Full-Text Articles in Radiology

Performance Evaluation Of Material Decomposition Using Rapid Kvp-Switching Dual-Energy Ct For Assessing Bone Mineral Density, John M. Wait May 2014

Performance Evaluation Of Material Decomposition Using Rapid Kvp-Switching Dual-Energy Ct For Assessing Bone Mineral Density, John M. Wait

Dissertations and Theses (Open Access)

Osteoporosis is diagnosed by assessing the bone mineral density (BMD) of the trabecular bone, and has previously been characterized with dual-energy x-ray absorptiometry (DXA) or single-energy computed tomography (SECT). Dual-energy computed tomography (DECT) is able to create two three-dimensional sets of images representing the densities of two materials in a given basis pair. DECT is theoretically capable of providing a true density measurement of trabecular bone material with the proper material basis pair.

Using the rapid kVp-switching GE HD750 scanner, the concentrations of various solutes were assessed in two-material syringe-phantoms in different experimental conditions with DECT material density images, SECT …


3d Visualization Architecture For Building Applications Leveraging An Existing Validated Toolkit, David A. Polyak Apr 2014

3d Visualization Architecture For Building Applications Leveraging An Existing Validated Toolkit, David A. Polyak

Master's Theses (2009 -)

The diagnostic radiology space and healthcare in general is a slow adopter of new software technologies and patterns. Despite the widespread embrace of mobile technology in recent years, altering the manner in which societies in developed countries live and communicate, diagnostic radiology has not unanimously adopted mobile technology for remote diagnostic review. Desktop applications in the diagnostic radiology space commonly leverage a validated toolkit. Such toolkits not only simplify desktop application development but minimize the scope of application validation. For these reasons, such a toolkit is an important piece of a company’s software portfolio. This thesis investigated an approach for …


Skin Lesion Extraction And Its Application, Yanliang Gu Jan 2014

Skin Lesion Extraction And Its Application, Yanliang Gu

Dissertations, Master's Theses and Master's Reports - Open

In this thesis, I study skin lesion detection and its applications to skin cancer diagnosis. A skin lesion detection algorithm is proposed. The proposed algorithm is based color information and threshold. For the proposed algorithm, several color spaces are studied and the detection results are compared. Experimental results show that YUV color space can achieve the best performance. Besides, I develop a distance histogram based threshold selection method and the method is proven to be better than other adaptive threshold selection methods for color detection. Besides the detection algorithms, I also investigate GPU speed-up techniques for skin lesion extraction and …


Cervical Cancer Histology Image Feature Extraction And Classification, Peng Guo Jan 2014

Cervical Cancer Histology Image Feature Extraction And Classification, Peng Guo

Masters Theses

"Cervical cancer, the second most common cancer affecting women worldwide and the most common in developing countries can be cured if detected early and treated. Expert pathologists routinely visually examine histology slides for cervix tissue abnormality assessment. In previous research, an automated, localized, fusion-based approach was investigated for classifying squamous epithelium into Normal, CIN1, CIN2, and CIN3 grades of cervical intraepithelial neoplasia (CIN) based on image analysis of 62 digitized histology images obtained through the National Library of Medicine. In this research, CIN grade assessments from two pathologists are analyzed and are used to facilitate atypical cell concentration feature development …


Use Of An Electrical Impedance Tomography Method To Detect And Track Fractures In A Gelatin Medium, Evan G. Lucas Jan 2014

Use Of An Electrical Impedance Tomography Method To Detect And Track Fractures In A Gelatin Medium, Evan G. Lucas

Dissertations, Master's Theses and Master's Reports - Open

Electrical impedance tomography is applied to the problem of detecting, locating, and tracking fractures in ballistics gelatin. The hardware developed is intended to be physically robust and based on off-the-shelf hardware. Fractures were created in two separate ways: by shooting a .22 caliber bullet into the gelatin and by injecting saline solution into the gelatin. The .22 caliber bullet created an air gap, which was seen as an increase in resistivity. The saline solution created a fluid filled gap, which was seen as a decrease in resistivity. A double linear array was used to take data for each of the …


Three‐Dimensional Brain Mri For Dbs Patients Within Ultra‐Low Radiofrequency Power Limits, Subhendra N. Sarkar, Efstathios Papavassiliou, David Hackney, David Alsop, Ananth Madhuranthakam, Ludy Shih, Reed Busse, Susan Laruche, Rafeeque Bhadelia Jan 2014

Three‐Dimensional Brain Mri For Dbs Patients Within Ultra‐Low Radiofrequency Power Limits, Subhendra N. Sarkar, Efstathios Papavassiliou, David Hackney, David Alsop, Ananth Madhuranthakam, Ludy Shih, Reed Busse, Susan Laruche, Rafeeque Bhadelia

Publications and Research

Background: For patients with deep brain stimulators (DBS), local absorbed radiofrequency (RF) power is unknown and is much higher than what the system estimates. We developed a comprehensive, highquality brain magnetic resonance imaging (MRI) protocol for DBS patients utilizing three-dimensional (3D) magnetic resonance sequences at very low RF power. Methods: Six patients with DBS were imaged (10 sessions) using a transmit/receive head coil at 1.5 Tesla with modified 3D sequences within ultra-low specific absorption rate (SAR) limits (0.1 W/kg) using T2, fast fluid-attenuated inversion recovery (FLAIR) and T1- weighted image contrast. Tissue signal and tissue contrast from the low-SAR images …


An Investigation Of Nurbs-Based Deformable Image Registration, Travis J. Jacobson Jan 2014

An Investigation Of Nurbs-Based Deformable Image Registration, Travis J. Jacobson

Theses and Dissertations

Deformable image registration (DIR) is an essential tool in medical image processing. It provides a means to combine image datasets, allowing for intra-subject, inter-subject, multi-modality, and multi-instance analysis, as well as motion detection and compensation. One of the most popular DIR algorithms models the displacement vector field (DVF) as B-splines, a sum of piecewise polynomials with coefficients that enable local shape control. B-splines have many advantageous properties in the context of DIR, but they often struggle to adequately model steep local gradients and discontinuities. This dissertation addresses that limitation by proposing the replacement of conventional B-splines with a generalized formulation …


A Nonrigid Registration Method For Correcting Brain Deformation Induced By Tumor Resection, Yixun Liu, Chengjun Yao, Fotis Drakopoulos, Jinsong Wu, Liangfu Zhou, Nikos Chrisochoides Jan 2014

A Nonrigid Registration Method For Correcting Brain Deformation Induced By Tumor Resection, Yixun Liu, Chengjun Yao, Fotis Drakopoulos, Jinsong Wu, Liangfu Zhou, Nikos Chrisochoides

Computer Science Faculty Publications

Purpose: This paper presents a nonrigid registration method to align preoperative MRI with intraoperative MRI to compensate for brain deformation during tumor resection. This method extends traditional point-based nonrigid registration in two aspects: (1) allow the input data to be incomplete and (2) simulate the underlying deformation with a heterogeneous biomechanical model.

Methods: The method formulates the registration as a three-variable (point correspondence, deformation field, and resection region) functional minimization problem, in which point correspondence is represented by a fuzzy assign matrix; Deformation field is represented by a piecewise linear function regularized by the strain energy of a heterogeneous biomechanical …


Scanned Ion Beam Therapy For Thoracic Tumors, John Gordon Eley Dec 2013

Scanned Ion Beam Therapy For Thoracic Tumors, John Gordon Eley

Dissertations and Theses (Open Access)

Although frequently cured of Hodgkin lymphoma, adolescents and young adults can develop radiation induced second cancers. These patients could potentially benefit from scanned ion radiotherapy yet likely would require motion mitigation strategies. In theory, four-dimensional (4D) optimization of ion beam fields for individual motion states of respiration can enable superior sparing of healthy tissue near moving targets, compared to other motion mitigation strategies. Furthermore, carbon-ion therapy can sometimes provide greater relative biological effectiveness (RBE) for cell sterilization in a target but nearly equivalent RBE in tissue upstream of the target, compared to proton therapy. Thus, we expected that for some …


Impact Of Varied Low Resolution Phantoms On Intensity Modulated Proton Therapy Dose Distributions, Aarohi Shyam Padhye Jan 2013

Impact Of Varied Low Resolution Phantoms On Intensity Modulated Proton Therapy Dose Distributions, Aarohi Shyam Padhye

Theses Digitization Project

The primary purpose of this thesis is to discuss the usefulness of image segmentation techniques in creating accurate proton dose distribution plans. The calculation of the proton dose distribution has to take into account the material (tissue, bone, brain) in the treatment area of the patients body.


Stereotactic Localization And Targeting Accuracy For Experimental Proton Radiosurgery, Yin Chen Jan 2013

Stereotactic Localization And Targeting Accuracy For Experimental Proton Radiosurgery, Yin Chen

Theses Digitization Project

The purpose of this study was to improve an existing experimental proton radiosurgery system at Loma Linda University Medical Center to reach sub-millimeter accuracy before proton radiosurgery with narrow beams can be used in a clinical trial. Protons, different from photons (i.e., x-rays or gamma rays), are charged with particles that slow down in matter and release a burst of energy near the end of their range (maximum depth of penetration), which is called the Bragg peak, named after the physicist William Henry Bragg who discovered it in 1903. Photon beams deliver most doses over a large area near the …


Fiducial-Free Alignment Verification Techniques For Intracranial Radiosurgery, Kenneth Matthew Williams Jan 2013

Fiducial-Free Alignment Verification Techniques For Intracranial Radiosurgery, Kenneth Matthew Williams

Theses Digitization Project

This thesis serves as the basis for a method using image registration to automate patient alignment in an effort to eliminate the dependency on the fiducial markers as well as improve the accuracy efficiency of the alignment process. Proton beams are an external beam modality of radiation therapy that can be used effectively for radiosurgical applications due to the dosimetry advantage of the Bragg peak. The Bragg peak is a phenomenon exploited by proton beam therapy to concentrate the effect of the beams on the tumor while minimizing damage to critical structures and other health tissues within the patient.


A New Phantom And Gradient Isocenter Estimation For Magnetic Resonance Imaging Distortion Correction, Zongqi Cai Jan 2013

A New Phantom And Gradient Isocenter Estimation For Magnetic Resonance Imaging Distortion Correction, Zongqi Cai

Theses Digitization Project

The purpose of this study was to develop and implement a numerical software based method that can accurately correct the distortion of MR images generated by 3T MRI scanner. To accomplish this, a new phantom has been designed from scratch to capture the distortions inside 3T MRI scanner. An algorithm has been developed, based on the unique geometric feature of the new phantom, to estimate the location of gradient isocenter of the magnetic field inside 3T MRI scanner for the first time.


Alternative Hull Detection Techniques For Preprocessing In Proton Computed Tomography Reconstruction, Blake Edward Schultze Jan 2013

Alternative Hull Detection Techniques For Preprocessing In Proton Computed Tomography Reconstruction, Blake Edward Schultze

Theses Digitization Project

The purpose of this study was to develop computationally efficient hull detection techniques appropriate for image reconstruction using sparse matrices. The hull detection techniques investigated were space carving (SC), modified space carving (MSC), and space modeling (SM) and these were compared to the cone-beam version of filtered back projection (FBP) algorithm in terms of their computation time and the quality of the object hull they produced.


Potential For High Resolution Microscintigraphy Using Polycapillary Optics, Patrick Richard Conlon Jan 2013

Potential For High Resolution Microscintigraphy Using Polycapillary Optics, Patrick Richard Conlon

Legacy Theses & Dissertations (2009 - 2024)

Scintigraphy, also known as nuclear imaging, is the process of imaging an object that has been labeled with a radioactive material. A novel technique employing polycapillary optics for very high - resolution scintigraphy is presented. The small channel size and angular selectivity of polycapillary optics allow them to act as multiple-hole collimators and be used with high - resolution detectors. The ability of the optics to work with high resolution detectors allow the system to discriminate against scatter, thus negating the need for energy sensitive detectors, which are known to have poor resolution. Therefore the use of polycapillary optics presents …


Facial Type Analysis Comparison Between Mri, Cbct, And Lateral Cephalometrics, Matthew A. Sanders Sep 2010

Facial Type Analysis Comparison Between Mri, Cbct, And Lateral Cephalometrics, Matthew A. Sanders

Loma Linda University Electronic Theses, Dissertations & Projects

Introduction: Single Cephalometric measurements are comparable between Cone Beam Computed Tomography (CBCT), Magnetic Resonance Imaging (MRl) and Conventional Lateral Cephalometric (LC) imaging methods. This study evaluated the agreement between the three imaging methods in facial type analysis (using a composite of 5 cephalometric measures).

Methods and Materials: Twenty-two subjects participated in this study. Cranial images were generated via three modalities: LC, CBCT and MRl. Cephalometric landmarks were identified on the three images per subject and a facial type analysis performed. An equally weighted facial type calculation composed of 5 cephalometric measurements (facial axis, facial depth, mandibular plane, lower face height, …


Creating Prediction Models For Obstructive Sleep Apnea Based On Gender, Jeffrey Hwang Sep 2010

Creating Prediction Models For Obstructive Sleep Apnea Based On Gender, Jeffrey Hwang

Loma Linda University Electronic Theses, Dissertations & Projects

Introduction: Obstructive sleep apnea (OSA) is a common chronic disorder that is characterized by repetitive episodes of airflow cessation or reduction occurring during sleep as a result of partial or complete upper airway obstruction. These recurrent events have a tremendous impact on the cardiovascular system with a multitude of dangerous consequences. Numerous studies have been conducted determining etiological risk factors for OSA including anatomical predictors which have been observed with multiple imaging techniques. Cone beam computed tomography (CBCT) is a low-radiation mode of imaging that can be used to accurately identify anatomical landmarks and measure craniofacial relationships and airway dimensions. …


Microct Study Of Critical-Sized Defects Restored With A New Rhbmp-2 Carrier, Joanne S. Kim Sep 2010

Microct Study Of Critical-Sized Defects Restored With A New Rhbmp-2 Carrier, Joanne S. Kim

Loma Linda University Electronic Theses, Dissertations & Projects

Introduction: Regenerating bone in critical-sized maxillofacial osseous defects remains a challenge. The utilization of recombinant human bone morphogenetic protein-2 (rhBMP-2) to form new bone has been shown to be a promising alternative to autogenous bone grafts, and the development of a carrier matrix to effectively deliver the rhBMP-2 has been identified as the critical factor necessary for the successful clinical application of rhBMP-2. The objective of this study was to perform a microCT analysis to examine the density of reconstructed bone using different rhBMP-2 carriers in critical-sized defects.

Material and Methods: Critical-sized defects (approximately 2.5 cm) were created in the …


High Pressure Liquid Chromatography Studies Of The Reaction Of Platinum Complexes With Peptides, Khaja Muneeruddin Aug 2010

High Pressure Liquid Chromatography Studies Of The Reaction Of Platinum Complexes With Peptides, Khaja Muneeruddin

Masters Theses & Specialist Projects

Platinum complexes (cisplatin, carboplatin and oxaliplatin) are effective anticancer agents. However the major drawbacks of platinum chemotherapy are toxic side effects and resistance. The affinity of platinum complexes to sulfur donor ligands of side chains of methionine and cysteine amino acids was assumed to be responsible for toxicity and resistance. Recently, it was found that the reaction of platinum complex with proteins containing sulfur donor ligands could actually favor its anticancer activity. Copper transporter 1 (Ctr 1), a protein involved in the transport of copper into the cell, also helps in the influx of cisplatin by binding to N-terminal domain …


Characterization Of Optically Stimulated Luminescent Detectors In Photon & Proton Beams For Use In Anthropomorphic Phantoms, James R. Kerns Aug 2010

Characterization Of Optically Stimulated Luminescent Detectors In Photon & Proton Beams For Use In Anthropomorphic Phantoms, James R. Kerns

Dissertations and Theses (Open Access)

This study investigated characteristics of optically stimulated luminescent detectors (OSLDs) in protons, allowing comparison to thermoluminescent detectors, and to be implemented into the Radiological Physics Center’s (RPC) remote audit quality assurance program for protons, and for remote anthropomorphic phantom irradiations. The OSLDs used were aluminum oxide (Al2O3:C) nanoDots from Landauer, Inc. (Glenwood, Ill.) measuring 10x10x2 mm3. A square, 20(L)x20(W)x0.5(H) cm3 piece of solid water was fabricated with pockets to allow OSLDs and TLDs to be irradiated simultaneously and perpendicular to the beam. Irradiations were performed at 5cm depth in photons, and in the center of a 10 cm SOBP in …


An Implantable Mosfet Dosimeter Modified To Act As A Fiducial Marker, Joseph S. Dick Aug 2010

An Implantable Mosfet Dosimeter Modified To Act As A Fiducial Marker, Joseph S. Dick

Dissertations and Theses (Open Access)

In external beam radiation therapy, it is imperative that the prescribed dose is administered to the correct location and in the correct amount. Though several ex vivo methods of quality assurance are currently employed to achieve this goal, verifying that the correct dose is received within the patient in situ is impossible without the capability of measuring dose inside the patient. Recently, a method of measuring dose delivered within the patient has been developed, an implantable MOSFET dosimeter. This dosimeter is implanted within the patient and records the dose received. Since the dosimeter is implanted in the patient, it could …


Dynamic Chemical Shift Imaging For Image-Guided Thermal Therapy, Brian A. Taylor Aug 2010

Dynamic Chemical Shift Imaging For Image-Guided Thermal Therapy, Brian A. Taylor

Dissertations and Theses (Open Access)

Magnetic resonance temperature imaging (MRTI) is recognized as a noninvasive means to provide temperature imaging for guidance in thermal therapies. The most common method of estimating temperature changes in the body using MR is by measuring the water proton resonant frequency (PRF) shift. Calculation of the complex phase difference (CPD) is the method of choice for measuring the PRF indirectly since it facilitates temperature mapping with high spatiotemporal resolution. Chemical shift imaging (CSI) techniques can provide the PRF directly with high sensitivity to temperature changes while minimizing artifacts commonly seen in CPD techniques. However, CSI techniques are currently limited by …


Optimizing Radiology Peer Review: A Mathematical Model For Selecting Future Cases Based On Prior Errors, Yun Robert Sheu, Elie Feder, Igor Balsim, Victor F. Levin, Andrew G. Bleicher, Barton F. Branstetter Iv Jun 2010

Optimizing Radiology Peer Review: A Mathematical Model For Selecting Future Cases Based On Prior Errors, Yun Robert Sheu, Elie Feder, Igor Balsim, Victor F. Levin, Andrew G. Bleicher, Barton F. Branstetter Iv

Publications and Research

Introduction: Peer review is an essential process for physicians because it facilitates improved quality of patient care and continuing physician learning and improvement. However, peer review often is not well received by radiologists, who note that it is time intensive, subjective, and lacks demonstrable impact on patient care. Current advances in peer review include the RADPEER system with its standardization of discrepancies and incorporation of the peer review process into the PACS itself. Our purpose was to build on RADPEER and similar systems by using a mathematical model to optimally select the types of cases to be reviewed, for each …


Thoracic Radiotherapy Treatment Planning With Cine Pet/Ct, Adam C. Riegel May 2010

Thoracic Radiotherapy Treatment Planning With Cine Pet/Ct, Adam C. Riegel

Dissertations and Theses (Open Access)

Purpose: Respiratory motion causes substantial uncertainty in radiotherapy treatment planning. Four-dimensional computed tomography (4D-CT) is a useful tool to image tumor motion during normal respiration. Treatment margins can be reduced by targeting the motion path of the tumor. The expense and complexity of 4D-CT, however, may be cost-prohibitive at some facilities. We developed an image processing technique to produce images from cine CT that contain significant motion information without 4D-CT. The purpose of this work was to compare cine CT and 4D-CT for the purposes of target delineation and dose calculation, and to explore the role of PET in target …


Application Of X-Ray Diffraction To Material Analysis And Medical Imaging, Wei Zhou Jan 2010

Application Of X-Ray Diffraction To Material Analysis And Medical Imaging, Wei Zhou

Legacy Theses & Dissertations (2009 - 2024)

Powder diffraction is commonly used to determine the structures of both inorganic and organic materials. The angle and intensity of the diffraction (also called coherent scatter) peak depends on the nanostructure of the material. When no x-ray optic is used, the peak width broadens, and hence the resolution worsens, as the sample area is increased. However, a small sample area gives low diffracted signal intensity, particularly for thin films and for organic materials, which have low diffraction cross sections. X-ray optics can be used in x-ray powder diffraction to increase the diffraction intensity, thus decreasing exposure times. For a small …


Using Cone Beam Computed Tomography To Identify A Prediction Model For Obstructive Sleep Apnea, Jodi Parker Sep 2009

Using Cone Beam Computed Tomography To Identify A Prediction Model For Obstructive Sleep Apnea, Jodi Parker

Loma Linda University Electronic Theses, Dissertations & Projects

Introduction: Obstructive Sleep Apnea (OSA) patients have increased risk of morbidity and mortality. Early diagnosis may reduce morbidity and mortality. Prediction of OSA from imaging may help to identify OSA patients earlier in life. CBCT can be used for OSA diagnostic imaging due to its three-dimensional (3D) visualization of the upper airway and craniofacial complex. Magnification associated with conventional 2D radiography is eliminated with CBCT, and radiation to the patient is significantly less than previous modalities used to measure craniofacial & airway measurements associated with OSA. During a CBCT scan, the patient's image is taken supine, rather than the upright …


Observer Reliability Of Cephalometric Landmark Identification On 3-D Mr Images, Michael S. Pollack Sep 2009

Observer Reliability Of Cephalometric Landmark Identification On 3-D Mr Images, Michael S. Pollack

Loma Linda University Electronic Theses, Dissertations & Projects

Introduction: Cephalometric analysis is a cornerstone of orthodontic diagnosis, yet much information is lost when 3-dimensional structures are assessed with 2-dimensional methods. CBCT offers 3-dimensional imaging but at the cost of higher levels of ionizing radiation. Magnetic resonance imaging provides 3-dimensional imaging without ionizing radiation and additionally imparts visualization of soft tissue structures. Prior to employing MR images for cephalometric analysis, reliability of landmark identification must be assessed. The purpose of this study was to evaluate intra- and interobserver reliability in 3-dimensional landmark identification using MR images.

Materials and Methods: Fifteen cranial MR images (3.0 T, MP-RAGE) from subjects between …


Cephalometric Analysis Using Magnetic Resonance Imaging, Wade A. Williams Sep 2008

Cephalometric Analysis Using Magnetic Resonance Imaging, Wade A. Williams

Loma Linda University Electronic Theses, Dissertations & Projects

Purpose: The purpose of this study was to determine if T1-weighted 3D magnetic resonance images performed at 3.0 Tesla could be used to conduct routine orthodontic cephalometric analysis.

Methods: Three cranial imaging methods were compared using sixteen non-growing subjects (10 male and 6 female) who were not claustrophobic, did not have any metallic restorations on the distal of first molars, had no medical implants and the female subjects were not pregnant. Sagittal cranial images were produced by three methods: (1) a digital lateral cephalometric (LC) radiograph (Orthophos XG Plus, SironaTM, Bensheim, Germany), (2) a 12-inch FOV cone beam …


Orthodontic Mini-Implant Failure: Assessing The Relationship To Bone Quality Using Qcbct, Joshua Schneider Sep 2008

Orthodontic Mini-Implant Failure: Assessing The Relationship To Bone Quality Using Qcbct, Joshua Schneider

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this study was to evaluate the cortical bone thickness (mm), cortical bone density (HU), and trabecular bone density (HU) of mini-implants sites in both the maxilla and mandible using QCBCT to determine if they had any effect on mini-implant failure rate. Patient characteristics (age, gender, facial type), mini-implant characteristics (date of placement, manufacturer, length, and diameter), and the mini-implant site (region) were also evaluated. One hundred and six mini-implants in 50 consecutive patients with complete patient records, CBCT information, and T1 radiographs were included in the study. Thirty-four of the 106 mini-implants were considered "failures" resulting in …


The Comparative Radiopacity Between Primary And Permanent Teeth, Robert C. Lee Sep 2008

The Comparative Radiopacity Between Primary And Permanent Teeth, Robert C. Lee

Loma Linda University Electronic Theses, Dissertations & Projects

Purpose: This in vitro study compared the radiopacity between human primary and permanent enamel and dentin. It also compared the radiopacity between human anterior and posterior teeth.

Methods: Extracted primary and permanent teeth were used in this study. One mm enamel and one mm dentin slices were cut from each extracted tooth. Radiographs were taken of each enamel and dentin specimen 1 mm in thickness along with an aluminum step-wedge using procedures specified in International Standards Organization (ISO) 4049:2000. A densitometer was used to measure the Optical Density (OD) of the radiographs of the specimen and the accompanying aluminum step-wedge. …