Culminating Course Progress Report For The Na893 Community Support Center, Yokosuka Naval Base, Japan, Kazuo Miura Jun 2020

Culminating Course Progress Report For The Na893 Community Support Center, Yokosuka Naval Base, Japan, Kazuo Miura

Fire Protection Engineering: Culminating Experience Project Reports

This is the culminating project report for the Fire Project Engineering Master’s of Science at California Polytechnic at San Luis Obispo. This project will consider a project for the US military in Japan, JFY893 Community Support Facility, Yokosuka Naval Base. The subject facility consists of a library, education center, family services, and other community services. The Library shall serve as the Main Base Library, keep and store books and provide library services for active duty population, dependents and retirees. The Education Center provides services for advancing of the academic, technical, and vocational education of military personnel of all grades and …


Cal Poly State University Robert E. Kennedy Library Fire Protection Analysis Report, Timothy Anderson Jun 2019

Cal Poly State University Robert E. Kennedy Library Fire Protection Analysis Report, Timothy Anderson

Fire Protection Engineering: Culminating Experience Project Reports

This report determines whether or not the fire protection and life safety features of Robert E. Kennedy Library are consistent with the fire protection objectives established in nationally recognized fire protection codes and standards. This analysis is performed to establish a technical baseline for identification of fire protection deficiencies.

Kennedy Library is the campus student library at California Polytechnic State University. The facility provides resources and services in a variety of media to meet the needs of university students and faculty.

This analysis consists of a prescriptive analysis and a performance-based analysis. The prescriptive analysis is an analysis of the …


Prescriptive And Performance Analysis Of Cold Machine Shop, John Kline Jun 2018

Prescriptive And Performance Analysis Of Cold Machine Shop, John Kline

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this report is to analyze the fire and life safety aspects of the Cold Machine Shop located on the central coast of California. This report includes both a prescriptive and performance based analysis.

The prescriptive analysis will evaluate the building as follows, to ensure compliance with standard codes: 1)Egress analysis and design using NFPA 101, "Life Safety Code", 2)Fire detection, alarms, and communication systems using NFPA 72, "National Fire Alarm and Signaling Code", 3)Water-based fire suppression systems using NFPA 13, " Standard for Installation of Sprinkler Systems" and NFPA 14, " Standard for the Installation of Standpipe …


Shyh Wang Hall- Lbnl Building 59, Mike Torkelson Jun 2018

Shyh Wang Hall- Lbnl Building 59, Mike Torkelson

Fire Protection Engineering: Culminating Experience Project Reports

This report details the fire and life safety analysis of Shyh Wang Hall, a new building at the Lawrence Berkeley National Laboratory. Wang Hall houses offices, high performance computers, and associated mechanical space. The building is constructed as a Type IIB structure and includes four stories. Both prescriptive-based and performance-based design is considered.

The prescriptive analysis considers the fire and life safety features as required by applicable codes, including the Department of Energy requirements. The building is protected by fire detection and alarm system as well as automatic sprinklers. The prescriptive design meets the code requirements with the possible exception …


Warren J. Baker Center For Science And Mathematics (Csm)- Fire Protection Analysis, Neal Larsen Jun 2018

Warren J. Baker Center For Science And Mathematics (Csm)- Fire Protection Analysis, Neal Larsen

Fire Protection Engineering: Culminating Experience Project Reports

Analyzing the fire protection features of the Warren J. Baker Center for Science and Mathematics Building 180, located on Cal Poly Campus in San Luis Obispo California was done using two methods. The prescriptive based analysis of the building focused on the building design, egress, structural fire protection, fire suppression, fire alarm and detection systems to determine if current codes and standards were meet. The performance based analysis discusses certain methods and design fire scenarios that are present within the building and the building’s ability to protect occupants until they can exit safely. The performance based analysis was done using …


General Purpose Laboratory Building 33- Lawrence Berkeley National Laboratory, Nicholas Tran Jun 2018

General Purpose Laboratory Building 33- Lawrence Berkeley National Laboratory, Nicholas Tran

Fire Protection Engineering: Culminating Experience Project Reports

A detailed study of the fire and life safety systems in the General Purpose Laboratory at the Lawrence Berkeley National Laboratory was performed. The prescriptive and performance-based methods for fire and life safety requirements were analyzed in accordance with the applicable codes. The prescriptive items examined included the egress capacities, fire suppression systems, fire detection and notification systems, and structural construction requirements. The performance-based models utilized studied fire growth and its impact on the fire suppression systems as well as time to egress for the occupants. The General Purpose Laboratory was found to be compliant with the prescriptive requirements in …


Fire And Life Safety Analysis- College Campus Building, Jacob Ludeman Mar 2018

Fire And Life Safety Analysis- College Campus Building, Jacob Ludeman

Fire Protection Engineering: Culminating Experience Project Reports

A Fire and Life Safety Analysis was performed as an academic exercise as part of the MS Fire Protection Engineering Program of California Polytechnic State University, San Luis Obispo. The project is a culminating report with regards to prescriptive based and performance based aspects for the fire and life safety analysis of a project building. These analyses were performed on a building located on a college campus in Southern California and is to remain nameless upon the request of the owner and architect. The building is in the School of Physical Sciences at the University it resides. The building houses …


Fire And Life Safety Analysis Of The Production Facility (Pf)- 870, Nolan Baker Dec 2017

Fire And Life Safety Analysis Of The Production Facility (Pf)- 870, Nolan Baker

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of the fire and life-safety analysis was to perform a prescriptive-based and performance based analysis on the fire and life safety systems in the Production Facility (PF) at Sandia National Laboratories (SNL). The prescriptive-based analysis determined if the building met applicable code requirements for existing life safety systems. The performance-based analysis consisted of a series of fire scenarios to ensure the fire and life safety systems allowed adequate egress time for occupants in the event of a fire. The prescriptive-based analysis was based on the Life Safety Code (LSC) and the International Building Code (IBC). The occupancy of …


Dci Data Center Building- Fire Protection Analysis, Bryan Hathaway Jun 2017

Dci Data Center Building- Fire Protection Analysis, Bryan Hathaway

Fire Protection Engineering: Culminating Experience Project Reports

A fire protection analysis utilizing prescriptive and performance based design was performed for the existing building (DCIB) located in Minnesota. A new tenant is investigating converting the DCIB from a building used for data center, to an office building which will utilize an open office concept.

A prescriptive analysis of the building was performed to determine the life safety, fire suppression, fire alarm and structural requirements to ensure compliance with current applicable codes and standards. The prescriptive requirements are outlined and reviewed in Section 1 through Section 5 of this analysis. Modifications to the DCIB are required to achieve the …


Taft Community College- New Student Center- Fire And Life Safety Analysis, Matthew Winston Jun 2017

Taft Community College- New Student Center- Fire And Life Safety Analysis, Matthew Winston

Fire Protection Engineering: Culminating Experience Project Reports

The following report is a fire and life safety investigation into a new facility. The planned facility is a new Student Center at Taft Community College. The prescriptive requirements as set forth by the most up to date codes and standards chosen for the project are met. The building has been properly classified with respect to occupancy and construction type. Appropriate design for interior partitions and exterior walls have been identified. Interior finish requirements are elaborated so that adherence to these guidelines is made clear. The fire sprinkler system has an adequate supply of water from the municipal water supply …


Los Angeles Air Force Base Fitness Center, Colin White Jun 2017

Los Angeles Air Force Base Fitness Center, Colin White

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this report is to evaluate the life safety features of the Los Angeles Air Force Base Fitness Center, located on Los Angeles Air Force Base in El Segundo, California. This report is produced in partial fulfillment of the requirements of a Master’s of Science in Fire Protection Engineering from the Fire Protection Engineering Program at California Polytechnic State University’s San Luis Obispo Campus. This analysis approaches life safety in the fitness center from two angles. First, a prescriptive approach is used to evaluate the building’s compliance with current codes and standards that govern construction and maintenance of …


Recreation Center- Cal Poly- Fire And Life Safety Analysis, Hao Yan Jun 2017

Recreation Center- Cal Poly- Fire And Life Safety Analysis, Hao Yan

Fire Protection Engineering: Culminating Experience Project Reports

This report discusses the fire and life safety analysis of the existing fire protection features installed in the Recreation Center building on the California Polytechnic State University. The analysis is conducted using two different approaches, the prescriptive analysis of the building and the performance-based design analysis.

The prescriptive analysis approach will examine installed fire protection features and systems in accordance with the International Building Code, such as structural fire protection, water-based suppression system, alarm and detection system, egress system, smoke control, and fire safety management plan. The egress system failed when the old gym area was used as a fixed …


Acme Semiconductor Foundry- Fab Expansion- Fire Protection Engineering Analysis Report, Jacob Epstein Jun 2017

Acme Semiconductor Foundry- Fab Expansion- Fire Protection Engineering Analysis Report, Jacob Epstein

Fire Protection Engineering: Culminating Experience Project Reports

The ACME Semiconductor Foundry – Fab Expansion is a new four story addition to an existing four story foundry facility. The Fab Expansion is approximately 154,500 square feet in footprint area that is connected to an existing four-story Fab Building. This report has been prepared to identify the building’s fire protection and life safety features that must be provided in accordance with the applicable codes and standards. The ACME Semiconductor Fab Expansion will contain multiple separated uses and will be required to be constructed with Type I-B construction. Building Construction Documents are provided in Appendix A showing compliance with the …


Orfalea College Of Business Fire Safety Analysis, Garth Ornelas Mar 2017

Orfalea College Of Business Fire Safety Analysis, Garth Ornelas

Fire Protection Engineering: Culminating Experience Project Reports

The following report discusses the fire and life safety factors for the Orfalea College of Business Building located on the main campus of California Polytechnic State University in San Luis Obispo. The building functions are primarily administrative and academic in nature, with various lecture halls, offices, and labs located throughout the building. The Business Building was constructed in 1989 following the 1985 Uniform Building Code (UBC). For the purposes of this report, the building will be evaluated using the 2015 International Building Code, NFPA Life Safety Code Handbook (Thirteenth Edition), SFPE Handbook (4th and 5th Editions), and the NFPA handbooks …


Fire And Life Safety Evaluation Of Christopher Cohan Center, Mishuk Datta Mar 2017

Fire And Life Safety Evaluation Of Christopher Cohan Center, Mishuk Datta

Fire Protection Engineering: Culminating Experience Project Reports

A prescriptive and performance-based fire and life safety evaluation for Christopher Cohan Center is performed. The results and findings of the evaluations are conveyed in this report. Christopher Cohan Center was built in accordance with California Building Code (1992 Edition) and California Fire Code (1992 Edition). The current version (2015) of International Building Code is consulted for prescriptive evaluation. The protection requirements set forth in IBC are intended to limit the threat from stage fires to an audience, to reduce the likelihood of a large fire in the stage area and to reduce the possibility of irrational mass response. These …


Fire And Safety Analysis Robert E. Kennedy Library, Marius Bjelde Andersen Mar 2017

Fire And Safety Analysis Robert E. Kennedy Library, Marius Bjelde Andersen

Fire Protection Engineering: Culminating Experience Project Reports

The Robert E. Kennedy Library is located on Cal Poly Campus. The Library is a five-story building with different occupancies which consists of library areas, offices, mechanical equipment and storage areas. The building has a total area of 178 702 ft². The original code of construction for the Library was the 1976 Uniform Building code (UBC). However, the fire and life safety analysis of the building in this report is performed using: Egress: NFPA 101 LSC 2015, Water based suppression: NFPA 13, Structural fire protection: 2015 IBC, Fire detection, alarm and communication systems: NFPA 72, Performance based design: NFPA 101 …


Building- Fire Protection Analysis Report, Chris Schwendiman Mar 2017

Building- Fire Protection Analysis Report, Chris Schwendiman

Fire Protection Engineering: Culminating Experience Project Reports

The building in XXX was constructed in XXX. It was designed using the International Building Code (IBC). This fire protection analysis report will be reviewing the building based on the 2015 edition of the IBC including several performance based fire scenarios involving the smoke exhaust system.

The passive system section highlights the physical construction of the building. The building is a business occupancy with three separate stories including a penthouse which is included in the third story. The building has adequate fire ratings for a Type II-B construction except for heavy timber columns within the commons of the building. It …


Fire And Life Safety Analysis- Warren J. Baker Center For Science And Mathematics, Chad Rudolph Graves Mar 2017

Fire And Life Safety Analysis- Warren J. Baker Center For Science And Mathematics, Chad Rudolph Graves

Fire Protection Engineering: Culminating Experience Project Reports

This report covers the fire protection features of the Warren J. Baker Center for Science and Mathematics located on Cal Poly Campus San Luis Obispo California. The prescriptive analysis of the building will focus on the structural fire protection, egress, fire suppression, fire alarm and detection systems to determine if the meet current codes and standards. The performance based analysis will discuss certain methods and design fire scenarios that can be present within the building and the buildings ability to protect occupants until they can exit safely.

The purpose of this report is to determine if the selected building is …


Pitkin Charter School, Scott Decker Jun 2016

Pitkin Charter School, Scott Decker

Fire Protection Engineering: Culminating Experience Project Reports

The Loew’s Pitkin building is a renovation of a movie/stage theater built in 1929. Over the next three decades the neighborhood declined and the theater closed in the Nineteen Sixties. The building was then a church for a while and then retail space with the theater auditorium empty. The building was finally abandoned in the Seventies and deteriorated until the early part of the next century. The School board of New York City took possession of the vacant structure and turned it into PS 159. It is a grade school serving grades from kindergarten to fifth grade and special education. …


Analysis Of The Seattle Customer Delivery Center, Cynthia Wernet Jun 2016

Analysis Of The Seattle Customer Delivery Center, Cynthia Wernet

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this analysis is to assess how the Customer Delivery Center (CDC) satisfies prescriptive design requirements of the 2012 International Building Code (IBC) for fire exiting, structural design, smoke detection, alarm notification and communication and water-based fire suppression. A performance-based analysis is then performed using hand calculations and computer-based models to determine if the available safe egress time exceeds the required safe egress time from the building. In order to complete this analysis, the issued-for-construction design and the contractor submittals were made accessible by the owner’s fire protection engineer and the project management group overseeing construction. These documents …


Office Building- Fire Protection Systems Evaluation, Christine Newton Jun 2016

Office Building- Fire Protection Systems Evaluation, Christine Newton

Fire Protection Engineering: Culminating Experience Project Reports

This report is a Life Safety Code (LSC) and fire protection systems evaluation of an office building located in Colorado. This report covers the prescriptive analysis of the building, as well as the performance‐based aspect of the evaluation.

The prescriptive analysis of this report includes assessment of the building code for structural design, means of egress, detection and notification systems, smoke control system, and the water‐ based fire suppression system for this building. The 2012 International Building Code (IBC) and the National Fire Protection Agency (NFPA) 101 LSC were used for the prescriptive based evaluation and the building was determined …


Sheraton Hotel- Life Safety Report, Raul M. Farfan Jun 2016

Sheraton Hotel- Life Safety Report, Raul M. Farfan

Fire Protection Engineering: Culminating Experience Project Reports

This report evaluates the prescriptive life safety requirements for levels one (1) through four (4) of the Sheraton Hotel in downtown Phoenix. In addition, this report discusses two fire scenarios that evaluate the tenability during egress the in pre-function area on level two (2) and in the main ballroom on level three (3) of the hotel.

The prescriptive standards/codes used to evaluate the hotel are the International Building Code (IBC), International Fire Code (IFC), and applicable standards from the National Fire Protection Association (NFPA). Performance based analysis were conducted using Pathfinder, CFast, and Fire Dynamic Simulator (FDS). Two fire scenarios …


Henderson Engineers Building- Fire Protection, Life Safety Code Compliance, And Key Issues Report, Alex Ataiyan Jun 2016

Henderson Engineers Building- Fire Protection, Life Safety Code Compliance, And Key Issues Report, Alex Ataiyan

Fire Protection Engineering: Culminating Experience Project Reports

A fire protection and life safety analysis of the Henderson Engineers, Inc. (HEI) building in Lenexa, KS (Kansas City) is performed. Both prescriptive and performance-based methods have been used to evaluate the building against the codes and standards of the 2012 International Building Code (IBC).

The following prescriptive fire protection and life safety systems were analyzed: Occupancy Classification, Building Construction Type, Fire Protection Features, Structural Fire Protection, Fire Barriers, Automatic Fire Sprinkler System, Fire Alarm System, and Means of Egress

During the prescriptive approach, the following deficiencies were identified: 1) As-builts indicate a horizontal assembly fire-resistance rating of only 1-hour, …


Office High Rise Building- Fire Protection And Life Safety Analysis, Fabio Renato Zocal Mazza Jun 2016

Office High Rise Building- Fire Protection And Life Safety Analysis, Fabio Renato Zocal Mazza

Fire Protection Engineering: Culminating Experience Project Reports

This project developed the traditional prescriptive-based design analysis of the fire protection features of an existing office high rise building in the city of Sao Paulo, in Brazil. The analysis was then complemented by performance-based analysis of the building. The building is a high rise office located in a metropolitan area, provided also with underground car parking garages and a small theater. The fire protection analysis was conducted based on the local Sao Paulo state fire codes, mainly the Sao Paulo State enactment (Decreto Nº56.819/2011) and Sao Paulo Fire Department Technical Instructions; and, in addition to the local codes, the …


Maintenance Shop Building- Comprehensive Fire Protection Evaluation, Theodore P. Stanton Mar 2016

Maintenance Shop Building- Comprehensive Fire Protection Evaluation, Theodore P. Stanton

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this report is to analyze the fire protection systems and features of the Maintenance Shop Building (MSB), which is a two story office and training building on the campus of a large industrial facility in central California. The goal of the fire protection systems and features of the Building is to provide occupants with reasonable assurance of safety from fire. This goal can be met by ensuring that occupants not intimate with the initiation of a fire will be able to safely escape from the Building in the event of the fire.

The ability of the MSB’s …


Technical Area 3 - 40; Physics Building- Fire And Life Safety Analysis, Parker Fellows Mar 2016

Technical Area 3 - 40; Physics Building- Fire And Life Safety Analysis, Parker Fellows

Fire Protection Engineering: Culminating Experience Project Reports

A Fire Protection Engineering Analysis was performed on TA‐3‐0040, Physics Building at the Los Alamos National Laboratory in Los Alamos, New Mexico. The goal of the analysis has two parts; first, to examine the buildings fire protection features from a code based prescriptive analysis and second, to examine the building and fire protection features using a performance based design analysis.

Building 40 is a 2 story structure approximately 187,000 square feet. The building was constructed in the mid‐1950s with a first floor, basement, partial sub‐basement, and various mezzanines. Originally, this building was constructed as a non‐combustible type IIB structure according …


Taylor Place- Fire Life Safety Report, Christopher Thomas Mar 2016

Taylor Place- Fire Life Safety Report, Christopher Thomas

Fire Protection Engineering: Culminating Experience Project Reports

This document is a Fire and Life Safety Report on the Taylor Place Dormitory located in Phoenix, Arizona as part of the Arizona State University (ASU) downtown campus. The building was evaluated on a prescriptive basis based on the current City of Phoenix building codes and further evaluated on using performance based methods from the Society of Fire Protection Engineers (SFPE) Handbook and National Fire Protection Association (NFPA) 101 Life Safety Code®.

These building features and systems were evaluated using prescriptive methods:

General construction, fire resistive construction and fire resistive separations Occupancy, Life safety features and building egress Smoke management …


Fire Hazard Analysis Of Technical Area 53 Building 1, Los Alamos National Lab, Brett L. Noakes Jun 2015

Fire Hazard Analysis Of Technical Area 53 Building 1, Los Alamos National Lab, Brett L. Noakes

Fire Protection Engineering: Culminating Experience Project Reports

This is an analysis of a 1970’s vintage building as it is compared to current building codes and standards. The purpose of this document is to assess if the current, as found construction of an existing building could achieve the sometimes more restrictive modern building codes. Both a prescriptive analysis and a performance-based analysis were completed to verify life-safety concerns and criteria as well as construction criteria. The prescriptive analysis compared existing, as found construction to current codes and standards while the prescriptive analysis used modern fire modeling techniques to see how likely fire scenarios would challenge the structure, if …


Fire And Life Safety Report- Battalion Headquarters Complex (Ueph), Mathew Mershimer Jun 2015

Fire And Life Safety Report- Battalion Headquarters Complex (Ueph), Mathew Mershimer

Fire Protection Engineering: Culminating Experience Project Reports

This fire and life safety report covers a Battalion Headquarters Complex that is used for housing military troops. This is a complete review of the building with prescriptive based fire protection along with performance base review of the building. The prescriptive fire protection covers egress analysis of the space, passive fire protection (i.e. fire walls and doors) and active fire protection (i.e. fire alarm and fire sprinklers). The performance based section looks at the prescriptive requirements and sees if these would be enough for the application at hand. The building fire protection and life safety are covered by three different …


Solar Energy Research Center- Lawrence Berkeley National Laboratory!, Shellie Prescott Mar 2015

Solar Energy Research Center- Lawrence Berkeley National Laboratory!, Shellie Prescott

Fire Protection Engineering: Culminating Experience Project Reports

This report covers both a prescriptive and performance-based review of fire and life safety systems for the Solar Energy Research Center at the Lawrence Berkeley National Laboratory. The primary subjects covered are egress, fire alarm systems, and sprinkler systems. A unique feature and focal point for this report is the SERC east exit stair. This stair was originally designed as a glass atrium, but for various reasons cannot be utilized as an atrium. The east exit stair has a special VESDA detection system, is the most remote location for the sprinkler system, and is a primary exit for all three …