Articles 301 - 315 of 315

Full-Text Articles in Radiology

Identifying Treatment Planning System Errors In Iroc-Houston Head And Neck Phantom Irradiations, James Kerns Aug 2016

Identifying Treatment Planning System Errors In Iroc-Houston Head And Neck Phantom Irradiations, James Kerns

Dissertations and Theses (Open Access)

Treatment Planning System (TPS) errors can affect large numbers of cancer patients receiving radiation therapy. Using an independent recalculation system, the Imaging and Radiation Oncology Core-Houston (IROC-H) can identify institutions that have not sufficiently modelled their linear accelerators in their TPS model. Linear accelerator point measurement data from IROC-H’s site visits was aggregated and analyzed from over 30 linear accelerator models. Dosimetrically similar models were combined to create “classes”. The class data was used to construct customized beam models in an independent treatment dose verification system (TVS). Approximately 200 head and neck phantom plans from 2012 to 2015 were recalculated …


Voxel-Level Absorbed Dose Calculations With A Deterministic Grid-Based Boltzmann Solver For Nuclear Medicine And The Clinical Value Of Voxel-Level Calculations, Justin Mikell Dec 2015

Voxel-Level Absorbed Dose Calculations With A Deterministic Grid-Based Boltzmann Solver For Nuclear Medicine And The Clinical Value Of Voxel-Level Calculations, Justin Mikell

Dissertations and Theses (Open Access)

Voxel-level absorbed dose (VLAD) is rarely calculated for nuclear medicine (NM) procedures involving unsealed sources or 90Y microspheres (YM). The current standard of practice for absorbed dose calculations in NM utilizes MIRD S-values, which 1) assume a uniform distribution in organs, 2) do not use patient specific geometry, and 3) lack a tumor model. VLADs overcome these limitations. One reason VLADs are not routinely performed is the difficulty in obtaining accurate absorbed doses in a clinically acceptable time. The deterministic grid-based Boltzmann solver (GBBS) was recently applied to radiation oncology where it was reported as fast and accurate for both …


Characterization Of Low Density Intracranial Lesions Using Dual-Energy Computed To Mography, Jessica L. Nute May 2015

Characterization Of Low Density Intracranial Lesions Using Dual-Energy Computed To Mography, Jessica L. Nute

Dissertations and Theses (Open Access)

Calcific and hemorrhagic foci of susceptibility are frequently encountered on routine brain MR studies. Both etiologies cause variations in local magnetic field strength, leading to dark regions on the MR images that cannot be classified. Single-energy CT (SECT) can be used to identify lesions with attenuation over 100 HU as calcific, however lesions with lower attenuation cannot be reliably identified. While calcific lesions are unlikely to cause harm, hemorrhagic lesions carry a risk of subsequent intracranial bleeding; as such, identification of hemorrhage is vital in preventing the inappropriate use of anticoagulant medications in patients with hemorrhagic lesions.

Given there currently …


Use Of Positron Emission To Mography For Proton Therapy Verification, Jongmin Cho May 2014

Use Of Positron Emission To Mography For Proton Therapy Verification, Jongmin Cho

Dissertations and Theses (Open Access)

Positron emission tomography (PET), a tool commonly used for cancer staging and response monitoring, has recently been used for proton therapy verification. By imaging tissue activation following proton treatment, attempts have been made to verify proton dose and range. In this dissertation, two novel approaches were developed and tested for the purpose of help improve the proton dose and range estimation as well as verification.

Although there are still some challenges, attempts for proton dose verification using PET has been made by comparing Monte Carlo dose and PET simulations with treatment planned dose and measured PET. In this approach, …


Performance Evaluation Of Material Decomposition Using Rapid Kvp-Switching Dual-Energy Ct For Assessing Bone Mineral Density, John M. Wait May 2014

Performance Evaluation Of Material Decomposition Using Rapid Kvp-Switching Dual-Energy Ct For Assessing Bone Mineral Density, John M. Wait

Dissertations and Theses (Open Access)

Osteoporosis is diagnosed by assessing the bone mineral density (BMD) of the trabecular bone, and has previously been characterized with dual-energy x-ray absorptiometry (DXA) or single-energy computed tomography (SECT). Dual-energy computed tomography (DECT) is able to create two three-dimensional sets of images representing the densities of two materials in a given basis pair. DECT is theoretically capable of providing a true density measurement of trabecular bone material with the proper material basis pair.

Using the rapid kVp-switching GE HD750 scanner, the concentrations of various solutes were assessed in two-material syringe-phantoms in different experimental conditions with DECT material density images, SECT …


Scanned Ion Beam Therapy For Thoracic Tumors, John Gordon Eley Dec 2013

Scanned Ion Beam Therapy For Thoracic Tumors, John Gordon Eley

Dissertations and Theses (Open Access)

Although frequently cured of Hodgkin lymphoma, adolescents and young adults can develop radiation induced second cancers. These patients could potentially benefit from scanned ion radiotherapy yet likely would require motion mitigation strategies. In theory, four-dimensional (4D) optimization of ion beam fields for individual motion states of respiration can enable superior sparing of healthy tissue near moving targets, compared to other motion mitigation strategies. Furthermore, carbon-ion therapy can sometimes provide greater relative biological effectiveness (RBE) for cell sterilization in a target but nearly equivalent RBE in tissue upstream of the target, compared to proton therapy. Thus, we expected that for some …


Design, Synthesis And Development Of Transporter Targeting Agents For Image-Guided Therapy And Drug Delivery, Ning Tsao May 2013

Design, Synthesis And Development Of Transporter Targeting Agents For Image-Guided Therapy And Drug Delivery, Ning Tsao

Dissertations and Theses (Open Access)

The purpose of this study was to design, synthesize and develop novel transporter targeting agents for image-guided therapy and drug delivery. Two novel agents, N4-guanine (N4amG) and glycopeptide (GP) were synthesized for tumor cell proliferation assessment and cancer theranostic platform, respectively. N4amG and GP were synthesized and radiolabeled with 99mTc and 68Ga. The chemical and radiochemical purities as well as radiochemical stabilities of radiolabeled N4amG and GP were tested. In vitro stability assessment showed both 99mTc-N4amG and 99mTc-GP were stable up to 6 hours, whereas 68Ga-GP was stable up to 2 hours. Cell culture studies …


Novel Amino Acid Transporter-Targeted Radiotracers For Breast Cancer Imaging, Fanlin Kong Dec 2011

Novel Amino Acid Transporter-Targeted Radiotracers For Breast Cancer Imaging, Fanlin Kong

Dissertations and Theses (Open Access)

Breast cancer is the most common malignancy among women in the world. Its 5-year survival rate ranges from 23.4% in patients with stage IV to 98% in stage I disease, highlighting the importance of early detection and diagnosis. 18F-2-Fluoro-2-deoxy-glucose (18F-FDG), using positron emission tomography (PET), is the most common functional imaging tool for breast cancer diagnosis currently. Unfortunately, 18F-FDG-PET has several limitations such as poorly differentiating tumor tissues from inflammatory and normal brain tissues. Therefore, 18F-labeled amino acid-based radiotracers have been reported as an alternative, which is based on the fact that tumor cells uptake …


Brain Activation And Connectivity In Non-Disabled Multiple Sclerosis Patients, Rene A. Colorado Aug 2011

Brain Activation And Connectivity In Non-Disabled Multiple Sclerosis Patients, Rene A. Colorado

Dissertations and Theses (Open Access)

Multiple sclerosis (MS) is the most common demyelinating disease affecting the central nervous system. There is no cure for MS and current therapies have limited efficacy. While the majority of individuals with MS develop significant clinical disability, a subset experiences a disease course with minimal impairment even in the presence of significant apparent tissue damage on magnetic resonance imaging (MRI). The current studies combined functional MRI and diffusion tensor imaging (DTI) to elucidate brain mechanisms associated with lack of clinical disability in patients with MS. Recent evidence has implicated cortical reorganization as a mechanism to limit the clinical manifestation of …


In-Vivo Ct Dosimetry During Virtual Colonoscopy, Jonathon W. Mueller Aug 2011

In-Vivo Ct Dosimetry During Virtual Colonoscopy, Jonathon W. Mueller

Dissertations and Theses (Open Access)

Virtual colonoscopy (VC) is a minimally invasive means for identifying colorectal polyps and colorectal lesions by insufflating a patient’s bowel, applying contrast agent via rectal catheter, and performing multi-detector computed tomography (MDCT) scans. The technique is recommended for colonic health screening by the American Cancer Society but not funded by the Centers for Medicare and Medicaid Services (CMS) partially because of potential risks from radiation exposure. To date, no in‐vivo organ dose measurements have been performed for MDCT scans; thus, the accuracy of any current dose estimates is currently unknown.

In this study, two TLDs were affixed to the inner …


Characterization Of Optically Stimulated Luminescent Detectors In Photon & Proton Beams For Use In Anthropomorphic Phantoms, James R. Kerns Aug 2010

Characterization Of Optically Stimulated Luminescent Detectors In Photon & Proton Beams For Use In Anthropomorphic Phantoms, James R. Kerns

Dissertations and Theses (Open Access)

This study investigated characteristics of optically stimulated luminescent detectors (OSLDs) in protons, allowing comparison to thermoluminescent detectors, and to be implemented into the Radiological Physics Center’s (RPC) remote audit quality assurance program for protons, and for remote anthropomorphic phantom irradiations. The OSLDs used were aluminum oxide (Al2O3:C) nanoDots from Landauer, Inc. (Glenwood, Ill.) measuring 10x10x2 mm3. A square, 20(L)x20(W)x0.5(H) cm3 piece of solid water was fabricated with pockets to allow OSLDs and TLDs to be irradiated simultaneously and perpendicular to the beam. Irradiations were performed at 5cm depth in photons, and in the center of a 10 cm SOBP in …


An Implantable Mosfet Dosimeter Modified To Act As A Fiducial Marker, Joseph S. Dick Aug 2010

An Implantable Mosfet Dosimeter Modified To Act As A Fiducial Marker, Joseph S. Dick

Dissertations and Theses (Open Access)

In external beam radiation therapy, it is imperative that the prescribed dose is administered to the correct location and in the correct amount. Though several ex vivo methods of quality assurance are currently employed to achieve this goal, verifying that the correct dose is received within the patient in situ is impossible without the capability of measuring dose inside the patient. Recently, a method of measuring dose delivered within the patient has been developed, an implantable MOSFET dosimeter. This dosimeter is implanted within the patient and records the dose received. Since the dosimeter is implanted in the patient, it could …


Effect Of Acute Administration Of Angiopoietin-1 In Experimental Traumatic Spinal Cord Injury: Magnetic Resonance Imaging And Neurobehavioral Studies, Chirag B. Patel Aug 2010

Effect Of Acute Administration Of Angiopoietin-1 In Experimental Traumatic Spinal Cord Injury: Magnetic Resonance Imaging And Neurobehavioral Studies, Chirag B. Patel

Dissertations and Theses (Open Access)

Spinal cord injury (SCI) is a devastating condition that affects people in the prime of their lives. A myriad of vascular events occur after SCI, each of which contributes to the evolving pathology. The primary trauma causes mechanical damage to blood vessels, resulting in hemorrhage. The blood-spinal cord barrier (BSCB), a neurovascular unit that limits passage of most agents from systemic circulation to the central nervous system, breaks down, resulting in inflammation, scar formation, and other sequelae. Protracted BSCB disruption may exacerbate cellular injury and hinder neurobehavioral recovery in SCI.

In these studies, angiopoietin-1 (Ang1), an agent known to reduce …


Dynamic Chemical Shift Imaging For Image-Guided Thermal Therapy, Brian A. Taylor Aug 2010

Dynamic Chemical Shift Imaging For Image-Guided Thermal Therapy, Brian A. Taylor

Dissertations and Theses (Open Access)

Magnetic resonance temperature imaging (MRTI) is recognized as a noninvasive means to provide temperature imaging for guidance in thermal therapies. The most common method of estimating temperature changes in the body using MR is by measuring the water proton resonant frequency (PRF) shift. Calculation of the complex phase difference (CPD) is the method of choice for measuring the PRF indirectly since it facilitates temperature mapping with high spatiotemporal resolution. Chemical shift imaging (CSI) techniques can provide the PRF directly with high sensitivity to temperature changes while minimizing artifacts commonly seen in CPD techniques. However, CSI techniques are currently limited by …


Thoracic Radiotherapy Treatment Planning With Cine Pet/Ct, Adam C. Riegel May 2010

Thoracic Radiotherapy Treatment Planning With Cine Pet/Ct, Adam C. Riegel

Dissertations and Theses (Open Access)

Purpose: Respiratory motion causes substantial uncertainty in radiotherapy treatment planning. Four-dimensional computed tomography (4D-CT) is a useful tool to image tumor motion during normal respiration. Treatment margins can be reduced by targeting the motion path of the tumor. The expense and complexity of 4D-CT, however, may be cost-prohibitive at some facilities. We developed an image processing technique to produce images from cine CT that contain significant motion information without 4D-CT. The purpose of this work was to compare cine CT and 4D-CT for the purposes of target delineation and dose calculation, and to explore the role of PET in target …