Open Access. Powered by Scholars. Published by Universities.®

Atomic, Molecular and Optical Physics Commons

Open Access. Powered by Scholars. Published by Universities.®

Nuclear Engineering

Institution
Keyword
Publication Year
Publication
Publication Type

Articles 1 - 26 of 26

Full-Text Articles in Atomic, Molecular and Optical Physics

Neutron Spectrum Unfolding From Activation Foils Irradiated In Gamble Ii Using Deuterated Polyethylene Anodes, Christopher J. Smith Mar 2024

Neutron Spectrum Unfolding From Activation Foils Irradiated In Gamble Ii Using Deuterated Polyethylene Anodes, Christopher J. Smith

Theses and Dissertations

Neutrons can cause irreparable harm to electronics, and experiments are needed to understand their effects fully. This work explores using pulsed power, which is low-cost compared to other sources, to create a useful neutron-rich environment. Deuterated polyethylene was used as anode and catcher material to generate the neutrons from the Deuterium-Deuterium (DD) fusion reaction. A simple, effective, and repeatable method was employed to directly cast deuterated polyethylene onto polyethylene sheets to fabricate the anode and catcher. The DD reactions were made by an ion beam-driven pulsed power generator, Gamble II, with the catcher located in the cathode. Zinc, copper, aluminum, …


Radiation Exposure Calibration Of The Al2o3:C With Radium-226 And Cesium-137 Using The Osl Method, Selma Tepeli Aydin Dec 2023

Radiation Exposure Calibration Of The Al2o3:C With Radium-226 And Cesium-137 Using The Osl Method, Selma Tepeli Aydin

All Theses

Optically stimulated luminescence (OSL) dosimetry was utilized to calibrate Al2O3:C powder dosimeters, available commercially as the nanoDot® from Landauer Inc., and compare the dosimeter response to radium-226 (226Ra) and cesium-137 (137Cs). The signal from the OSL was quantified using a microSTARii® OSL reader also produced by Landauer Inc. Dose-response curves were developed for 226Ra and 137Cs experiments (5 dosimeters each) at thirteen absorbed doses. Individual dosimeter response was tracked by serial number. Linear regression analysis was performed to determine if there were significant differences between the intercepts of the …


Enabling Rapid Chemical Analysis Of Plutonium Alloys Via Machine Learning-Enhanced Atomic Spectroscopy Techniques, Ashwin P. Rao Sep 2022

Enabling Rapid Chemical Analysis Of Plutonium Alloys Via Machine Learning-Enhanced Atomic Spectroscopy Techniques, Ashwin P. Rao

Theses and Dissertations

Analytical atomic spectroscopy methods have the potential to provide solutions for rapid, high fidelity chemical analysis of plutonium alloys. Implementing these methods with advanced analytical techniques can help reduce the chemical analysis time needed for plutonium pit production, directly enabling the 80 pit-per-year by 2030 manufacturing goal outlined in the 2018 Nuclear Posture Review. Two commercial, handheld elemental analyzers were validated for potential in situ analysis of Pu. A handheld XRF device was able to detect gallium in a Pu surrogate matrix with a detection limit of 0.002 wt% and a mean error of 8%. A handheld LIBS device was …


Regularized Heuristic Method For Activation Monitor Neutron Spectrum Unfolding, Nicholas J. Quartemont, James E. Bevins Oct 2021

Regularized Heuristic Method For Activation Monitor Neutron Spectrum Unfolding, Nicholas J. Quartemont, James E. Bevins

Faculty Publications

his paper describes an activation foil measurement based neutron flux unfolding method utilizing a heuristic optimization approach. A regularization parameter based on the differential neutron flux was introduced into the optimization cost function to remove large nonphysical oscillations in the unfolded neutron energy spectrum. The procedure was completed for two example case studies ranging from thermal energies up to 20 MeV demonstrating recovery of neutron flux energy information on radiation environments where a model was partially missing or there was a discrepancy in a reaction channel. The unfolded results provided a distribution of unfolded spectra that conformed to the activation …


Neutron Energy Tuning Assemblies For Nuclear Weapon Environment Applications At The National Ignition Facility, Nicholas J. Quartemont Sep 2021

Neutron Energy Tuning Assemblies For Nuclear Weapon Environment Applications At The National Ignition Facility, Nicholas J. Quartemont

Theses and Dissertations

An energy tuning assembly was developed to spectrally shape the National Ignition Facility deuterium-tritium fusion neutron source to a notional thermonuclear and prompt fission neutron spectrum to fulfill neutron source capability gaps. The experimental neutron environment was characterized with activation dosimetry, neutronics and covariance models, and unfolded to determine the as-fielded neutron spectrum. The first energy tuning assembly was demonstrated to create synthetic spectrally accurate post-detonation fission products, enhancing U.S. technical nuclear forensics capabilities. ATHENA, a second-generation energy tuning assembly, was also optimized to meet similar objectives, but the new platform neutron fluence efficiency was increased by a factor of …


Characterization Of A Boron-Loaded Deuterated Liquid Scintillator For Fast And Thermal Neutron Detection, Bryan V. Egner, Michael Febbraro, James E. Bevins Apr 2021

Characterization Of A Boron-Loaded Deuterated Liquid Scintillator For Fast And Thermal Neutron Detection, Bryan V. Egner, Michael Febbraro, James E. Bevins

Faculty Publications

The preparation and characterization of novel boron-loaded deuterated liquid scintillators (BLDLS) are presented for the first time to investigate the performance of a detector sensitive to both fast and thermal neutrons intended for future neutron spectroscopy measurements. Three deuterated toluene-based scintillation cocktails were produced, one without boron, one loaded with ortho-carborane (natural boron isotopic abundance), and one with 96 wt% 10B enriched ortho-carborane. General optical and material properties were analyzed to include the composition, density, index of refraction, photoluminescence emission spectra, and absorbance spectra in addition to the relative light yield, resolution, relative efficiency, and pulse-shape-discrimination performance for all three …


Lithium Compound Characterization Via Laser Induced Breakdown Spectroscopy And Raman Spectroscopy, James T. Stofel Mar 2021

Lithium Compound Characterization Via Laser Induced Breakdown Spectroscopy And Raman Spectroscopy, James T. Stofel

Theses and Dissertations

Industries such as lithium-ion battery producers and the nuclear industry community seek to produce and store lithium in pure chemical forms. However, these lithium compounds are reactive with the atmosphere and quickly degrade into less desirable forms. Therefore, industry desires a fast and effective quality control approach to quantify the ingrowth of these secondary lithium chemical forms. This research presents a novel approach using Laser-Induced Breakdown Spectroscopy (LIBS) and Raman spectroscopy in tandem to enhance lithium compound characterization beyond what is achieved by either technique alone. The resulting spectral data are aggregated using data fusion and analyzed using chemometrics for …


Development Of A Modular Mixed-Radiation Directional Rotating Scatter Mask Detection System, Bryan V. Egner, Darren E. Holland, Larry W. Burggraf, James E. Bevins Jan 2021

Development Of A Modular Mixed-Radiation Directional Rotating Scatter Mask Detection System, Bryan V. Egner, Darren E. Holland, Larry W. Burggraf, James E. Bevins

Faculty Publications

The ability to simultaneously identify the direction of both fast neutrons, above 1 MeV, and gamma rays using a light-weight system consisting of a single 1” EJ-309 organic liquid scintillator and a plastic Spartan rotating scatter mask (RSM) is demonstrated computationally through Monte Carlo simulations and validated with experimental measurements. Two sets of directional measurements were performed with an americium–beryllium source, emitting both neutrons and gamma rays. The RSM identified the direction of the source within one 10° rotational increment in the azimuthal and polar directions based on both the neutron and gamma-ray induced signals discriminated by charge integration pulse-shape …


Equations Of State For Warm Dense Carbon From Quantum Espresso, Derek J. Schauss Jan 2021

Equations Of State For Warm Dense Carbon From Quantum Espresso, Derek J. Schauss

Theses and Dissertations

Warm dense plasma is the matter that exists, roughly, in the range of 10,000 to 10,000,000 Kelvin and has solid-like densities, typically between 0.1 and 10 grams per centimeter. Warm dense fluids like hydrogen, helium, and carbon are believed to make up the interiors of many planets, white dwarfs, and other stars in our universe. The existence of warm dense matter (WDM) on Earth, however, is very rare, as it can only be created with high-energy sources like a nuclear explosion. In such an event, theoretical and computational models that accurately predict the response of certain materials are thus very …


Applications Of Portable Libs For Actinide Analysis, Ashwin P. Rao, John D. Auxier Ii, Dung Vu, Michael B. Shattan Jul 2020

Applications Of Portable Libs For Actinide Analysis, Ashwin P. Rao, John D. Auxier Ii, Dung Vu, Michael B. Shattan

Faculty Publications

A portable LIBS device was used for rapid elemental impurity analysis of plutonium alloys. This device demonstrates the potential for fast, accurate in-situ chemical analysis and could significantly reduce the fabrication time of plutonium alloys.


Measurement Of The 160Gd(P,N)160Tb Excitation Function From 4 18 Mev, Using A Stacked Foil Technique, Ryan K. Chapman Mar 2020

Measurement Of The 160Gd(P,N)160Tb Excitation Function From 4 18 Mev, Using A Stacked Foil Technique, Ryan K. Chapman

Theses and Dissertations

A stack of thin Gd, Ti, and Cu foils were irradiated with an 18 MeV proton beam at Lawrence-Berkeley National Laboratory's 88-Inch Cyclotron to investigate the 160Gd(p,n)160Tb nuclear reaction for nuclear forensics applications. This experiment will improve knowledge of 160Tb production rates, allowing 160Tb to be efficiently created in a foil stack consisting of other proton induced isotopes for forensics applications. A set of 15 measured cross sections between 4-18 MeV for 160Gd(p,n)160Tb were obtained using a stacked foil technique. The foil stack consisted of one stainless steel, one iron, fifteen gadolinium, …


Rapid Analysis Of Plutonium Surrogate Material Via Hand-Held Laser-Induced Breakdown Spectroscopy, Ashwin P. Rao Mar 2020

Rapid Analysis Of Plutonium Surrogate Material Via Hand-Held Laser-Induced Breakdown Spectroscopy, Ashwin P. Rao

Theses and Dissertations

This work investigated the capability of a portable LIBS device to detect and quantify dopants in plutonium surrogate alloys, specifically gallium, which is a common stabilizer used in plutonium alloys. The SciAps Z500-ER was utilized to collect spectral data from cerium-gallium alloys of varying gallium concentrations. Calibration models were built to process spectra from the Ce-Ga alloys and calculate gallium concentration from spectral emission intensities. Univariate and multivariate analysis techniques were used to determine limits of detection of different emission line ratios. Spatial mapping measurements were conducted to determine the device's ability to detect variations in gallium concentration on the …


Monte Carlo And Experimental Analysis Of A Novel Directional Rotating Scatter Mask Gamma Detection System, Julie V. Logan, Darren E. Holland, Larry W. Burggraf, Justin A. Clinton, Buckley E. O'Day Iii Dec 2019

Monte Carlo And Experimental Analysis Of A Novel Directional Rotating Scatter Mask Gamma Detection System, Julie V. Logan, Darren E. Holland, Larry W. Burggraf, Justin A. Clinton, Buckley E. O'Day Iii

Faculty Publications

Excerpt: This work demonstrates successful experimental operation of a prototype system to identify source direction which was modeled using a library of signals simulated using GEANT and a novel algorithm....


Quantitative Analysis Of Cerium-Gallium Alloys Using A Hand-Held Laser Induced Breakdown Spectroscopy Device, Ashwin P. Rao, Matthew Cook, Howard L. Hall, Michael B. Shattan Sep 2019

Quantitative Analysis Of Cerium-Gallium Alloys Using A Hand-Held Laser Induced Breakdown Spectroscopy Device, Ashwin P. Rao, Matthew Cook, Howard L. Hall, Michael B. Shattan

Faculty Publications

A hand-held laser-induced breakdown spectroscopy device was used to acquire spectral emission data from laser-induced plasmas created on the surface of cerium-gallium alloy samples with Ga concentrations ranging from 0–3 weight percent. Ionic and neutral emission lines of the two constituent elements were then extracted and used to generate calibration curves relating the emission line intensity ratios to the gallium concentration of the alloy. The Ga I 287.4-nm emission line was determined to be superior for the purposes of Ga detection and concentration determination. A limit of detection below 0.25%was achieved using a multivariate regression model of the Ga I …


Exploring Laser Induced Breakdown Spectroscopy (Libs) For Post-Detonation Nuclear Forensics Debris Analysis, Justin Knoll, Chad Schools, David Fobar Mar 2019

Exploring Laser Induced Breakdown Spectroscopy (Libs) For Post-Detonation Nuclear Forensics Debris Analysis, Justin Knoll, Chad Schools, David Fobar

Purdue Workshop on Nonproliferation: Technology and Approaches

In the unlikely but catastrophic event of a nuclear terrorist attack our government leadership will need reliable information to rapidly inform critical decisions. This research explores the use of Laser Induced Breakdown Spectroscopy (LIBS) as a potential analysis tool in the National Technical Nuclear Forensics process. The current state of post detonation nuclear forensics requires ground and air samples be collected and shipped to state-of-the-art laboratories for radiochemical analysis. The samples undergo many measurements and useable data is produced as these measurements are completed. This data flows back into the process to guide additional measurements and inform the process of …


An Exploration Of The Optical Detection Of Ionizing Radiation Utilizing Modern Optics Technology, Sean D. Fournier, Adam Hecht, Cassiano De Oliveira, Jeffrey B. Martin, Richard K. Harrison, Charles Potter Apr 2018

An Exploration Of The Optical Detection Of Ionizing Radiation Utilizing Modern Optics Technology, Sean D. Fournier, Adam Hecht, Cassiano De Oliveira, Jeffrey B. Martin, Richard K. Harrison, Charles Potter

Nuclear Engineering ETDs

Modern ultraviolet (UV) cameras, when combined with UV-transmitting lenses/filter arrangements, can be used to detect radiation dose in air. Ionizing radiation excites nitrogen molecules in ambient air, the resulting decay includes weak emission of ultraviolet photons. Previous work has proven this phenomenon is detectable using highly-sensitive electronically cooled cameras traditionally used in astronomy for low-background imaging. While the ability to detect the presence of radiation (i.e. qualitative measurement) has been demonstrated at Sandia National Laboratories, there are several challenges in correlating images to known dose-fields (quantitative measurement). These challenges include: a low signal to background ratio, interferences due to electronic …


Investigation Of 186Re Via Radiative Thermal-Neutron Capture On 185Re, David A. Matters, Andrew G. Lerch, A. M. Hurst, L. Szentmiklosi, J. J. Carroll, B. Detwiler, Zs. Revay, John W. Mcclory, Stephen R. Mchale, R. B. Firestone, B. W. Sleaford, M. Krticka, T. Belgya May 2016

Investigation Of 186Re Via Radiative Thermal-Neutron Capture On 185Re, David A. Matters, Andrew G. Lerch, A. M. Hurst, L. Szentmiklosi, J. J. Carroll, B. Detwiler, Zs. Revay, John W. Mcclory, Stephen R. Mchale, R. B. Firestone, B. W. Sleaford, M. Krticka, T. Belgya

Faculty Publications

Partial ��-ray production cross sections and the total radiative thermal-neutron capture cross section for the 185Re(n,��)186Re reaction were measured using the Prompt Gamma Activation Analysis facility at the Budapest Research Reactor with an enriched 185Re target. The 186Re cross sections were standardized using well-known 35Cl(n,��)36Cl cross sections from irradiation of a stoichiometric natReCl3 target. The resulting cross sections for transitions feeding the 186Re ground state from low-lying levels below a cutoff energy of Ec=746keV were combined with a modeled probability of ground-state feeding from levels above E …


Coupling Nuclear Induced Phonon Propagation With Conversion Electron Mössbauer Spectroscopy, Michael J. Parker Jun 2015

Coupling Nuclear Induced Phonon Propagation With Conversion Electron Mössbauer Spectroscopy, Michael J. Parker

Theses and Dissertations

Mössbauer spectroscopy is a very sensitive measurement technique (10-8 eV) which prompted motivation for the experiment described in this thesis. Namely, can a sensitive detection system be developed to detect nuclear recoils on the order of 10 to 100 of eVs? The hypothesis that this thesis tests is: Nuclear induced phonon bursts caused by Rutherford scattered alphas, decayed from 241Am, in a type-310 stainless steel material can couple with 7.3 keV conversion electron Mössbauer events at the other end of the material which will have a statistically significant effect on a Mössbauer spectrum. The phonon bursts produced by …


Doube-Pulse Laser-Induced Breakdown Spectroscopy Of Multi-Element Sample Containing Low- And High-Z Analytes, Patrick J. Skrodzki, Jason R. Becker, Prasoon K. Diwakar Ph. D., Sivanandan S. Harilal Ph. D., Ahmed Hassanein Ph. D. Aug 2014

Doube-Pulse Laser-Induced Breakdown Spectroscopy Of Multi-Element Sample Containing Low- And High-Z Analytes, Patrick J. Skrodzki, Jason R. Becker, Prasoon K. Diwakar Ph. D., Sivanandan S. Harilal Ph. D., Ahmed Hassanein Ph. D.

The Summer Undergraduate Research Fellowship (SURF) Symposium

Laser-induced breakdown spectroscopy (LIBS) is a portable, remote, non-invasive analytical technique which effectively distinguishes neutral and ionic species for a range of low- to high-Z elements in a multi-element target. Subsequently, LIBS holds potential in special nuclear material (SNM) sensing and nuclear forensics requiring minimal sample preparation and detecting isotopic shifts which allows for differentiation in SNM (namely U) enrichment levels. Feasible applications include not only nonproliferation and homeland security but also nuclear fuel prospecting and industrial safeguard endorsement. Elements of higher mass with complex atomic structures, such as U, however, result in crowded emission spectra with LIBS, and characteristic …


Double-Pulse Nd:Yag-Co2 Libs Excitation For Bulk And Trace Analytes, Jason R. Becker, Patrick Skrodzki, Prasoon Diwakar, Sivanandan Harilal, Ahmed Hassanein Aug 2014

Double-Pulse Nd:Yag-Co2 Libs Excitation For Bulk And Trace Analytes, Jason R. Becker, Patrick Skrodzki, Prasoon Diwakar, Sivanandan Harilal, Ahmed Hassanein

The Summer Undergraduate Research Fellowship (SURF) Symposium

Laser-induced breakdown spectroscopy [LIBS] is a commonly used technique for multi-element analyses for various applications such as space exploration, nuclear forensics, environmental analysis, process monitoring. The advantages of the LIBS technique include robustness, ease of use, field portability, and real-time, non-invasive multi-element analyses. However, in comparison to other lab based analytical techniques, it suffers from low precision and low sensitivity. In order to overcome these drawbacks, various approaches have been used, including double-pulse LIBS [DPLIBS]. Typically, various wavelength combinations of two Nd: yttrium aluminum garnet [YAG] lasers have been used for DPLIBS. However, the use of long wavelength (CO2 …


Structure Studies On Lanthanide Technetium Pyrochlores As Prospective Host Phases To Immobilize 99- Technetium And Fission Lanthanides From Effluents Of Reprocessed Used Nuclear Fuels, Thomas Hartmann, Ariana Alaniz Apr 2011

Structure Studies On Lanthanide Technetium Pyrochlores As Prospective Host Phases To Immobilize 99- Technetium And Fission Lanthanides From Effluents Of Reprocessed Used Nuclear Fuels, Thomas Hartmann, Ariana Alaniz

Festival of Communities: UG Symposium (Posters)

We performed a systematic investigation of the incorporation of 99Tc into pyrochlore oxide structures, Ln2Tc2O7, where Ln represents trivalent lanthanide Ln3+ cations, while 99Tc is atetravalent, Tc4+, metal cation. Pyrochlore compounds are high-melting temperature oxides and are recognized for their durability. Our goal in this preliminary study is to characterize and quantify the range of stability of the lanthanum technetium pyrochlore oxide phase. Hereby, powder X-ray diffraction (XRD) and Rietveld analysis were used to determine and characterize the crystalline phase content with high accuracy, and scanning electron microscopy (SEM) was used to characterize the microstructure and homogeneity of the synthesized …


Classification Of Battlespace Detonations From Temporally Resolved Mutli-Band Imagery And Mid-Infrared Spectra, Anthony N. Dills Mar 2005

Classification Of Battlespace Detonations From Temporally Resolved Mutli-Band Imagery And Mid-Infrared Spectra, Anthony N. Dills

Theses and Dissertations

The classification of battlespace detonations, specifically the determination of munitions type and size using temporal and spectral features, has been studied using near-infrared (NIR) and multi-color visible wavelength imagers. Key features from the time dependence of fireball size are identified for discriminating various types and sizes of detonation flashes. The five classes include three weights of trinitrotoluene (TNT) and two weights of an enhanced mixture, all of which are uncased and detonated with 10% C4. Using Fisher linear discriminant techniques, features are projected onto a line such that the projected points are maximally clustered for the different classes of detonations. …


Detection Of Special Nuclear Material With High Purity Germanium (Hpge) And Mercuric Iodide (Hgi2) Gamma Detectors, Michael B. Nelson Mar 2003

Detection Of Special Nuclear Material With High Purity Germanium (Hpge) And Mercuric Iodide (Hgi2) Gamma Detectors, Michael B. Nelson

Theses and Dissertations

The Defense Threat Reduction Agency (DTRA) contracted for two gamma radiation detectors: mercuric iodide (HgI2) and electromechanically cooled (EMC) high purity germanium (HPGe) to support arms control inspection efforts. This project investigated whether these detectors could measure the quality and quantity of special nuclear material (SNM), particularly Pu-239 for the treaty verification mission. The project investigated two areas of detector capabilities: 1) HgI2 and HPGe detector performance necessary to characterize the quality of plutonium and the presence of shielding materials and 2) HgI2 and EMC HPGe detector performance degradation by high noise levels and EMC HPGe …


Investigation Of The Corrosion Of Steel By Lead-Bismuth Eutectic (Lbe) Using Scanning Electron Microscopy And X-Ray Photoelectron Spectroscopy, Daniel Koury Dec 2002

Investigation Of The Corrosion Of Steel By Lead-Bismuth Eutectic (Lbe) Using Scanning Electron Microscopy And X-Ray Photoelectron Spectroscopy, Daniel Koury

UNLV Theses, Dissertations, Professional Papers, and Capstones

Lead Bismuth Eutectic (LBE) has been proposed for use in programs for accelerator transmutation of waste. LBE is the leading candidate material as a spallation target and an option for the sub-critical blanket coolant. The corrosion of 316 and 316L stainless steels by LBE has been studied using UNLV's facilities for Scanning Electron Microscopy (SEM) and X-ray Photoelectron Spectroscopy (XPS). We have compared exposed and unexposed samples and studied the differences. Some amount of surface contamination is present on the samples and has been removed by ionbeam etching. The unexposed samples reveal typical stainless steel characteristics: a chromium oxide passivation …


Construction And Testing Of A Neutron And Gamma Spectrometry System Using Pulse Shape Discrimination With An Organic Scintillator, Robert S. Pope Mar 1993

Construction And Testing Of A Neutron And Gamma Spectrometry System Using Pulse Shape Discrimination With An Organic Scintillator, Robert S. Pope

Theses and Dissertations

The goal of this thesis was to construct and test a neutron detector to measure the energy spectrum of 1 to 14-MeV neutrons in the presence of gammas. A spectrometer based on the process of pulse shape discrimination (PSD) was constructed, in which the scintillator NE-213 was used. The primary neutron/ gamma sources used were 78-mCi and 4.7-Ci 239PuBe sources, while 4.7-µCi and 97.6-µCi 22Na gamma sources were used for energy calibration and additional testing of the detector. Proton recoil spectra and Compton electron spectra were unfolded with the neutron and gamma unfolding code FORIST to generate the …


Design And Construction Of A Channel Electron Multiplier Based Mossbauer Spectroscopy System, Daniel J. Robbins Mar 1992

Design And Construction Of A Channel Electron Multiplier Based Mossbauer Spectroscopy System, Daniel J. Robbins

Theses and Dissertations

A channel electron multiplier (cem) detector system was designed and built to provide a signal to a Mossbauer spectroscopy system in an effort to obtain a better signal-to-noise ratio than achievable with a proportional counter system. Three cems are contained in a vacuum chamber built using standard components. Gamma, rays of 14.4-keV energy from a 57Co source enter from outside the chamber through a window and are absorbed by an 57Fe target near the cems. The target emits internal conversion electrons which are collected by the cems and a Mossbauer spectrometer collects the signal. The system produces a …