Open Access. Powered by Scholars. Published by Universities.®
- Discipline
- Keyword
-
- Electrochemistry (14)
- Electrochemical impedance spectroscopy (11)
- Cyclic voltammetry (9)
- Electrocatalysis (9)
- Electrochemical sensor (8)
-
- Electrochemiluminescence (7)
- Hydrogen peroxide (6)
- Raman spectroscopy (6)
- Sensor (6)
- Biosensor (5)
- Corrosion (5)
- Dopamine (5)
- Glucose oxidase (5)
- Gold nanoparticles (5)
- Modified electrode (5)
- Pyridine (5)
- SERS (5)
- Carbon nanotubes (4)
- Electrochemical analysis (4)
- Electrochemical detection (4)
- Electrochemical interface (4)
- Ethanol (4)
- Glassy carbon electrode (4)
- Glucose (4)
- Graphene (4)
- In vivo (4)
- Oxygen reduction reaction (4)
- Surface enhanced Raman spectroscopy (4)
- Adsorption (3)
- Cathode (3)
Articles 121 - 150 of 285
Full-Text Articles in Analytical Chemistry
Electrochemical H2O2 Sensor Based On The Co-Immobilization Of Phosphmolybdic Acid And Graphene On Pedot Film Electrode With Nafion, Hao-Xian Zhou, Jun-Ming Zhang, Zhi-Yu Qu, Pan-Yu Zhang, You-Jun Fan
Electrochemical H2O2 Sensor Based On The Co-Immobilization Of Phosphmolybdic Acid And Graphene On Pedot Film Electrode With Nafion, Hao-Xian Zhou, Jun-Ming Zhang, Zhi-Yu Qu, Pan-Yu Zhang, You-Jun Fan
Journal of Electrochemistry
With a glassy carbon electrode (GCE) as the substrate, the poly(3,4-ethylenedioxythiophene) (PEDOT) film electrode was prepared through the electrochemical polymerization method, then a novel non-enzymatic electrochemical H2O2 sensor was fabricated by co-immobilizing phosphomolybdic acid and graphene with Nafion on the PEDOT/GCE electrode. The modified electrodes were characterized by scanning electron microscopy (SEM), while the responsive properties of the sensor to H2O2 were investigated by cyclic voltammetry and chronoamperometry. The results demonstrated that, under the optimized conditions, the sensor exhibited good electrocatalytic performance for H2O2 reduction. The current response of the sensor …
Adsorption Behavior Of Rhodamine 6g On Silver Surfaces Studied By Electrochemical Surface-Enhanced Raman Spectroscopy, Chan-Juan Chen, Cheng Zong, Guo-Kun Liu, Bin Ren
Adsorption Behavior Of Rhodamine 6g On Silver Surfaces Studied By Electrochemical Surface-Enhanced Raman Spectroscopy, Chan-Juan Chen, Cheng Zong, Guo-Kun Liu, Bin Ren
Journal of Electrochemistry
Rhodamine 6G (R6G) is one of the most common probe molecules employed in single molecule surface-enhanced Raman spectroscopy (SM-SERS). The study in adsorption behavior of R6G will help understand the interactions between R6G and surface. In this paper, we used electrochemical surface-enhanced Raman spectroscopy (SERS) to study the potential-dependent adsorption behavior of R6G on silver electrodes. Our results show that when the potential moved negatively, the orientation of R6G on silver surface changed from vertical to inclined adsorption. This result indicates that the abnormal SM-SERS spectra of R6G observed in the former SM-SERS studies from other research groups are due …
Electrochemical Detection Of Hydrogen Peroxide At Aunps Modified Electrode Using P-Hydroxyphenylboronic Acid As A Precursor, Chun-Yan Wang, Xiao-Qiu Liu, Ying-Xin Qi
Electrochemical Detection Of Hydrogen Peroxide At Aunps Modified Electrode Using P-Hydroxyphenylboronic Acid As A Precursor, Chun-Yan Wang, Xiao-Qiu Liu, Ying-Xin Qi
Journal of Electrochemistry
We developed a new method for electrochemical detection of hydrogen peroxide (H2O2) based on boronate oxidation of p-hydroxyphenylboronic acid. This method using p-aminophenol which is produced from the reaction of H2O2 and p-aminophenylboronic acid as a well electrochemical probe, combined with a gold nanoparticles (AuNPs) modified electrode for an indirect detection of H2O2. Because of the large surface area and enhanced electrocatalytic behavior by the AuNPs modified electrode, the detection sensitivity was improved. The method could detect H2O2 in the concentration range of 1 ~ 100 …
Fabrication Of Riboflavin Electrochemical Sensor Based On Au Nanoparticles/Polydopamine/Carbon Nanotubes Modified Glassy Carbon Electrode, Hua-Ping Peng, Mei-Ling Yu, Xin Liu, Pan Liu, Wei Chen, Ai-Lin Liu, Xin-Hua Lin
Fabrication Of Riboflavin Electrochemical Sensor Based On Au Nanoparticles/Polydopamine/Carbon Nanotubes Modified Glassy Carbon Electrode, Hua-Ping Peng, Mei-Ling Yu, Xin Liu, Pan Liu, Wei Chen, Ai-Lin Liu, Xin-Hua Lin
Journal of Electrochemistry
A novel electrochemical platform for the high sensitivity detection of riboflavin was constructed by Au nanoparticles/polydopamine/carbon nanotubes (Au-PDA-MWCNTs) nanocomposite modified glassy carbon electrode. The Au-PDA-MWCNTs nanocomposite was synthesized by in situ reduction method. The characteristics of the as-prepared Au-PDA-MWCNTs nanocomposite modified electrodes were investigated by using UV-Vis spectroscopy, scanning electron microscopy (SEM) and electrochemical methods. Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were used to study the electrochemical behavior of riboflavin (RF) at Au-PDA-MWCNTs nanocomposite modified electrodes. The results demonstrated that the present electrochemical sensor exhibited a wide linear range from 5×10-9 mol•L-1to 1×10-5 mol•L …
Intercalation Of Clo4- Into Hopg Investigated By Ec-Stm, Xiao-Yan Hu, Alice Aliwowe, Jia-Wei Yan, Bing-Wei Mao
Intercalation Of Clo4- Into Hopg Investigated By Ec-Stm, Xiao-Yan Hu, Alice Aliwowe, Jia-Wei Yan, Bing-Wei Mao
Journal of Electrochemistry
The electrochemical intercalation and surface morphology of highly oriented pyrolytic graphite (HOPG) electrode in 2 mol⋅L-1 HClO4 were studied by in situ scanning tunneling microscopy (STM) and cyclic voltammetry (CV). Based on the step-height changes observed before and after the intercalation, the effects of different step sites on intercalation are compared. The feasibility, reversibility and speed of intercalation are discussed. The intercalation ofClO4- into HOPG can be divided into three types depending on the number of graphite layers at the step site: When the layers of graphite are more than three, the intercalation becomes feasible; when …
Application Of Pd/Graphene Modified Electrode In The Detection Of 4-Chlorophenol, Peng Shi, Bo-Xuan Wang, Quan-Lin Song, Hui Wang, Xin Liu, Zhao-Yong Bian
Application Of Pd/Graphene Modified Electrode In The Detection Of 4-Chlorophenol, Peng Shi, Bo-Xuan Wang, Quan-Lin Song, Hui Wang, Xin Liu, Zhao-Yong Bian
Journal of Electrochemistry
The Pd/graphene composites were synthesized by a modified Hummers method and NaBH4 reduction process, and then were characterized using XRD, SEM, XPS, and TEM. The Pd/graphene modified glassy carbon electrode (Pd/graphene/GCE) was prepared based on this method. Cyclic voltammetry was used to study the optimum operation conditions for the 4-chlorophenol detection. It was shown that the surface of the graphene was smooth and Pd nanoparticles were uniformly dispersed on graphene. The average particle size was calculated to be 6.5 ± 0.05 nm. These nanoparticles exhibited high catalytic activity and sensitivity toward chlorophenols. PBS with a concentration of 0.1 mol·L-1 …
Effect Of Adsorption Potential On Co Oxidation At Au@Pt Nanoparticles Electrodes, A Surface Enhanced Raman Spectroscopic Study, Pu Zhang, Yi Wei, Yong-Li Zheng, Yan-Xia Chen, Zhong-Qun Tian
Effect Of Adsorption Potential On Co Oxidation At Au@Pt Nanoparticles Electrodes, A Surface Enhanced Raman Spectroscopic Study, Pu Zhang, Yi Wei, Yong-Li Zheng, Yan-Xia Chen, Zhong-Qun Tian
Journal of Electrochemistry
The adsorption/oxidation of CO on the 55 nm [email protected] nm Pt nanoparticles electrode in both potentiodynamic and potentiostatic modes were investigated by surface enhanced Raman spectroscopy in a thin layer electrochemical flow cell under controlled mass transport, with the aim of clarifying the origin CO oxidation at lower electrode potentials (in current pre-wave region of corresponding cyclic voltammograms). Our results demonstrated that the CO oxidation kinetics differed significantly from the three kinds of different CO adsorption history, with almost no CO oxidation current in the pre-peak potential region after 0.35 VRHE CO adsorption with or without subsequent holding the …
Broadband Sum-Frequency Generation Spectroscopic Invstigations Of Thiocyanate On Polycrystalline Au Electrode In Alkaline Solutions, Mei Xu, Jing-Jing Wang, Zhi-Chao Huangfu, Ng Ying Wa, Yu-Han He, Zhao-Hui Wang
Broadband Sum-Frequency Generation Spectroscopic Invstigations Of Thiocyanate On Polycrystalline Au Electrode In Alkaline Solutions, Mei Xu, Jing-Jing Wang, Zhi-Chao Huangfu, Ng Ying Wa, Yu-Han He, Zhao-Hui Wang
Journal of Electrochemistry
Broadband sum frequency generation (BB-SFG) spectroscopy has been used to investigating the potential-dependent adsorption behaviors of thiocyanate ions on polycrystalline Au electrode in alkaline solutions. During the positive scan, a change in the Stark slope (dωC-N/dE) for C—N stretching mode can be observed in the range of -1.1 V ~ 0.2 V (vs. SCE), which implies that the orientation of adsorbed thiocyanate ions at Au electrode surface changes from N-bound (dωC-N/dE=45 cm-1·V-1) form to S-bound (dωC-N/dE = 16.2 cm-1·V-1 …
Novel Dna Electrochemical Biosensor For K-Ras Point Mutation Detection Based On Dna Polymerase I, Li-Qing Lin, Cheng-Fei Zhao, Zhou-Qian Jiang, Shao-Huang Weng, Xiao-Lan Xie, Xin-Hua Lin
Novel Dna Electrochemical Biosensor For K-Ras Point Mutation Detection Based On Dna Polymerase I, Li-Qing Lin, Cheng-Fei Zhao, Zhou-Qian Jiang, Shao-Huang Weng, Xiao-Lan Xie, Xin-Hua Lin
Journal of Electrochemistry
In this article, we developed a novel DNA electrochemical sensor for obtaining a current-time curve based on DNA polymerase I. The capture probes were fixed on the Au electrode by Au interacting with -SH, and then hybridized with the K-ras mutant target DNA as far as one base before the mutation site. After hybridizing the K-ras mutant or wild target DNA, the resulting assembly reacted with the dUTP-biotin in the presence of DNA polymerase I. Then avidin-HRP combined the dUTP-biotin on the electrode. The proposed electrode was applied for detection in TMB solution by electrochemical technology. The experimental results showed …
A Novel Nitrite Sensing Electrode Based On Au/Fe3O4/Chitosan Nanocomposite, Ying Dong, Yong Wang, Huan-Huan Xing, Jian-Ying Qu
A Novel Nitrite Sensing Electrode Based On Au/Fe3O4/Chitosan Nanocomposite, Ying Dong, Yong Wang, Huan-Huan Xing, Jian-Ying Qu
Journal of Electrochemistry
A novel nitrite sensing electrode based on gold nanoparticles and iron oxides (Fe3O4) magnetic nanoparticles was fabricated with chitosan as the protective film on glassy carbon matrix. Experiment results showed that the sensing electrode exhibited good electrocatalytic activity toward oxidation of nitrite, and the oxidation peak current increased linearly with the concentration of nitrite varying from 5.0×10-6 to 2.0×10-3 mol·L-1 (R=0.9996) with a detection limit of 7.1×10-7 mol·L-1 (S/N=3). The sensing electrode exhibited good sensitivity, selectivity and repeatability.
Electrochemiluminescence Assay Based On Bipolar Electrode For Bioanalysis, Mei-Sheng Wu, Jing-Juan Xu, Hong-Yuan Chen
Electrochemiluminescence Assay Based On Bipolar Electrode For Bioanalysis, Mei-Sheng Wu, Jing-Juan Xu, Hong-Yuan Chen
Journal of Electrochemistry
Bipolar electrodes (BPEs) are electronic conductors which are usually embedded into microchannels. The potential difference at the BPE/solution interface is obtained by applying a voltage at the two ends of the microchannel. When it reaches a critical value, the redox reaction takes place at both poles of the BPE simultaneously. Compared with other detection methods, the electrochemiluminescence (ECL) platform based on BPE possesses the advantages of concentration enrichment, high sensitivity, low cost, portable sensor system, no need for a light source, which is quite suitable for bioanalysis. This paper reviews the ECL-BPE strategy for bioanalysis and proposes the future research …
Electrochemiluminescence Biosensors Based On The Signal Amplification Of Co-Reactants, Hai-Jun Wang, Li-Juan Xiao, Ying He, Xin-Ya Jiang, Ya-Li Yuan, Ying Zhuo, Ya-Qin Chai, Ruo Yuan
Electrochemiluminescence Biosensors Based On The Signal Amplification Of Co-Reactants, Hai-Jun Wang, Li-Juan Xiao, Ying He, Xin-Ya Jiang, Ya-Li Yuan, Ying Zhuo, Ya-Qin Chai, Ruo Yuan
Journal of Electrochemistry
Using co-reactants to enhance the luminous efficiency of luminophores is a common, convenient and effective method in the construction of the electrochemiluminescence (ECL) biosensors. However, the different methods of introducing co-reactants in the construction of the ECL biosensors will bring different amplification effects. In this review, several signal amplification methods through co-reactants are summarized: 1) Adding the co-reactants directly into the detection solution; 2) Immobilizing the co-reactants onto the electrode surface; 3) Using enzymatic reaction to generate co-reactants in situ around the electrode surface. And then, the outlook of the ECL signal amplification strategy is proposed on those bases.
Sensitive Detection Of Hydroxyl Radical Based On Silver-Enhanced Gold Nanoparticle Label, Yan Yang, Peng Yu, Xiao-Hua Zhang, Jin-Hua Chen
Sensitive Detection Of Hydroxyl Radical Based On Silver-Enhanced Gold Nanoparticle Label, Yan Yang, Peng Yu, Xiao-Hua Zhang, Jin-Hua Chen
Journal of Electrochemistry
A novel DNA-based electrochemical sensor has been successfully constructed for sensitive detection of hydroxyl radical (·OH) based on the silver-enhanced gold nanoparticle label. Thiolated DNA1 was firstly immobilized on the gold electrode through Au—S bonds. The ·OH generated from Fenton reaction could induce serious oxidative damage of the DNA1 layer on the electrode surface. Then DNA2-functionalized gold nanoparticles (DNA2-AuNPs) were linked on the electrode through the hybridization between DNA2 and undamaged DNA1. Based on the catalytic reduction of silver ion by AuNPs, a silver layer was formed on the surface of AuNPs. The quantitative assay of ·OH was carried out …
A Multi-Channel Electrochemical Immunosensing System With Polyhrp-Based Signal Amplification For The Detection Of Tumor Markers, Wang-Ping Deng, Yan-Zhi Dou, Jing Su, Lin Hao, Shi-Ping Song, Chun-Hai Fan
A Multi-Channel Electrochemical Immunosensing System With Polyhrp-Based Signal Amplification For The Detection Of Tumor Markers, Wang-Ping Deng, Yan-Zhi Dou, Jing Su, Lin Hao, Shi-Ping Song, Chun-Hai Fan
Journal of Electrochemistry
We have developed a multi-channel electrochemical immunosensing system for the detection of α-fetoprotein (AFP). The sensing system consisted of carbon screen-printed electrode (SPCE) arrays and polyHRP-based signal amplification probes. AFP antigens could bind to both capture antibodies immobilized on electrode arrays ant detection antibodies (anti-AFP IgG developed in rabbit). The anti-rabbit IgG conjugated to poly-horseradish peroxidase were used as a signaling probe to bind to the immuno-complex. The current signals were harvested by a home-made multi-channels electrochemical detector. AFP could be detected in the concentration ranges of 64 pg·mL-1 ~ 250 ng·mL-1. The detection limit was as …
Fabrication And Application Of Cytochrome P450 Electrochemcial Biosensor In Drug Metabolism, Xuan Xu, Ju-Sheng Lu, Song-Qin Liu
Fabrication And Application Of Cytochrome P450 Electrochemcial Biosensor In Drug Metabolism, Xuan Xu, Ju-Sheng Lu, Song-Qin Liu
Journal of Electrochemistry
The process of drug metabolism plays an important role in drug efficacy and toxicity in vivo. Thus, the development of cheap, continent, rapid and high-throughput method for drug metabolism studies has great guiding significance for the design of new drugs, the determination of drug dosage and the detection of clinical drugs. Since the key role played by Cytochrome P450 (CYP450) in phase-I drug reaction, the constructed CYP450 enzyme biosensor can be used for the initial screening of drugs. It is found that the replacement of coenzyme NADPH with an electrode is to provide two electrons demanded in the catalytic reaction. …
Electrochemical Detection Of L-Cysteine Based On Iron Phthalocyanine/Nitrogen-Doped Graphene Modified Electrodes, Jing-Jing Xiao, Hui-Ying Xu, Li Xu, Bao-Hong Liu
Electrochemical Detection Of L-Cysteine Based On Iron Phthalocyanine/Nitrogen-Doped Graphene Modified Electrodes, Jing-Jing Xiao, Hui-Ying Xu, Li Xu, Bao-Hong Liu
Journal of Electrochemistry
In this study, we report a facile method to develop FePc/N-G hybrid modified electrode for the detection of L-cysteine. The electrochemical sensor was characterized by cyclic voltammetry and amperometric response. The sensor exhibited a wider linear range with rapid response which has outperformed pure FePc/GCE, highlighting the important role of nitrogen doped graphene as substrate for improving the electrochemical response property.
One-Step Synthesis Of Pani/Nihcf Hybrid Film Using Unipolar Pulse Electrodeposition And Its Electrocatalytic Reduction Performance For H2O2 Detection, Sen-Liang Liao, Xiu-Min Li, Xiao-Gang Hao, Yan-Hong Wang, Chun-Feng Xue, Yong-Hong Wang
One-Step Synthesis Of Pani/Nihcf Hybrid Film Using Unipolar Pulse Electrodeposition And Its Electrocatalytic Reduction Performance For H2O2 Detection, Sen-Liang Liao, Xiu-Min Li, Xiao-Gang Hao, Yan-Hong Wang, Chun-Feng Xue, Yong-Hong Wang
Journal of Electrochemistry
Organic–inorganic hybrid films composed of polyaniline/nickel hexacyanoferrate (PANI/NiHCF) were fabricated on platinum substrates using unipolar pulse one-step electrodeposition. The deposition mechanism of hybrid film was proposed: Due to high potential of unipolar pulse electrodeposition, which avoided the reduction of Fe(CN)63-, the films with high electrocatalytic property and “insoluble” form of NiHCF were achieved. The morphology and composition of PANI/NiHCF hybrid film were characterized by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and Fourier transform infrared spectroscopy (FT-IR). The effect of pulse potential on the electrochemical performance of hybrid film was investigated in detail. Results showed that …
Electrochemiluminescence Imaging Focusing: Array Analysis And Visualization Of Latent Fingerprints, Zhen-Yu Zhou, Lin-Ru Xu, Bin Su
Electrochemiluminescence Imaging Focusing: Array Analysis And Visualization Of Latent Fingerprints, Zhen-Yu Zhou, Lin-Ru Xu, Bin Su
Journal of Electrochemistry
Electrochemiluminescence (ECL) imaging, as a novel and powerful analytical method, possesses many distinct advantages, including simplicity, high controllability, high-throughput and visualization. In recent years, it has been used in developing portable and miniaturized ECL sensor, and made remarkable achievements. In this review, the progress of ECL imaging, focusing on array analysis and visualization of latent fingerprints, has been introduced briefly based on our recent investigations and an attempt has been made to propose the future research trend.
Direct Electrochemistry And Glucose Biosensing Of Glucose Oxidase-Gold Nanoparticles Composite Synthesized By Enzyme Method, Fang He, Xiao-Li Qin, Ying-Chun Fu, Chao Chen, Qing-Ji Xie, Shou-Zhuo Yao
Direct Electrochemistry And Glucose Biosensing Of Glucose Oxidase-Gold Nanoparticles Composite Synthesized By Enzyme Method, Fang He, Xiao-Li Qin, Ying-Chun Fu, Chao Chen, Qing-Ji Xie, Shou-Zhuo Yao
Journal of Electrochemistry
Glucose oxidase (GOx)-gold nanoparticles (AuNPs) composite was synthesized by the one-pot enzyme reaction in the mixture solution of NaAuCl4, GOx and glucose, and a Nafion/GOx-AuNPs/glassy carbon electrode was fabricated by the cast-coating method to examine the direct electrochemistry of GOx and the biosensing performance on this electrode. Such a GOx-AuNPs composite showed good direct-electrochemistry activity and bioactivity of GOx, probably because the enzyme-mediated AuNPs are close to the redox active centers of GOx. This enzyme electrode exhibited a linear amperometric response to glucose concentration (0.54 mmol·L-1) at -0.4 V (vs. SCE), and a detection limit of …
Preparation Of Surface Molecularly Imprinted Magnetic Nanoparticles For Hemoglobin Sensing, Chun-Fang Huang, Gui-Hong Yao, Jian-Ding Qiu
Preparation Of Surface Molecularly Imprinted Magnetic Nanoparticles For Hemoglobin Sensing, Chun-Fang Huang, Gui-Hong Yao, Jian-Ding Qiu
Journal of Electrochemistry
Surface molecularly imprinted magnetic nanoparticles (NPs) were prepared by employing dopamine (DA) as a functional monomer, hemoglobin (Hb) as a template, H2PtCl6 as an oxidant triggered DA polymerization on the surface of the Fe3O4 NPs. The Hb and the formed platinum nanoparticles (PtNPs) were embedded into the polydopamine (PDA). After removal of the Hb, the surface molecularly imprinted magnetic nanoparticles (imprinted Fe3O4/PDA-PtNPs) were formed, and then simply immobilized on the magnetic glassy carbon electrode (imprinted Fe3O4/PDA-PtNPs/MGCE) for Hb sensing. The imprinted Fe3O4/PDA-PtNPs …
Enzyme-Based Dna Electrochemical Biosensors: Recent Trends, Chun-Shui Lin, Yi-Ru Wang, Xi Chen
Enzyme-Based Dna Electrochemical Biosensors: Recent Trends, Chun-Shui Lin, Yi-Ru Wang, Xi Chen
Journal of Electrochemistry
DNA electrochemical sensors have greatly promoted the development of biosensors for their high sensitivity, good selectivity, short analysis time and low cost. To further improve the detection sensitivity and selectivity, protein enzymes, functional nucleic acid enzymes etc. are often used due to the advantages of high catalytic efficiency and specificity. This review demonstrates the research progress of electrochemical sensors based on enzymatic amplification and analyses some existing problems of electrochemical sensors.
Resolve Mono-Electronic Process In The Voltammetric Behaviors Of Multi-Redox Bis-Coenzyme Q0, Hao Zhou, Yi-Tao Long
Resolve Mono-Electronic Process In The Voltammetric Behaviors Of Multi-Redox Bis-Coenzyme Q0, Hao Zhou, Yi-Tao Long
Journal of Electrochemistry
A widely held concept in electrochemistry is that truly elementary electron-transfer reactions always involve the exchange of one electron, therefore, an overall process involving a change of n electrons must involve n distinct electron-transfer steps. It is highly desirable to resolve multiple-step electron transfer reactions into each electron transfer step. The electrochemical behaviors of coenzyme Q0 and methylene-bridged Bis-coenzyme Q0 were investigated by cyclic voltammetry and square wave voltammetry in nonaqueous dichloromethane containing 0.15 mol·L-1 Bu4NClO4 as the supporting electrolyte. The redox reaction of coenzyme Q0 is well described as two chemically reversible …
Electrochemical And Spectroscopic Studies Of Ethanol Oxidation On Nano-Cubic Pt Modified By Tin Adatoms, Lu Rao, Bin-Wei Zhang, Yan-Yan Li, Yan-Xia Jiang, Shi-Gang Sun
Electrochemical And Spectroscopic Studies Of Ethanol Oxidation On Nano-Cubic Pt Modified By Tin Adatoms, Lu Rao, Bin-Wei Zhang, Yan-Yan Li, Yan-Xia Jiang, Shi-Gang Sun
Journal of Electrochemistry
The nano-cubic Pt modified by tin (Sn) was synthesized and used to investigate the role of this adatom played in the ethanol oxidation. The onset potential of ethanol oxidation was significantly shifted negatively which can be forward about 300 mV when the coverage of Sn (θSn)was 0.9. The electrtochemical in situ FTIR result demonstrated that the amount of CO2 increased first, and then decreased with θSn increased, and reached the maximun when θSn was 0.38. Furthermore, the formation of acetic acid could be observed at very low potential (-0.05 V) after modifying Sn adatom, and the amount of acetic …
Electrochemical And Surface Enhanced Raman Spectroscopic Studies Of Benzimidazole On Nickel Electrode, Ping-Jie Wei, Ya-Xian Yuan, Min-Min Xu, Jian-Lin Yao, Ren-Ao Gu
Electrochemical And Surface Enhanced Raman Spectroscopic Studies Of Benzimidazole On Nickel Electrode, Ping-Jie Wei, Ya-Xian Yuan, Min-Min Xu, Jian-Lin Yao, Ren-Ao Gu
Journal of Electrochemistry
By measuring cyclic voltammograms and polarization curves, the inhibition effects of benzimidazole (BMIH) concentration in acetonitrile system on a nickel electrode were investigated. It was found that the oxidation and the corrosion potentials shifted positively, and the oxidation current decreased with the increase in the concentration of BIMH. Potential dependent adsorption and film formation behavior of BMIH on the nickel electrode were investigated by in situ SERS spectroscopy. With the potential moving from negative direction to positive direction, the complexes made of BIMH and nickel were formed, preventing the nickel electrode from corrosion. In addition, the 0.001 mol·L-1 of …
In-Situ Afm Force Curve Investigations On Layered Structures Of Au(111)-Ionic Liquid Interfaces And Temperature Dependence, Xiao Zhang, Yun-Xin Zhong, Jia-Wei Yan, Bing-Wei Mao
In-Situ Afm Force Curve Investigations On Layered Structures Of Au(111)-Ionic Liquid Interfaces And Temperature Dependence, Xiao Zhang, Yun-Xin Zhong, Jia-Wei Yan, Bing-Wei Mao
Journal of Electrochemistry
By utilizing in-situ AFM force curve measurements systematic investigations have been carried out on Au(111)-ionic liquid interface in BMIPF6 and OMIPF6 of imidazolium-based ionic liquids with different lengths of alkyl side chains. The temperature dependence of the number, thickness and stability of the layered structures of each system are studied by performing AFM force curve measurements at potentials far negative of the PZC. The layered structures at Au (111)/BMIPF6 interface are composed of two charged interior layers and two neutral exterior layers at -1.0 V, while those at Au (111)/OMIPF6 interface only one charged interior layer …
Investigation Of The Dynamics Of Photocarriers During Photoelectrochemical Water Splitting By Combination Of Photoelectrochemistry And Transient Absorption Spectroscopy, Wen-Hua Leng
Journal of Electrochemistry
Semiconductor photoelectrochemical hydrogen production is an important and promising technology for utilizing solar energy. The efficiency of hydrogen production depends on the efficiencies of separation and transport of photo-generated carriers. A deep understanding of the behavior of these processes has guiding significance for designing efficient solar hydrogen device. photoelectrochemical and transient absorption spectroscopy methods are powerful tool for studying the microscopic dynamics and mechanism of photocatalytic reaction. This review describes the part of the latest results of the author regarding the semiconductor photoelectrochemical hydrogen production obtained by these methods,and the problems and future research priorities in this field are proposed.
High Sensitive Detection Of Cd(Ii) And Pb(Ii) Based On Antimony-Film Covered Pencil Core Electrodes, Shan Chen, Zhao-Yan Zheng, Yi-Min Fang, Li-Qing Zheng, Jian-Jun Sun
High Sensitive Detection Of Cd(Ii) And Pb(Ii) Based On Antimony-Film Covered Pencil Core Electrodes, Shan Chen, Zhao-Yan Zheng, Yi-Min Fang, Li-Qing Zheng, Jian-Jun Sun
Journal of Electrochemistry
In this paper, a pencil core was used as the substrate for an antimony-film electrode for simultaneous detection of Cd(II) and Pb(II) by square-wave anodic stripping voltammetry (SWASV). With the deposition time of 180 s, the low limit of detection (LOD) for the electrode was determined to be 0.075·g?L-1 for Cd(II), while 0.13·g·L-1 for Pb(II) with good reproducibility in low pH solutions (pH = 2). The results show a much lower LOD than that of bismuth-film pencil core electrode. Finally, this antimony-film electrode was successfully applied to determine Cd(II) and Pb(II) in tap water.
A Sensitive And Label-Free Electrochemical Aptasensor Based On Signal Amplification Of Carbon Nanotubes, Chun-Yan Deng, Hui-Min Fan, Juan Xiang, Yuan-Jian Li
A Sensitive And Label-Free Electrochemical Aptasensor Based On Signal Amplification Of Carbon Nanotubes, Chun-Yan Deng, Hui-Min Fan, Juan Xiang, Yuan-Jian Li
Journal of Electrochemistry
A label-free electrochemical sensing electrode for highly sensitive detection of adenosine was constructed based on the signal amplification of carbon nanotubes (CNTs). The change in the interfacial feature of the modified electrode was characterized by electrochemical impedance spectroscopy. Using [Ru(NH3)6]3+ as the signaling moiety, adenosine with concentrations as low as 0.027 nmol·L-1 can be selectively detected. Additionally, the fabrication of this present aptasensor was simple, time-saving and cost-effective. Compared with other reported aptasensors, the proposed aptasensor had advantages of excellent sensitivity, selectivity and simplicity, which plays a potential role in development of aptasensor.
Surface Enhanced Raman Spectroscopic Studies Of Pyridine Adsorbed On Ti/Au@Sio2 Film Electrode, Min-Min Xu, Ke Liu, Qing-Hua Guo, Jian-Lin Yao
Surface Enhanced Raman Spectroscopic Studies Of Pyridine Adsorbed On Ti/Au@Sio2 Film Electrode, Min-Min Xu, Ke Liu, Qing-Hua Guo, Jian-Lin Yao
Journal of Electrochemistry
This study was performed based on shell-isolated nanoparticles-enhanced Raman spectroscopy (SHINERS) technology. The Au@SiO2 nanoparticles were prepared and characterized by TEM and cyclic voltammetry. It was shown that the shell of SiO2 was compact. The high quality signal measured by surface enhanced Raman spectroscopy (SERS) was obtained from the adsorbed pyridine on Ti/Au@SiO2 electrode. The origin of the SERS signals was further confirmed by testing Pt and Ni electrodes. In addition, potential dependent adsorption behavior was investigated. It was found that pyridine was adsorbed parallel on the surface from -0.1 V to -0.6 V, and converted to …
Horseradish Peroxidase-Attapulgite Clay Nanocomposites: Fabrication And Application To Sensing The Extracellular H2O2 Released From Cells, Ping Wu, Chen-Xin Cai
Horseradish Peroxidase-Attapulgite Clay Nanocomposites: Fabrication And Application To Sensing The Extracellular H2O2 Released From Cells, Ping Wu, Chen-Xin Cai
Journal of Electrochemistry
The nanostructured attapulgite clay was employed as a support matrix for immobilizing horseradish peroxidase (HRP). FTIR and electrochemical methods demonstrated that HRP had been effectively assembled on attapulgite surface with the formation of HRP-attapulgite nanocomposites. The HRP-attapulgite hybrid was deposited on the glassy carbon (GC) electrode forming the HRP-attapulgite/GC electrode. Cyclic voltammetric results showed a pair of well-defined redox peaks, which were ascribed to direct electron transfer (DET) of HRP, with the formal potential E0′ = -335 mV (vs. SCE) in the phosphate buffer solution (PBS, pH 7.0). The dependence of E0′ on solution pH indicated …