Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- Chulalongkorn University (74)
- The British University in Egypt (65)
- American Dental Association (55)
- Loma Linda University (36)
- Saint Joseph University of Beirut (26)
-
- Association of Arab Universities (25)
- Universitas Indonesia (23)
- LSU Health New Orleans (14)
- Virginia Commonwealth University (12)
- Marquette University (9)
- University of Tennessee Health Science Center (9)
- West Virginia University (8)
- Roseman University of Health Sciences (7)
- Loyola University Chicago (6)
- A.T. Still University (5)
- University of the Pacific (5)
- City University of New York (CUNY) (4)
- Beirut Arab University (3)
- University of Connecticut (3)
- University of Kentucky (3)
- JSS Academy of Higher Education and Research (2)
- Nova Southeastern University (2)
- University of AlKafeel (2)
- University of Louisville (2)
- University of Malaya (2)
- University of Nevada, Las Vegas (2)
- University of New England (2)
- Dartmouth College (1)
- Journal of Dental Sciences (1)
- Manipal Academy of Higher Education (1)
- Keyword
-
- Oral health (36)
- Brochure (34)
- Dental health education (34)
- Pamphlet (34)
- Booklet (28)
-
- Leaflet (28)
- Prosthodontics (27)
- Tooth loss (23)
- Dentures (19)
- Overdenture (11)
- Implants (10)
- Denture care (9)
- Implant (9)
- Zirconia (9)
- Dental exams (8)
- Dental visits (8)
- Fluoride (7)
- Oral cancer (7)
- Deciduous teeth (6)
- Dental implant (6)
- Dental implants (6)
- Malocclusion (6)
- Permanent teeth (6)
- Plaque (6)
- Tooth shifting (6)
- 3D printing (5)
- Cone beam computed tomography (5)
- Dental cartoon (5)
- Dental diseases (5)
- Dental habits (5)
- Publication Year
- Publication
-
- Chulalongkorn University Theses and Dissertations (Chula ETD) (74)
- Dentistry (65)
- Loma Linda University Electronic Theses, Dissertations & Projects (36)
- Patient Dental Health Education Materials 1929-1981 (34)
- International Arab Journal of Dentistry (26)
-
- Future Dental Journal (25)
- Journal of Dentistry Indonesia (21)
- School of Dentistry Faculty Publications (14)
- The New York State Dental Journal (11)
- Theses and Dissertations (10)
- Master's Theses (9)
- The Journal of the Michigan Dental Association (9)
- Theses and Dissertations (ETD) (9)
- Graduate Theses, Dissertations, and Problem Reports (ETD) (8)
- Annual Research Symposium (7)
- Master's Theses (2009 -) (6)
- MOSDOH Faculty Publications (5)
- Publications and Research (4)
- BAU Journal - Creative Sustainable Development (2)
- Bachelors’ Theses (2)
- Dental Medicine Faculty Publications (2)
- Dental Medicine Faculty Research (2)
- Electronic Theses and Dissertations (2)
- Excellence Day (2)
- International Journal of Health and Allied Sciences (2)
- Internet Journal of Allied Health Sciences and Practice (2)
- Maaen Journal for Medical Sciences (2)
- Oral Health (2)
- Oral Health Practice Faculty Publications (2)
- AUCTUS: The Journal of Undergraduate Research and Creative Scholarship (1)
- Publication Type
Articles 91 - 120 of 413
Full-Text Articles in Dentistry
The Study On Surface Roughness And Corrosion Resistance Of Electropolished Laser Powder Bed Fusion Ti-6al-4v Eli Alloy, Venus Chatpaiboonwat
The Study On Surface Roughness And Corrosion Resistance Of Electropolished Laser Powder Bed Fusion Ti-6al-4v Eli Alloy, Venus Chatpaiboonwat
Chulalongkorn University Theses and Dissertations (Chula ETD)
The Ti6Al4V ELI alloy produced via Laser Powder Bed Fusion (L-PBF) has drawn interest for usage in dental applications. However, surface finishing is an important property that can be managed by various methods. The purpose of this study was to investigate the effects of electropolishing (EP) on the surface roughness and corrosion resistance of L-PBF Ti6Al4V ELI alloy. The present study explored the influence of current density, voltage, and distance on the surface quality and corrosion behavior. The results showed that EP significantly reduced the surface roughness and enhanced corrosion resistance of printed Ti6Al4V ELI alloy with the best result …
Implant Overdenture Abutment Loosening Under Hyperbaric Conditions, Zana Jamal Al-Saloum
Implant Overdenture Abutment Loosening Under Hyperbaric Conditions, Zana Jamal Al-Saloum
Graduate Theses, Dissertations, and Problem Reports (ETD)
Objectives: To investigate the effect of various hyperbaric air pressures on the loosening of LOCATOR® (ZEST Anchors, LLC, Escondido, CA USA) overdenture abutments.
The pressure conditions tested are meant to simulate scuba diving conditions in edentulous patients that are restored with implant-retained tissue-supported overdentures. Another sub-goal of this study is to determine whether or not there is a difference in LOCATOR® loosening when the sample is exposed to six cycles/dives as opposed to one cycle/dive.
Methods: 36 ZimVie Tapered Screw Vent Implants with a 3.5mm diameter implant platform, and a 2.5mm diameter (and 1.5mm deep) internal hexagon were …
Adaptation Of Conventional Versus Digitally Fabricated Auricular Prosthesis: A Randomized Clinical Trial, Sara Fikry, Fatma Mohei El Mogei Dr, Mohamed El Khashab Prof, Amal Rekabi Prof
Adaptation Of Conventional Versus Digitally Fabricated Auricular Prosthesis: A Randomized Clinical Trial, Sara Fikry, Fatma Mohei El Mogei Dr, Mohamed El Khashab Prof, Amal Rekabi Prof
Dentistry
Aim: This study aimed to compare digitally fabricated auricular prostheses to conventional prostheses, regarding adaptation to defect site in patients with auricular defects.
Subjects and methods: Fifteen patients were recruited for auricular prosthetic reconstruction. Endosseous implants were placed, then patients were assigned into two groups. In control group, ear models were processed on stone cast obtained from conventional impression. In intervention group, computed tomography and optical scanning were combined to obtain a virtual model with digital analogues over which ear models were designed and printed. Ear models of both groups were seated, and adaptation was measured on the patient using …
Comparison Of The Failure Between Conventional Pmma And Milled Pmma Full Arch Maxillary Interim Prosthesis Fixed On 4 Implants: An In Vitro Study, Tatiana Bou Sakr, Hani Tohme, Natalia Bou Sakr, Victor Ghoubril, Carole Abi Ghosn Yared
Comparison Of The Failure Between Conventional Pmma And Milled Pmma Full Arch Maxillary Interim Prosthesis Fixed On 4 Implants: An In Vitro Study, Tatiana Bou Sakr, Hani Tohme, Natalia Bou Sakr, Victor Ghoubril, Carole Abi Ghosn Yared
International Arab Journal of Dentistry
Objectives: The principal objective of this study was to compare the failure load between the conventional heat polymerized PMMA and the CAD/CAM milled PMMA interim full arch implant prostheses. The secondary aim was to evaluate the success of the distal extension of the temporary PMMA prosthesis.
Methods: A metallic edentulous upper arch model with 4 Straumann screw-retained abutment digital analogs was used to create 15 specimens for each of the 2 groups: Conventional and milled. Failure load was measured on 5 different regions on the left and right side of each specimen with the YLE universal testing machine: …
Testing The Strength Of Thin Feather-Edge Monolithic Multilayered Zirconia Crowns: A Pilot Study With A Novel Acoustic Test, Estelle Saab, Camille Haddad, Maher Abboud, Maha Daou, Amine Zoghbi
Testing The Strength Of Thin Feather-Edge Monolithic Multilayered Zirconia Crowns: A Pilot Study With A Novel Acoustic Test, Estelle Saab, Camille Haddad, Maher Abboud, Maha Daou, Amine Zoghbi
International Arab Journal of Dentistry
Introduction: Limited research has explored the mechanical characteristics of recently introduced multilayered monolithic zirconia (MZC) crowns with feather-edge margins design. Moreover, most of the conventional techniques for evaluating the mechanical behavior of brittle dental ceramics rely on destructive tests, making it impossible to precisely evaluate real strength values due to premature crack initiation detection failure.
Objectives: The main objective of the study was to assess the load capacity of translucent multilayered monolithic zirconia crowns with feather-edge margin thicknesses of 0.4 mm and 0.5 mm. Additionally, the research introduced a novel non-destructive acoustic emission testing (AET) technique in the …
Investigation Of Fracture Resistance With Different Diameters Of Polyetherketoneketone Post And Core Materials: A Pilot Study, Maya Kabbara, Ryan Harouny, Habib Rahme
Investigation Of Fracture Resistance With Different Diameters Of Polyetherketoneketone Post And Core Materials: A Pilot Study, Maya Kabbara, Ryan Harouny, Habib Rahme
International Arab Journal of Dentistry
Objectives: The primary objective of this study is to investigate the resistance to fracture of Polyetherketoneketones PEKK, used as post and core by fabrication in different diameters in the canal, and comparing the test results for each group.
Methods: Thirty extracted mandibular premolars were selected, endodontically treated and prepared to receive the post and cores milled from polyetherketoneketone disk. The specimens were randomly divided into five groups (n = 6) respectively: group 1 received pekk post with diameter = 0.70 mm, group 2 received pekk post with diameter = 0.90 mm, group 3 received pekk post with diameter …
Endocrown, From Preparation To Bonding: Case Report, Amira Yousfi, Rihab Dakhli, Jilani Saafi, Belhassen Harzallah
Endocrown, From Preparation To Bonding: Case Report, Amira Yousfi, Rihab Dakhli, Jilani Saafi, Belhassen Harzallah
International Arab Journal of Dentistry
The restoration of endodontically treated teeth is a real challenge, particularly teeth with extensively damaged coronal tissues. The use of post-retained restorations has been discussed because of the potential tooth weakening due to the additional removal of sound dental structures. In fact, long-term prognosis of a devitalized tooth is closely related to the coronal restoration’s quality and the remaining dental structure. With the development of adhesive dentistry and minimally invasive preparation, new approaches have emerged. Among them, the endocrown which is monolithic ceramic bonded restoration, anchored to the internal portion of pulp chamber and cavity margins that have been used …
Clinical Outcomes Of Primary Anterior Esthetic Crowns In Pediatric Dentistry, Jenan Alahmad
Clinical Outcomes Of Primary Anterior Esthetic Crowns In Pediatric Dentistry, Jenan Alahmad
Theses and Dissertations
Clinical Outcomes of Primary Anterior Esthetic Crowns in Pediatric Dentistry - A Prospective Cohort Study
By: Jenan Alahmad, BDS
A thesis submitted in partial fulfillment of the requirements for the degree of Master of Science in Dentistry at Virginia Commonwealth University.
Virginia Commonwealth University, 2024
Thesis Advisor: Parthasarathy Madurantakam, DDS, MDS, PhD
Department of Pediatric Dentistry
BODY
Purpose: This prospective cohort study aimed to compare the effectiveness of restoring maxillary anterior teeth in children (aged 3-6 years) with three different materials: Zirconia Crowns (ZC), Resin Composite Crowns (RC), and Pre-veneered Stainless-Steel Crowns (PVSSC). The study aims to assess the Oral …
การศึกษาการสึกระหว่างโคบอลต์โครเมียมและวัสดุเซรามิกที่ใช้ในงานทันตกรรมดิจิตอล, มรกต ไทยรัตน์
การศึกษาการสึกระหว่างโคบอลต์โครเมียมและวัสดุเซรามิกที่ใช้ในงานทันตกรรมดิจิตอล, มรกต ไทยรัตน์
Chulalongkorn University Theses and Dissertations (Chula ETD)
วัตถุประสงค์: ทำการศึกษาสภาวะจำลองเพื่อวัดการสูญเสียปริมาตรจากการสึกหลังจากจำลองการขัดถู 250,000 รอบของโลหะผสมโคบอลต์โครเมียม (CoCr) กับวัสดุที่ใช้ทำการบูรณะฟันหลักห้าชนิด วัสดุและวิธีการ: เตรียมตัวอย่างทดสอบตัดเป็นสี่เหลี่ยมจำนวนชนิดละ 8 ชิ้น (5 x 5 x 2 มิลลิเมตร) จากโลหะผสมที่ไม่มีทองผสม (NP), ลิเธียมไดซิลิเกต (EM) เธียมไดซิลิเกตเสริมความแข็งแรง (TR) เซรามิคที่มีเรซินเป็นฐาน (CM) และเซอร์โคเนีย (ZR) ตัวอย่าง EM TR และ ZR ได้รับการเผาตามคำแนะนำของผู้ผลิต แท่งโลหะผสมโคบอลต์โครเมียมสร้างขึ้นโดยการหล่อโลหะแบบไล่ขี้ผึ้ง จำลองการสึกแบบสององค์ประกอบด้วยเครื่องจำลองการสึกจากการขัดถู จำนวน 250,000 รอบ วัดการสูญเสียปริมาตรของชิ้นงานทดสอบโดยใช้เครื่องวัดความหยาบพื้นผิว การสูญเสียปริมาตรของแท่งโลหะผสมคำนวณโดยการความยาวที่ลดลงและรัศมีของพื้นที่ที่เกิดบริเวณที่สึก วิเคราะห์ข้อมูลทางสถิติโดยใช้ MANOVA (pNP>ZR) การสูญเสียปริมาตรของแท่งโลหะหลังการสึกในกลุ่ม CM น้อยกว่าในกลุ่ม EM และ NP ในขณะที่กลุ่มอื่น ๆ ไม่มีความแตกต่างกันอย่างมีนัยสำคัญ
Integration Of Massive Open Online Course (Mooc) In Conventional Teaching And Learning For Fixed Prosthodontics - A Case Study, Nor Faharina Abdul Hamid, Rohana Ahmad, Tong Wah Lim, Nur Hafizah Kamar Affendi, Tengku Fazrina Tengku Mohd Ariff, Melati Mahmud, Siti Mariam Ab Ghani
Integration Of Massive Open Online Course (Mooc) In Conventional Teaching And Learning For Fixed Prosthodontics - A Case Study, Nor Faharina Abdul Hamid, Rohana Ahmad, Tong Wah Lim, Nur Hafizah Kamar Affendi, Tengku Fazrina Tengku Mohd Ariff, Melati Mahmud, Siti Mariam Ab Ghani
Journal of Dentistry Indonesia
The potential for Massive Open Online Courses (MOOCs) in clinical dentistry remains vague and inadequately explored. Objectives: The study aims to obtain insight into the development of MOOCs in Fixed Partial Dental Prostheses (FPDPs) and to assess students’ learning preferences, module quality, and interface usability. Methods: The MOOCs was created by seven academicians with prosthodontic backgrounds. After completing the MOOCs and three complementary online discussion sessions, the students (n = 89) were invited to participate in an online survey. SPSS version 23 was used to calculate the frequency, percentage, mean, and standard deviation of categorical data (SD). Results …
Shore A Hardness And Fourier Transform Infrared Spectrophotometer Analysis Of Thymol-Modified Maxillofacial Silicone Material, Manar Hussein Ramadhan, Faiza M. Abdul-Ameer
Shore A Hardness And Fourier Transform Infrared Spectrophotometer Analysis Of Thymol-Modified Maxillofacial Silicone Material, Manar Hussein Ramadhan, Faiza M. Abdul-Ameer
Maaen Journal for Medical Sciences
The longevity of any prosthesis depends on the materials from which it was fabricated, which is why defects in the material properties may reduce the service life of the prosthesis and necessitate its replacement. This study aims to test the influence of incorporating different weight percentages of thymol micro-powder into the maxillofacial silicone matrix on Shore A hardness of the silicone. Room-temperature vulcanised VST-50 maxillofacial silicone was used to prepare the study specimens. Thymol micro-powder was incorporated into the silicone matrix in two percentages (0.75 wt.% and 1 wt.%). 30 specimens were prepared and then subdivided equally into three groups, …
The Back Page Commentary: Let’S Talk About The Real World, Danielle Gehlert Dds
The Back Page Commentary: Let’S Talk About The Real World, Danielle Gehlert Dds
The Journal of the Michigan Dental Association
Dr. Danielle Gehlert, a private practitioner, writes that in the realm of continuing education for dental professionals, there's a need for a shift in focus from idealized, "sexy" cases to real-world patient scenarios. This commentary calls for seminars and programs emphasizing long-term restorative planning, including successes and failures. The practical considerations of patient financial limitations and willingness to engage in dental care must be integral to treatment plans. Real-world cases should reflect the diverse situations dental practitioners encounter and the ethical responsibility to provide affordable and effective treatment options.
Use Of A 3d Intraoral Scanner For Prosthetic Rehabilitation Of Cocaine-Induced Oronasal Fistula, Anita Agarwal Bds, Dmd, Mph, Timothy Levine Dmd, Victor Badner Dmd, Mph
Use Of A 3d Intraoral Scanner For Prosthetic Rehabilitation Of Cocaine-Induced Oronasal Fistula, Anita Agarwal Bds, Dmd, Mph, Timothy Levine Dmd, Victor Badner Dmd, Mph
The New York State Dental Journal
A novel method using a 3D intraoral scanner (IOS) is used to overcome difficulties in obtaining conventional impressions to fabricate an obturator for a posteriorly located oronasal fistula secondary to chronic nasal cocaine use.
N Y State Dent J November 2023
N Y State Dent J November 2023
The New York State Dental Journal
In the November 2023 issue, the reader will find the following feature articles:
- Verruciform Xanthoma
- Use of a 3D Intraoral Scanner for Prosthetic Rehabilitation of Cocaine-Induced Oronasal Fistula
- Adenoid Ameloblastoma with Dentinoid
This issue includes regular columns with regional news impacting the New York membership including: editorial and perspectives columns, legal, association activities, component news, continuing education opportunities, and classifieds.
Hollow Bulb Definitive Obturation Of A Post-Covid Mucormycosis Maxillectomy Defect – A Case Report., Ravi M B, Prakash P, Sai Pranathi Putta, Anupama Aradya, Rashmi S, Dhakshaini M R
Hollow Bulb Definitive Obturation Of A Post-Covid Mucormycosis Maxillectomy Defect – A Case Report., Ravi M B, Prakash P, Sai Pranathi Putta, Anupama Aradya, Rashmi S, Dhakshaini M R
International Journal of Health and Allied Sciences
The novel Coronavirus, also known as SARS-CoV-2 (Severe Acute Respiratory Syndrome Coronavirus 2), causes COVID-19.In the wake of COVID-19, incidences of mucormycosis were rising alarmingly, especially rhino-orbital-cerebral mucormycosis.Most cases required surgical intervention followed by the fabrication of obturators.A hollow obturator is the most practical, convenient, and cost-effective solution for prosthodontic rehabilitation. A patient with pain overthe maxillary region (left) reported to the department of Prosthodontics and Crown & Bridge. His past medical history revealed that he tested and recovered from SARS-CoV-2. Clinical, radiographic, and smear tests confirmed rhino-cerebral mucormycosis with post covid pneumonia. Surgical left partial maxillectomy performed 4 months …
Fabrication And Characterization Of Nylon 6 Fiber Via Wet Spinning Method For Application As A Reinforcing Material For A Direct Dental Bridge, Dissa Kirana Wijaya, Nina Djustiana, Yanwar Faza, Arief Cahyanto, Andri Hardiansyah
Fabrication And Characterization Of Nylon 6 Fiber Via Wet Spinning Method For Application As A Reinforcing Material For A Direct Dental Bridge, Dissa Kirana Wijaya, Nina Djustiana, Yanwar Faza, Arief Cahyanto, Andri Hardiansyah
Makara Journal of Science
Nylon is a biocompatible thermoplastic polymer that is well known for its excellent fracture resistance, making it suitable for fabricating fiber-reinforced composite (FRC)-based dental bridges. FRC is widely used in dentistry. This study aimed to investigate the structural and morphological characteristics of the nylon 6 fiber prepared using five different weights of nylon 6 dissolved in formic acid. The nylon 6 fiber was successfully fabricated via a simple wet spinning method using water as a coagulant. The fiber was then characterized using Fourier transform infrared (FTIR) spectroscopy, optical microscopy, and scanning electron microscopy. FTIR spectroscopy confirmed the presence of nylon …
Bond Strength Of Reline Materials To 3d-Printed Provisional Crown Resins, Jorge Palavicini, Sherrod L. Quin, Wael Zakkour, Karim Zakkour, Safa Manafi Varkiani, Xiaoming Xu, Nathaniel C. Lawson, Amir Hossein Nejat
Bond Strength Of Reline Materials To 3d-Printed Provisional Crown Resins, Jorge Palavicini, Sherrod L. Quin, Wael Zakkour, Karim Zakkour, Safa Manafi Varkiani, Xiaoming Xu, Nathaniel C. Lawson, Amir Hossein Nejat
School of Dentistry Faculty Publications
(1) Purpose: The aim of the present study was to compare the bond strength between two 3D-printed resins designed for long-term provisional crowns and three different reline materials. (2) Materials and Methods: Rectangular specimens were prepared from two 3D-printed resins (Envision Tech and NextDent C&B) and a conventional self-cure PMMA. Transparent tubes filled with three different reline materials including composite resin, Bis-acryl, and PMMA were bonded to the 3D-printed specimens (n = 11 per group, total of 6 study groups). Tubes filled with PMMA were bonded to the prepared PMMA specimens which served as the control group (n = 11, …
Comparison Of Two Different Intraoral Scanners For Determination Of Caries Related Volume Loss In Caries Removal, Merve Şeker, Elif Alkan, Dilek Tağtekin, Bora Korkut, Funda Yanıkoğlu
Comparison Of Two Different Intraoral Scanners For Determination Of Caries Related Volume Loss In Caries Removal, Merve Şeker, Elif Alkan, Dilek Tağtekin, Bora Korkut, Funda Yanıkoğlu
Journal of Dentistry Indonesia
Objective: The study aimed to compare cavity volume data obtained with two different intraoral scanners. Methods: One hundred extracted molar teeth were divided into groups according to ICDAS-II classification, and scanned with Cerec Omnicam (Dentsply Sirona) and iTero Element Flex (Align Technology). The caries-infected tissues were removed regarding either minimally invasive or conventional cavity principles. Samples were scanned again and volumetric data were assessed by Meshmixer 3.5 (Autodesk) 3D modeling software. Statistical evaluations were performed with Mann Whitney U test and Spearman’s Correlation test. The significance level was α=0.05. Results: Although there was a significant difference between obtained …
The Effects Of Boric Acid On The Water Solubility Of Glass Ionomer Cements, Banu Cukurluoz Bayındır, İrem Bağ
The Effects Of Boric Acid On The Water Solubility Of Glass Ionomer Cements, Banu Cukurluoz Bayındır, İrem Bağ
Journal of Dentistry Indonesia
Changing the water solubility property of glass ionomer cement (GIC), which is frequently used in pediatric dentistry, is the starting point of this study. Objective: To evaluate the effects of boric acid on the water solubility (WS) of GIC. Methods: The samples were prepared as n=12 in each of four groups: GIC-Conventional glass ionomer cement; BGIC with 1:3 boric acid added to conventional GIC powder; RMGIC-resin-modified glass ionomer cement; BRMGIC with 1:3 boric acid added to RMGIC powder. Weight changes were compared 1, 3 and 24 h after keeping in distilled water. One sample in each group was …
Impacts Of A Duf2207 Family Protein On Streptococcus Mutans Stress Tolerance Responses And Biofilm Formation, Xiaochang Huang, Camile G. Laird, Paul P. Riley, Zezhang Tom Wen
Impacts Of A Duf2207 Family Protein On Streptococcus Mutans Stress Tolerance Responses And Biofilm Formation, Xiaochang Huang, Camile G. Laird, Paul P. Riley, Zezhang Tom Wen
School of Dentistry Faculty Publications
Locus SMU.243 in Streptococcus mutans was annotated as a member of the DUF2207 family proteins highly conserved in all bacteria but with unknown function. To investigate its role in S. mutans physiology, a SMU.243-deficient mutant was constructed using allelic exchange mutagenesis, and the impacts of SMU.243 deletion on bacterial growth, stress tolerance response, and biofilm formation were analyzed. Compared to the wild-type UA159, S. mutans lacking SMU.243 displayed a reduced growth rate and a reduced overnight culture density (p < 0.01) when grown at low pH and in the presence of methyl viologen. Relative to the parent strain, the deficient mutant also had a reduced survival rate following incubation in a buffer of pH 2.8 (p < 0.01) and in a buffer containing hydrogen peroxide at 58 mM after 60 min (p < 0.001) and had a reduced capacity in biofilm formation especially in the presence of sucrose (p < 0.01). To study any ensuing functional/phenotypical links between SMU.243 and uppP, which is located immediately downstream of SMU.243 and encodes an undecaprenyl pyrophosphate phosphatase involved in recycling of carrier lipid undecaprenyl phosphate, a uppP deficient mutant was generated using allelic exchange mutagenesis. Unlike the SMU.243 mutant, deletion of uppP affected cell envelope biogenesis and caused major increases in susceptibility to bacitracin. In addition, two variant morphological mutants, one forming rough colonies and the other forming mucoid, smooth colonies, also emerged following the deletion of uppP. The results suggest that the SMU.243-encoded protein of the DUF2207 family in S. mutans plays an important role in stress tolerance response and biofilm formation, but unlike the downstream uppP, does not seem to be involved in cell envelope biogenesis, although the exact roles in S. mutans’ physiology awaits further investigation.
Accuracy And Trueness Of Exporting Computer Aided Designs Of 3-Unit Fixed Dental Prosthesis By 3 Cad Systems, Ezzat Abou-Alnaga, Ashraf Hussein, Ahmed Naguib, Shereen Ahmed Nossair
Accuracy And Trueness Of Exporting Computer Aided Designs Of 3-Unit Fixed Dental Prosthesis By 3 Cad Systems, Ezzat Abou-Alnaga, Ashraf Hussein, Ahmed Naguib, Shereen Ahmed Nossair
Future Dental Journal
Objectives: Computer-aided design (CAD) software programs offer the option to export 3D scans and designs across different CADCAM systems, commonly referred to as open CADCAM technology. However, there is insufficient evidence of whether this exporting procedure has an impact on the accuracy of digital designs.This study aimed to investigate the accuracy of exporting of computer aided designs (CAD) of three-unit fixed dental prosthesis using 3 CAD systems. Materials and Methods: Three CAD softwares (inLab 17™, CeraMill Mind™, Dental System 2017™) were used to generate designs of a three-unit fixed partial denture. The designs generated by each CAD software were exported …
Current Oral Hygiene And Recreational Behavioral Trends In Hiv Disease, Donald E. Mercante, Emily Guarisco, Elizabeth A. Lilly, Arni Rao, Kelly Treas, Clifford J. Beall, Zach Thompson, Ann L. Griffen, Eugene J. Leys, Jose A. Vazquez, Michael E. Hagensee, Paul L. Fidel
Current Oral Hygiene And Recreational Behavioral Trends In Hiv Disease, Donald E. Mercante, Emily Guarisco, Elizabeth A. Lilly, Arni Rao, Kelly Treas, Clifford J. Beall, Zach Thompson, Ann L. Griffen, Eugene J. Leys, Jose A. Vazquez, Michael E. Hagensee, Paul L. Fidel
School of Dentistry Faculty Publications
Objective: HIV disease is evolving with more HIV+ persons experiencing a high quality of life with well-controlled viremia. We recently enrolled a large cohort of HIV+ and clinically relevant HIV− persons for oral microbiome analyses that included a questionnaire related to oral hygiene and recreational behaviors. Here, the questionnaire responses were analyzed for behavioral trends within the cohort, together with trends over time by comparison to a previous geographically centered HIV+ cohort. Methods: Data were collected by questionnaire at baseline visits as cross-sectional assessments. Multivariable analyses were conducted for associations of HIV status as well as age, race, and sex, …
The Effect Of Two Sintering Cycles And Aging On Biaxial Flexural Strength Of Strength Gradient Multi-Layered Zirconia (An Vitro Study), Passent Hm El Galab, Maged Zohdy, Fatma Makkeyah, Mustafa Noor
The Effect Of Two Sintering Cycles And Aging On Biaxial Flexural Strength Of Strength Gradient Multi-Layered Zirconia (An Vitro Study), Passent Hm El Galab, Maged Zohdy, Fatma Makkeyah, Mustafa Noor
Dentistry
No abstract provided.
Assessment Of The Effect Of Two Different Digital Fabrication Techniques On Marginal And Internal Fit Of Interim Fixed Dental Prothesis, Mohamed A. Shalaby, Mennatallah M. Wahba, Hisham I. Al-Ansari, Ahmed N. Mohamed
Assessment Of The Effect Of Two Different Digital Fabrication Techniques On Marginal And Internal Fit Of Interim Fixed Dental Prothesis, Mohamed A. Shalaby, Mennatallah M. Wahba, Hisham I. Al-Ansari, Ahmed N. Mohamed
Future Dental Journal
Aim: The aim of that study was to evaluate the marginal and internal fit of a 3-unit, and 6-unit interim fixed dental prosthesis manufactured through milling and 3D printing technologies. Materials and Methods: Forty-eight interim fixed dental prostheses (FDP) were equally divided into two groups according to the fabrication technique. In group (MT), specimens were fabricated through milling technology while in group (PT), specimens were obtained by 3D printing. Each group was subdivided equally according to the FDP span length into 3-unit FDP (SFDP), and 6-unit FDP (LFDP). Marginal and internal fit were measured through the superimposition of the digital …
Digital Fabrication Of Attachment For Implant-Anchored Auricular Prosthesis (Case Report)., Hussein El Charkawi Proffesor
Digital Fabrication Of Attachment For Implant-Anchored Auricular Prosthesis (Case Report)., Hussein El Charkawi Proffesor
Future Dental Journal
Aim: This novel technique, has adopted digital technology to fabricate a customized precision attachment for a patient who has lost his attachment which anchor his implant retained auricular prosthesis. A scanner was used to acquire the ball abutment’ geometry of craniofacial implant in the mastoid area. CAD/CAM technology and special software was used to fabricate a customized small PEEK precision attachment that was no longer available in the market. This attachment was picked-up by an auricular prosthesis. The retention qualities of the auricular prosthesis with this attachment was satisfactory for both the patient and the dentist. This novel approach will …
Computer Guided Versus Conventional Maxillary Sinus Augmentation Using Allogenic Bone Blocks With Simultaneous Implant Placement In Severely Pneumatized Sinuses, Hisham G. Zulhemma Department Of Oral And Maxillofacial Surgery, Future University In Egypt, Egypt. [email protected], Waleed Ragab El-Beialy Professor Of Oral And Maxillofacial Surgery -Cairo University, Egypt. [email protected], Ahmed Abd Elsamad Associate Professor Of Oral And Maxillofacial Radiology– Cairo University, Egypt. [email protected], Ahmed Abozekry Lecturer Of Oral And Maxillofacial Surgery –Future University In Egypt, Egypt. [email protected]
Computer Guided Versus Conventional Maxillary Sinus Augmentation Using Allogenic Bone Blocks With Simultaneous Implant Placement In Severely Pneumatized Sinuses, Hisham G. Zulhemma Department Of Oral And Maxillofacial Surgery, Future University In Egypt, Egypt. [email protected], Waleed Ragab El-Beialy Professor Of Oral And Maxillofacial Surgery -Cairo University, Egypt. [email protected], Ahmed Abd Elsamad Associate Professor Of Oral And Maxillofacial Radiology– Cairo University, Egypt. [email protected], Ahmed Abozekry Lecturer Of Oral And Maxillofacial Surgery –Future University In Egypt, Egypt. [email protected]
Future Dental Journal
Background: Maxillary sinus lifting is a complex procedure with reported complications in the literature where the presence of sinus septa further complicates the procedure, they including membrane perforation, bleeding. Aim: The aim of this study is to decrease the incidence of membrane perforation which is the most common reported complication, and to determine whether the use of surgical guides could decrease the incidence of membrane perforation. Materials and methods: A total of 12 cases where blindly divided into 2 groups; Group (A) computer guided maxillary sinus lifting and Group (B) conventional sinus lifting, both groups received allogenic bone blocks for …
Defining Success In Healthcare Education: Us Dental Student And Faculty Perspectives., David Alexandre Cruz Walma, Mathieu Alexander Cruz Walma, Shirin Khoynezhad, Sang E. Park, Carly Timmons Mckenzie, Et Al
Defining Success In Healthcare Education: Us Dental Student And Faculty Perspectives., David Alexandre Cruz Walma, Mathieu Alexander Cruz Walma, Shirin Khoynezhad, Sang E. Park, Carly Timmons Mckenzie, Et Al
School of Dentistry Faculty Publications
Purpose/objectives Academic metrics and clinical performance are necessary but alone insufficient in describing success in dental education. This paper identifies themes critical for dental student success as commonly cited by both dental students and faculty. Methods Dental faculty interviews and pre-doctoral D2/D3/D4 student focus groups at two dental institutions generated data for thematic analysis. Themes were individually identified then merged, compared, and contrasted to establish a definitive list of key themes reflected in student and faculty comments. Results Twenty-five pre-doctoral students participated in one of four focus groups (two focus groups at each dental institution). Thirteen dental education faculty across …
Acceptability Of Fully Guided Virtual Implant Planning Software Among Dental Undergraduate Students, Shishir Ram Shetty, Colin Murray, Sausan Al Kawas, Sara Jaser, Wael Talaat, Medhini Madi, Vinayak Kamath, Nisha Manila, Raghavendra Shetty, Vidya Ajila
Acceptability Of Fully Guided Virtual Implant Planning Software Among Dental Undergraduate Students, Shishir Ram Shetty, Colin Murray, Sausan Al Kawas, Sara Jaser, Wael Talaat, Medhini Madi, Vinayak Kamath, Nisha Manila, Raghavendra Shetty, Vidya Ajila
School of Dentistry Faculty Publications
Background: Fully guided implant surgery as a technique is gaining popularity. It has been observed that use of surgical guides improves precision and predictability for dental implant placement. However, like any other newer technology, the acceptance of fully guided dental implant technology among users is based upon its perceived usability. This study aimed at evaluating the perception about using Virtual Implant Planning Software (VIPS) among undergraduate dental students at the university of Sharjah. Methods: Ninety-Six dental surgery students from the University of Sharjah were included in the study. One week after the Virtual Implant Planning Software (Planmeca Romexis version 6.2 …
Analysis Of Changes In Gingiva-Occlusal Parameters As Perceived By Three Middle-East Populations, Nadine Nachabeh, Tony Daher, Elie Maalouf, Khalil Kharma, Eliane Kaydouh, Carina Mehanna
Analysis Of Changes In Gingiva-Occlusal Parameters As Perceived By Three Middle-East Populations, Nadine Nachabeh, Tony Daher, Elie Maalouf, Khalil Kharma, Eliane Kaydouh, Carina Mehanna
International Arab Journal of Dentistry
Purpose. This study aims to compare the effect of various smile parameters (buccal corridor, gummy smile, midline to face discrepancy, with and without upper lip filling) on the perception of smile attractiveness by applying the digital modification of images judged by one hundred and eighty laypersons from different Middle East populations.
Materials and Methods. A frontal photo of a woman’s smile is manipulated with Photoshop to modify each smile parameter gradually into 3 grades. The total number of smiles to be assessed is 18. One hundred and eighty participants divided into 3 groups (n=60: 30 men and 30 women): …
Distal Cantilever Length Comparison In Esthetic Materials For Hybrid Implant Prostheses: An In Vitro Study, Sana Shams Eddin, Elie Jasser, Mohammad Chams Eddin, Carole Abi Ghosn Yared, Joseph Makzoumi, Paul Boulos
Distal Cantilever Length Comparison In Esthetic Materials For Hybrid Implant Prostheses: An In Vitro Study, Sana Shams Eddin, Elie Jasser, Mohammad Chams Eddin, Carole Abi Ghosn Yared, Joseph Makzoumi, Paul Boulos
International Arab Journal of Dentistry
Objective: the assessment of distal cantilever length in implant supported prothesis (Hybrid prosthesis) by comparing the load to fracture in two different esthetic framework materials (Zirconia and Polyetheretherketone (PEEK)) with two different cantilevers loading distances (10mm, 15mm).
Material and methods: 20 frameworks were fabricated and divided into 4 groups (n=5): according to the material type, Peek, zirconia, and according to the cantilever loading distance (10), or (15) mm and a load-to-fracture test was used until complete fracture of specimens occurs.
Results: The effect of material type and cantilever loading distance were statistically significant for the mean load-to-fracture …