Open Access. Powered by Scholars. Published by Universities.®

Electro-Mechanical Systems Commons

Open Access. Powered by Scholars. Published by Universities.®

2006

Discipline
Institution
Keyword
Publication
Publication Type

Articles 1 - 6 of 6

Full-Text Articles in Electro-Mechanical Systems

Output Feedback Adaptive Variable Structure Control Of A Smart Projectile Fin, Smitha Mani, Sahjendra N. Singh, Woosoon Yim Aug 2006

Output Feedback Adaptive Variable Structure Control Of A Smart Projectile Fin, Smitha Mani, Sahjendra N. Singh, Woosoon Yim

Mechanical Engineering Faculty Research

No abstract provided.


Socio-Economic Impacts Of Computer Viruses In Tanzania, M Victor Jun 2006

Socio-Economic Impacts Of Computer Viruses In Tanzania, M Victor

Tanzania Journal of Engineering and Technology (TJET)

This paper reports on a research project conducted with an objective of identifying and assessing various approaches used by different computer users (Management, System Administrators and end users) in Tanzania to combat computer viruses (CVs), and to assess users' awareness level on CVs. Specifically, the study aimed at assessing the awareness level on CVs to the Tanzanian business community; analyze the socio -economic impact caused by CVs in Tanzania and; assess existing methods, capacity and limitations on controlling CVs in Tanzania. Data was collected using both questionnaires and interview from financial institutions such as NBC and BOT, and telecommunications sector …


Characterization Of Stress In Gan-On-Sapphire Microelectromechanical Systems (Mems) Structures Using Micro-Raman Spectroscopy, Francisco E. Parada Mar 2006

Characterization Of Stress In Gan-On-Sapphire Microelectromechanical Systems (Mems) Structures Using Micro-Raman Spectroscopy, Francisco E. Parada

Theses and Dissertations

Micro-Raman (µRaman) spectroscopy is an efficient, non-destructive technique widely used to determine the quality of semiconductor materials and microelectromechanical systems. This work characterizes the stress distribution in wurtzite gallium nitride grown on c-plane sapphire substrates by molecular beam epitaxy. This wide bandgap semiconductor material is being considered by the Air Force Research Laboratory for the fabrication of shock-hardened MEMS accelerometers. µRaman spectroscopy is particularly useful for stress characterization because of its ability to measure the spectral shifts in Raman peaks in a material, and correlate those shifts to stress and strain. The spectral peak shift as a function of stress, …


Microelectromechanical Systems (Mems) Interrupter For Safe And Arm Devices, Steven S. Mink Mar 2006

Microelectromechanical Systems (Mems) Interrupter For Safe And Arm Devices, Steven S. Mink

Theses and Dissertations

This thesis addresses the development of a new micro-scale interrupter mechanism for a safe and arm device used in modern weapon systems. The interrupter mechanism often consists of a physical barrier that prevents an initial source of energy, in an explosive train, from being transferred to subsequent charges. In general, when the physical barrier is removed, the weapon is considered armed, and the charge is allowed to propagate. Several issues facing current safe and arm devices systems are the shrinking industrial base for manufacturing these devices and the desire for modern safe and arm devices to be compatible with next …


Power-Scavenging Mems Robots, Daniel J. Denninghoff Mar 2006

Power-Scavenging Mems Robots, Daniel J. Denninghoff

Theses and Dissertations

This thesis includes the design, modeling, and testing of novel, power-scavenging, biologically inspired MEMS microrobots. Over one hundred 500-μm and 990-μm microrobots with two, four, and eight wings were designed, fabricated, characterized. These microrobots constitute the smallest documented attempt at powered flight. Each microrobot wing is comprised of downward-deflecting, laser-powered thermal actuators made of gold and polysilicon; the microrobots were fabricated in PolyMUMPs® (Polysilicon Multi-User MEMS Processes). Characterization results of the microrobots illustrate how wing-tip deflection can be maximized by optimizing the gold-topolysilicon ratio as well as the dimensions of the actuator-wings. From these results, an optimum actuator-wing configuration was …


Magnetohydrodynamic Simulation Of Electromagnetic Pump In Tc-1, Lillian J. Ratliff Jan 2006

Magnetohydrodynamic Simulation Of Electromagnetic Pump In Tc-1, Lillian J. Ratliff

Reactor Campaign (TRP)

The pilot molten lead-bismuth target circuit (TC-1) in university of Nevada Las Vegas (UNLV) was designed for beam power of 1 MW accelerator driven system (ADS). The TC-1 is a liquid lead-bismuth eutectic (LBE) circulation loop. Circulation of the liquid alloy is driven by an annular linear induction pump (ALIP). Experimental measurements of system parameters have yielded a surprisingly low pump efficiency of less than 1%. A numerical study of the pump efficiency is being conducted to determine which operational parameters are responsible for this low efficiency and to give insight into future EM pump design. The numerical study will …