Determining The Termination Percentage Of Heart Rate Maximum For Submaximal Testing, Julia A. Valentour Jan 2001

Determining The Termination Percentage Of Heart Rate Maximum For Submaximal Testing, Julia A. Valentour

College of Graduate Studies: Theses & Dissertations (1964–2006)

BACKGROUND: In the Fourth Edition of the American College of Sports Medicine's Guidelines for Exercise Testing and Prescription (1991). the protocol for the ACSM's submaximal bike test was to terminate the test at 65-70% of the age predicted maximal heart rate. In the Fifth Edition, this was changed to 85% of the age-predicted maximal heart rate.

OBJECTIVES: The purpose of this study was to find out, by using the ACSM submaximal cycle ergometer test (see Appendix A) if the 85% heart rate maximum termination provides a more accurate estimate of maximal aerobic capacity than the 70% heart rate maximum termination. …


The Reliability And Validity Of The Pacer For 3rd And 4th Grade Males, Jennifer A. Hinely Jan 2001

The Reliability And Validity Of The Pacer For 3rd And 4th Grade Males, Jennifer A. Hinely

College of Graduate Studies: Theses & Dissertations (1964–2006)

BACKGROUND: FITNESSGRAM recommends the use of the PACER, a 20-meter shuttle run, to assess the aerobic ability of children in physical education classes.

OBJECTIVES: To examine the reliability and validity of the PACER for 3rd and 4th grade males. In addition, the reliability and validity of the criterion-referenced standards will be examined.

METHODS: 22 students ran 3 trials of the FITNESSGRAM PACER while wearing the Cosmed K4b2 system.

RESULTS: From the 22 students, the intraclass correlation for the number of laps for trial 2 to trial 3 was 0.81. The reliability of the estimated VO2 from trial 2 to trial …


Aerobic Respiratory Costs Of Swimming In The Negatively Buoyant Brief Squid Lolliguncula Brevis, Ian K. Bartol, Roger Mann, Mark R. Patterson Jan 2001

Aerobic Respiratory Costs Of Swimming In The Negatively Buoyant Brief Squid Lolliguncula Brevis, Ian K. Bartol, Roger Mann, Mark R. Patterson

Biological Sciences Faculty Publications

Because of the inherent inefficiency of jet propulsion, squid are considered to be at a competitive disadvantage compared with fishes, which generally depend on forms of undulatory/oscillatory locomotion. Some squid, such as the brief squid Lolliguncula brevis, swim at low speeds in shallow-water complex environments, relying heavily on fin activity. Consequently, their swimming costs may be lower than those of the faster, more pelagic squid studied previously and competitive with those of ecologically relevant fishes. To examine aerobic respiratory swimming Costs, O2 consumption rates were measured for L. brevis of various sizes (2-9 cm. dorsal mantle length, DML) …