Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Engineering (12)
- Electrical and Computer Engineering (9)
- Electromagnetics and Photonics (5)
- Atomic, Molecular and Optical Physics (2)
- Biological and Chemical Physics (2)
-
- Condensed Matter Physics (2)
- Materials Science and Engineering (2)
- Other Electrical and Computer Engineering (2)
- Other Physics (2)
- Signal Processing (2)
- Aeronautical Vehicles (1)
- Aerospace Engineering (1)
- American Studies (1)
- Arts and Humanities (1)
- Astrophysics and Astronomy (1)
- Computer Engineering (1)
- Instrumentation (1)
- Multivariate Analysis (1)
- Nanotechnology Fabrication (1)
- Other Astrophysics and Astronomy (1)
- Plasma and Beam Physics (1)
- Semiconductor and Optical Materials (1)
- Stars, Interstellar Medium and the Galaxy (1)
- Statistics and Probability (1)
- Institution
- Publication Year
- Publication
- Publication Type
Articles 1 - 17 of 17
Full-Text Articles in Optics
Novel As-S-Se Compositions Of Solution-Processed Chalcogenide Thin Films For Infrared Optics, Annabella Orsini
Novel As-S-Se Compositions Of Solution-Processed Chalcogenide Thin Films For Infrared Optics, Annabella Orsini
Physics and Astronomy Honors Papers
Chalcogenide glasses (ChGs) have a wide range of interdisciplinary applications. In industry, ChGs are used to vastly improve infrared sight abilities. There are, however, improvements that can be made to the films’ stability, cost, and flexibility. Our project seeks to produce thin films that have these improvements, with capabilities comparable or better than what is widely used in the field. Thin films created through solution-based processes have proven to be much more flexible in comparison to bulk glass versions. Other elements in Group 16, such as Sulfur and Selenium have shown across literature to be a cost-effective alternative to Tellurium …
Characterization Of Infrared Metasurface Optics With An Optical Scatterometer, Matthew R. Miller
Characterization Of Infrared Metasurface Optics With An Optical Scatterometer, Matthew R. Miller
Theses and Dissertations
An optical scatterometer is used to characterize the infrared scatter of a dielectric metasurface cylindrical lens and two variants of that design. The design uses dielectric nanopillars to create the parabolic phase delay required for lensing; the variants change the length of the nanopillars from the design length of 4 microns to 0.9 and 5.2 microns. Scatter measurements were made at the design wavelength of 4 microns, and at 3.39 and 5 microns. These measurements showed wide-angle scatter greater than that measured for a conventional refractive optic, and that these metasurfaces perform their optical function best at the design wavelength …
Free Charge Carrier Properties In Two-Dimensional Materials And Monoclinic Oxides Studied By Optical Hall Effect, Sean Knight
Free Charge Carrier Properties In Two-Dimensional Materials And Monoclinic Oxides Studied By Optical Hall Effect, Sean Knight
Department of Electrical and Computer Engineering: Dissertations, Theses, and Student Research
In this dissertation, optical Hall effect (OHE) measurements are used to determine the free charge carrier properties of important two-dimensional materials and monoclinic oxides. Two-dimensional material systems have proven useful in high-frequency electronic devices due to their unique properties, such as high mobility, which arise from their two-dimensional nature. Monoclinic oxides exhibit many desirable characteristics, for example low-crystal symmetry which could lead to anisotropic carrier properties. Here, single-crystal monoclinic gallium oxide, an AlInN/GaN-based high-electron-mobility transistor (HEMT) structure, and epitaxial graphene are studied as examples. To characterize these material systems, the OHE measurement technique is employed. The OHE is a physical …
Infrared And Electro-Optical Stereo Vision For Automated Aerial Refueling, William E. Dallmann
Infrared And Electro-Optical Stereo Vision For Automated Aerial Refueling, William E. Dallmann
Theses and Dissertations
Currently, Unmanned Aerial Vehicles are unsafe to refuel in-flight due to the communication latency between the UAVs ground operator and the UAV. Providing UAVs with an in-flight refueling capability would improve their functionality by extending their flight duration and increasing their flight payload. Our solution to this problem is Automated Aerial Refueling (AAR) using stereo vision from stereo electro-optical and infrared cameras on a refueling tanker. To simulate a refueling scenario, we use ground vehicles to simulate a pseudo tanker and pseudo receiver UAV. Imagery of the receiver is collected by the cameras on the tanker and processed by a …
Estimating And Correcting Interference Fringes In Infrared Spectra In Infrared Hyperspectral Imaging, Ghazal Azarfar, Ebrahim Aboualizadeh, Nicholas Walter,, Simona Ratti, Camilla Olivieri, Alessandra Alessandra, Michael Nasse, Achim Kohler, Mario Giordano, Carol Hirschmugl
Estimating And Correcting Interference Fringes In Infrared Spectra In Infrared Hyperspectral Imaging, Ghazal Azarfar, Ebrahim Aboualizadeh, Nicholas Walter,, Simona Ratti, Camilla Olivieri, Alessandra Alessandra, Michael Nasse, Achim Kohler, Mario Giordano, Carol Hirschmugl
Physics Faculty Articles
Short-term acclimation response of individual cells of Thalassiosira weissflogii was monitored by Synchrotron FTIR imaging over the span of 75 minutes. The cells, collected from batch cultures, were maintained in a constant flow of medium, at an irradiance of 120 μmol m−2 s−1 and at 20 °C. Multiple internal reflections due to the micro fluidic channel were modeled, and showed that fringes are additive sinusoids to the pure absorption of the other components of the system. Preprocessing of the hyperspectral cube (x, y, Abs(λ)) included removing spectral fringe using an EMSC approach. Principal component analysis of the time series of …
Fabrication Of Infrared Photodetectors Utilizing Lead Selenide Nanocrystals, Justin Anthony Hill
Fabrication Of Infrared Photodetectors Utilizing Lead Selenide Nanocrystals, Justin Anthony Hill
Graduate Theses and Dissertations
Colloidal lead selenide and lead selenide / lead sulfide core/shell nanocrystals were grown using a wet chemical synthesis procedure. Absorbance and photoluminescence measurements were made to verify the quality of the produced nanocrystals. Absorbance spectra were measured at room temperature, while photoluminescence spectra were measured at 77 K. Organic ligands were exchanged for shorter ligands in order to increase the conductivity of the nanocrystals. Absorption and PL spectra for both core and core/shell nanocrystals were compared. Interdigital photodetector devices with varying channel widths were fabricated by depositing gold onto a glass substrate. Lead selenide nanocrystals were deposited onto these metallic …
High-Resolution Image Reconstruction From A Sequence Of Rotated And Translated Frames And Its Application To An Infrared Imaging System, Russell C. Hardie, Kenneth J. Barnard, John G. Bognar, Ernest E. Armstrong, Edward A. Watson
High-Resolution Image Reconstruction From A Sequence Of Rotated And Translated Frames And Its Application To An Infrared Imaging System, Russell C. Hardie, Kenneth J. Barnard, John G. Bognar, Ernest E. Armstrong, Edward A. Watson
Russell C. Hardie
Some imaging systems employ detector arrays that are not sufficiently dense to meet the Nyquist criterion during image acquisition. This is particularly true for many staring infrared imagers. Thus, the full resolution afforded by the optics is not being realized in such a system. This paper presents a technique for estimating a high-resolution image, with reduced aliasing, from a sequence of undersampled rotated and translationally shifted frames. Such an image sequence can be obtained if an imager is mounted on a moving platform, such as an aircraft. Several approaches to this type of problem have been proposed in the literature. …
Large Area Conformal Infrared Frequency Selective Surfaces, Jeffrey D'Archangel
Large Area Conformal Infrared Frequency Selective Surfaces, Jeffrey D'Archangel
Electronic Theses and Dissertations
Frequency selective surfaces (FSS) were originally developed for electromagnetic filtering applications at microwave frequencies. Electron-beam lithography has enabled the extension of FSS to infrared frequencies; however, these techniques create sample sizes that are seldom appropriate for real world applications due to the size and rigidity of the substrate. A new method of fabricating large area conformal infrared FSS is introduced, which involves releasing miniature FSS arrays from a substrate for implementation in a coating. A selective etching process is proposed and executed to create FSS particles from crossed-dipole and square-loop FSS arrays. When the fill-factor of the particles in the …
Broad Bandwidth, All-Fiber, Thulium-Doped Photonic Crystal Fiber Amplifier For Potential Use In Scaling Ultrashort Pulse Peak Powers, Alex Sincore
Electronic Theses and Dissertations
Fiber based ultrashort pulse laser sources are desirable for many applications; however generating high peak powers in fiber lasers is primarily limited by the onset of nonlinear effects such as self-phase modulation, stimulated Raman scattering, and self-focusing. Increasing the fiber core diameter mitigates the onset of these nonlinear effects, but also allows unwanted higher-order transverse spatial modes to propagate. Both large core diameters and single-mode propagation can be simultaneously attained using photonic crystal fibers. Thulium-doped fiber lasers are attractive for high peak power ultrashort pulse systems. They offer a broad gain bandwidth, capable of amplifying sub-100 femtosecond pulses. The longer …
Telescope Assembly Alignment Simulator Performance Optimization, Joshua G. Thompson, Brian Eney, Zaheer Ali, Bob Thompson
Telescope Assembly Alignment Simulator Performance Optimization, Joshua G. Thompson, Brian Eney, Zaheer Ali, Bob Thompson
STAR Program Research Presentations
The Telescope Assembly Alignment Simulator (TAAS) calibrates scientific instruments (SI’s) that are installed on the Stratospheric Observatory For Infrared Astronomy (SOFIA). An SI’s accuracy is directly dependent on the consistent performance of the TAAS, which has never been fully characterized. After designing various thermal and optical experiments to identify the current unknowns of TAAS, we now have a far better grasp on how the equipment behaves.
Commissioning Of The Asta Laser Lab With Uv Pulse Length Characterization, Daniel Kelley, Jeff Corbett
Commissioning Of The Asta Laser Lab With Uv Pulse Length Characterization, Daniel Kelley, Jeff Corbett
STAR Program Research Presentations
The Linac Coherent Light Source (LCLS) at SLAC depends on a photocathode electron gun to provide the linear accelerator with the raw material – electrons – used for making X-ray laser pulses. The photocathode used in the LCLS Injector is a clean copper plate in high vacuum. When the cathode is struck with high energy UV light, electrons are liberated from its surface and then accelerated down the linac with radio-frequency electric fields. These fast-moving bunches of electrons are directed through an undulator magnet to radiate X-ray light.
Although scientists have been using photocathode techniques at SLAC for 25 years, …
Infrared Tapered Slot Antennas Coupled To Tunnel Diodes, Louis A. Florence
Infrared Tapered Slot Antennas Coupled To Tunnel Diodes, Louis A. Florence
Electronic Theses and Dissertations
Tapered slot antennas (TSAs) have seen considerable application in the millimeter-wave portion of the spectrum. Desirable characteristics of TSAs include symmetric E- and H-plane antenna patterns, and broad non-resonant bandwidths. We investigate extension of TSA operation toward higher frequencies in the thermal infrared (IR), using a metal-oxide-metal diode as the detector. Several different infrared TSA design forms are fabricated using electronbeam lithography and specially developed thin-film processes. The angular antenna patterns of TSA-coupled diodes are measured at 10.6 micrometer wavelength in both E- and H-planes, and are compared to results of finite-element electromagnetic modeling using Ansoft HFSS. Parameter studies are …
Generation Of Mid-Ir Wavelengths, Deborah Robinson, Robert Hartsock, Kelly Gaffney
Generation Of Mid-Ir Wavelengths, Deborah Robinson, Robert Hartsock, Kelly Gaffney
STAR Program Research Presentations
Generation of mid-IR wavelengths
Deborah Robinson, Robert Hartsock, and Kelly Gaffney
Abstract
Research to determine basic molecular properties utilizing pump/probe experiments is an on going effort at SLAC. Here we have been given the task to generate mid-IR laser pulses and commission a mid-IR detector for said experiments and research. The mid-IR pulses will be used to probe the changes in molecular properties induced by exciting the electrons in molecules with visible pump pulses. In order to accomplish this, an optical parametric amplifier (OPA) has been set-up and aligned. The pump beam for the OPA is a 40 femtosecond 800nm …
Evanescent Wave Coupling Using Different Subwavelength Gratings For A Mems Accelerometer, Al-Aakhir A. Rogers
Evanescent Wave Coupling Using Different Subwavelength Gratings For A Mems Accelerometer, Al-Aakhir A. Rogers
USF Tampa Graduate Theses and Dissertations
A novel technique of coupling near-field evanescent waves by means of variable period subwavelength gratings (1.2 ìm and 1.0 ìm), using a 1.55 ìm infrared semiconductor laser is presented for the use of an optical MEMS accelerometer. The subwavelength gratings were fabricated on both glass and silicon substrates respectively.
Optical simulation of the subwavelength gratings was carried out to obtain the maximum coupling efficiency of the two subwavelength gratings; the grating thickness, grating width, and the grating separation were optimized. This was performed for both silicon and glass substrates.
The simulations were used to determine the total system noise, including …
Spectroscopic Analysis Of Tungsten Oxide Thin Films For Sensor Applications, Jose Luis Enriquez Carrejo
Spectroscopic Analysis Of Tungsten Oxide Thin Films For Sensor Applications, Jose Luis Enriquez Carrejo
Open Access Theses & Dissertations
The objective of this study is targeted toward improving the quality of pure tungsten oxide (WO3) for application to the detection of poisoning gases, especially of H2S. While pure WO3 is a recognized candidate for gas sensing, its characteristics are strongly dependent on the conditions and methods used in its deposition.
Samples of WO3 thin films analyzed in this work were grown on silicon and sapphire substrates using RF magnetron sputtering at a number of different substrate temperatures and Ar:O2 pressure ratios. The properties of the samples were investigated spectroscopically with the goal of determining how variations in the above …
Antenna-Coupled Infrared And Millimeter-Wave Detectors: Fabrication, Measurement And Optimization, Charles Middleton
Antenna-Coupled Infrared And Millimeter-Wave Detectors: Fabrication, Measurement And Optimization, Charles Middleton
Electronic Theses and Dissertations
Antenna-coupled detectors provide uncooled, cost-effective solutions for infrared and millimeter-wave imaging. This work describes the design, fabrication, measurement, and optimization of several types of antenna-coupled detectors for LWIR (8 - 12 µm) and 94 GHz radiation. Two types of millimeter-wave antenna-coupled detectors were fabricated and tested: a slot antenna coupled to a bolometer, and a patch antenna coupled to a SiC Schottky diode. Electromagnetic modeling of the antennas helped guide the design of antennas with better impedance matching to the detectors. Schottky diodes are discussed as detectors for millimeter-wave and infrared radiation, with the goal of increasing the cutoff frequency …
High-Resolution Image Reconstruction From A Sequence Of Rotated And Translated Frames And Its Application To An Infrared Imaging System, Russell C. Hardie, Kenneth J. Barnard, John G. Bognar, Ernest E. Armstrong, Edward A. Watson
High-Resolution Image Reconstruction From A Sequence Of Rotated And Translated Frames And Its Application To An Infrared Imaging System, Russell C. Hardie, Kenneth J. Barnard, John G. Bognar, Ernest E. Armstrong, Edward A. Watson
Electrical and Computer Engineering Faculty Publications
Some imaging systems employ detector arrays that are not sufficiently dense to meet the Nyquist criterion during image acquisition. This is particularly true for many staring infrared imagers. Thus, the full resolution afforded by the optics is not being realized in such a system. This paper presents a technique for estimating a high-resolution image, with reduced aliasing, from a sequence of undersampled rotated and translationally shifted frames. Such an image sequence can be obtained if an imager is mounted on a moving platform, such as an aircraft. Several approaches to this type of problem have been proposed in the literature. …