Open Access. Powered by Scholars. Published by Universities.®

Electro-Mechanical Systems Commons

Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering

Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 31 - 44 of 44

Full-Text Articles in Electro-Mechanical Systems

Hyperspectral Imaging For Characterizing Single Plasmonic Nanostructure And Single-Cell Analysis, Nishir Sanatkumar Mehta Oct 2018

Hyperspectral Imaging For Characterizing Single Plasmonic Nanostructure And Single-Cell Analysis, Nishir Sanatkumar Mehta

LSU Master's Theses

Orientation of plasmonic nanostructures is an important feature in many nanoscale applications such as photovoltaics, catalyst, biosensors DNA interactions, protein detections, hotspot of surface-enhanced Raman spectroscopy (SERS), and fluorescence resonant energy transfer (FRET) experiments. Silver nanocubes with significant spectral signatures between 400-700 nm are observed in this experimental research. Whereas study of single cells will enable the analysis of cell-to-cell variations within a heterogeneous population. These variations are important for further analysis and understanding of disease propagation, drug development, stem cell differentiation, embryos development, and how cells respond to each other and their environment. Adipose-derived mesenchymal stem cells possess the …


High-Throughput Nanoliter Dispensing Device For Biological Applications, Cole Reynolds, Euiwon Bae Dr., J Paul Robinson Dr. Aug 2018

High-Throughput Nanoliter Dispensing Device For Biological Applications, Cole Reynolds, Euiwon Bae Dr., J Paul Robinson Dr.

The Summer Undergraduate Research Fellowship (SURF) Symposium

Pathogen identification is a field that can contribute largely to the prevention of the spreading of illness and disease. In the past, pathogen identification has been a long and arduous process due to the time-consuming processes and steps that requires technician’s time and effort. With new technologies emerging however, screening of bacteria colonies can be done in a quick and high-throughput way. The problem is that using the current methods, bacteria cannot be transferred to petri dishes fast enough to keep up with the new screening methods. The current study focuses on exploring different methods to create an ergonomic device …


Chemotherapeutic Drug Cytotoxicity Measurement With A 3d Biomimetic Microfluidic Device And Computational Fluid Dynamics Model, Maryam Moarefian, Caroline Jones, Luke Achenie, Danesh Tafti May 2018

Chemotherapeutic Drug Cytotoxicity Measurement With A 3d Biomimetic Microfluidic Device And Computational Fluid Dynamics Model, Maryam Moarefian, Caroline Jones, Luke Achenie, Danesh Tafti

Biology and Medicine Through Mathematics Conference

No abstract provided.


Optimization Of Microfluidic Chip Fabrication Via Femtosecond Laser Ablation, Kenneth Aycock Apr 2018

Optimization Of Microfluidic Chip Fabrication Via Femtosecond Laser Ablation, Kenneth Aycock

Senior Theses

Microfluidic devices have become staple tools in biomedical research and have a promising future as low cost, point-of-care (POC) diagnostic devices. Despite the advancements in microfluidic device technology, the manipulation and fabrication of these systems can be tedious and expensive. Repeatable techniques in which computer-aided designs are translated into microfluidic systems in a matter of minutes are highly desirable both for researchers and manufacturers. Laser ablation of tape substrates has shown promise in producing cost-effective, rapidly manipulable devices, but the work done thus far has utilized continuous wave lasers that perform suboptimally due to the relatively short wavelengths used and …


Microfluidic Technology And Application In Urinal Analysis, Jiwen Xiang Feb 2018

Microfluidic Technology And Application In Urinal Analysis, Jiwen Xiang

LSU Doctoral Dissertations

Microfluidic technology offers numerous advantages in minimizing and integrating the traditional assays. However, the lack of efficient control components of the microfluidic systems has been hindering the widely commercialization of the technology. The research work in this dissertation focused on the development of effective control components for microfluidic applications.

A linear peristaltic pump was firstly designed, fabricated, and tested for conventional microfluidics by synchronously compressing the microfluidic channel with a miniature cam-follower system in Chapter 2. The miniature cam-follower system and microfluidic chip was prototyped using three-dimensional (3D) printing technology and soft lithography technology. Results from experimental test showed that …


Development Of Portable Hyperspectral Imaging Device, Chenxi Li, Youngkee Jung, Iyll-Joon Doh, Euiwon Bae Aug 2017

Development Of Portable Hyperspectral Imaging Device, Chenxi Li, Youngkee Jung, Iyll-Joon Doh, Euiwon Bae

The Summer Undergraduate Research Fellowship (SURF) Symposium

Most of the conventional hyperspectral imaging devices require sophisticated optical components, occupy a large footprint, and requires an initial capital investment for laboratories which mostly suits for laboratories benchtop system. The requirement of shipping the sample and waiting an extended period of time to get the results are the main downsides of this traditional approach. Capitalize in many specific field applications and diagnosis, portable devices provide both convenience and on-site results which are desirable for government agencies and food safety inspectors. This project was aimed to develop a low-cost, portable hyperspectral device for food safety applications. A smartphone was used …


Blood-Brain Barrier-On-A-Chip Systems Based On 3d Printing, Cade I. Harding May 2017

Blood-Brain Barrier-On-A-Chip Systems Based On 3d Printing, Cade I. Harding

Mechanical Engineering Undergraduate Honors Theses

This research focused on the design and testing of a blood-brain barrier (BBB)-on-a-chip microfluidic device produced using 3D printing. First, COMSOL simulations were used to define dimensions of the microchannel that would most accurately replicate the flow environment imposed on the blood-brain barrier, the wall shear stress being the most important characteristic. In using COMSOL, water was used as the simulated fluid and also the testing fluid in the fabricated devices. Therefore, the microsystem is designed to produce the BBB environment using water instead of blood. The numerical simulation parameters were based on theoretical calculations performed to scale up the …


Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee Aug 2016

Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee

The Summer Undergraduate Research Fellowship (SURF) Symposium

Hydrocephalus is a neurological disorder that typically requires a long-term implantation of a shunt system to manage its symptoms. These shunt systems are notorious for their extremely high failure rate. More than 40% of all implanted shunt systems fail within the first year of implantation. On average, 85% of all hydrocephalus patients with shunt systems undergo at least two shunt-revision surgeries within 10 years of implantation. A large portion of this high failure rate can be attributed to biofouling-related obstructions and infections. Previously, we developed flexible polyimide-based magnetic microactuators to remove obstructions formed on hydrocephalus shunts. To test the long-term …


Towards A Dynamic Clamp For Neurochemical Modalities, C. M. Rivera, H.-J. Kwon, A. Hashmi, Gu Yu, J. Zhao, J. Gao, J. Xu, Wei Xue, A. G. Dimitrov May 2015

Towards A Dynamic Clamp For Neurochemical Modalities, C. M. Rivera, H.-J. Kwon, A. Hashmi, Gu Yu, J. Zhao, J. Gao, J. Xu, Wei Xue, A. G. Dimitrov

Henry M. Rowan College of Engineering Departmental Research

The classic dynamic clamp technique uses a real-time electrical interface between living cells and neural simulations in order to investigate hypotheses about neural function and structure. One of the acknowledged drawbacks of that technique is the limited control of the cells’ chemical microenvironment. In this manuscript, we use a novel combination of nanosensor and microfluidic technology and microfluidic and neural simulations to add sensing and control of chemical concentrations to the dynamic clamp technique. Specifically, we use a microfluidic lab-on-a-chip to generate distinct chemical concentration gradients (ions or neuromodulators), to register the concentrations with embedded nanosensors and use the processed …


Fluid Powered Miniature In Vivo Robots For Minimally Invasive Surgery (Mis), Abolfazl Pourghodrat Aug 2014

Fluid Powered Miniature In Vivo Robots For Minimally Invasive Surgery (Mis), Abolfazl Pourghodrat

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Minimizing the invasiveness of surgery is believed to improve patient outcomes. Bleeding, infection, and pain are major concerns in surgery afflicting patients for decades. Minimally invasive techniques have come into play to reduce these concerns and smooth the evolution of abdominal surgery to a scarless process where nearly all surgeries can be performed without a skin incision. Technology continually advances the frontier of development of novel surgical devices to implement less invasive surgical techniques.

Fusion of robotics and Minimally Invasive Surgery (MIS) has created new opportunities to develop diagnostic and therapeutic tools. Surgical robotics is advancing from externally actuated systems …


Applying Spiking Neural Network Simulation To Neuromodulatory Autonomous Robot Control, Cameron Muhammad Jan 2014

Applying Spiking Neural Network Simulation To Neuromodulatory Autonomous Robot Control, Cameron Muhammad

Phi Kappa Phi Research Symposium (Archived)

In this paper, simulation of the brain based on an artificial spiking neuron model is used to create a self-learning algorithm. The spiking neuron simulation is used to demonstrate a neuromodulation program in which the reward seeking properties of dopamine, the risk-adverse effects of serotonin, and the attention-focusing effects of the cholinergic and noradrenergic systems are applied to a mobile robotic platform as it moves autonomously throughout an environment. External stimuli is recorded by the program as spiking “events” that result in corresponding amounts of dopamine and serotonin influenced spiking patterns. These spiking patterns affect how the robot adapts to …


Neuromodulation Based Control Of Autonomous Robots On A Cloud Computing Platform, Cameron Muhammad Jan 2014

Neuromodulation Based Control Of Autonomous Robots On A Cloud Computing Platform, Cameron Muhammad

College of Graduate Studies: Theses & Dissertations

In recent years, the advancement of neurobiologically plausible models and computer networking has resulted in new ways of implementing control systems on robotic platforms. The work presents a control approach based on vertebrate neuromodulation and its implementation on autonomous robots in the open-source, open-access environment of robot operating system (ROS). A spiking neural network (SNN) is used to model the neuromodulatory function for generating context based behavioral responses of the robots to sensory input signals. The neural network incorporates three types of neurons- cholinergic and noradrenergic (ACh/NE) neurons for attention focusing and action selection, dopaminergic (DA) neurons for rewards- and …


Design, Analysis And Testing Of Haptic Feedback System For Laparoscopic Graspers In In Vivo Surgical Robots, Nikhil Salvi Jul 2012

Design, Analysis And Testing Of Haptic Feedback System For Laparoscopic Graspers In In Vivo Surgical Robots, Nikhil Salvi

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Laparo-Endoscopic Single Site (LESS) Robotics Surgery is an advanced technology in the field of Minimally Invasive Surgery (MIS). The LESS surgical robots significantly improve the surgeon’s accuracy, dexterity and visualization, and reduce the invasiveness of surgical procedure results in faster recovery time and improved cosmetic results. In a standard robotic endosurgery, the palpation of tissues is performed by laparoscopic graspers located at the end effectors. The master-slave configuration in robotic surgery leads in remote access to the operation site. Therefore, surgeon’s ability to perceive valuable sensory information is severely diminished. Sensory information such as haptics, which is essential for safe …


Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser Jun 2012

Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser

Mechanical Engineering

Amputations are a common occurrence in soldiers returning home who have suffered the effects of IED and munitions explosions. For upper limb amputees, trans-radial amputations are the most common. Traditional hook devices do not offer an adequate level of normalcy for users, prompting the use of myoelectric devices. While current myoelectric devices do offer a more natural experience, they come with a host of other problems that makes their adoption by service personnel not desirable or not permitted by the VA. PolyGrasp Reach seeks to reduce weight and cost and improve performance. This addresses several of the issues with devices …