Full-Text Articles in Biomechanical Engineering

Ros-Drill Automation: Visual Feedback Control And Rotational Motion Tracking, Jhon F. Diaz Aug 2011

Ros-Drill Automation: Visual Feedback Control And Rotational Motion Tracking, Jhon F. Diaz

Master's Theses

ICSI (intra-cytoplasmic sperm injection) has attracted research interest from both biological and engineering groups. The technology is constantly evolving to perform this procedure with precision and speed. One such development is the contribution of this thesis. We focus on a relatively recent procedure called Ros-Drill© (rotationally oscillating drill), of which the early versions have already been effectively utilized for the mice. In the first part, we present a procedure to automate a critical part of the operation: initiation of the rotational oscillation, Visual feedback is used to track the pipette tip. Predetermined species-specific penetration depth is successfully utilized …


Gas Embolic Factors In Cardiovascular Health, Eric L. Cutler Apr 2011

Gas Embolic Factors In Cardiovascular Health, Eric L. Cutler

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Gas emboli are a clinical issue often encountered in the space exploration, marine construction, and medical fields.  Individuals involved with these disciplines will often have asympomatic gas emboli circulating throughout their bodies on a regular basis.  A study into the impact of chronic asymptomatic gas emboli on the risk of atherosclerosis in humans is thus presented.  This research utilized a custom built cardiovascular flow simulator and accompanying data acquisition system to experimentally determine the influence of gas emboli under varied circumstances on the mean wall shear stress of a tube in-vitro.  A directly inverse relationship between gas embolus presence in …


Characterising 3d Soft Tissue Features On Joint Surfaces, Colm O'Kane Jan 2011

Characterising 3d Soft Tissue Features On Joint Surfaces, Colm O'Kane

Conference Papers

A crucial aspect of orthopaedic implant design is the prediction of surgical outcomes when the shape of a bone is necessarily altered by the addition of the implant. Matching native kinematics as closely as possible is generally considered a core aim of joint replacement surgery. The overall hypothesis behind this research is that soft tissue geometry, including cartilage thickness distribution and ligament attachment sites, influences kinematics in the knee joint. In order to enable investigation of possible links between geometry and kinematics, the ability to characterise the shape variation of the soft tissue relative to the underlying bony geometry must …


Estimation Of The Centre Of Mass From Motion Capture And Force Plate Recordings: A Study On The Elderly, Sebastien Cotton, Michele Vanoncini, Philippe Fraisse, Nacim Ramdani, Emel Demircan, Andrew P. Murray, Thierry Keller Jan 2011

Estimation Of The Centre Of Mass From Motion Capture And Force Plate Recordings: A Study On The Elderly, Sebastien Cotton, Michele Vanoncini, Philippe Fraisse, Nacim Ramdani, Emel Demircan, Andrew P. Murray, Thierry Keller

Mechanical and Aerospace Engineering Faculty Publications

The estimation of the centre of mass position in humans is usually based on biomechanical models developed from anthropometric tables. This method can potentially introduce errors in studies involving elderly people, since the ageing process is typically associated with a modification of the distribution of the body mass. In this paper, an alternative technique is proposed, and evaluated with an experimental study on 9 elderly volunteers. The technique is based on a virtual chain, identified from experimental data and locating the subject's centre of mass. Its configuration defines the location of the centre of mass, and is a function of …


Using Thermally Coupled Reactive Distillation Columns In Biodiesel Production, Nghi Nguyen, Yaşar Demirel Jan 2011

Using Thermally Coupled Reactive Distillation Columns In Biodiesel Production, Nghi Nguyen, Yaşar Demirel

Yaşar Demirel Publications

Production of ethyl dodecanoate (biodiesel) using lauric acid and methanol with a solid acid catalyst of sulfated zirconia is studied by using two distillation sequences. In the first sequence, the methanol recovery column follows the reactive distillation column. In the second sequence, the reactive distillation and methanol recovery columns are thermally coupled. Thermally coupled distillation sequences may consume less energy by allowing interconnecting vapor and liquid streams between the two columns to elminate reboiler or condenser or both. Here we study the thermally coupled side-stripper reactive distillation and eliminate the condenser of the reactive distillation column. Both the sequences are …


Personal Navigation Via High-Resolution Gait-Corrected Inertial Measurement Units, Özkan Bebek, Michael A. Suster, Srihari Rajgopal, Michael J. Fu, Xuemei Huang, M. Cenk Çavu¸So˘Glu,, Darrin J. Young, Mehran Mehregany, Antonie J. Van Den Bogert, Carlos H. Mastrangelo Nov 2010

Personal Navigation Via High-Resolution Gait-Corrected Inertial Measurement Units, Özkan Bebek, Michael A. Suster, Srihari Rajgopal, Michael J. Fu, Xuemei Huang, M. Cenk Çavu¸So˘Glu,, Darrin J. Young, Mehran Mehregany, Antonie J. Van Den Bogert, Carlos H. Mastrangelo

Mechanical Engineering Faculty Publications

In this paper, a personal micronavigation system that uses high-resolution gait-corrected inertial measurement units is presented. The goal of this paper is to develop a navigation system that uses secondary inertial variables, such as velocity, to enable long-term precise navigation in the absence of Global Positioning System (GPS) and beacon signals. In this scheme, measured zerovelocity duration from the ground reaction sensors is used to reset the accumulated integration errors from accelerometers and gyroscopes in position calculation. With the described system, an average position error of 4 m is achieved at the end of half-hour walks.


Material Modeling And Analysis For The Development Of A Realistic Blast Headform, S. G. M. Hossain Aug 2010

Material Modeling And Analysis For The Development Of A Realistic Blast Headform, S. G. M. Hossain

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Blast traumatic brain injury (BTBI) has become an important topic of study because of the increase of such incidents, especially due to the recent growth of improvised explosive devices (IEDs). This thesis discusses a project in which laboratory testing of BTBI was made possible by performing blast loading on experimental models simulating the human head. Three versions of experimental models were prepared – one having a simple geometry and the other two having geometry similar to a human head. For developing the head models, three important parts of the head were considered for material modeling and analysis – the skin, …


Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jun 2010

Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. Following a laryngectomy, some people speak using an electrolarynx which replaces the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the buzzing monotonic sound emitted, the need for a free hand to operate the device, and difficulty experienced by many laryngectomees in adapting to its use. Despite these shortcomings, it remains the preferred method of speech rehabilitation for a substantial minority of laryngectomees. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal …


An Investigation Of Humeral Stress Fractures In Racing Thoroughbreds Using A 3d Finite Element Model In Conjunction With A Bone Remodeling Algorithm, Ryan James Moore Feb 2010

An Investigation Of Humeral Stress Fractures In Racing Thoroughbreds Using A 3d Finite Element Model In Conjunction With A Bone Remodeling Algorithm, Ryan James Moore

Master's Theses

The humerus of a racing horse Thoroughbred is highly susceptible to stress fractures at a characteristic location as a result of cyclic loading. The propensity of a Thoroughbred to exhibit humeral fracture has made equines useful models in the epidemiology of stress fractures. In this study, a racing Thoroughbred humerus was simulated during training using a 3D finite element model in conjunction with a bone remodeling algorithm. Nine muscle forces and two contact forces were applied to the 3-dimensional finite element model, which contains four separate load cases representing fore-stance, mid-stance, aft-stance, and standing. Four different training programs were incorporated …


An Analytical Model For Rotator Cuff Repairs, A. Aurora, Jorge E. Gatica, Antonie J. Van Den Bogert, J. A. Mccarron, Kathleen A. Derwin Jan 2010

An Analytical Model For Rotator Cuff Repairs, A. Aurora, Jorge E. Gatica, Antonie J. Van Den Bogert, J. A. Mccarron, Kathleen A. Derwin

Mechanical Engineering Faculty Publications

Background

Currently, natural and synthetic scaffolds are being explored as augmentation devices for rotator cuff repair. When used in this manner, these devices are believed to offer some degree of load sharing; however, no studies have quantified this effect. Furthermore, the manner in which loads on an augmented rotator cuff repair are distributed among the various components of the repair is not known, nor is the relative biomechanical importance of each component. The objectives of this study are to (1) develop quasi-static analytical models of simplified rotator cuff repairs, (2) validate the models, and (3) predict the degree of load …


Mechanical Simulation Of Articular Cartilage Based On Experimental Results, Kevin Matthew Stewart Jun 2009

Mechanical Simulation Of Articular Cartilage Based On Experimental Results, Kevin Matthew Stewart

Master's Theses

Recently, a constituent based cartilage growth finite element model (CGFEM) was developed in order to predict articular cartilage (AC) biomechanical properties before and after growth. Previous research has noted limitations in the CGFEM such as model convergence with growth periods greater than 12 days. The main aims of this work were to address these limitations through (1) implementation of an exact material Jacobian matrix definition using the Jaumann-Kirchhoff (J-K) method and (2) quantification of elastic material parameters based upon research findings of the Cal Poly Cartilage Biomechanics Group (CPGBG). The J-K method was successfully implemented into the CGFEM and exceeded …


A Real-Time, 3-D Musculoskeletal Model For Dynamic Simulation Of Arm Movements, Edward K. Chadwick, Dimitra Blana, Antonie J. Van Den Bogert, Robert F. Kirsch Apr 2009

A Real-Time, 3-D Musculoskeletal Model For Dynamic Simulation Of Arm Movements, Edward K. Chadwick, Dimitra Blana, Antonie J. Van Den Bogert, Robert F. Kirsch

Mechanical Engineering Faculty Publications

Neuroprostheses can be used to restore movement of the upper limb in individuals with high-level spinal cord injury. Development and evaluation of command and control schemes for such devices typically require real-time, ldquopatient-in-the-looprdquo experimentation. A real-time, 3-D, musculoskeletal model of the upper limb has been developed for use in a simulation environment to allow such testing to be carried out noninvasively. The model provides real-time feedback of human arm dynamics that can be displayed to the user in a virtual reality environment. The model has a 3-DOF glenohumeral joint as well as elbow flexion/extension and pronation/supination and contains 22 muscles …


Design And Characterization Of A Shock And Vibration Mitigation Seat System, George Samaan Ladkany Jan 2009

Design And Characterization Of A Shock And Vibration Mitigation Seat System, George Samaan Ladkany

UNLV Theses, Dissertations, Professional Papers, and Capstones

Extensive research has been conducted into the development of pneumatic seatbladder systems for shock and vibration mitigation for use in current U.S military vehicle envelopes. This research expands on the previous work through an elaborate experimental characterization of four prototype air bladder seat cushion systems. The experimental characterization conducted included shock testing, continuous vibration, and internal dynamic pressure measured during the shock event.

The shock testing was conducted both at the Army Research Lab as well at UNLV. The shock testing conducted at UNLV was performed on a drop tower designed and constructed during the time of this research. The …


An Analysis Of The Performance Of Foams Used In Hurling Helmets, Keith Norris, Stephen Tiernan May 2008

An Analysis Of The Performance Of Foams Used In Hurling Helmets, Keith Norris, Stephen Tiernan

Conference Papers

Abstract Head injuries can occur in most sporting activities. The seriousness of these injuries can vary greatly depending on the sport. Many sports such as American football, cricket, baseball and hurling try to reduce this risk by designing helmets that are suitable to be worn by the players. The National Standard Authority of Ireland (NSAI) has recently made great strides in this area with the introduction of the first comprehensive standard adopted for the sport I.S. 355:2006, which sets out new testing procedures that all new helmets must meet. The Gaelic Athletic Association (GAA) has also stated its intention to …


Lower Extremity Mechanics During Cutting Tasks In Different Shoe-Turf Combinations, Rafael Garcilazo Apr 2007

Lower Extremity Mechanics During Cutting Tasks In Different Shoe-Turf Combinations, Rafael Garcilazo

McNair Scholars Research Journal

The demands placed on the lower extremity when performing jumping and cutting maneuvers are depending, in part, on the interaction between the playing surface and the athlete's footwear. Higher demands are likely to result in increased incidence of injury, so for safety reasons it is important to quantify how the shoe-turf interface affects joint loads. The purpose of this study is to compare the forces on the lower extremity while landing and side cutting (rapid direction change at approximately 45 degrees) on artificial football turf with different styles of football cleats.


Distal Placement Of An End-To-Side Bypass Graft Anastomosis A 3-D Computational Study, John Robert Di Cicco Oct 2004

Distal Placement Of An End-To-Side Bypass Graft Anastomosis A 3-D Computational Study, John Robert Di Cicco

Mechanical & Aerospace Engineering Theses & Dissertations

A three-dimensional computational fluid dynamics study of blood flow through stenotic arteries has been conducted. Flow phenomena, such as separation regions and turbulence, can be found distal to an arterial stenosis. Frequently, a bypass graft using an end-to-side technique is attached to a stenotic artery to restore adequate blood flow. However, a significant percentage of these grafts fail after thirty postoperative days due to intimal hyperplasia development around the distal anastomosis. Moreover, aberrant wall shear rates have been implicated as a factor in the development of intimal hyperplasia. Thus, the present study examines whether placement of the distal end of …


Comment On "Quadriceps Protects The Anterior Cruciate Ligament", Antonie J. Van Den Bogert Sep 2002

Comment On "Quadriceps Protects The Anterior Cruciate Ligament", Antonie J. Van Den Bogert

Mechanical Engineering Faculty Publications

No abstract provided.


Investigation Of Blood Pressure Measurement Using A Hydraulic Occlusive Cuff, Kusha R. Bhattarai May 1982

Investigation Of Blood Pressure Measurement Using A Hydraulic Occlusive Cuff, Kusha R. Bhattarai

Dissertations and Theses

This thesis presents an improved oscillotonometric system for the measurement of human blood pressure. The study included:

1. The design of a hydraulic occlusive cuff,

2. The investigation of the wave forms taken from the blood pressure measurements, and

3. The design of a mechanism for the simulation of human blood pressure pulse.

In this study, an experimental system consisting of a rigid shell occlusive cuff, a constant volume displacement pump, a transducer, and a chart recorder was designed and used for data collection.