Open Access. Powered by Scholars. Published by Universities.®
Pharmaceutics and Drug Design Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- New Jersey Institute of Technology (33)
- University of Kentucky (6)
- Old Dominion University (3)
- Virginia Commonwealth University (3)
- The British University in Egypt (2)
-
- University of Texas at Tyler (2)
- Augustana College (1)
- Chapman University (1)
- City University of New York (CUNY) (1)
- Duquesne University (1)
- Fordham University (1)
- Louisiana Tech University (1)
- Portland State University (1)
- Purdue University (1)
- University of Louisville (1)
- University of Nebraska Medical Center (1)
- University of New Mexico (1)
- West Virginia University (1)
- Keyword
-
- Dissolution testing (6)
- Drug delivery (4)
- Microfluidics (4)
- Minimum agitation speed (3)
- Nanoparticles (3)
-
- Retreat-blade impeller (3)
- Baffling conditions (2)
- Biomedicine (2)
- Dissolution profiles (2)
- Drug encapsulation (2)
- Iontophoresis (2)
- Nanomaterials (2)
- Off-center paddle impeller (2)
- Pharmaceutical hot melt extrusion (HME) (2)
- Solids suspension (2)
- 4D DLP Bioprinting (1)
- 4D EPR Imaging (1)
- 4D Extrusion Bioprinting (1)
- AIDS (1)
- Absurdity (1)
- Active pharmaceutical ingredient (API ) (1)
- Agitation speed (1)
- Agitation systems (1)
- Air gap membrane distillation (AGMD) (1)
- Angle-mounted impellers (1)
- Angled-mounted impellers (1)
- Antibacterial agent (1)
- Antibiotic (1)
- Antimicrobials (1)
- Antioxidant Therapeutics (1)
- Publication Year
- Publication
-
- Theses (33)
- Theses and Dissertations (3)
- Theses and Dissertations--Chemical and Materials Engineering (3)
- Electronic Theses and Dissertations (2)
- Nanotechnology Research Centre (2)
-
- Technology Faculty Publications and Presentations (2)
- Theses and Dissertations--Pharmacy (2)
- Biology: Student Scholarship & Creative Works (1)
- Complex Systems Faculty Publications and Presentations (1)
- Department of Medicine Faculty Publications (1)
- Dissertations, Theses, and Capstone Projects (1)
- Doctoral Dissertations (1)
- Electrical & Computer Engineering Faculty Publications (1)
- Graduate Theses, Dissertations, and Problem Reports (ETD) (1)
- Mechanical & Aerospace Engineering Faculty Publications (1)
- Nanoscience and Microsystems ETDs (1)
- Pharmacy Faculty Articles and Research (1)
- Student Theses 2015-Present (1)
- The Summer Undergraduate Research Fellowship (SURF) Symposium (1)
- Theses & Dissertations (1)
- Theses and Dissertations--Neuroscience (1)
- Publication Type
Articles 31 - 60 of 61
Full-Text Articles in Pharmaceutics and Drug Design
Experimental Determination Of The Agitation Requirements For Solids Suspension In Dissolution Systems Using A Mini Paddle Apparatus, Yang Song
Theses
Dissolution testing is a critical step in quality control of manufactured final products in the pharmaceutical industry. The United State Pharmacopeia (USP) Dissolution Testing Apparatus 2 (paddle) is the most widely used dissolution test devices in the pharmaceutical industry to formulate solid drug dosage forms and to develop quality control specifications for its manufacturing process.
Mini vessels and mini paddle dissolution testing systems are smaller versions of the USP 2 Apparatus. The concept of the mini paddle apparatus is similar to that of the USP 2 setup but it is scaled down about to 1/5 of the volume and 40% …
Effect Of Impeller Submergence On Power Dissipation And Solids Suspension In Mixing Systems Equipped With Pitch-Blade Turbines, Yufeng Song
Theses
Mixing and dispersion of solids in a liquid is a process frequently encountered in the pharmaceutical industry and often conducted in cylindrical baffled tanks stirred by mechanical impellers. In operations where the liquid level is decreased (as often which emptying the tank) the process must be stopped when the solids are no longer suspended. In this work, the minimum agitation to suspend solids (Njs) when the liquid level was lowered, and the impeller submergence Sb changed as a result were determined for the case of a six-blade, pitch-blade turbine (6-PBT) impeller. The power consumed by the impeller …
Experimental Determination Of Solids Suspension With Angled Impeller In A Pharmaceutical Mixing Vessel, Yingxi Tang
Experimental Determination Of Solids Suspension With Angled Impeller In A Pharmaceutical Mixing Vessel, Yingxi Tang
Theses
Angled-mounted impellers are commonly used in a number of pharmaceutical industry applications, from laboratory reactors to full-scale tanks. In these systems, the impeller is not centrally and vertically mounted, as in most stirred vessels, but it enters the vessel, and is therefore immersed in the fluid, at an angle from the vertical. This arrangement provides some baffling effects that would not otherwise exist if the impeller was centrally mounted.
One common requirement for such systems is that they are capable of suspending small solids dispersed in the liquid. Therefore, it is critical to know the value of the minimum agitation …
Effects Of Three Dry Powder Inhalers On Deposition Of Aerosolized Medicine In The Human Oral-Pharyngeal-Laryngeal Regions, Mohammed Ali
Effects Of Three Dry Powder Inhalers On Deposition Of Aerosolized Medicine In The Human Oral-Pharyngeal-Laryngeal Regions, Mohammed Ali
Technology Faculty Publications and Presentations
The dry powder inhaler (DPI) is a popular, effective and convenient drug delivery device for inhalation therapy to treat asthma. However, a large quantity (approximately 54%) of inhaled aerosols deposit in the oropharyngeal region. Deposition in this region is undesirable because it provides minimum therapeutic benefits and has adverse localized or systemic side effects. This study reports a method of examining electrostatic charge effects on deposition of three DPI aerosols (Spiriva™ Handihaler, Advair Diskus™, and Pulmicort™ Turbohaler) in a cadaver-based cast of the human oral-pharyngeal-laryngeal (OPL) regions. Experimental aerosols were generated from the three commercially available …
Target-Directed Biosynthetic Evolution: Redirecting Plant Evolution To Genomically Optimize A Plant’S Pharmacological Profile, Dustin Paul Brown
Target-Directed Biosynthetic Evolution: Redirecting Plant Evolution To Genomically Optimize A Plant’S Pharmacological Profile, Dustin Paul Brown
Theses and Dissertations--Neuroscience
The dissertation describes a novel method for plant drug discovery based on mutation and selection of plant cells. Despite the industry focus on chemical synthesis, plants remain a source of potent and complex bioactive metabolites. Many of these have evolved as defensive compounds targeted on key proteins in the CNS of herbivorous insects, for example the insect dopamine transporter (DAT). Because of homology with the human DAT protein some of these metabolites have high abuse potential, but others may be valuable in treating drug dependence. This dissertation redirects the evolution of a native Lobelia species toward metabolites with greater activity …
Effect Of Twin Screw Granulator Process Parameters On Granule Attributes, Haosheng Xu, Ridade Sayin, James Litster
Effect Of Twin Screw Granulator Process Parameters On Granule Attributes, Haosheng Xu, Ridade Sayin, James Litster
The Summer Undergraduate Research Fellowship (SURF) Symposium
Twin screw wet granulation has been considered as an efficient and effective technique of manufacturing granules (agglomerates made up of small particles) and has been widely applied in pharmaceutical industry. However, narrow granule size distributions are difficult to achieve. This study aims to elucidate the effect of process parameters such as liquid feed rate and screw configuration on the granule attributes through granule characterization. The methods used are sieve analysis (for size distribution), liquid distribution (determining the dye concentration in the granules) and density and porosity (percentage gas volume in the granule) analyses. A sieve shaker is used to divide …
Assessment Of A Marine Polysaccharide For Use As Excipient In Pharmaceutical Hot-Melt Extrusion, Qing Ye
Assessment Of A Marine Polysaccharide For Use As Excipient In Pharmaceutical Hot-Melt Extrusion, Qing Ye
Theses
Pharmaceutical Hot Melt Extrusion (HME) is currently investigated by both industry and academia as a method for manufacturing solid oral dosages with improved bioavailability of poorly-water soluble active pharmaceutical ingredients (APIs) and control drug release of water-soluble APIs. Although HME is traditionally utilizing synthetic polymers to produce such dosages, biopolymers constantly gain ground by virtue of renewability, biocompatibility and in some cases biodegradability. In this work, the possibility of using Keltone, a marine polysaccharide derived from brown seaweed, as a polymeric excipient for pharmaceutical HME is explored. Keltone is insoluble in acidic pH and soluble in basic pH, therefore making …
Hydrodynamic Cfd Modeling Of A Pharmaceutical Reactor Vessel Provided With A Retreat-Blade Impeller Under Different Baffling Conditions, Christopher G. Foehner
Hydrodynamic Cfd Modeling Of A Pharmaceutical Reactor Vessel Provided With A Retreat-Blade Impeller Under Different Baffling Conditions, Christopher G. Foehner
Theses
In the pharmaceutical industry, glass-lined reactors and vessels are often utilized to carry out a variety of different unit operations. Within these systems, both the vessel and impellers are typically glass-lined in order to provide superior corrosion resistance, prevent product contamination, and enhance cleanability. This approach, in turn, often requires the use of different, and sometimes sub-optimal, baffling conditions, which affect the hydrodynamics of the vessels and the reactor performance.
Computational Fluid Dynamics (CFD) is a computational tool that employs numerical methods and algorithms to discretize and numerically solve partial differential equations (PDEs) representing mass, energy, and momentum conservation equations …
Dispersion And Dissolution Kinetics Of Api Particles In Pharmaceutical Hot Melt Extrusion, Wang Zhan
Dispersion And Dissolution Kinetics Of Api Particles In Pharmaceutical Hot Melt Extrusion, Wang Zhan
Theses
Pharmaceutical Hot Melt Extrusion (HME) is essentially a special case of polymer compounding. The elementary steps involved in traditional plastics melt processing are handling of particulates, melting, dispersive and distributive mixing, devolatilization and stripping, and finally pressurization and pumping. However, for pharmaceutical HME, the dissolution of the API (Active Pharmaceutical Ingredient) is an additional and very important elementary step, along with the melting of the polymeric excipient that precedes it, and mixing which accelerates the dissolution process. A major concern in pharmaceutical HME is the thermal degradation of the API. To avoid overexposure of API to heat while ensuring complete …
Experimental Determination Of The Mixing Requirements For Solid Suspension In Pharmaceutical Stirred Tank Reactors, Anqi Zhou
Theses
Glass and glass-lined, stirred-tank reactors are of significant importance in the pharmaceutical and related industries. Because of fabrication issues, a retreat blade impeller (RBI) with a low impeller clearance off the tank bottom is commonly used in glass-lined reactors, typically combined with a single baffle (providing only partial baffling conditions) mounted from the top of the reactor. In addition, these reactors are often provided with a torispherical bottom. Other configurations are also used, including full baffling or no baffles at all, hemispherical bottoms, and different impeller types. Despite their common use, some of the most important mixing characteristics of this …
Quantification Of Factors Governing Drug Release Kinetics From Nanoparticles: A Combined Experimental And Mechanistic Modeling Approach, Kyle Daniel Fugit
Quantification Of Factors Governing Drug Release Kinetics From Nanoparticles: A Combined Experimental And Mechanistic Modeling Approach, Kyle Daniel Fugit
Theses and Dissertations--Pharmacy
Advancements in nanoparticle drug delivery of anticancer agents require mathematical models capable of predicting in vivo formulation performance from in vitro characterization studies. Such models must identify and incorporate the physicochemical properties of the therapeutic agent and nanoparticle driving in vivo drug release. This work identifies these factors for two nanoparticle formulations of anticancer agents using an approach which develops mechanistic mathematical models in conjunction with experimental studies.
A non-sink ultrafiltration method was developed to monitor liposomal release kinetics of the anticancer agent topotecan. Mathematical modeling allowed simultaneous determination of drug permeability and interfacial binding to the bilayer from release …
Dissolution Of Different Commercial Aspirin Tablets Using A Novel Off-Center Paddle Impeller (Opi) Dissolution Testing System, Yang Qu
Theses
Dissolution testing is routinely conducted in the pharmaceutical industry to provide in vitro drug release information for quality control purposes. The most common dissolution testing system for solid dosage forms is the United States Pharmacopeia (USP) Dissolution Testing Apparatus 2. In this work, a modified Apparatus 2, termed "OPI" System for "off-center paddle impeller," in which the impeller is placed 8 mm off center in the vessel is tested to determine its sensitivity to differentiate between the dissolution profiles of differently formulated and manufactured tablets. Dissolution tests are conducted with both the OPI System and the Standard System using three …
Qsar Modeling Of Chemical Penetration Enhancers Using Novel Replacement Algorithms, Hui Qiu
Qsar Modeling Of Chemical Penetration Enhancers Using Novel Replacement Algorithms, Hui Qiu
Theses
The applications of transdermal delivery are limited because of the resistance of the skin to drug diffusion. Only potent drugs, with molecular weight less than 500 Da, are suitable to cross the skin barrier. Chemical Penetration Enhancers (CPEs) are used to promote the absorption of solutes across the dermal layers. In this investigation, a Quantitative Structure-Activity Relationship (QSAR) model is applied to relate chemical penetration enhancer structures with the flux enhancement ratio through a statistical approach.
A database, consisting of 61 non-polar CPEs, is selected for the study. Each compound is represented by 777 QSAR descriptors, which encode the physical …
Hollow Fiber Membrane-Based Air Gap Membrane Distillation, Xuan Wang
Hollow Fiber Membrane-Based Air Gap Membrane Distillation, Xuan Wang
Theses
Membrane Distillation (MD) is a thermally-driven separation process. In this research, desalination of 1 % NaCl solution is achieved by one type of MD namely, Air Gap Membrane Distillation (AGMD). The characteristics of AGMD are evaluated by using a hollow-fiber-set-based compact device. Hot brine solution and cold water are passed through two different fiber sets separately: porous hydrophobic polyvinylidene fluoride hollow fibers of the E type (PVDF E) and solid polypropylene (PP) hollow fibers. Vapor from the hot brine crosses the membrane pores of the PVDF fibers and the air gap, and finally condenses over the surface of solid hollow …
Hydrodynamic Effects Of A Cannula In A Usp Dissolution Testing Apparatus 2, Qianqian Liu
Hydrodynamic Effects Of A Cannula In A Usp Dissolution Testing Apparatus 2, Qianqian Liu
Theses
Dissolution testing is routinely used in the pharmaceutical industry to provide in vitro drug release information for drug development and quality control purposes. The USP Testing Apparatus 2 is the most common dissolution testing system for solid dosage forms. Usually, sampling cannulas are used to take samples manually from the dissolution medium. However, the inserted cannula can alter the normal fluid flow within the vessel and produce different dissolution testing results.
The hydrodynamic effects introduced by a permanently inserted cannula in a USP Dissolution Testing Apparatus 2 were evaluated by two approaches. Firstly, the dissolution tests were conducted with two …
Effect Of Tablet Compression On The Dissolution Of Aspirin Tablets Using A Novel Off-Center Paddle Impeller (Opi) Dissolution Testing System, Chuan Sun
Theses
In the pharmaceutical industry, dissolution testing is routinely carried out to determine the dissolution rate of oral solid dosage forms. Among several testing devices, the USP Dissolution Apparatus 2 is the device most commonly used. However, despite its widespread use, this apparatus has been shown to produce test failures and to be very sensitive to a number of small geometry changes.
The objective of this study was to determine whether a novel dissolution system termed “OPI” for “off-center paddle impeller” was sensitive enough to determine differences in tablet dissolution profiles caused by different compression pressure during the tablet manufacturing process. …
Engineering Spores To Display G Protein-Coupled Receptors For Directed Evolution, Alyssa Misoo Kim
Engineering Spores To Display G Protein-Coupled Receptors For Directed Evolution, Alyssa Misoo Kim
Theses
All human cells are surrounded by a plasma membrane made from a phospholipid bilayer, which is responsible for maintaining a biologically active species, while stopping entry of deleterious substances from the outside. G protein-coupled receptors (GPCRs) are the membrane proteins, which transmit signals across the cell membrane. GPCRs are involved in almost every physiological process, and irregular control leads to pathological conditions. Therefore, they are major drug targets. Crystal structure determination is required to understand the molecular details of activation/deactivation. However, GPCRs are difficult to crystallize because of stability issues. An efficient protein engineering system needs to be developed. The …
Low Soluble Drug Encapsulation Based On Architecture Of Layer-By-Layer Assembly For Longer Circulation Time And Targeted Therapy, Pravin Pattekari
Low Soluble Drug Encapsulation Based On Architecture Of Layer-By-Layer Assembly For Longer Circulation Time And Targeted Therapy, Pravin Pattekari
Doctoral Dissertations
A combined effect of sonication and layer-by-layer assembly (LbL) enhances the solubility of many poorly soluble inorganic and organic materials by forming stable particles with ca. 200 nm size and up to 90 wt% of loading. The entire method is reproducible, easy-to-handle, and flexible for varying surface properties according to the application of the materials. The method develops good colloidal stability of materials in buffers and maintains architecture for future improvement. A top-down approach, with a combined effect of sonication and LbL assembly, ruptures the material and allows adsorption of oppositely charged polyelectrolytes simultaneously. Thus, the approach is applicable for …
Hydrodynamic Effects Of An Arch-Shaped Fiber Optic Probe In A Dissolution Testing Apparatus 2, Yiran Zhang
Hydrodynamic Effects Of An Arch-Shaped Fiber Optic Probe In A Dissolution Testing Apparatus 2, Yiran Zhang
Theses
Dissolution testing is widely used in the pharmaceutical industry to evaluate newly developed drug formulations and as a quality control method to insure that solid dosage forms have consistent dissolution property. Typically, samples are manually drawn from the dissolution vessel prior to analysis. An approach to overcome the limitations of manual sampling consists in the use of sampling probes, such as fiber optic probes, permanently inserted in the dissolution medium and continually sampling the drug concentration in it as the solid dosage form dissolves. Despite their advantages, permanently inserted fiber optic probes can alter the normal fluid flow within the …
Preparation Of Different Polyamide Nanofiltration Membranes By Interfacial Polymerization And The Effect Of Post-Polymerization Treatment On Separation Performance, Yu Qin
Theses
Interfacial polymerization (IP) is a powerful technique for fabrication of thin film composite (TFC) membranes. In this study, polyamide nanofiltration (NF) composite membranes ware prepared by interfacial polymerization of polyethylenimine (PEI) or m-phenylene diamine (MPD) with isophthaloyl dichloride (IPD) on the surface of a porous polyethersulfone (PES) support. Concentrations of monomer reactants for this reaction were decided by equivalent weight ratio. A standard IP procedure was applied to successfully coat PES flat films. After preparation, three different post-polymerization treatments were employed and one optimal treatment was proven after membrane testing.
The TFC flat film membranes were characterized by nanofiltration of …
A System Dynamics Model Of Pharmaceutical Opioids: Medical Use, Diversion, And Nonmedical Use, Teresa Schmidt, Wayne Wakeland, J. David Haddox
A System Dynamics Model Of Pharmaceutical Opioids: Medical Use, Diversion, And Nonmedical Use, Teresa Schmidt, Wayne Wakeland, J. David Haddox
Complex Systems Faculty Publications and Presentations
A dramatic rise in the nonmedical of pharmaceutical opioids has presented the United States with a substantial public health problem. Nonmedical use of prescription pain relievers has become increasingly prevalent in the US over the last two decades, and diversion of medicines obtained by prescription is assumed to be a major source of supply for nonmedical opioid use. Policymakers striving to protect population health by ameliorating the adverse outcomes of nonmedical use of opioid analgesics could benefit from a systems-level model which reflects the complexity of the system and incorporates the full range of available data. To address this need, …
Dissolution Testing Of Prednisone And Salicylic Acid Calibrator Tablets At Different Tablet Locations, Anandhavalavan Arulmozhi
Dissolution Testing Of Prednisone And Salicylic Acid Calibrator Tablets At Different Tablet Locations, Anandhavalavan Arulmozhi
Theses
Dissolution testing is routinely carried out in the pharmaceutical industry to determine the rate of dissolution of solid dosage forms. This test is one of the several tests that pharmaceutical companies typically conduct on oral dosage formulations (e.g., tablets) to determine compliance. The USP Dissolution Testing Apparatus 2 is the most common of the apparatuses listed in the USP. However, it has been shown previously that the dissolution profile of a tablet undergoing dissolution in the USP Dissolution Apparatus 2 can be affected by the tablet location in the apparatus.
In this work, the dissolution rates of both non-disintegrating tablets …
Dissolution Of Disintegrating Solid Dosage Forms In A Modified Dissolution Testing Apparatus 2, Shrutiben Rameshbhai Parekh
Dissolution Of Disintegrating Solid Dosage Forms In A Modified Dissolution Testing Apparatus 2, Shrutiben Rameshbhai Parekh
Theses
Dissolution tests are routinely carried out in the pharmaceutical industry to determine the dissolution rate of solid dosage forms. Dissolution testing serves as a surrogate for drug bioavailability through in vitro–in vivo correlation (IVIVR), and it additionally helps in guiding the development of new formulations and in assessing lot-to-lot consistency, thus ensuring product quality. The United States Pharmacopoeia (USP) Dissolution Testing Apparatus 2 is the device most commonly used for this purpose. Despite its widespread use, dissolution testing using this apparatus remains susceptible to significant error and test failures. There is documented evidence that this apparatus is sensitive to several …
Transdermal And Transbuccal Delivery Of Lidocaine And Nicotine : Combined Effects Of Iontophoresis And Chemical Enhancers, Ran Wei
Theses
This study focused on the effects of iontophoresis and chemical enhancers on drug release. The transport of Lidocaine HCl (LHCl) and Nicotine Hydrogen Tartrate (NHT) through the skin and mucosa was evaluated for potential clinical applications. These two potential delivery routes have the advantage of avoiding first-pass effect. Samples were pretreated with enhancer solutions for one hour before the experiments. Passive or 0.3 mA iontophoresis-assisted drug diffusion was conducted for 8 hours to monitor the cumulative amount of drug released. Graphical methods and mathematical optimization techniques were implemented to analyze the data. The effects of chemical enhancers on the delivery …
Minimum Agitation Speed For Solid Suspension And Mixing Time In A Torispherical -Bottomed Pharmaceutical Stirred Tank Under Different Baffling Conditions, Dilanji Bhagya Wijayasekara
Minimum Agitation Speed For Solid Suspension And Mixing Time In A Torispherical -Bottomed Pharmaceutical Stirred Tank Under Different Baffling Conditions, Dilanji Bhagya Wijayasekara
Theses
The minimum agitation speed, NS, required to just suspend solid particles dispersed in water was experimentally determined in this work for a glass-lined type of mixing tank provided with a torispherical bottom and agitated with a retreat-blade impeller under different baffling configurations. Ns for the same tank but equipped with a different agitation system, namely an axial impeller, was also experimentally determined for the purpose of comparing of performances of the two systems. The effect of impeller off- bottom clearance and the vessel's liquid level on the minimum agitation speed were also experimentally studied. Njs, was experimentally determined …
Experimental Investigation Of Mixing Time In A Stirred, Torispherical-Bottomed Tank Equipped With A Retreat-Blade Impeller, Nonjaros Chomcharn
Experimental Investigation Of Mixing Time In A Stirred, Torispherical-Bottomed Tank Equipped With A Retreat-Blade Impeller, Nonjaros Chomcharn
Theses
Glass-lined reactors are typically used in the pharmaceutical and specialty chemicals industries because of their material compatibility with most reactants and their cleanability. These reactors are typically equipped with a retreat-blade impeller placed close to the bottom of the tank a single baffle mounted from the top. The mixing performance of such reactors has not received significant attention in the literature, despite their ubiquitous presence in the pharmaceutical industry. In particular, mixing time, i.e., the time required by the system to achieve a predefined level of homogeneity, has not been studied to any significant degree.
In this work, the mixing …
Mixing Performance Of A Novel, Continuous Confined Impinging Jets Mixer Using Competitive Reactions, Han Zheng
Mixing Performance Of A Novel, Continuous Confined Impinging Jets Mixer Using Competitive Reactions, Han Zheng
Theses
In this work, a novel continuous flow apparatus featuring the impingement of fluid jet streams in the presence of ultrasonic energy provided by an ultrasonic probe was tested using competitive reactions in order to determine its mixing effectiveness. The ultrasonic energy enhances micromixing of the fluid jet streams, which results in an overall mixing effectiveness improvements in different physical and chemical processes.
In the competitive reactions system used here (third Bourne reaction), one stream containing sodium hydroxide was continuously fed to the first impinging jet, while an aqueous solution of hydrochloric acid and ethyl chloroacetate was fed to the second …
Preparation Of Nanovehicles For Targeted Drug Delivery, Anagha Avinash Bhakay
Preparation Of Nanovehicles For Targeted Drug Delivery, Anagha Avinash Bhakay
Theses
Application of nanotechnology in pharmaceutical research has opened new frontiers for drug development and its efficient delivery. In recent years, the focus of the research has been on the engineering of nano/micro-particulate structures for efficient and targeted delivery of drugs for selective and enhanced absorption. This work throws light on the preparation of biodegradable and non-toxic nanoparticulate systems for targeted drug delivery. The drug vehicles were made by two different processes namely electrostatic interactions and desolvation process. The drug carriers made by these processes were found to be in the size range of 150-200nm which is necessary for cellular uptake …
Experimental Investigation Of The Fluid Velocity Distribution In Stirred Tank Reactors Equipped With Retreat-Blade Impellers Using Laser Doppler Velocimetry, Deepak Rajesh Madhrani
Experimental Investigation Of The Fluid Velocity Distribution In Stirred Tank Reactors Equipped With Retreat-Blade Impellers Using Laser Doppler Velocimetry, Deepak Rajesh Madhrani
Theses
Stirred tank reactors are commonly used in the pharmaceutical industry for synthesis of Active Pharmaceutical Ingredients (API's) and their intermediates. Typically, these vessels are glass-lined and are provided with a single retreat-blade glass-lined impeller and a single baffle. Despite their ubiquitous utilization in the pharmaceutical industry for at least the past 40 years, the mixing characteristics of these systems have not been studied to any great extent, making it difficult to predict mixing performance in any given operation.
In this work, the velocity distribution inside the typical glass-lined vessel/impeller system was experimentally quantified using Laser Doppler Velocimetry (LDV), which is …
Ultra-Fine Particle Formation Using Principle Of Rapid Expansion Of Supercritical Solutions`, Miraj Minesh Sheth
Ultra-Fine Particle Formation Using Principle Of Rapid Expansion Of Supercritical Solutions`, Miraj Minesh Sheth
Theses
There are indications in the chemical and pharmaceutical industries that the reduction in size of a crystalline particle can lead to better performance of the drug compound, particularly for water insoluble drugs, in the final dosage form. Many particle formation techniques have been investigated in recent years by researchers to obtain desired particulate sizes and size distributions. Supercritical fluid technologies have been successfully investigated for particle formation due to its unique gas/liquid properties in the supereritical state. In this report, results of particle formation using the principles of Rapid Expansion of Supercritical Solutions (RESS) have been documented.
In the RESS …