Open Access. Powered by Scholars. Published by Universities.®

Biomechanical Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Other Biomedical Engineering and Bioengineering

Institution
Keyword
Publication Year
Publication
Publication Type

Articles 31 - 37 of 37

Full-Text Articles in Biomechanical Engineering

Analysis And Modeling Of The Roles Of Actin-Myosin Interactions In Bladder Smooth Muscle Biomechanics, Seyed Omid Komariza Jan 2014

Analysis And Modeling Of The Roles Of Actin-Myosin Interactions In Bladder Smooth Muscle Biomechanics, Seyed Omid Komariza

Theses and Dissertations

Muscle mechanical behavior potentially plays an important role in some of the most common bladder disorders. These include overactive bladder, which can involve involuntary contractions during bladder filling, and impaired contractility or underactive bladder, which may involve weak or incomplete contractions during voiding. Actin-myosin cross-bridges in detrusor smooth muscle (DSM) are responsible for contracting and emptying the bladder. The total tension produced by muscle is the sum of its preload and active tensions. Studies suggest that actin-myosin cross-links are involved in adjustable preload stiffness (APS), which is characterized by a preload tension curve that can be shifted along the length …


Sequential Structural And Fluid Dynamics Analysis Of Balloon-Expandable Coronary Stents., David Martin Oct 2013

Sequential Structural And Fluid Dynamics Analysis Of Balloon-Expandable Coronary Stents., David Martin

Doctoral

As in-stent restenosis following coronary stent deployment has been strongly linked with stent-induced arterial injury and altered vessel hemodynamics, the sequential numerical analysis of the mechanical and hemodynamic impact of stent deployment within a coronary artery is likely to provide an excellent indication of coronary stent performance. Despite this observation, very few numerical studies have considered both the mechanical and hemodynamic impact of stent deployment. In light of this observation, the aim of this research is to develop a robust numerical methodology for investigating the performance of balloon-expandable coronary stents in terms of their mechanical and hemodynamic impact within a …


Guidance System, Kayaking For The Visually Impaired, D. Ryan Kirtland, Ryan Phife, William Gardner, Amy Johnson Jun 2013

Guidance System, Kayaking For The Visually Impaired, D. Ryan Kirtland, Ryan Phife, William Gardner, Amy Johnson

Biomedical Engineering

Quality Life Plus is working with Team River Runner to develop an assistive guidance system for veterans who want to remain active by kayaking, after sustaining an injury that impairs vision. This system allows these veterans to complete a slalom speed race independent of a personal guide in the water. The system incorporates 3 stations that each contain a speaker connected to a microcontroller system covered by a Pelican Case on a custom made buoy. During the slalom race, a kayaker will travel from shore towards buoy #1 as it omits sound from the speaker. As the kayaker moves around …


Design And Development Of A Stair Ascension Assistive Device For Transfemoral Amputees, Casey Michael Barbarino Jun 2013

Design And Development Of A Stair Ascension Assistive Device For Transfemoral Amputees, Casey Michael Barbarino

Master's Theses

Transfemoral amputees around the world experience increased difficulty in climbing stairs due to lack of muscle, balance, and other factors. The loss of a lower limb greatly diminishes the amount of natural force generation provided that is necessary to propel oneself up stairs. This study investigated possible solutions to the problem of stair ascension for transfemoral amputees by the means of designing and developing an externally attachable device to a prosthesis. The number of amputations from military service has greatly increased since 2008, which shows there is a clear need for assistive devices (Wenke, Krueger, & Ficke, 2012). With the …


Hydraulically Driven Mechanical Representation Of A Biological System, Andrea Argouarch, Michael Mceachern, Brandon Parham Jun 2012

Hydraulically Driven Mechanical Representation Of A Biological System, Andrea Argouarch, Michael Mceachern, Brandon Parham

Biomedical Engineering

No abstract provided.


An Investigation Of Humeral Stress Fractures In Racing Thoroughbreds Using A 3d Finite Element Model In Conjunction With A Bone Remodeling Algorithm, Ryan James Moore Feb 2010

An Investigation Of Humeral Stress Fractures In Racing Thoroughbreds Using A 3d Finite Element Model In Conjunction With A Bone Remodeling Algorithm, Ryan James Moore

Master's Theses

The humerus of a racing horse Thoroughbred is highly susceptible to stress fractures at a characteristic location as a result of cyclic loading. The propensity of a Thoroughbred to exhibit humeral fracture has made equines useful models in the epidemiology of stress fractures. In this study, a racing Thoroughbred humerus was simulated during training using a 3D finite element model in conjunction with a bone remodeling algorithm. Nine muscle forces and two contact forces were applied to the 3-dimensional finite element model, which contains four separate load cases representing fore-stance, mid-stance, aft-stance, and standing. Four different training programs were incorporated …


Mechanical Simulation Of Articular Cartilage Based On Experimental Results, Kevin Matthew Stewart Jun 2009

Mechanical Simulation Of Articular Cartilage Based On Experimental Results, Kevin Matthew Stewart

Master's Theses

Recently, a constituent based cartilage growth finite element model (CGFEM) was developed in order to predict articular cartilage (AC) biomechanical properties before and after growth. Previous research has noted limitations in the CGFEM such as model convergence with growth periods greater than 12 days. The main aims of this work were to address these limitations through (1) implementation of an exact material Jacobian matrix definition using the Jaumann-Kirchhoff (J-K) method and (2) quantification of elastic material parameters based upon research findings of the Cal Poly Cartilage Biomechanics Group (CPGBG). The J-K method was successfully implemented into the CGFEM and exceeded …