Open Access. Powered by Scholars. Published by Universities.®
- Discipline
- Keyword
-
- Proton therapy (7)
- Proton beam therapy (6)
- Radiotherapy (4)
- Breast cancer (2)
- Lung neoplasms (2)
-
- Prostate cancer (2)
- SPArc (2)
- VMAT beam complexity (2)
- (SPArc) (1)
- (SSWT)Spot-Scanning proton arc (1)
- Adaptive radiotherapy (1)
- Adjuvant therapy (1)
- Administration and Dosage (1)
- Axillary node (1)
- BOC-IMPTLET (1)
- Blood dosimetry (1)
- Brachytherapy (1)
- Brain metastases (1)
- Breast neoplasms (1)
- Cancer Cells (1)
- Central limit theorem (1)
- Cervical cancer (1)
- Cholangioscopy (1)
- Collimator rotation (1)
- Combinatorial rigid registration optimization (CORRO) (1)
- Deep learning (1)
- Deep-learning (1)
- Direct Thoracic Tumor Immobilization (1)
- Dose (1)
- Electron beams (1)
- Publication Type
Articles 1 - 30 of 77
Full-Text Articles in Radiation Medicine
Perceptions Of Radiology Residency Staffing Models Across Years Of Training, Alex Zhang, Alexander Swantek, Adela Pouzar, Sayf Al-Katib
Perceptions Of Radiology Residency Staffing Models Across Years Of Training, Alex Zhang, Alexander Swantek, Adela Pouzar, Sayf Al-Katib
Posters
Case staffing is the primary method by which radiology residencies teach at the workstation. Despite this, the styles and methods for how staffing is performed have not yet been comprehensively described. Understanding these models and evaluating resident perspectives can inform best practices and enhance radiology education.
Comparison Of Magnetic Resonance Imaging (Mri) And Endoluminal Endoscopic Ultrasound (Eus) For Restaging Rectal Cancer After Neoadjuvant Chemotherapy, Judy Sheffeh, Amr Aref, Mohammed Barawi, Amer Alame, Amer Zeni, Ernesto R. Drelichman, Jasneet S. Bhullar
Comparison Of Magnetic Resonance Imaging (Mri) And Endoluminal Endoscopic Ultrasound (Eus) For Restaging Rectal Cancer After Neoadjuvant Chemotherapy, Judy Sheffeh, Amr Aref, Mohammed Barawi, Amer Alame, Amer Zeni, Ernesto R. Drelichman, Jasneet S. Bhullar
Conference Presentation Abstracts
Purpose/Background: Given the high incidence and mortality of rectal cancer, accurate staging and restaging are crucial for guiding optimal interventions. However, no consensus exists on the best imaging modality for restaging after neoadjuvant chemoradiotherapy. This study aims to compare MRI and EUS in the restaging of rectal cancer following neoadjuvant chemoradiotherapy.
Methods/Interventions: We conducted a prospective observational study and enrolled patients with rectal cancer. EUS and MRI were performed at diagnosis for initial staging and repeated after neoadjuvant chemotherapy and chemoradiotherapy for restaging. A total of 43 patients were enrolled, with 25 patients (10 males, 15 females) with rectal cancer …
Treatment Outcomes Following Tme For Biologically Unfavorable Locally Advanced Rectal Cancer, Maryam Aleissa, Amr Aref, Hussein Gharib, Ernesto R. Drelichman, Amer Zeni, Amer Alame, Jasneet S. Bhullar
Treatment Outcomes Following Tme For Biologically Unfavorable Locally Advanced Rectal Cancer, Maryam Aleissa, Amr Aref, Hussein Gharib, Ernesto R. Drelichman, Amer Zeni, Amer Alame, Jasneet S. Bhullar
Conference Presentation Abstracts
Purpose/Background: Many centers now offer organ preservation for selected patients with locally advanced rectal cancer. Our group initiated three Phase II trials to assess the safety of this approach in various clinical scenarios. Nonoperative management was recommended only for patients achieving complete clinical response CCR)after total neoadjuvant therapy TNT. Total mesorectal excision TME was advised when CCR was not achieved (primary TME), following residual cancer after Limited Local Excision LLE (completion TME), or after tumor recurrence/regrowth post-LLE or watchful waiting WW (salvage TME). This study examines treatment outcomes following primary or salvage TME in these biologically unfavorable cases.
Methods/Interventions: Each …
Advances In Minimally Invasive Hepatobiliary Interventions For Non-Operative Candidates, Tulasi Talluri, Philip Cieplinski, Kristian Loveridge
Advances In Minimally Invasive Hepatobiliary Interventions For Non-Operative Candidates, Tulasi Talluri, Philip Cieplinski, Kristian Loveridge
Posters
Cholangioscopy is a technique used for diagnosing and treating patients with pathologies of the gallbladder, liver, and pancreas. It has been available since 1976 but with limited use in interventional radiology (IR) due to issues with steerability, irrigation capabilities, requirement for more than one operator, and poor percutaneous access options; however, direct intraluminal visualization of the gallbladder, common bile ducts, and even the ampulla and duodenum has become more practical with the advent of single operator percutaneous systems. Access to the biliary system can now be made through smaller 11 French sheath/delivery systems allowing for improved maneuverability into the common …
Toxicity And Clinical Outcomes Following Brachytherapy Using 3-D Dosimetric Planning In Patients With Cervical Cancer: An Institutional Experience, Nikita M. Patel, Jacob F. Oyeniyi, Maha Saada Jawad
Toxicity And Clinical Outcomes Following Brachytherapy Using 3-D Dosimetric Planning In Patients With Cervical Cancer: An Institutional Experience, Nikita M. Patel, Jacob F. Oyeniyi, Maha Saada Jawad
Posters
• Cervical cancer is the most common gynecological cancer worldwide.1
• The standard of care for locally advanced cervical cancer (LACC) includes primary chemoradiation, brachytherapy, and external-beam radiotherapy.2
• Brachytherapy (BT) involves the targeted delivery of radiation to the cervix (Fig 1). However, radiation can be toxic to surrounding structures, most commonly affecting the gynecological, genitourinary, and gastrointestinal systems.3
• Historically, brachytherapy was planned using a 2-D approach, which had limitations in accuracy and increased toxicity to the adjacent bowel and bladder. 3-D planning using CT or MRI has been shown to have improved dose precision and reduced toxicity.4
• …
Comparison Of Two Adjuvant High-Dose Rate Vaginal Cuff Brachytherapy Dose Fractionation Regimens For Treatment Of Early-Stage Uterine Cancer, Catherine Raciti, Hong Ye, Allison J. Hazy, Maha Saada Jawad
Comparison Of Two Adjuvant High-Dose Rate Vaginal Cuff Brachytherapy Dose Fractionation Regimens For Treatment Of Early-Stage Uterine Cancer, Catherine Raciti, Hong Ye, Allison J. Hazy, Maha Saada Jawad
Posters
• Endometrial cancer is the most common gynecologic malignancy in the United States, with peak incidence at 63 years of age.¹
• PORTEC-2 trial established VBT alone as an effective modality for select high-intermediate risk patients.2
• There was no strict ABS guideline for dose fractionation; our institution adopted a 30Gy in 6 fractions regimen based on radiobiological calculations.3,4
• COVID-19 pandemic led to a shift towards 22Gy in 4 fractions
• Objective: Compare oncologic outcomes and toxicity between the 30Gy/6fx and 22Gy/4fx regimens.
• Hypothesis: Both regimens are well-tolerated and equally effective.
• Impact: Findings will inform clinical practice …
Source Model Parameters For Beam Commissioning Of Scanning Proton Therapy Treatment Planning System: Multi-Institutional Survey And Analysis, Chih-Wei Chang, Liyong Lin, Lei Dong, Heng Li, Jan Po Schuemann, Jiajian Shen, Xuanfeng Ding
Source Model Parameters For Beam Commissioning Of Scanning Proton Therapy Treatment Planning System: Multi-Institutional Survey And Analysis, Chih-Wei Chang, Liyong Lin, Lei Dong, Heng Li, Jan Po Schuemann, Jiajian Shen, Xuanfeng Ding
Conference Presentation Abstracts
Purpose: To create a beamline-specific repository of source model parameters and beam commissioning data for scanning proton therapy (PT) treatment planning system (TPS).
Methods: We surveyed 28 PT centers, collecting beam commissioning source model parameters of diverse beamlines from different vendors: Hitachi, IBA, Varian, Mevion. Parameters included (i) beam meterset calibration in protons per MU, (ii) in-air spot size at isocenter in terms of standard deviation in x- (crossline, σx) and y- (inline, σy) directions, (iii) in-air angular spread at isocenter in x-direction (θx) and y-direction (θy). We plotted each parameter as …
Loco-Regional Irradiation In Patients With Biopsy-Proven Axillary Node Involvement At Presentation Who Become Pathologically Node-Negative After Neoadjuvant Chemotherapy: Primary Outcomes Of Nrg Oncology/Nsabp B-51/Rtog 1304, E Mamounas, H Bandos, J White, T Julian, A Khan, S Shaitelman, M Torres, Frank Vicini, P Ganz, Andrew Muskovitz
Loco-Regional Irradiation In Patients With Biopsy-Proven Axillary Node Involvement At Presentation Who Become Pathologically Node-Negative After Neoadjuvant Chemotherapy: Primary Outcomes Of Nrg Oncology/Nsabp B-51/Rtog 1304, E Mamounas, H Bandos, J White, T Julian, A Khan, S Shaitelman, M Torres, Frank Vicini, P Ganz, Andrew Muskovitz
Conference Presentation Abstracts
No abstract provided.
Nrg-Br008: A Phase Iii Randomized Trial Of Radiotherapy Optimization For Low-Risk Her2-Positive Breast Cancer (Hero), L Braunstein, M Mitchell, H Bandos, W Sikov, A Khan, Peter Chen, P Ganz, R Jagsi, J White, R Cecchini
Nrg-Br008: A Phase Iii Randomized Trial Of Radiotherapy Optimization For Low-Risk Her2-Positive Breast Cancer (Hero), L Braunstein, M Mitchell, H Bandos, W Sikov, A Khan, Peter Chen, P Ganz, R Jagsi, J White, R Cecchini
Conference Presentation Abstracts
Background: Breast radiotherapy (RT) is the standard of care for patients with early-stage breast cancer (BC) who undergo breast-conserving surgery (BCS). However, the magnitude of benefit of RT is less clear in BCS patients with low-risk disease who receive effective systemic therapy. Among patients with early-stage HER2-positive (HER2+) BC, 10-year locoregional recurrence has been reported as low as 1.5% following BCS, adjuvant chemotherapy and HER2-targeted therapy, and RT. Given these exceedingly favorable outcomes, with the addition of HER2-directed therapy, we seek to evaluate the feasibility of omitting RT among patients with early-stage HER2+ BC following BCS and appropriate systemic therapy. …
Investigate The Delivery Efficiency Improvement For Sparc Compared To Impt, Peilin Liu, B A. De Jong, S Chang, Lewei Zhao, G Liu, Craig Stevens, Rohan Deraniyagala, E W. Korevaar, J A. Langendijk, Xiaoqiang Li, Xuanfeng Ding
Investigate The Delivery Efficiency Improvement For Sparc Compared To Impt, Peilin Liu, B A. De Jong, S Chang, Lewei Zhao, G Liu, Craig Stevens, Rohan Deraniyagala, E W. Korevaar, J A. Langendijk, Xiaoqiang Li, Xuanfeng Ding
Conference Presentation Abstracts
Purpose: To assess the efficiency improvement of SPArc compared to IMPT in proton clinical operation.Methods: A random clinical operation day at a proton therapy center with a two room system. Aa total of 10 Head & Neck cancer cases treated on Jan 6th, 2021were selected and SPArc plans were generated for all the cases with similar target coverage and dose constraints of organ at risk (OARs). 3% range uncertainties and 3mm setup uncertainties were applied for robust optimization. The log files of clinical IMPT were exported to calculate true treatment delivery time. The machine-specific delivery sequence model was utilized to …
A Comprehensive Investigation Of Linear Energy Transfer Optimization Effectiveness In Intensity-Modulated Proton Therapy Via Alternating Direction Method Of Multipliers (Impt Let-Admm), Q Fan, G Liu, Lewei Zhao, Xiaoqiang Li, Xuanfeng Ding, S Dai
A Comprehensive Investigation Of Linear Energy Transfer Optimization Effectiveness In Intensity-Modulated Proton Therapy Via Alternating Direction Method Of Multipliers (Impt Let-Admm), Q Fan, G Liu, Lewei Zhao, Xiaoqiang Li, Xuanfeng Ding, S Dai
Conference Presentation Abstracts
Linear energy transfer (LET)-guided optimization in intensity-modulated proton therapy (IMPT) via alternating direction method of multipliers (ADMM) has the potential to improve its biological effectiveness (IMPTLET- ADMM), in which the LET distribution in target can be escalated, while the LET distribution in the organs at risk can be mitigated. This study aims to quantitatively investigate the effectiveness of LET optimization in IMPT via ADMM with different solvers in its iteration loop. Methods: The clinical dose-volume-histogram (DVH) constraint noted dose sub-problem and clinical LET -volume-histogram (LVH) constraint noted LET sub-problem are combined to generate a composite objective function, which is available …
Particle Arc Single-Isocenter Stereotactic Radiosurgery Of Multiple Brain Metastases, L Volz, S Mein, T Tessonnier, Peilin Liu, A Mairani, M Durante, Xuanfeng Ding, C Graeff, T Li
Particle Arc Single-Isocenter Stereotactic Radiosurgery Of Multiple Brain Metastases, L Volz, S Mein, T Tessonnier, Peilin Liu, A Mairani, M Durante, Xuanfeng Ding, C Graeff, T Li
Conference Presentation Abstracts
Purpose: To develop spot-scanning proton (SPArc) and heavy ion (SHArc) arc therapy for single-isocenter stereotatic radiosurgery (SISRS) of multiple brain metastases (MBMs). First results achieved with dedicated planning infrastructure are compared to state-of-the -art volumetric modulated photon arc therapy (HA-VMAT). Methods: A multi-institutional collaboration was established to develop bespoke SPArc and SHArc SISRS infrastructure with available research and commercial treatment planning systems. Devised planning and delivery methods considered dedicated energy, spot, and multi-arc selection strategies. SPArc and SHArc (carbon and helium ions) plans were generated for MBM patients exhibiting 3-12 intracranial lesions with GTV volumes between 0.03ccm and 19.8ccm, at …
The Clinical Usability, Efficiency, And Accuracy Of Combining Deep-Learning-Based Synthetic Ct And Auto-Contouring For Daily Cbct-Based Online Adaptive Radiation Therapy, An Qin, J Xu, N O'Connell, Xuanfeng Ding, Shupeng Chen, D Thill
The Clinical Usability, Efficiency, And Accuracy Of Combining Deep-Learning-Based Synthetic Ct And Auto-Contouring For Daily Cbct-Based Online Adaptive Radiation Therapy, An Qin, J Xu, N O'Connell, Xuanfeng Ding, Shupeng Chen, D Thill
Conference Presentation Abstracts
Purpose: To evaluate the feasibility of deep-learning and CBCT-based online adaptive radiotherapy(ART) in thorax, Head&Neck, and pelvic regions. Methods: The study utilized ADMIRE(Advanced Medical Image Registration Engine), a research software designed to enable fast online ART through: (1)synthetic CT(sCT) generation from CBCT, (2)automatic segmentation of critical organs(OARs), and(3)deformable image registration(DIR) to transfer the target volume. ADMIRE trained a modified Cycle-Generative-Adversarial-Networks with Structural Similarity Index Map(SSIM) loss term to generate sCT, while the auto-segmentation model was based on a 3D-ResUnet with modification. Site-specific models were trained for three anatomic sites: thorax, pelvic, and head&neck, and for both networks. The study included …
Develop A Novel Beam Orientation Optimization Algorithm For Let (Linear Energy Transfer) Incorporated Impt (Intensity Modulated Proton Therapy) (Imptlet, R Dao, Y Qian, Xiaoqiang Li, H Quan, Xuanfeng Ding, G Liu
Develop A Novel Beam Orientation Optimization Algorithm For Let (Linear Energy Transfer) Incorporated Impt (Intensity Modulated Proton Therapy) (Imptlet, R Dao, Y Qian, Xiaoqiang Li, H Quan, Xuanfeng Ding, G Liu
Conference Presentation Abstracts
Purpose: To improve the dose and LET distribution in the IMPTLET, we introduce a new optimization algorithm to search for the optimal beam orientation and count through the arc trajectory (BOC-IMPTLET). Methods: We introduce kmeans clustering analysis in the BOC-IMPTLET algorithm by analyzing the distribution of LET in the target from the full arc trajectory. The optimal of cluster count was used as beam count, which was determined based on the SSE (Sum of Square Error) value and the angle of the corresponding centroid of each cluster was used as beam orientation, respectively. The BOC-IMPTLET algorithm was implemented in the …
Comparison Of Vmat Beam Complexity With Different Mlc Collimator Rotation And Their Impact On Psqa Pass Rates, David T. To, Michael G. Snyder, Jian Liang
Comparison Of Vmat Beam Complexity With Different Mlc Collimator Rotation And Their Impact On Psqa Pass Rates, David T. To, Michael G. Snyder, Jian Liang
Conference Presentation Abstracts
Purpose: I t has been previously shown that utilizing a collimator angle of ±45° has demonstrated a reduction in MU and VMAT beam complexity. Studies have demonstrated this for VMAT prostate plans with small sample size. In this study we evaluate multiple collimator angles with a larger sample size and different treatment sites. Methods: A total of 17273 VMAT beams were evaluated with beam collimator rotations of 0°, ±5°, ±10°, ±15°, ±30°, ±45°, and ±90°. QA Gamma pass rates for our institution use a 3%/2mm criteria 10% threshold with 95% limit pass rate utilizing Sun Nuclear ArcCheck (helical diode array). …
Predicting Tumor Voxel Dose-Response Using Deep Learning On Serial Fdg-Pet Feedback Images, Shupeng Chen, Di Yan, An Qin, Rohan Deraniyagala, Daniel Krauss, Peter Chen, Craig Stevens
Predicting Tumor Voxel Dose-Response Using Deep Learning On Serial Fdg-Pet Feedback Images, Shupeng Chen, Di Yan, An Qin, Rohan Deraniyagala, Daniel Krauss, Peter Chen, Craig Stevens
Conference Presentation Abstracts
Purpose: Tumor voxel dose-response matrix (DRM) can be assessed using a series of FDG-PET/CT feedback images acquired during radiotherapy. Predicting the tumor voxel DRM earlier is crucial for treatment adaptation. However, it is also challenging due to FDG fluctuation in tumor cells. This study investigated the feasibility of predicting DRM during early treatment weeks using deep learning (DL). Methods: FDG-PET images were acquired at the pretreatment (preTx), the 2nd and 4th weeks during chemo-radiotherapy (35×2Gy) from 50 head and neck patients. The reference value of tumor voxel DRM (DRMref), representing the average metabolic change ratio during the treatment, was determined …
Internal Lead Shielding For Clinical Electron Treatments, Patrick N. Mcdermott
Internal Lead Shielding For Clinical Electron Treatments, Patrick N. Mcdermott
Conference Presentation Abstracts
Purpose: Electron beams are often used to treat superficial lesions of the lip, cheek, nose and ear. Lead is frequently used to block distal structures. It is customary to place an internal bolus of low atomic number in between the tissue and the lead to reduce electron backscatter from the lead. Space for the lead and the internal bolus is quite limited. The current method, recommended by TG25, for estimating the thickness of the lead plus internal bolus is not self-consistent and leads to a larger than necessary thickness. Furthermore, this method uses an older expression for the electron backscatter …
A Novel Planning Framework For The Efficient Spot-Scanning Proton Arc Therapy Via The Particle Swarm Optimization (Sparc-Particle Swarm), Y Qian, R Dao, G Liu, Xiaoqiang Li, H Quan, Xuanfeng Ding
A Novel Planning Framework For The Efficient Spot-Scanning Proton Arc Therapy Via The Particle Swarm Optimization (Sparc-Particle Swarm), Y Qian, R Dao, G Liu, Xiaoqiang Li, H Quan, Xuanfeng Ding
Conference Presentation Abstracts
Purpose: The delivery efficiency is the bottleneck of spot-scanning proton arc therapy (SPArc) because of the numerous energy layers (EL) ascending switches. This study aims to develop a new algorithm to mitigate the need of EL ascending via water equivalent thickness (WET) sector selection followed by the particle swarm optimization (SPArc- particle swarm). Methods: SPArc- particle swarm divided the full arc trajectory into the optimal sectors based on the K-means clustering analysis of the relative mean WET. Within the sector, particle swarm optimization was used to minimize the total energy switch time, in which it optimized the energy selection integrated …
Linac-Based Srs Treatments Slow Down Unnecessarily Due To Parked Leaf Optimization, Brian Loughery, Cory S. Knill, Raminder P. Sandhu, Lifeng Lin, Jian Liang
Linac-Based Srs Treatments Slow Down Unnecessarily Due To Parked Leaf Optimization, Brian Loughery, Cory S. Knill, Raminder P. Sandhu, Lifeng Lin, Jian Liang
Conference Presentation Abstracts
Purpose: It was observed on a VersaHD that clinical SRS deliveries created in the Elements treatment planning system (TPS) slowed gantry rotation and dose rate to allow parked MLC leaves to move into position for use in an upcoming control point. Gantry rotation slowed suddenly, visibly backtracking to previous gantry angles. The purpose of this work is to study the effect of parked MLC positioning parameters in Elements on cranial SRS delivery speed and gantry motion on a VersaHD. Methods: To study the effect of parked MLC leaf positions on VersaHD deliverability, cranial SRS plans were generated with different TPS …
Application Of A Novel Optical Tool For Linac Calibrations, Cory S. Knill, Brian Loughery, Raminder P. Sandhu, Lifeng Lin, Mark Stefani
Application Of A Novel Optical Tool For Linac Calibrations, Cory S. Knill, Brian Loughery, Raminder P. Sandhu, Lifeng Lin, Mark Stefani
Conference Presentation Abstracts
Purpose: Maintaining a linac within tight stereotactic isocentricity tolerances requires minimizing errors in individual components of the linac. However, while isocentricity can be measured using a Winston-Lutz test, contributions from individual components can be difficult to discern. The disconnect between how individual components contribute to isocentricity can lead to lengthy troubleshooting exercises when isocentricity is outside tolerance. To provide more info rmation to physicists and increase the speed of isocentricity adjustments, a new tool that uses optical tracking to investigate and adjust individual linac components that contribute to isocentricity was tested on three clinical linacs. Methods: The optical tracking tool …
Individual Vmat Beam Complexity Indices Have Limited Predictive Value For Qa Pass-Rates, Jian Liang, Q Liu, David T. To, Michael G. Snyder
Individual Vmat Beam Complexity Indices Have Limited Predictive Value For Qa Pass-Rates, Jian Liang, Q Liu, David T. To, Michael G. Snyder
Conference Presentation Abstracts
Purpose: Previous studies with sample sizes <400 have indicated that VMAT beam complexity indices may have a relationship with measured QA pass-rates. The aim of this study is to evaluate such relationships on a large scale to further investigate their strength. Methods: Total of 17,273 VMAT QA results across 8 Elekta Agility machines were used in this study. All beams were flattened 6MV or 10MV. Sun Nuclear ArcCheck was used for QA measurements with γ-analysis parameters of 10% threshold, 3% dose difference, 2mm distance to agreement, and 95% passing threshold. A total 214 Beams (1.23%) failed QA. QA distributions in Pinnacle were calculated with 2 degree gantry intervals and a dose grid of 2mm. Four complexity indices (MCSv, MU weighted Segment Area, Segment Area/Perimeter, and Average Leaf Gap) were computed. Spearman’s correlations were evaluated for each, and cut-off values for the indices were sought to indicate values above which no QA failures would be expected. Results: Evaluation of the 4 complexity metrics showed weak correlation with QA pass rates (< ±0.42) with high significance (p < 0.001). When metrics were evaluated independently, cut-off values from correlation plots separated only 0.67%, 0.72%, 2.2%, 6.3% guaranteed passing beams from the total sample, respectively. When evaluating whether anymetric for a given beam exceeded its cut-off, the fraction of guaranteed passing beams rose to only 6.6%. However, when cut-off values for one metric were allowed to be functionally dependent upon another, the fraction of guaranteed passing beams increased. For MU weighted Segment Area andAverage Leaf Gap, a dependent approach separated 19.1% guaranteed passing beams from the sample. Conclusion: Individual complexity metrics have weak predictive utility in assessing plan performance. However, using multiple complexity cut-off functions with dependence upon more than one metric increased the fraction of predicted passing beams by around 300%.
Does Proton Arc Therapy Has Potential Clinical Benefits For Hepatocellular Carcinoma?, Peilin Liu, R Dalfsen, M Soukup, Shupeng Chen, Lewei Zhao, Z Wang, X S. Gao, Thomas Quinn, Craig Stevens, Rohan Deraniyagala, Xiaoqiang Li, Xuanfeng Ding
Does Proton Arc Therapy Has Potential Clinical Benefits For Hepatocellular Carcinoma?, Peilin Liu, R Dalfsen, M Soukup, Shupeng Chen, Lewei Zhao, Z Wang, X S. Gao, Thomas Quinn, Craig Stevens, Rohan Deraniyagala, Xiaoqiang Li, Xuanfeng Ding
Conference Presentation Abstracts
Purpose: To investigate the potential clinical benefits and dose-averaged Linear Energy Transfer (LETd) sparing, utilizing proton arc plan for Hepatocellular carcinoma (HCC) patients in comparison with Intensity Modulated Proton Therapy (IMPT). Methods: Ten HCC patients have been retrospectively selected. Two planning groups were created: Proton Arc plans using Monaco ver. 6 and the clinical IMPT plan. Both planning groups used the same robustness parameters. The prescription dose is 67.5 Gy (RBE) in 15 fractions/ 66 GyE in 10 fractions of the Clinical Target Volume (CTV) following clinical IMPT plan. Robustness evaluations were performed to ensure target dose coverage. Normal Tissue …
An Analytic Model Of The External Beam Dose Rate Effect On Immune Cells In Blood Dosimetry, Lewei Zhao, Peilin Liu, G Liu, Xuanfeng Ding
An Analytic Model Of The External Beam Dose Rate Effect On Immune Cells In Blood Dosimetry, Lewei Zhao, Peilin Liu, G Liu, Xuanfeng Ding
Conference Presentation Abstracts
Purpose: Radiation therapy is a double-edged sword with regard to its immunomodulatory effect. It is critical to find how it is affected by dose rate. Thus, we developed an analytic model for calculating the number of immune cells receiving radiation. Methods: Suppose the blood is received radiation by constant dose rate. The blood is one-way flow without circulation in the radiation delivery at a constant velocity. Two kinds of lung treatment regimens were considered standard delivery 2Gy per fx total 30fx and hypo-fractionation SBRT 12 Gy per fx total 5 fx. Two different dose rates were simulated for standard treatment: …
Tumor Locations Impact On Cardiac Toxicity In Women That Received Partial Breast Irradiation, Sara Diltz, Muayad Almahariq, Joshua Dilworth
Tumor Locations Impact On Cardiac Toxicity In Women That Received Partial Breast Irradiation, Sara Diltz, Muayad Almahariq, Joshua Dilworth
Posters
Accelerated partial breast irradiation (APBI) is an appropriate modality for select women with low-risk breast cancer. While APBI delivers radiation dose to a smaller volume of breast tissue compared to whole breast irradiation, dose to the heart and coronary vessels may be relatively high, depending on the proximity of the treatment device to these structures. The primary goal of this study is to determine if the risk of adverse cardiac events depends on tumor location in women receiving APBI.
High Dose Rate Brachytherapy Monotherapy Versus External Beam Radiotherapy With Hdr Brachytherapy Boost For Unfavorable Intermediate Prostate Cancer Patients, Doyle Lang, Benjamin Willen, Daniel J. Krauss, Sirisha R. Nandalur
High Dose Rate Brachytherapy Monotherapy Versus External Beam Radiotherapy With Hdr Brachytherapy Boost For Unfavorable Intermediate Prostate Cancer Patients, Doyle Lang, Benjamin Willen, Daniel J. Krauss, Sirisha R. Nandalur
Posters
Prostate cancer is the most common male malignancy by incidence in the world. Treatment differs by the patient’s risk stratification. For the treatment of unfavorable intermediate-risk prostate cancer, external beam radiotherapy with high-dose-rate brachytherapy boost was the accepted treatment but high-dose-rate brachytherapy as monotherapy has been proposed as a potentially viable treatment option. External beam radiotherapy treatment involves shooting high-energy photons or particle radiation through normal healthy tissue to hit the tumor directly. High-dose-rate brachytherapy involves inserting radioactive seeds into the tumor. Studies are needed to compare toxicity profiles and relative outcomes between the two treatment options.
Impact Of Structured Reporting Template On The Quality Of Hrct Radiology Reports For Interstitial Lung Disease, Han G. Ngo, Girish B. Nair, Sayf Al-Katib
Impact Of Structured Reporting Template On The Quality Of Hrct Radiology Reports For Interstitial Lung Disease, Han G. Ngo, Girish B. Nair, Sayf Al-Katib
Posters
This QI study compared the completeness of HRCT radiology reports before and after the implementation of a disease-specific structured reporting template for suspected cases of interstitial lung disease (ILD).
Dose To The Left Anterior Descending Artery Correlates With Cardiac Events After Irradiation For Breast Cancer, Brittany Silverman, Andrew Zureick, Vincent Grzywacz, Muayad Almahariq, Aleksander Vayntraub, Joshua Dilworth
Dose To The Left Anterior Descending Artery Correlates With Cardiac Events After Irradiation For Breast Cancer, Brittany Silverman, Andrew Zureick, Vincent Grzywacz, Muayad Almahariq, Aleksander Vayntraub, Joshua Dilworth
Posters
Although global heart dose has been associated with late cardiac toxic effects in patients who received radiation therapy for breast cancer, data detailing the clinical significance of cardiac substructure dosimetry are limited. We investigated whether dose to the left anterior descending artery (LAD) correlates with adverse cardiac events.
Influence Of Pretreatment Magnetic Resonance Imaging On Local Therapy Decisions For Intermediate-Risk Prostate Cancer Patients, Christian Skowronski, Andrew Shanholtzer, Brent Yelton, Muayad Almahariq, Daniel Krauss
Influence Of Pretreatment Magnetic Resonance Imaging On Local Therapy Decisions For Intermediate-Risk Prostate Cancer Patients, Christian Skowronski, Andrew Shanholtzer, Brent Yelton, Muayad Almahariq, Daniel Krauss
Posters
Prostate cancer has the third highest incidence rate and is the second leading cause of cancer death for men in the United States. Magnetic resonance imaging (MRI) provides superior soft tissue delineation serving as a valuable tool for both diagnosis and treatment planning. With minimal data regarding utility on diagnosis and treatment planning for intermediate-risk prostate cancer, the National Comprehensive Cancer Network’s guidelines indicate MRI as optional in intermediate-risk prostate cancer evaluation. This project aims to elucidate whether MRI affects radiation treatment decisions for intermediate-risk prostate cancer.
Outcomes Of Locally Advanced Lung Cancer Patients Treated With 60 Gy Vs. 70 Gy, Batoul Nasser, Muyad Almahariq, Inga Grills
Outcomes Of Locally Advanced Lung Cancer Patients Treated With 60 Gy Vs. 70 Gy, Batoul Nasser, Muyad Almahariq, Inga Grills
Posters
The standard form of treatment for locally advanced lung cancer is to prescribe the conventional dose of 60 Gy radiation therapy (RT) concurrently with chemotherapy. However, five-year overall survival is still less than 20%. These outcomes remain poor due to both distant and local regional recurrence. The literature suggests that local regional control and overall survival is strongly associated with doses of radiotherapy that are higher than 60 Gy. However, when escalating radiation dose was prescribed exceeding 70 Gy, the overall survival rates plateaued. The primary goal of this study is to determine if there is a marked difference in …
Expansion Of The Detrusor Muscular Ring Surrounding The Bladder Neck On Mri: Moving Beyond The Prostate As An Etiology Of Lower Urinary Tract Symptoms Due To Benign Prostatic Hyperplasia, Kiran Nandalur, David Walker, Hong Ye, Sayf A. Al-Katib, Brian Seifman, David Gangwish, Abhay Dhaliwal, Connor Ervin, Kayla Dobies, Channing Sesoko, Sirisha Nandalur, Bernadette Zwaans, Jennifer Nguyen, Jason Hafron
Expansion Of The Detrusor Muscular Ring Surrounding The Bladder Neck On Mri: Moving Beyond The Prostate As An Etiology Of Lower Urinary Tract Symptoms Due To Benign Prostatic Hyperplasia, Kiran Nandalur, David Walker, Hong Ye, Sayf A. Al-Katib, Brian Seifman, David Gangwish, Abhay Dhaliwal, Connor Ervin, Kayla Dobies, Channing Sesoko, Sirisha Nandalur, Bernadette Zwaans, Jennifer Nguyen, Jason Hafron
Conference Presentation Abstracts
Purpose: The etiology of lower urinary tract symptoms secondary to benign prostatic hyperplasia (LUTS/BPH) remains uncertain. The purpose of our study was to quantitatively analyze pelvic anatomic characteristics on magnetic resonance imaging (MRI) to assess for independent factors for symptoms.
*Methods and Materials: This retrospective single-institution study evaluated treatment-naïve men who underwent prostate MRI within 3 months of International Prostate Symptom Score (IPSS) from June 2021 to February 2022. Factors measured on MRI included: detrusor muscular ring surrounding the bladder neck measured as area and alternatively diameter, central gland (CG) mean apparent diffusion coefficient (ADC), levator hiatus (LH) volume, intrapelvic …