Open Access. Powered by Scholars. Published by Universities.®
- Institution
- Keyword
-
- Additive manufacturing (8)
- Microstructure (8)
- Mechanical properties (7)
- 3D printing (6)
- Mechanotransduction (6)
-
- Peridynamics (6)
- Plate (6)
- Tissue engineering (6)
- Biomechanics (5)
- Design (5)
- Shear stress (5)
- Atherosclerosis (4)
- Finite element analysis (4)
- Finite element method (4)
- Graphene (4)
- Machine learning (4)
- Manufacturing (4)
- Mechanobiology (4)
- Porosity (4)
- Resonator (4)
- Composite (3)
- Crystal (3)
- Deep learning (3)
- Directed energy deposition (3)
- Elliptical (3)
- Magnesium (3)
- Metasurface (3)
- Metrology (3)
- Optical coherence tomography (3)
- Peripheral artery disease (3)
- Publication Year
- Publication
-
- Department of Mechanical and Materials Engineering: Faculty Publications (530)
- Mechanical Engineering (4)
- Williams Honors College, Honors Research Projects (4)
- Master's Theses (2)
- Student Works (2020-2029) (2)
-
- All Undergraduate Projects (1)
- Architectural Engineering (1)
- BioResource and Agricultural Engineering (1)
- Birck and NCN Publications (1)
- Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research (1)
- Dissertations, Master's Theses and Master's Reports (1)
- Electronic Theses and Dissertations (1)
- Honors Theses (1)
- LSU Doctoral Dissertations (1)
- Optical Science and Engineering ETDs (1)
- The Summer Undergraduate Research Fellowship (SURF) Symposium (1)
- Theses and Dissertations (1)
- Publication Type
Articles 451 - 480 of 554
Full-Text Articles in Other Mechanical Engineering
Thickness-Shear Vibration Of A Rectangular Quartz Plate With Partial Electrodes, Huijing He, Jiashi Yang, John A. Kosinski, Ji Wang
Thickness-Shear Vibration Of A Rectangular Quartz Plate With Partial Electrodes, Huijing He, Jiashi Yang, John A. Kosinski, Ji Wang
Department of Mechanical and Materials Engineering: Faculty Publications
We study free vibration of a thickness-shear mode crystal resonator of AT-cut quartz. The resonator is a rectangular plate partially and symmetrically electroded at the center with rectangular electrodes. A single-mode, three-dimensional equation governing the thickness-shear displacement is used. A Fourier series solution is obtained. Numerical results calculated from the series show that there exist trapped thickness-shear modes whose vibration is mainly under the electrodes and decays rapidly outside the electrodes. The effects of the electrode size and thickness on the trapped modes are examined.
Room-Temperature Organic Ferromagnetism In The Crystalline Poly(3-Hexylthiophene): Phenyl-C61-Butyric Acid Methyl Ester Blend Film, Bin Yang, Zhengguo Xiao, Yongbo Yuan, Tanjore V. Jayaraman, Jeffrey E. Shield, Ralph Skomski, Jinsong Huang
Room-Temperature Organic Ferromagnetism In The Crystalline Poly(3-Hexylthiophene): Phenyl-C61-Butyric Acid Methyl Ester Blend Film, Bin Yang, Zhengguo Xiao, Yongbo Yuan, Tanjore V. Jayaraman, Jeffrey E. Shield, Ralph Skomski, Jinsong Huang
Department of Mechanical and Materials Engineering: Faculty Publications
Pronounced ferromagnetism was observed in a crystalline blend film of conjugated polymer poly(3-hexylthiophene) (P3HT) and phenyl-C61-butyric acid methyl ester (PCBM) by using magnetic force microscopy measurements. A substantial room-temperature saturation magnetization of about 0.65 emu g−1 was measured by an alternating gradient field magnetometer. Multiple experimental evidences demonstrate the charge transfer from the P3HT to the PCBM and the formation of P3HT crystal domain are expected to be two critical factors for the originals of room-temperature organic ferromagnetism.
A Mathematical Evaluation Of Hemodynamic Parameters After Carotid Eversion And Conventional Patch Angioplasty, Alexey Kamenskiy, Iraklis I. Pipinos, Yuris A. Dzenis, Prateek K. Gupta, Syed A. Jaffar Kazmi, Jason N. Mactaggart
A Mathematical Evaluation Of Hemodynamic Parameters After Carotid Eversion And Conventional Patch Angioplasty, Alexey Kamenskiy, Iraklis I. Pipinos, Yuris A. Dzenis, Prateek K. Gupta, Syed A. Jaffar Kazmi, Jason N. Mactaggart
Department of Mechanical and Materials Engineering: Faculty Publications
Carotid endarterectomy has a long history in stroke prevention, yet controversy remains concerning optimal techniques. Two methods frequently used are endarterectomy with patch angioplasty (CEAP) and eversion endarterectomy (CEE). The objective of this study was to compare hemodynamics-related stress and strain distributions between arteries repaired using CEAP and CEE. Mathematical models were based on in vivo three-dimensional arterial geometry, pulsatile velocity profiles, and intraluminal pressure inputs obtained from 16 patients with carotid artery disease. These data were combined with experimentally derived nonlinear, anisotropic carotid artery mechanical properties to create fluid-structure interaction models of CEAP and CEE. These models were then …
Effects Of Mode Coupling On The Admittance Of An At-Cut Quartz Thickness-Shear Resonator, Huijing He, Jiashi Yang, Wei-Ping Zhang, Ji Wang
Effects Of Mode Coupling On The Admittance Of An At-Cut Quartz Thickness-Shear Resonator, Huijing He, Jiashi Yang, Wei-Ping Zhang, Ji Wang
Department of Mechanical and Materials Engineering: Faculty Publications
We study the effects of couplings to flexure and face-shear modes on the admittance of an AT-cut quartz plate thickness-shear mode resonator. Mindlin’s two-dimensional equations for piezoelectric plates are employed. Electrically forced vibration solutions are obtained for three cases: pure thickness-shear mode alone; two coupled modes of thickness shear and flexure; and three coupled modes of thickness shear, flexure, and face shear. Admittance is calculated and its dependence on the driving frequency and the length/thickness ratio of the resonator is examined. Results show that near the thickness-shear resonance, admittance assumes maxima, and that for certain values of the length/thickness ratio, …
A Comparative Study Of The Dry And Wet Nano-Scale Electro-Machining, M. P. Jahan, K. R. Virwani, Kamlakar P. Rajurkar, A. P. Malshe
A Comparative Study Of The Dry And Wet Nano-Scale Electro-Machining, M. P. Jahan, K. R. Virwani, Kamlakar P. Rajurkar, A. P. Malshe
Department of Mechanical and Materials Engineering: Faculty Publications
In recent years, a nano-electromachining (nano-EM) process based on a scanning tunneling microscope (STM) platform has been demonstrated. Nano-EM is capable of machining nano-features, under both, liquid dielectric (wet nano-EM) and air dielectric (dry nano-EM) media. The objective of this paper is to present a comparative study between the wet and dry nano-EM processes based on process mechanism, machining performance, consistency and dimensional repeatability of these two processes. The comparison of the two processes has been conducted at near field nano-EM, where the gap between the tool electrode and workpiece is 2 nm and the machining is performed at room …
Inducing Neurite Outgrowth By Mechanical Cell Stretch, Suzanne Higgins, Jeong Soon Lee, Ligyeom Ha, Jung Yul Lim
Inducing Neurite Outgrowth By Mechanical Cell Stretch, Suzanne Higgins, Jeong Soon Lee, Ligyeom Ha, Jung Yul Lim
Department of Mechanical and Materials Engineering: Faculty Publications
Establishing extracellular milieus to stimulate neuronal regeneration is a critical need in neuronal tissue engineering. Many studies have used a soluble factor (such as nerve growth factor or retinoic acid [RA]), micropatterned substrate, and electrical stimulation to induce enhanced neurogenesis in neuronal precursor cells. However, little attention has been paid to mechanical stimulation because neuronal cells are not generally recognized as being mechanically functional, a characteristic of mechanoresponsive cells such as osteoblasts, chondrocytes, and muscle cells. In this study, we performed proof-of-concept experiments to demonstrate the potential anabolic effects of mechanical stretch to enhance cellular neurogenesis. We cultured human neuroblastoma …
Systems Biology Of The Functional And Dysfunctional Endothelium, Jennifer Frueh, Nataly Maimari, Takayuki Homma, Sandra M. Bovens, Ryan M. Pedrigi, Leila Towhidi, Rob Krams
Systems Biology Of The Functional And Dysfunctional Endothelium, Jennifer Frueh, Nataly Maimari, Takayuki Homma, Sandra M. Bovens, Ryan M. Pedrigi, Leila Towhidi, Rob Krams
Department of Mechanical and Materials Engineering: Faculty Publications
This review provides an overview of the effect of blood flow on endothelial cell (EC) signalling pathways, applying microarray technologies to cultured cells, and in vivo studies of normal and atherosclerotic animals. It is found that in cultured ECs, 5–10% of genes are up- or down-regulated in response to fluid flow, whereas only 3–6% of genes are regulated by varying levels of fluid flow. Of all genes, 90%are regulated by the steady part of fluid flow and 10% by pulsatile components. The associated gene profiles show high variability from experiment to experiment depending on experimental conditions, and importantly, the bioinformatical …
Solution-Processed Nanoparticle Super-Float-Gated Organic Field-Effect Transistor As Un-Cooled Ultraviolet And Infrared Photon Counter, Yongbo Yuan, Qingfeng Dong, Bin Yang, Fawen Guo, Qi Zhang, Ming Han, Jinsong Huang
Solution-Processed Nanoparticle Super-Float-Gated Organic Field-Effect Transistor As Un-Cooled Ultraviolet And Infrared Photon Counter, Yongbo Yuan, Qingfeng Dong, Bin Yang, Fawen Guo, Qi Zhang, Ming Han, Jinsong Huang
Department of Mechanical and Materials Engineering: Faculty Publications
High sensitivity photodetectors in ultraviolet (UV) and infrared (IR) range have broad civilian and military applications. Here we report on an un-cooled solution-processed UV-IR photon counter based on modified organic field-effect transistors. This type of UV detectors have light absorbing zinc oxide nanoparticles (NPs) sandwiched between two gate dielectric layers as a floating gate. The photon-generated charges on the floating gate cause high resistance regions in the transistor channel and tune the source-drain output current. This ‘‘super-float-gating’’ mechanism enables very high sensitivity photodetectors with a minimum detectable ultraviolet light intensity of 2.6 photons/µm2s at room temperature as well …
Analysis Of Electrically-Forced Vibrations Of Piezoelectric Mesa Resonators, Huijing He, Guo-Quan Nie, Jin-Xi Liu, Jiashi Yang
Analysis Of Electrically-Forced Vibrations Of Piezoelectric Mesa Resonators, Huijing He, Guo-Quan Nie, Jin-Xi Liu, Jiashi Yang
Department of Mechanical and Materials Engineering: Faculty Publications
We study the electrically forced thickness-shear and thickness-twist vibrations of stepped thickness piezoelectric plate mesa resonators made of polarized ceramics or 6-mm class crystals. A theoretical analysis based on the theory of piezoelectricity is performed, and an analytical solution is obtained using the trigonometric series. The electrical admittance, resonant frequencies, and mode shapes are calculated, and strong energy trapping of the modes is observed. Their dependence on the geometric parameters of the resonator is also examined.
Review Of Electrochemical And Electrodischarge Machining, Kamlakar P. Rajurkar, M. M. Sundaram, A. P. Malshe
Review Of Electrochemical And Electrodischarge Machining, Kamlakar P. Rajurkar, M. M. Sundaram, A. P. Malshe
Department of Mechanical and Materials Engineering: Faculty Publications
Electrochemical and electro-discharge machining processes are the two major electro-machining processes with unique capabilities. Electrical Discharge Machining (EDM) and Electrochemical Machining (ECM) offer a better alternative or sometimes the only alternative in generating accurate 3-D complex shaped macro, micro and nano features and components of difficult–to-machine materials. Technological advances reported in electrochemical and electro discharge machining processes, which reflect the state of the art in academic and industrial research and applications, are briefly reviewed in this paper.
Wire Electro-Discharge Machining Of Titanium Alloy, Farnaz Nourbakhsh, Kamlakar P. Rajurkar, Ajay P. Malshe, Jian Cao
Wire Electro-Discharge Machining Of Titanium Alloy, Farnaz Nourbakhsh, Kamlakar P. Rajurkar, Ajay P. Malshe, Jian Cao
Department of Mechanical and Materials Engineering: Faculty Publications
This paper presents an experimental investigation of wire electro-discharge machining (WEDM) of titanium alloy. The objective is to investigate the effect of seven process parameters including pulse width, servo reference voltage, pulse current, and wire tension on process performance parameters (such as cutting speed, wire rupture and surface integrity). A Taguchi L18 design of experiment (DOE) has been applied. All experiments have been conducted using Charmilles WEDM. It was also found that the cutting speed increases with peak current and pulse interval. Surface roughness was found to increase with pulse width and decrease with pulse interval. The Analysis of Variance …
Selective Detection And Automated Counting Of Fluorescently-Labeled Chrysotile Asbestos Using A Dual-Mode High-Throughput Microscopy (Dm-Htm) Method, Myoung-Ock Cho, Hyo Mi Chang, Donghee Lee, Yeon Gyu Yu, Hwataik Han, Jung Kyung Kim
Selective Detection And Automated Counting Of Fluorescently-Labeled Chrysotile Asbestos Using A Dual-Mode High-Throughput Microscopy (Dm-Htm) Method, Myoung-Ock Cho, Hyo Mi Chang, Donghee Lee, Yeon Gyu Yu, Hwataik Han, Jung Kyung Kim
Department of Mechanical and Materials Engineering: Faculty Publications
Phase contrast microscopy (PCM) is a widely used analytical method for airborne asbestos, but it is unable to distinguish asbestos from non-asbestos fibers and requires time-consuming and laborious manual counting of fibers. Previously, we developed a high-throughput microscopy (HTM) method that could greatly reduce human intervention and analysis time through automated image acquisition and counting of fibers. In this study, we designed a dual-mode HTM (DM-HTM) device for the combined reflection and fluorescence imaging of asbestos, and automated a series of built-in image processing commands of ImageJ software to test its capabilities. We used DksA, a chrysotile-adhesive protein, for selective …
Photovoltaic Device, Jinsong Huang, Bin Yang, Yongbo Yuan
Photovoltaic Device, Jinsong Huang, Bin Yang, Yongbo Yuan
Department of Mechanical and Materials Engineering: Faculty Publications
An apparatus includes a substrate; and a photoactive layer disposed on the substrate. The photoactive layer includes an electron acceptor material; an electron donor material; and a material having dipoles.
Energy Trapping Of Thickness-Shear And Thickness-Twist Modes In A Partially Electroded At-Cut Quartz Resonator, Huijing He, Guoquan Nie, Jinxi Liu, Jiashi Yang
Energy Trapping Of Thickness-Shear And Thickness-Twist Modes In A Partially Electroded At-Cut Quartz Resonator, Huijing He, Guoquan Nie, Jinxi Liu, Jiashi Yang
Department of Mechanical and Materials Engineering: Faculty Publications
The thickness-shear and thickness-twist vibrations of a finite and partially electroded AT-cut quartz resonator are investigated. The equations of anisotropic elasticity are used with the omission of the small elastic constant c56 . An analytical solution is obtained using Fourier series from which the free vibration resonant frequencies, mode shapes, and energy trapping are calculated and examined.
Maximal Force Characteristics Of The Ca2+-Powered Actuator Of Vorticella Convallaria, Sangjin Ryu, Matthew J. Lang, Paul Matsudaira
Maximal Force Characteristics Of The Ca2+-Powered Actuator Of Vorticella Convallaria, Sangjin Ryu, Matthew J. Lang, Paul Matsudaira
Department of Mechanical and Materials Engineering: Faculty Publications
The millisecond stalk contraction of the sessile ciliate Vorticella convallaria is powered by energy from Ca2+ binding to generate contractile forces of ~10 nN. Its contractile organelle, the spasmoneme, generates higher contractile force under increased stall resistances. By applying viscous drag force to contracting V. convallaria in a microfluidic channel, we observed that the mechanical force and work of the spasmoneme depended on the stalk length, i.e., the maximum tension (150–350 nN) and work linearly depended on the stalk length (~2.5 nN and ~30 fJ per 1 mm of the stalk). This stalk-length dependency suggests that motor units of …
Shear-Horizontal Vibration Modes Of An Oblate Elliptical Cylinder And Energy Trapping In Contoured Acoustic Wave Resonators, Huijing He, Jiashi Yang, John A. Kosinski
Shear-Horizontal Vibration Modes Of An Oblate Elliptical Cylinder And Energy Trapping In Contoured Acoustic Wave Resonators, Huijing He, Jiashi Yang, John A. Kosinski
Department of Mechanical and Materials Engineering: Faculty Publications
We study shear-horizontal free vibrations of an elastic cylinder with an oblate elliptical cross section and a traction-free surface. Exact vibration modes and frequencies are obtained. The results show the existence of thickness-shear and thickness-twist modes. The energy-trapping behavior of these modes is examined. Trapped modes are found wherein the vibration energy is largely confined to the central portion of the cross section and little vibration energy is found at the edges. It is also shown that face-shear modes are not allowed in such a cylinder. The results are useful for the understanding of the energy trapping phenomenon in contoured …
Nonlinear Mechanical Behavior Of The Human Common, External And Internal Carotid Arteries In Vivo, Alexey Kamenskiy, Yuris A. Dzenis, Jason N. Mactaggart, Thomas G. Lynch, Syed A. Jaffar Kazmi, Iraklis I. Pipinos
Nonlinear Mechanical Behavior Of The Human Common, External And Internal Carotid Arteries In Vivo, Alexey Kamenskiy, Yuris A. Dzenis, Jason N. Mactaggart, Thomas G. Lynch, Syed A. Jaffar Kazmi, Iraklis I. Pipinos
Department of Mechanical and Materials Engineering: Faculty Publications
Introduction—The mechanical environment and properties of the carotid artery play an important role in the formation and progression of atherosclerosis in the carotid bifurcation. The purpose of this work was to measure and compare the range and variation of circumferential stress and tangent elastic moduli in the human common (CCA), external (ECA) and internal (ICA) carotid arteries over the cardiac cycle in vivo.
Methods—Measurements were performed in the surgically exposed proximal cervical CCA, distal ECA and distal ICA of normotensive patients (n = 16) undergoing carotid endarterectomy. All measurements were completed in vivo over the cardiac cycle …
Three-Dimensional Geometry Of The Human Carotid Artery, Alexey Kamenskiy, Jason N. Mactaggart, Iraklis I. Pipinos, Jai Bikhchandani, Yuris A. Dzenis
Three-Dimensional Geometry Of The Human Carotid Artery, Alexey Kamenskiy, Jason N. Mactaggart, Iraklis I. Pipinos, Jai Bikhchandani, Yuris A. Dzenis
Department of Mechanical and Materials Engineering: Faculty Publications
Accurate characterization of carotid artery geometry is vital to our understanding of the pathogenesis of atherosclerosis. Three-dimensional computer reconstructions based on medical imaging are now ubiquitous; however, mean carotid artery geometry has not yet been comprehensively characterized. The goal of this work was to build and study such geometry based on data from 16 male patients with severe carotid artery disease. Results of computerized tomography angiography were used to analyze the cross-sectional images implementing a semiautomated segmentation algorithm. Extracted data were used to reconstruct the mean three-dimensional geometry and to determine average values and variability of bifurcation and planarity angles, …
Rehabilitation And Exercise Machine, Judith M. Burnfield, Yu Shu, Thad W. Buster, Carl Nelson
Rehabilitation And Exercise Machine, Judith M. Burnfield, Yu Shu, Thad W. Buster, Carl Nelson
Department of Mechanical and Materials Engineering: Faculty Publications
An improved rehabilitation and exercise machine is provided which allows a person with physical limitations, disabilities or chronic conditions to use the machine in order to rehabilitate their muscles, improve joint flexibility, and enhance cardiovascular fitness.
Model-Based Systems And Methods For Analyzing And Predicting Outcomes Of Vascular Interventions And Reconstructions, Yuris A. Dzenis, Alexey Kamenskiy, Iraklis I. Pipinos, Jason N. Mactaggart
Model-Based Systems And Methods For Analyzing And Predicting Outcomes Of Vascular Interventions And Reconstructions, Yuris A. Dzenis, Alexey Kamenskiy, Iraklis I. Pipinos, Jason N. Mactaggart
Department of Mechanical and Materials Engineering: Faculty Publications
Systems and methods for analyzing and predicting treatment outcomes of medical procedures such as vascular interventions and reconstructions are disclosed. An illustrative system for analyzing and predicting therapeutic outcomes of medical procedures comprises a relational database configured for classifying and storing patient specific input data for multiple patients, a fluid-solid interaction biomechanical model configured for performing a biomechanics simulation and generating biomechanics data, and a graphical user interface.
Effects Of Mismatched Electrodes On An At-Cut Quartz Resonator, Huijing He, Jinxi Liu, Jiashi Yang
Effects Of Mismatched Electrodes On An At-Cut Quartz Resonator, Huijing He, Jinxi Liu, Jiashi Yang
Department of Mechanical and Materials Engineering: Faculty Publications
We study thickness-shear and thickness-twist free vibrations of a finite AT-cut quartz resonator with mismatched electrodes. The equations of anisotropic elasticity are used with the omission of the small elastic constant c56. An analytical solution is obtained using Fourier series from which the resonant frequencies, mode shapes, and vibration confinement resulting from the electrode inertia are calculated and examined.
Method For Increasing The Efficiency Of Organic Photovoltaic Cells, Jinsong Huang, Yongbo Yuan
Method For Increasing The Efficiency Of Organic Photovoltaic Cells, Jinsong Huang, Yongbo Yuan
Department of Mechanical and Materials Engineering: Faculty Publications
The present invention is directed to an organic photovoltaic cell that contains one or more dipole regions generally disposed between an organic active region and the electrodes and a process for producing such an organic photovoltaic cell.
Macro And Microfluidic Flows For Skeletal Regenerative Medicine, Brandon D. Riehl, Jung Yul Lim
Macro And Microfluidic Flows For Skeletal Regenerative Medicine, Brandon D. Riehl, Jung Yul Lim
Department of Mechanical and Materials Engineering: Faculty Publications
Fluid flow has a great potential as a cell stimulatory tool for skeletal regenerative medicine, because fluid flow-induced bone cell mechanotransduction in vivo plays a critical role in maintaining healthy bone homeostasis. Applications of fluid flow for skeletal regenerative medicine are reviewed at macro and microscale. Macroflow in two dimensions (2D), in which flow velocity varies along the normal direction to the flow, has explored molecular mechanisms of bone forming cell mechanotransduction responsible for flow-regulated differentiation, mineralized matrix deposition, and stem cell osteogenesis. Though 2D flow set-ups are useful for mechanistic studies due to easiness in in situ and post-flow …
Sacrificial Structure Preforms For Thin Part Machining, Scott Smith, Robert Wilhelm, Brian Dutterer, Harish Cherukuri, Gaurav Goel
Sacrificial Structure Preforms For Thin Part Machining, Scott Smith, Robert Wilhelm, Brian Dutterer, Harish Cherukuri, Gaurav Goel
Department of Mechanical and Materials Engineering: Faculty Publications
Thin parts are often difficult to create by machining because they have insufficient static and dynamic stiffness. Accurate thin parts are difficult to achieve due to clamping forces, cutting forces, residual stresses, and chatter. Sacrificial structure preforms support the part during machining, but they are not part of the finished component. Preforms may be created in many ways, including forging, welding, gluing, casting, or additive processes. They can be used in many workpiece materials including metals, polymers, and ceramics. We describe a novel process that uses sacrificial structures to make machining insensitive to the thinness of finished parts.
Moisture Damage Characterization Of Warm-Mix Asphalt Mixtures Based On Laboratory-Field Evaluation, Yong-Rak Kim, Jun Zhang, Hoki Ban
Moisture Damage Characterization Of Warm-Mix Asphalt Mixtures Based On Laboratory-Field Evaluation, Yong-Rak Kim, Jun Zhang, Hoki Ban
Department of Mechanical and Materials Engineering: Faculty Publications
This study presents laboratory evaluation integrated with field performance to examine two widely used warm-mix asphalt (WMA) approaches—foaming and emulsion technology. For a more realistic evaluation of the WMA approaches, trial pavement sections of the WMA mixtures and their counterpart hot-mix asphalt (HMA) mixtures were implemented in Antelope County, Nebraska. Field-mixed loose mixtures collected at the time of paving were transported to the laboratories to conduct various experimental evaluations of the individual mixtures. Among the laboratory tests, three (two conventional and one newly attempted) were performed to characterize moisture damage potential which is the primary focus of this study. From …
Monitoring The Wall Mechanics During Stent Deployment In A Vessel, Brian Steinert, Shijia Zhao, Linxia Gu
Monitoring The Wall Mechanics During Stent Deployment In A Vessel, Brian Steinert, Shijia Zhao, Linxia Gu
Department of Mechanical and Materials Engineering: Faculty Publications
Clinical trials have reported different restenosis rates for various stent designs . It is speculated that stentinduced strain concentrations on the arterial wall lead to tissue injury, which initiates restenosis . This hypothesis needs further investigations including better quantifications of non-uniform strain distribution on the artery following stent implantation. A non-contact surface strain measurement method for the stented artery is presented in this work. ARAMIS stereo optical surface strain measurement system uses two optical high speed cameras to capture the motion of each reference point, and resolve three dimensional strains over the deforming surface. As a mesh stent is deployed …
Thickness-Shear And Thickness-Twist Modes In An Oblate Elliptical Ceramic Cylinder And Energy Trapping In Contoured Acoustic Wave Resonators, Huijing He, Jiashi Yang, Yi-Hua Huang
Thickness-Shear And Thickness-Twist Modes In An Oblate Elliptical Ceramic Cylinder And Energy Trapping In Contoured Acoustic Wave Resonators, Huijing He, Jiashi Yang, Yi-Hua Huang
Department of Mechanical and Materials Engineering: Faculty Publications
We study shear-horizontal motions of a piezoelectric ceramic cylinder with an oblate elliptical cross section and axial poling. Exact thickness-shear and thickness-twist vibration modes are obtained. These modes show energy trapping, i.e., the vibration is mainly confined near the thick, central region and decays to almost nothing near the edges. The results are useful for the understanding and design of contoured piezoelectric resonators for strong energy trapping.
Systems And Synthetic Biology Of The Vessel Wall, Jennifer Frueh, Nataly Maimari, Ying Lui, Zoltan Kis, Vikram Mehta, Negin Pormehr, Calum Grant, Emmanuel Chalkias, Mika Falck-Hansen, Sandra Bovens, Ryan M. Pedrigi, Taka Homma, Gianfillippo Coppola, Rob Krams
Systems And Synthetic Biology Of The Vessel Wall, Jennifer Frueh, Nataly Maimari, Ying Lui, Zoltan Kis, Vikram Mehta, Negin Pormehr, Calum Grant, Emmanuel Chalkias, Mika Falck-Hansen, Sandra Bovens, Ryan M. Pedrigi, Taka Homma, Gianfillippo Coppola, Rob Krams
Department of Mechanical and Materials Engineering: Faculty Publications
Atherosclerosis is intimately coupled to blood flow by the presence of predilection sites. The coupling is through mechanotransduction of endothelial cells and approximately 2000 gene are associated with this process. This paper describes a new platform to study and identify new signalling pathways in endothelial cells covering an atherosclerotic plaque. The identified networks are synthesized in primary cells to study their reaction to flow. This synthetic approach might lead to new insights and drug targets.
Nanotopographic Cell Culture Substrate: Polymer-Demixed Nanotextured Films Under Cell Culture Conditions, Jung Yul Lim, Christopher A. Siedlecki, Henry J. Donahue
Nanotopographic Cell Culture Substrate: Polymer-Demixed Nanotextured Films Under Cell Culture Conditions, Jung Yul Lim, Christopher A. Siedlecki, Henry J. Donahue
Department of Mechanical and Materials Engineering: Faculty Publications
Modulating physical cell culture environments via nanoscale substrate topographic modification has recently been of significant interest in regenerative medicine. Many studies have utilized a polymer-demixing technique to produce nanotextured films and showed that cellular adhesion, proliferation, and differentiation could be regulated by the shape and scale of the polymer-demixed nanotopographies. However, little attention has been paid to the topographic fidelity of the polymer-demixed films when exposed to cell culture conditions. In this brief article, two polymer-demixing systems were employed to assess topographic changes in polymer-demixed films after fibronectin (FN) extracellular matrix protein adsorption and after incubation in phosphate-buffered saline at …
Usability Assessment Of Two Different Control Modes For The Master Console Of A Laparoscopic Surgical Robot, Xiaoli Zhang, Carl A. Nelson, Dmitry Oleynikov
Usability Assessment Of Two Different Control Modes For The Master Console Of A Laparoscopic Surgical Robot, Xiaoli Zhang, Carl A. Nelson, Dmitry Oleynikov
Department of Mechanical and Materials Engineering: Faculty Publications
The objective of this study is to evaluate potential interface control modes for a compact fourdegree- of-freedom (4-DOF) surgical robot. The goal is to improve robot usability by incorporating a sophisticated haptics-capable interface. Two control modes were developed using a commercially available haptic joystick: (1) a virtually point-constrained interface providing an analog for constrained laparoscopic motion (3-DOF rotation and 1-DOF translation), and (2) an unconstrained Cartesian input interface mapping more directly to the surgical tool tip motions. Subjects (n = 5) successfully performed tissue identification and manipulation tasks in an animal model in point-constrained and unconstrained control modes, respectively, with …