Open Access. Powered by Scholars. Published by Universities.®

Other Medical Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Theses/Dissertations

Medical Specialties

Institution
Keyword
Publication Year
Publication

Articles 31 - 36 of 36

Full-Text Articles in Other Medical Sciences

An Investigation Of Nurbs-Based Deformable Image Registration, Travis J. Jacobson Jan 2014

An Investigation Of Nurbs-Based Deformable Image Registration, Travis J. Jacobson

Theses and Dissertations

Deformable image registration (DIR) is an essential tool in medical image processing. It provides a means to combine image datasets, allowing for intra-subject, inter-subject, multi-modality, and multi-instance analysis, as well as motion detection and compensation. One of the most popular DIR algorithms models the displacement vector field (DVF) as B-splines, a sum of piecewise polynomials with coefficients that enable local shape control. B-splines have many advantageous properties in the context of DIR, but they often struggle to adequately model steep local gradients and discontinuities. This dissertation addresses that limitation by proposing the replacement of conventional B-splines with a generalized formulation …


Effect Of Blood Collection Practices On Emergency Department Blood Specimen Rejection Rates, Barbara K. Vernoski Jan 2013

Effect Of Blood Collection Practices On Emergency Department Blood Specimen Rejection Rates, Barbara K. Vernoski

UNF Graduate Theses and Dissertations

The practice of obtaining blood as part of the placement of a new peripheral venous access device (p-VAD) is a frequent practice in the emergency department (ED). Of the concerns related to this practice is the possibility of laboratory specimen rejection due to p-VAD catheter size, use of the wrong collection device, and the absence of a standardized collection process. The objective of this study, therefore, was to examine the effect of the use of evidence-based venipuncture and p-VAD blood collection protocols on the rejection rate of blood specimens drawn by staff in the adult areas of an urban academic …


In-Vivo Ct Dosimetry During Virtual Colonoscopy, Jonathon W. Mueller Aug 2011

In-Vivo Ct Dosimetry During Virtual Colonoscopy, Jonathon W. Mueller

Dissertations & Theses (Open Access)

Virtual colonoscopy (VC) is a minimally invasive means for identifying colorectal polyps and colorectal lesions by insufflating a patient’s bowel, applying contrast agent via rectal catheter, and performing multi-detector computed tomography (MDCT) scans. The technique is recommended for colonic health screening by the American Cancer Society but not funded by the Centers for Medicare and Medicaid Services (CMS) partially because of potential risks from radiation exposure. To date, no in‐vivo organ dose measurements have been performed for MDCT scans; thus, the accuracy of any current dose estimates is currently unknown.

In this study, two TLDs were affixed to the inner …


Clinical Impact Of Couch Top And Rails On Imrt And Arc Therapy, Kiley B. Pulliam Aug 2011

Clinical Impact Of Couch Top And Rails On Imrt And Arc Therapy, Kiley B. Pulliam

Dissertations & Theses (Open Access)

Purpose: To evaluate the clinical impact of the Varian Exact Couch on dose and volume coverage to targets and critical structures and tumor control probability (TCP) for 6-MV IMRT and Arc Therapy.

Methods: Five clinical prostate patients were planned with both, 6-MV 8-field IMRT and 6-MV 2-field RapidArc using the Eclipse treatment planning system (TPS). These plans neglected treatment couch attenuation, as is standard clinical practice. Dose distributions were then recalculated in Eclipse with the inclusion of the Varian Exact Couch (imaging couch top) and the rails in varying configurations. The changes in dose and coverage were evaluated using the …


An Implantable Mosfet Dosimeter Modified To Act As A Fiducial Marker, Joseph S. Dick Aug 2010

An Implantable Mosfet Dosimeter Modified To Act As A Fiducial Marker, Joseph S. Dick

Dissertations & Theses (Open Access)

In external beam radiation therapy, it is imperative that the prescribed dose is administered to the correct location and in the correct amount. Though several ex vivo methods of quality assurance are currently employed to achieve this goal, verifying that the correct dose is received within the patient in situ is impossible without the capability of measuring dose inside the patient. Recently, a method of measuring dose delivered within the patient has been developed, an implantable MOSFET dosimeter. This dosimeter is implanted within the patient and records the dose received. Since the dosimeter is implanted in the patient, it could …


Renal Basolateral Transport Of Glucuronides And Other Organic Anions In Rat In Vitro Models, Sarah L. Miles Jan 2004

Renal Basolateral Transport Of Glucuronides And Other Organic Anions In Rat In Vitro Models, Sarah L. Miles

Theses, Dissertations and Capstones

Glucuronidation is a common Phase II biotransformation reaction that increases the hydrophilicity, and thus elimination, of toxins, xenobiotics, and endogenous compounds. Previous studies suggest that the kidney can secrete glucuronide conjugates, but the renal transport mechanisms for glucuronide secretion have not been determined. Based on the chemical nature of glucuronide metabolites, it is hypothesized that organic anion transporter (OAT) proteins along the basolateral membrane of the renal proximal tubule promote renal accumulation of glucuronide conjugates. The purpose of this study was to develop a rat renal proximal tubule model which demonstrates OAT activity and by which the contribution of OAT …