Frederick Guy Wilson, Hani E. Elsayed-Ali
Electrical & Computer Engineering Faculty Publications
Aluminum multicharged ion generation from femtosecond laser ablation is studied. A Ti:sapphire laser (wavelength 800 nm, pulse width ∼100 fs, and maximum laser fluence of 7.6 J/cm2) is used. Ion yield and energy distribution of each charge state are measured. A linear relationship between the ion charge state and the equivalent acceleration energy of the individual ion species is observed and is attributed to the presence of an electric field within the plasma-vacuum boundary that accelerates the ions. The ion energy distribution follows a shifted Coulomb-Boltzmann distribution. For Al1+ and Al2+, the ion energy distributions …
Spark Discharge Coupled Laser Multicharged Ion Source, Md. Haider A. Shaim, Hani E. Elsayed-Ali
Spark Discharge Coupled Laser Multicharged Ion Source, Md. Haider A. Shaim, Hani E. Elsayed-Ali
Electrical & Computer Engineering Faculty Publications
A spark discharge is coupled to a laser multicharged ion source to enhance ion generation. The laser plasma triggers a spark discharge with electrodes located in front of the ablated target. For an aluminum target, the spark discharge results in significant enhancement in the generation of multicharged ions along with higher charge states than observed with the laser source alone. When a Nd:YAG laser pulse (wavelength 1064 nm, pulse width 7.4 ns, pulse energy 72 mJ, laser spot area on target 0.0024 cm2) is used, the total multicharged ions detected by a Faraday cup is 1.0 nC with …
Ir Nonlinear Absorption Leading To Laser-Induced Damage In Ge & Gasb, Torrey J. Wagner, Matthew J. Bohn, Ronald A. Coutu Jr., L. P. Gonzales, J. M. Murray, K. L. Schepler, S. Guha
Ir Nonlinear Absorption Leading To Laser-Induced Damage In Ge & Gasb, Torrey J. Wagner, Matthew J. Bohn, Ronald A. Coutu Jr., L. P. Gonzales, J. M. Murray, K. L. Schepler, S. Guha
Faculty Publications
Using a simultaneous fitting technique to extract nonlinear absorption coefficients from data at two pulse widths, we measure two-photon and free-carrier absorption coefficients for Ge and GaSb at 2.05 and 2.5 μm for the first time. Results agreed well with published theory. Single-shot damage thresholds were also measured at 2.5 μm and agreed well with modeled thresholds using experimentally determined parameters including nonlinear absorption coefficients and temperature dependent linear absorption. The damage threshold for a single-layer Al2O3 anti-reflective coating on Ge was 55% or 35% lower than the uncoated threshold for ps or ns pulses, respectively. Wavelength-dependant …
Electronic State Distributions Of Y Ba2Cu3O7-X Laser Ablated Plumes, Patrick D. Kee
Electronic State Distributions Of Y Ba2Cu3O7-X Laser Ablated Plumes, Patrick D. Kee
Theses and Dissertations
The application of spectral and imagery diagnostics to YBa2Cu3O7 (YBCO) laser-ablated plumes was systematically studied to determine their effectiveness for process control. Emission signatures were collected for plumes created by ablating bulk YBCO with a pulsed laser source. A KrF (λ=248 nm) laser source operating at 4-10 J/cm2 at a 4-10 Hz pulse repetition frequency was used to ablate a bulk YBCO target at O2 background pressures ranging from 50 to 400 mTorr. Emission spectra were collected over the 500 to 860 nm bandpass at distances from the target ranging from 31.4 to …
Investigation Of Ba, Bao, Sr And Sro Pulsed Laser-Induced Vapor Plumes In N2, O2, Microwave Discharged O2, And Vacuum At Low Laser Fluence, David L. Byers
Investigation Of Ba, Bao, Sr And Sro Pulsed Laser-Induced Vapor Plumes In N2, O2, Microwave Discharged O2, And Vacuum At Low Laser Fluence, David L. Byers
Theses and Dissertations
Ba, BaO, Sr and SrO were ablated by 248 nm laser pulses at fluences ranging from 270 mJ-/cm2 to 575 mJ-/cm2 in vacuum and in 25 mtorr atmospheres of N2, O2 and microwave-discharged O2. The spectral emissions of these plumes were compared for indications of ionization due to Ba or Sr collisions with each gas. The addition of a background gas increased the ion and neutral signature across the spectrum. SrO band emission was observed at 16,600-16,900/cm and possible BaO band emissions were observed in the 18,250-18,400/cm, 19,000-19700/cm and 19,800-20,000/cm regions. A screened plate ion probe …