Open Access. Powered by Scholars. Published by Universities.®

Physics Commons™

Open Access. Powered by Scholars. Published by Universities.®

University of South Carolina

Discipline
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 481 - 489 of 489

Full-Text Articles in Physics

Tip-Angle-Dependent Magnetic Relaxation In Superfluid 3he, Richard A. Webb Mar 1978

Tip-Angle-Dependent Magnetic Relaxation In Superfluid 3he, Richard A. Webb

Faculty Publications

Using a pulsed superconducting-quantum-interference-device (SQUID) NMR technique, relaxation of the longitudinal magnetization in superfluid 3He has been measured in magnetic fields of 31, 102, 180, and 306 Oe in the pressure range 16-26 bar. It is observed that in both superfluid phases there is a temperature-dependent, well-defined spin-tipping angle, θc, for which the relaxation of the magnetization changes from an exponential to a nonexponential behavior.


Ferromagneticlike Resonance Behavior In Superfluid 3he-B, Richard A. Webb Oct 1977

Ferromagneticlike Resonance Behavior In Superfluid 3he-B, Richard A. Webb

Faculty Publications

Nonlinear cw NMR behavior, similar to that observed on ferromagnets at high rf powers, has been observed in superfluid 3He-B using a superconducting quantum interference device (SQUID) magnetometer in fields of 31, 102, 180, and 308 Oe and at a pressure of 21 bar. It is observed that beyond some threshold value of the transverse H1 field the z component of magnetization anomalously decreases and is followed by a rapid increase back to the normal resonance curve as the frequency of the H1 field is swept through resonance.


Measurement Of The Difference Between The Dynamic Nmr And Static Susceptibilites Of Superfluid 3he-B Using An Rf-Biased Superconducting Quantum-Interference Device, Richard A. Webb May 1977

Measurement Of The Difference Between The Dynamic Nmr And Static Susceptibilites Of Superfluid 3he-B Using An Rf-Biased Superconducting Quantum-Interference Device, Richard A. Webb

Faculty Publications

The temperature-dependent susceptiblity of superfluid 3He-B has been measured both statically and via a pulse technique in a field of 309 G using an rf-biased superconducting quantum-interference device (SQUID). In the pressure range 26.5 to 18 bar, the dynamic NMR susceptiblity agrees qualitatively with the theoretical weak-coupling predictions for the Balian-Werthamer state. However, the static susceptiblity, measured using the same rf-biased SQUID and detection system, is significantly smaller thatn the dynamic susceptibility.


Relaxation Of The Wall-Pinned Magnetization Ringing Mode In Superfluid 3he-B, Richard A. Webb, R. E. Sager, J. C. Wheatley Oct 1975

Relaxation Of The Wall-Pinned Magnetization Ringing Mode In Superfluid 3he-B, Richard A. Webb, R. E. Sager, J. C. Wheatley

Faculty Publications

Observations of the wall-pinned mode in 3He-B allow new magnetic relaxation phenomena to be studied. Excepting the quantitative value of the zero-time ringing frequency, comparison of experiment with theory is satisfactory, including a linear dependence of the square of the ringing period on time and a square-root singularity near Tc in the relaxation parameter.


Nonlinear Parallel Ringing Of Magnetization In Superfluid 3he, Richard A. Webb, R. E. Sager, J. C. Wheatley Oct 1975

Nonlinear Parallel Ringing Of Magnetization In Superfluid 3he, Richard A. Webb, R. E. Sager, J. C. Wheatley

Faculty Publications

Experiments based on an analogy to the ac Josephson effect have shown in both 3He-A and 3He-B that a pairing theory of the superfluidity of 3He is essentially correct. Additional observations of parallel ringing are not in agreement with the simple "pendulum models" used to describe nonlinear dynamic magnetic effects.


Relationship Between The Linear Ringing Frequencies In 3he-A And 3he-B Near The Polycritical Point, Richard A. Webb, R. E. Sager, J. C. Wheatley Sep 1975

Relationship Between The Linear Ringing Frequencies In 3he-A And 3he-B Near The Polycritical Point, Richard A. Webb, R. E. Sager, J. C. Wheatley

Faculty Publications

New measurements of parallel ringing in a quasi-ideal geometry for 3He-B near the temperature and pressure of the polycritical point suggest fB2/fA2∼5/2, where fB and fA are the linear parallel-ringing frequencies at a given temperature near Tc. This result approaches the prediction of theory using the Anderson-Brinkman-Morel and Balian-Werthamer states to describe 3He-A and 3He-B, respectively, and hence the results of Osheroff at melting pressure, but disagrees with earlier observations at pressures near the polycritical point.


Experiments On Dynamic Parallel Magnetism In Superfluid 3he, Richard A. Webb, R. L. Kleinberg, J. C. Wheatley Jul 1974

Experiments On Dynamic Parallel Magnetism In Superfluid 3he, Richard A. Webb, R. L. Kleinberg, J. C. Wheatley

Faculty Publications

Observations are reported of the ringing of parallel magnetization in superfluid 3He when an incremental magnetic field parallel to a steady field is suddenly turned off.


Observation Of A Second-Order Phase Transition And Its Associated P - T Phase Diagram In Liquid He3, Richard A. Webb, T. J. Greytak, R. T. Johnson, J. C. Wheatley Feb 1973

Observation Of A Second-Order Phase Transition And Its Associated P - T Phase Diagram In Liquid He3, Richard A. Webb, T. J. Greytak, R. T. Johnson, J. C. Wheatley

Faculty Publications

A specific-heat "discontinuity" is observed in liquid He3 from 241 lb/in.2 to the melting pressure in the temperature range 2-3 mK.


Magnetic And Thermometric Properties Of Na3[Ce(C7h3no4)3] ·15h2o In The Millikelvin Range, Richard A. Webb, J. C. Wheatley Oct 1972

Magnetic And Thermometric Properties Of Na3[Ce(C7h3no4)3] ·15h2o In The Millikelvin Range, Richard A. Webb, J. C. Wheatley

Faculty Publications

Measurements of the 16-Hz susceptibility of a powdered Na3[Ce(C7H3NO4)3] · 15H2O (CDP) sample, in the shape of a right-circular cylinder with diameter equal to height, have been made as a function of the Johnson noise temperature TJ of a resistor in the range 2 to 20 mK. Pure liquid 3He was used for thermal contact between the CDP and the noise thermometer in a demagnetization cell. The results are compared with similar data for cerium magnesium nitrate (CMN). CDP appears, like CMN, to have an anomalously …