Articles 61 - 90 of 283
Full-Text Articles in Mechanical Engineering
Impact Of Residential Mechanical Ventilation On Energy Cost And Humidity Control, Florida Solar Energy Center, Eric Martin
Impact Of Residential Mechanical Ventilation On Energy Cost And Humidity Control, Florida Solar Energy Center, Eric Martin
FSEC Energy Research Center®
The DOE Building America program has been conducting research leading to cost effective high performance homes since the early 1990's. Optimizing whole house mechanical ventilation as part of the program's systems engineered approach to constructing housing has been an important subject of the program's research. Ventilation in residential buildings is one component of an effective, comprehensive strategy for creation and maintenance of a comfortable and healthy indoor air environment. The study described in this white paper is based on building energy modeling with an important focus on the indoor humidity impacts of ventilation. The modeling tools used were EnergyPlus version …
Flexible Residential Test Facility: Impact Of Infiltration And Ventilation On Measured Heating Season Energy And Moisture Levels, Florida Solar Energy Center, Danny Parker
Flexible Residential Test Facility: Impact Of Infiltration And Ventilation On Measured Heating Season Energy And Moisture Levels, Florida Solar Energy Center, Danny Parker
FSEC Energy Research Center®
Perhaps no residential topic has been discussed as much among building scientists as air infiltration and required mechanical ventilation. Usually, envelope tightening is recommended as an efficiency strategy for retrofitting an existing home. In humid climates, reducing infiltration can reduce summer moisture loads. However, during drier weather when the air conditioner is not running, lower infiltration can lead to potential condensation. Even though severe cold weather is rare in the Deep South, the prevalence of single-pane windows can lead to condensation events.
Energy And Economic Optimization To Achieve Near Zero Energy Homes In Europe: Implications Of Inclusion Of Lighting And Appliances, Florida Solar Energy Center, Danny Parker
Energy And Economic Optimization To Achieve Near Zero Energy Homes In Europe: Implications Of Inclusion Of Lighting And Appliances, Florida Solar Energy Center, Danny Parker
FSEC Energy Research Center®
Achieving annual net zero energy use in homes has been demonstrated as feasible in dozens of monitored projects in the United States.[1] In particular, very low energy use homes in Europe have been proven within the Passivhaus approach.[2] Achieving 'nearly zero energy buildings' (NZEB) has also been established as a vital objective over the next decade within the European Union (EU) (Boermans et al., 2011). However, reaching this result at the lowest possible cost remains a key challenge around the world. Balancing renewable power generation with energy efficiency will be vital in Europe as anticipated by Voss, Musall and Lichtmeß.[4] …
Technical Subtopic 2.1: Modeling Variable Refrigerant Flow Heat Pump And Heat Recovery Equipment In Energyplus, Florida Solar Energy Center, Richard Raustad
Technical Subtopic 2.1: Modeling Variable Refrigerant Flow Heat Pump And Heat Recovery Equipment In Energyplus, Florida Solar Energy Center, Richard Raustad
FSEC Energy Research Center®
The University of Central Florida/Florida Solar Energy Center, in cooperation with the Electric Power Research Institute and several variable-refrigerant-flow air conditioning (VRF AC) manufacturers, provided a detailed computer model for a VRF AC system in the United States Department of Energy's (U.S. DOE) EnergyPlus' building energy simulation tool. No other simulation tool currently has the capability to accurately model this state-of-the-art VRF heating, ventilating, and air conditioning (HVAC) equipment. Detailed laboratory testing and field demonstrations were performed to measure equipment performance and compare this performance with that predicted by the use of this new model through computer simulation.
This project …
Current Best Practices For High Performance, Deep Energy Retrofits In Florida Affordable Housing, Florida Solar Energy Center, Janet Mcilvaine
Current Best Practices For High Performance, Deep Energy Retrofits In Florida Affordable Housing, Florida Solar Energy Center, Janet Mcilvaine
FSEC Energy Research Center®
In the fall of 2009, researchers at the Florida Solar Energy Center (FSEC) began working with affordable housing entities that were conducting major renovation projects in unoccupied, foreclosed homes. The study was funded by the Florida Energy Systems Consortium and the U.S. Department of Energy's Building America program. When components and equipment were being replaced because they were worn out, researchers provided savings projections for higher-efficiency choices. Savings were also projected for improvements that were strictly for energy efficiency, such as adding ceiling insulation. The best practices summarized in this document are a mixture of assessment, design, specification, quality assurance, …
Hers Index Scores As An Alternative Compliance Path For The 2015 Iecc, Florida Solar Energy Center, Philip W. Fairey
Hers Index Scores As An Alternative Compliance Path For The 2015 Iecc, Florida Solar Energy Center, Philip W. Fairey
FSEC Energy Research Center®
The analysis presented here is an extension of a previous study on HERS Index Scores as they relate to various version of the International Energy Conservation Code (IECC) by the same author. This extension of the previous study is designed to examine the impact of advanced, ultra-high efficiency appliances and high efficiency HVAC systems on HERS Index Scores as they relate to reductions in the HERS Index Scores that may be used as 'tradeoffs' against best practice envelope efficiencies.
The Next Step Toward Widespread Residential Deep Energy Retrofits, Florida Solar Energy Center, Janet Mcilvaine
The Next Step Toward Widespread Residential Deep Energy Retrofits, Florida Solar Energy Center, Janet Mcilvaine
FSEC Energy Research Center®
The Building America Partnership for Improved Residential Construction (BA-PIRC) has been working with affordable housing entities to identify cost-effective technical pathways to achieve energy savings levels of 30% and safeguard or enhance indoor air quality (IAQ), durability, and comfort (McIlvaine et al. 2012; Fairey and Parker 2012).
Determining Appropriate Heating And Cooling Thermostat Set Points For Building Energy Simulations For Residential Buildings In North America, Florida Solar Energy Center, Danny Parker
Determining Appropriate Heating And Cooling Thermostat Set Points For Building Energy Simulations For Residential Buildings In North America, Florida Solar Energy Center, Danny Parker
FSEC Energy Research Center®
Existing building energy simulation tools have a purported tendency to over-predict heating use and, in some cases, to under-predict cooling use, an outcome often attributed to inappropriate assumptions about thermostat management. As a result, a systematic review was conducted for the purposes of determining typical heating and cooling set points for single-family houses in North America. The preliminary consensus results provide an empirical basis for establishing typical inputs for building energy simulation models, increasing prediction accuracy of heating and cooling loads. The results of this review have been applied as default values in the Lawrence Berkeley National Laboratory's Home Energy …
Energy Retrofit Field Study And Best Practices In A Hot-Humid Climate, Florida Solar Energy Center, Janet Mcilvaine
Energy Retrofit Field Study And Best Practices In A Hot-Humid Climate, Florida Solar Energy Center, Janet Mcilvaine
FSEC Energy Research Center®
In the U.S. Census Bureau's Southern region, housing starts ranged from 4.6 to 5.9 million per decade from the 1970s through the 2000s, nearly twice as many as any other region across all decades. The potential for energy savings in these homes is vast, perhaps our most available untapped resource for reducing energy needs. This study was conducted in central Florida, which forms part of the Census Bureau's Southern region. It examines efficiency retrofit opportunities, typical renovation practices, and pathways for achieving U.S. Department of Energy (DOE) goals for existing homes in that region.
Analysis Of Hers Index Scores For Recent Versions Of The International Energy Conservation Code (Iecc) [Revised], Florida Solar Energy Center, Philip W. Fairey
Analysis Of Hers Index Scores For Recent Versions Of The International Energy Conservation Code (Iecc) [Revised], Florida Solar Energy Center, Philip W. Fairey
FSEC Energy Research Center®
The EnergyGauge HERS software tool was used to examine the IECC Standard Reference Design (IECC SRD) configuration for one-story 2000 ft2 and two-story 2,400 ft2 single-family homes in sixteen representative U.S. cities. IECC SRD homes were configured for the 2006 IECC, the 2009 IECC and the 2012 IECC. Two additional set of analysis were conducted, both using the 2012 IECC SRD with enhanced equipment: 1) with equipment configured to meet the 2015 National Appliance Energy Conservation Act (NAECA) equipment requirements and 2) with equipment that is on the cusp of significant market penetration with efficiencies greater than the 2015 standard.HERS …
Measured Cooling Performance And Potential For Buried Duct Condensation In A 1991 Central Florida Retrofit Home, Florida Solar Energy Center, Dave Chasar
Measured Cooling Performance And Potential For Buried Duct Condensation In A 1991 Central Florida Retrofit Home, Florida Solar Energy Center, Dave Chasar
FSEC Energy Research Center®
The Florida Solar Energy Center (FSEC) conducted energy performance monitoring of two existing residences in Central Florida that were undergoing various retrofits. These homes were occupied by FSEC researchers and were fully instrumented to yield detailed energy, temperature, and humidity measurements. The data gave feedback about the performance of two levels of retrofit in two types of homes in a hot-humid climate. This report covers a moderate-level retrofit and includes 2 years of pre-retrofit data to characterize the impact of improvements. The other home, covered in a separate report (Parker and Sherwin 2012), is a deep energy retrofit that has …
Cost Effectiveness Of Home Energy Retrofits In Pre-Code Vintage Homes In The United States, Florida Solar Energy Center, Philip W. Fairey
Cost Effectiveness Of Home Energy Retrofits In Pre-Code Vintage Homes In The United States, Florida Solar Energy Center, Philip W. Fairey
FSEC Energy Research Center®
This study investigates the cost effectiveness of a large number of potential home energy retrofit measures using pre-code home archetypes that can be considered typical in a range of climates throughout the United States.
Managing The Drivers Of Airflow And Water Vapor Transport In Existing Single-Family Homes (Revised), Florida Solar Energy Center, James Cummings
Managing The Drivers Of Airflow And Water Vapor Transport In Existing Single-Family Homes (Revised), Florida Solar Energy Center, James Cummings
FSEC Energy Research Center®
Air and water vapor are transported into and within single-family homes as a result of pathways and driving forces. Without pathways, no air or water vapor transport could occur. Likewise, without driving forces, little or no air or water vapor transport will occur. Homes always have pathways and driving forces. This report focuses on managing the driving forces that move air and water vapor across the building envelope.
A Comparison Of Homes Built To The 2009 And 1984 Florida Energy Codes, Florida Solar Energy Center, Charles Withers, Jr.
A Comparison Of Homes Built To The 2009 And 1984 Florida Energy Codes, Florida Solar Energy Center, Charles Withers, Jr.
FSEC Energy Research Center®
The Florida Solar Energy Center conducted research into the effectiveness of the Florida energy code to reduce energy use in residential buildings. FSEC examined two groups of homes: those built to the 1984 energy code (June 1,1984-1985) and those built to the 2007 with 2009 supplement energy code (March 1, 2009-2010). This report discusses data collection methods, analysis and results that focus on comparisons of measured energy use and house characteristics between both code periods.
Accuracy Of The Home Energy Saver Energy Calculation Methodology, Florida Solar Energy Center, Danny Parker
Accuracy Of The Home Energy Saver Energy Calculation Methodology, Florida Solar Energy Center, Danny Parker
FSEC Energy Research Center®
The Home Energy Saver (HES) suite offers popular online simulation tools that enable U.S. homeowners and energy professionals to rigorously evaluate home energy use and develop recommendations on how energy can be saved across all end uses. The underlying analytical system is also available as a web service to power third-party energy analysis tools. Given the system's diverse uses, it is important that the simulation is robust and intrinsically accurate. While the engineering methods and assumptions are extensively documented and subjected to peer review, it is useful to evaluate how well HES predicts energy use in occupied homes. In this …
Final Technical Report (2nd Revision) Arra: Florida Energy Code Compliance Train-The-Trainer Program, Florida Solar Energy Center, Jeffrey Sonne
Final Technical Report (2nd Revision) Arra: Florida Energy Code Compliance Train-The-Trainer Program, Florida Solar Energy Center, Jeffrey Sonne
FSEC Energy Research Center®
A multi-faceted Florida Energy Code compliance methods, tools and field verification training program was established that included development of two instructor-led and two web-based courses, instructor training and course development support, and training of building officials and contractors throughout the state.
Separate instructor-led commercial and residential 2010 Florida Energy Code compliance courses were developed for train-the-trainer class use, and existing instructor-led blueprints data collection and energy code software courses were redeveloped as web-based courses.
Through partnerships with Florida colleges, building departments and industry organizations, a total of 42 instructors were trained to provide commercial energy code compliance training and 42 …
Final Report Of Task Eight: Arra Energy Code Compliance Project, Florida Solar Energy Center, Charles Withers, Jr.
Final Report Of Task Eight: Arra Energy Code Compliance Project, Florida Solar Energy Center, Charles Withers, Jr.
FSEC Energy Research Center®
This report summarizes the Florida energy code compliance project for both residential and commercial activities and shows results in accomplishing the Florida Energy Code compliance objectives to develop and conduct an energy code enforcement study. Work is discussed regarding efforts to find and conduct Florida Energy Code enforcement practice evaluations in residential and commercial buildings built after the March 1, 2009 code period.
Partnership For High Performance Housing Final Report, Florida Solar Energy Center, Janet Mcilvaine
Partnership For High Performance Housing Final Report, Florida Solar Energy Center, Janet Mcilvaine
FSEC Energy Research Center®
This report describes research conducted by the Florida Solar Energy Center (FSEC) under funding from the Pacific Northwest National Laboratory. This work falls under the umbrella of the U.S. Department of Energy's Building America program. High performance goals were set for renovation of existing housing and construction of new affordable housing. Both efforts included monitoring the energy use of several homes.
Achieving Very High Efficiency And Net Zero Energy In An Existing Home In A Hot-Humid Climate: Long-Term Utility And Monitoring Data, Florida Solar Energy Center, Danny Parker
Achieving Very High Efficiency And Net Zero Energy In An Existing Home In A Hot-Humid Climate: Long-Term Utility And Monitoring Data, Florida Solar Energy Center, Danny Parker
FSEC Energy Research Center®
This study summarizes the first six months of detailed data collected about a single-family home that experienced a series of retrofits targeting reductions in energy use. The project was designed to develop data about how envelope modifications in heating, ventilation, and air conditioning and domestic hot water and renewable measures can result in considerable energy reductions and potentially net zero energy for an existing home. Using utility billing records and recent detailed monitoring data, this study was also able to chronicle the progress of energy reduction over a 22-year period.
Energy Savings And Peak Demand Reduction Of A Seer 21 Heat Pump Vs. A Seer 13 Heat Pump With Attic And Indoor Duct Systems - December 2011, Florida Solar Energy Center, James Cummings
Energy Savings And Peak Demand Reduction Of A Seer 21 Heat Pump Vs. A Seer 13 Heat Pump With Attic And Indoor Duct Systems - December 2011, Florida Solar Energy Center, James Cummings
FSEC Energy Research Center®
Experiments were run in an unoccupied 1600 ft2 house, the Manufactured Housing (MH Lab) at the Florida Solar Energy Center (FSEC), to evaluate the delivered performance as well as the relative performance of a SEER 21 variable capacity heat pump versus a SEER 13 heat pump. The performance was evaluated with two different duct systems: a standard attic duct system and an indoor duct system located in a dropped-ceiling space.
Building America Industrialized Housing Partnership (Baihp Ii) Final Report Budget Periods 1-5, April 1, 2006 - November 30, 2010, Florida Solar Energy Center, Robert Abernethy
Building America Industrialized Housing Partnership (Baihp Ii) Final Report Budget Periods 1-5, April 1, 2006 - November 30, 2010, Florida Solar Energy Center, Robert Abernethy
FSEC Energy Research Center®
This report summarizes the work conducted by the Building America Industrialized Housing Partnership (BAIHP - www.baihp.org) during the final budget period (BP5) of our contract, January 1, 2010 to November 30, 2010. Highlights from the four previous budget periods are included for context.
BAIHP is led by the Florida Solar Energy Center (FSEC) of the University of Central Florida. With over 50 Industry Partners including factory and site builders, work in BP5 was performed in six tasks areas:
- Task 1: Building America System Research Management, Documentation and Technical Support
- Task 2A: Stage G1A: Integrated Solutions for Specific Climate Regions
- Task …
Short-Term Curtailment Of Hvac Loads - Executive Summary, Florida Solar Energy Center, Lixing Gu
Short-Term Curtailment Of Hvac Loads - Executive Summary, Florida Solar Energy Center, Lixing Gu
FSEC Energy Research Center®
Rapidly increasing requirements placed on utilities to reduce peak loads has led to utility customer incentives to shift peak demand to non-peak times or reduce peak loads when notified by the utility that the grid is close to capacity. This study investigates methods used to reduce building demand during a fixed time window near a utilities on-peak period. The window was chosen to be 5-9 A.M. in winter and 2-5 P.M. in summer. The most common methods for reducing building peak demand were reviewed and categorized by their usefulness and wide-spread availability. These strategies were reductions in lighting power density, …
Performance Of Four Near Zero Energy Homes: Lessons Learned, Florida Solar Energy Center, Carlos Colon
Performance Of Four Near Zero Energy Homes: Lessons Learned, Florida Solar Energy Center, Carlos Colon
FSEC Energy Research Center®
While the idea of a zero or near zero energy home is well understood, the actual performance of the structure can be different than expected. High performance homes necessitate increasingly complex envelope, HVAC, water heating, and appliance systems, and successful designs rely on proper function and feedback from those systems to achieve low-energy goals. This paper presents measured data on four near zero energy homes located in Florida that are a part of the U.S. DOE Building America program. The monitored data are compared to both a benchmark model and the prototype computer simulations. By examining the submetered energy data, …
Building America Industrialized Housing Partnership Case Studies - 2010, Florida Solar Energy Center, Janet Mcilvaine
Building America Industrialized Housing Partnership Case Studies - 2010, Florida Solar Energy Center, Janet Mcilvaine
FSEC Energy Research Center®
This document is a compilation of 14 separate case studies of home builders who have adopted Building America principles of high performance as standard construction. This work was compiled by the Building America Industrialized Housing Partnership (www.baihp.org ) for the U.S. Department of Energy to serve as a model for other housing providers. BAIHP is led by the Florida Solar Energy Center of the University of Central Florida.
Florida Weatherization Training - Quarterly Report (July 2010 - September 2010), Florida Solar Energy Center, Neil Moyer
Florida Weatherization Training - Quarterly Report (July 2010 - September 2010), Florida Solar Energy Center, Neil Moyer
FSEC Energy Research Center®
The weatherization training for the State of Florida Dept of Community Affairs continues at the Florida Solar Energy Center's Training Facility. Progress for the fifth three months of the contract included minor course refinement of presentation materials and handouts as the result of the June 2010 updates to the P & G . Four 1-day IR classes were completed (45 students).
Opportunities For Energy Conservation And Improved Comfort From Wind Washing Retrofits In Two-Story Homes - Part Ii, Florida Solar Energy Center, Charles Withers, Jr.
Opportunities For Energy Conservation And Improved Comfort From Wind Washing Retrofits In Two-Story Homes - Part Ii, Florida Solar Energy Center, Charles Withers, Jr.
FSEC Energy Research Center®
Wind washing is a general term referring to diminished thermal control caused by air movement partially or completely bypassing the thermal barrier. The primary focus of this paper relates to a specific type of wind washing where wind can push attic air into the floor cavity between first and second stories of the home through ineffective (or missing) air barriers separating attic space from the floor cavity. A second type of wind washing studied in this project involves insulation batts on knee walls where space between the batts and the wall board allow air movement against the gypsum wall board. …
Opportunities For Energy Conservation And Improved Comfort From Wind Washing Retrofits In Two-Story Homes - Part I, Florida Solar Energy Center, Charles Withers, Jr.
Opportunities For Energy Conservation And Improved Comfort From Wind Washing Retrofits In Two-Story Homes - Part I, Florida Solar Energy Center, Charles Withers, Jr.
FSEC Energy Research Center®
Wind washing is a general term referring to diminished thermal control caused by air movement over or through a thermal barrier. The primary focus of this paper is towards a specific type of wind washing where wind can push attic air into the floor cavity between first and second stories of the home through ineffective (or missing) air barriers separating attic space from the floor cavity. A second type of wind washing studied in this project involved insulation batts on knee walls where space between the batts and the wall board allowed air movement against the gypsum wall board. During …
Affiliate Steps Toward Building Energy Star Homes, Florida Solar Energy Center, Janet Mcilvaine
Affiliate Steps Toward Building Energy Star Homes, Florida Solar Energy Center, Janet Mcilvaine
FSEC Energy Research Center®
To certify a home as an Energy Star, a builder works with a RESNET certified home energy rater to evaluate the home with respect to criteria required by the Energy Star program. The following steps will help Habitat affiliates navigate the path toward building Energy Star homes.
Pilot Evaluation Of Energy Savings And Persistence From Residential Energy Demand Feedback Devices In A Hot Climate, Florida Solar Energy Center, Danny Parker
Pilot Evaluation Of Energy Savings And Persistence From Residential Energy Demand Feedback Devices In A Hot Climate, Florida Solar Energy Center, Danny Parker
FSEC Energy Research Center®
According to past studies, providing instantaneous feedback on household electrical demand has shown the promise to typically reduce energy consumption by 5-10%. This paper briefly reviews past research and describes a two year pilot evaluation of a low cost residential energy feedback system installed in twenty case study homes in Florida. Although not a statistical sample (the participants were self-selected and interested in reducing energy use), the study showed an average 7% reduction in energy use from feedback homes in the second year of monitoring after controlling for weather-related influences. However, a follow-up evaluation done three years later found little …
Exploring Cost-Effective, High Performance Residential Retrofits For Affordable Housing In The Hot Humid Climate, Florida Solar Energy Center, Janet Mcilvaine
Exploring Cost-Effective, High Performance Residential Retrofits For Affordable Housing In The Hot Humid Climate, Florida Solar Energy Center, Janet Mcilvaine
FSEC Energy Research Center®
In 2009, a Department of Energy Building America team led by the Florida Solar Energy Center began working with partners to find cost-effective paths for improving the energy performance of existing homes in the hot humid climate. A test-in energy audit and energy use modeling of the partner's proposed renovation package was performed for 41 affordable and middle income foreclosed homes in Florida and Alabama. HERS1 Indices ranged from 92 to 184 with modeled energy savings ranging from 3% to 50% (average of 26%). Analyses and recommendations were discussed with partners to encourage more efficient retrofits, highlight health and safety …