Open Access. Powered by Scholars. Published by Universities.®

Biomechanical Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

2017

Discipline
Institution
Keyword
Publication
Publication Type

Articles 31 - 41 of 41

Full-Text Articles in Biomechanical Engineering

Age-Related Differences In The Lumbopelvic Kinematics During The Trunk Motions In The Anatomical Planes, Milad Vazirian Jan 2017

Age-Related Differences In The Lumbopelvic Kinematics During The Trunk Motions In The Anatomical Planes, Milad Vazirian

Theses and Dissertations--Biomedical Engineering

Management and control of the low back pain as an important health problem in the industrial societies necessitates to investigate how the risk of this disease is affected by aging. Since the abnormalities of the lumbopelvic kinematics are related to the existence or risk of low back injuries, the objective of this dissertation was set to find the age-related differences in lumbopelvic kinematics when performing basic trunk motions reaching to range of motion in different anatomical planes.

A cross-sectional study was designed where sixty asymptomatic individuals between 20–70 years old with no confounding health condition, no current or previous highly …


Computational Investigation Of Transmural Differences In Left Ventricular Contractility And Hydrogel Injection Treatment For Myocardial Infarction, Hua Wang Jan 2017

Computational Investigation Of Transmural Differences In Left Ventricular Contractility And Hydrogel Injection Treatment For Myocardial Infarction, Hua Wang

Theses and Dissertations--Mechanical and Aerospace Engineering

Heart failure (HF) is one of the leading causes of death and impacts millions of people throughout the world. Recently, injectable hydrogels have been developed as a potential new therapy to treat myocardium infarction (MI). This dissertation is focused on two main topics: 1) to gain a better understanding the transmural contractility in the healthy left ventricle (LV) wall and 2) investigate the efficacy of the hydrogel injection treatment on LV wall stress and function. The results indicate that a non-uniform distribution of myocardial contractility in the LV wall provide a better representation of normal LV function. The other important …


Skintronics: Wireless, Skin-Wearable Electronics For Monitoring Of Electrocardiogram, Matthew B. Piper, Woon-Hong Yeo, Yongkuk Lee Jan 2017

Skintronics: Wireless, Skin-Wearable Electronics For Monitoring Of Electrocardiogram, Matthew B. Piper, Woon-Hong Yeo, Yongkuk Lee

Undergraduate Research Posters

The ECGs I micro-fabricate are designed to be flexible, stretchable and wireless circuits that can be applied to the skin directly. The device is encased in a conformal, silicon-like substrate, that allows the ECG to be attached with the electrodes. Each electrode has been previously measured and verified that it will be correctly placed for an accurate reading. Prototyping this ECG/electrode device allows the user to mount the prototype directly to the patient without having to attach and wire ten other electrodes. This prototype solves the issue that comes about when a doctor, nurse or emergency medical technician must attach …


Control Of A Powered Ankle-Foot Prosthesis: From Perception To Impedance Modulation, Guilherme Aramizo Ribeiro Jan 2017

Control Of A Powered Ankle-Foot Prosthesis: From Perception To Impedance Modulation, Guilherme Aramizo Ribeiro

Dissertations, Master's Theses and Master's Reports

Active ankle prostheses controllers are demonstrating gaining smart features to improve the safety and comfort offor users. The perception of user intention to modulate the ankle dynamics is a well-known example of such feature. But not much work focused on the perception of the environment, nor how the environment should be included in the mechanical design and control of the prosthesisprostheses. The proposed work aims to improve the feasibility of integrate the environment perception integration intoto the prostheses controllersler, and to define the desired ankle dynamics, as mechanical impedance, duringof the human walk on different environmental settings. As a preliminary …


Lighted Ear Curette, Kaitlin Klotzle, Kelsey Ashmore, Crysta Yamamoto, Katrina Elfrink, Cynthia Stoller Jan 2017

Lighted Ear Curette, Kaitlin Klotzle, Kelsey Ashmore, Crysta Yamamoto, Katrina Elfrink, Cynthia Stoller

Williams Honors College, Honors Research Projects

The ear canal is a sensitive and small part of the human body that is prone to accumulate cerumen or lodge foreign bodies. In order to clean the ear canal or remove foreign bodies, three hands are required: one to brace the patient's head, one to maneuver the curette that is used to clean the ear, and one to hold a light source in order to make the small, dark area visible. Therefore, a design is needed that can allow a doctor to safely clean an ear with an instrument that only requires two hands. Furthermore, the design must have …


Simulation Of Human Ankle Trajectory During Stance Phase Of Gait, Leslie Castelino Jan 2017

Simulation Of Human Ankle Trajectory During Stance Phase Of Gait, Leslie Castelino

Dissertations, Master's Theses and Master's Reports

A simulation was developed which mimics the human gait characteristics based on the input of an individual’s gait trajectory. This simulation also estimates the impedance of the human ankle based on the ground reaction forces measured by the force plate. This simulation will accept alterations of the following parameters: total body weight, weight of the shank, weight of the foot, trajectories of the shank and foot of the individual and orientation of the force plate, which would generate a new gait trajectory for the ankle during the stance phase of gait. The goal of this simulation was to validate the …


Finite Element Modeling Of The Plantar Fascia: A Viscohyperelastic Approach, Alexander Knapp Jan 2017

Finite Element Modeling Of The Plantar Fascia: A Viscohyperelastic Approach, Alexander Knapp

UNF Graduate Theses and Dissertations

The present work details the creation and analysis of a finite element model of the foot, wherein the plantar fascia was modeled as a viscohyperelastic solid. The objective of this work was to develop a fully functional CAD and Finite Element Model of the foot and plantar fascia for analysis by examining the transient stresses on the plantar fascia through the use of a viscohyperelastic material model. The model’s geometry was developed through the use of image processing techniques with anatomical images provided by the National Institutes of Health. The finite element method was used to analyze the transient response …


A Computational Study Of The Kinematics Of Femoroacetabular Morphology During A Sit-To-Stand Transfer, Brandon K. Marine Jan 2017

A Computational Study Of The Kinematics Of Femoroacetabular Morphology During A Sit-To-Stand Transfer, Brandon K. Marine

Theses and Dissertations

Computational modeling in the field of biomechanics is becoming increasingly popular and successful in practice for its ability to predict function and provide information that would otherwise be unobtainable. Through the application of these new and constantly improving methods, kinematics and joint contact characteristics in pathological conditions of femoroacetabular impingement (FAI) and total hip arthroplasty (THA) were studied using a lower extremity computational model. Patients presenting with FAI exhibit abnormal contact between the femoral neck and acetabular rim leading to surrounding tissue damage in daily use. THA is the replacement of both the proximal femur and acetabular region of the …


Nanocomposite Bioelectronics For Biopotential Enabled Prosthesis, Dong Sup Lee Jan 2017

Nanocomposite Bioelectronics For Biopotential Enabled Prosthesis, Dong Sup Lee

Theses and Dissertations

Soft material-enabled electronics can demonstrate extreme mechanical flexibility and stretchability. Such compliant, comfortable electronics allow continuous, long-term measurement of biopotentials on the skin. Manufacturing of the stretchable electronic devices is enabled by the recent development combining materials transfer printing and microfabrication. However, the existing method using inorganic materials and multi-layered polymers requires long material preparation time and expensive processing cost due to the requirement of microfabrication tools and complicated transfer printing steps. Here, this study develops a new fabrication method of soft electronics via a micro-replica-molding technique, which allows fast production, multiple use, and low cost by avoiding microfabrication and …


A 3d Fem Comparative Study On The Impact Response Between Human Head And Nocsae Head Due To Free Fall, Amey S. Badhe Jan 2017

A 3d Fem Comparative Study On The Impact Response Between Human Head And Nocsae Head Due To Free Fall, Amey S. Badhe

Dissertations, Master's Theses and Master's Reports

We all enjoy sports be it watching or playing. Concussion is well known topic when it comes sports related injuries. However, concussion and brain injury is not exclusive to sports and outdoor activities. Sometimes, even the impact due to slip and fall at small heights can cause serious damage to the head and brain. This report studies the response generated in the human head model and the commercially use dummy NOCSAE headform due to drop from height of 2, 3, 4 and 5 feet. Earlier studies have related brain kinetics and head kinematics to concussion and traumatic brain injury (TBI). …


Using Lower Extremity Muscle Activations To Estimate Human Ankle Impedance In The External-Internal Direction, Lauren N. Knop Jan 2017

Using Lower Extremity Muscle Activations To Estimate Human Ankle Impedance In The External-Internal Direction, Lauren N. Knop

Dissertations, Master's Theses and Master's Reports

For millions of people, mobility has been afflicted by lower limb amputation. Lower extremity prostheses have been used to improve the mobility of an amputee; however, they often require additional compensation from other joints and do not allow for natural maneuverability. To improve upon the functionality of ankle-foot prostheses, it is necessary to understand the role of different muscle activations in the modulation of mechanical impedance of a healthy human ankle. This report presents the results of using artificial neural networks (ANN) to determine the functional relationship between lower extremity electromyography (EMG) signals and ankle impedance in the transverse plane. …