Open Access. Powered by Scholars. Published by Universities.®
Other Materials Science and Engineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Metallurgy (17)
- Polymer and Organic Materials (14)
- Structural Materials (11)
- Ceramic Materials (7)
- Semiconductor and Optical Materials (7)
-
- Engineering Science and Materials (5)
- Mechanical Engineering (5)
- Physical Sciences and Mathematics (4)
- Aerospace Engineering (3)
- Biomaterials (3)
- Biomedical Engineering and Bioengineering (3)
- Chemistry (3)
- Mechanics of Materials (3)
- Nanoscience and Nanotechnology (3)
- Polymer Chemistry (3)
- Biology and Biomimetic Materials (2)
- Chemical Engineering (2)
- Computer-Aided Engineering and Design (2)
- Electrical and Computer Engineering (2)
- Life Sciences (2)
- Other Engineering (2)
- Other Engineering Science and Materials (2)
- Risk Analysis (2)
- Structures and Materials (2)
- Acoustics, Dynamics, and Controls (1)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (1)
- Applied Mechanics (1)
- Keyword
-
- Materials Engineering (19)
- Materials engineering (8)
- Corrosion (6)
- Aluminum (4)
- Composites (4)
-
- Composite (3)
- Mechanical Properties (3)
- Quantum Dots (3)
- Acoustics (2)
- Bamboo (2)
- Carbon Fiber (2)
- Delamination (2)
- Elastomer (2)
- Galvanic Corrosion (2)
- Laminates (2)
- Life cycle assessment (2)
- Mudslide (2)
- Nanoparticles (2)
- Nanotechnology (2)
- Organic (2)
- Photovoltaic (2)
- SEM (2)
- Solar (2)
- Stainless steel (2)
- Toxicity (2)
- Viscosity (2)
- 2050 (1)
- 2195 (1)
- 3D printed metal (1)
- 7075 (1)
Articles 61 - 77 of 77
Full-Text Articles in Other Materials Science and Engineering
An Exploratory Investigation Into How Cold Working Can Affect The Acoustic Performance Of Thin Aluminum Foil In A Ribbon Microphone, Alexander (Alex) Stanley
An Exploratory Investigation Into How Cold Working Can Affect The Acoustic Performance Of Thin Aluminum Foil In A Ribbon Microphone, Alexander (Alex) Stanley
Materials Engineering
Ribbons of 4 μm thin 99.1% pure aluminum foil were cut and corrugated to replace the stock ribbon in an Apex 205 ribbon microphone. Prior to corrugation, half of the ribbons were sandwiched between two KimWipes and two pieces of cardstock then hammered to impart strain hardening. Each ribbon was placed into the microphone capsule and the frequency response of each ribbon was measured. A 10 second sine sweep from 20-20,000 Hz was played through a KRK Rokit 5 speaker and recorded through a ribbon microphone placed 6 inches away from the speaker cone. The signal generated by the ribbon …
The Synthesis And Characterization Of Gold And Silver Nanoparticles In Formal And Informal Settings, Mathew Wynn
The Synthesis And Characterization Of Gold And Silver Nanoparticles In Formal And Informal Settings, Mathew Wynn
Materials Engineering
Silver nanoparticles were synthesized through the reduction of AgNO3 using NaBH4. The borohydride anions were adsorbed onto silver nanoparticles. The repelling forces of the borohydride anions prevented the aggregation of particles, but the addition of an electrolyte or agitation induced aggregation. A yellow hue was given off by the silver nanoparticle sol that, using a spectrophotometer, had plasmon resonance at 386 nm. The silver nanoparticles were estimated to be 10 to 20 nm in diameter. Gold nanoparticles were synthesized through the reduction of HAuCl4 using Na3C6H5O7. The gold nanoparticle sol gave off a red hue that had plasmon resonance at …
Biaxial & Twist Testing Of Composite Carbon-Fiber Sandwich Panels For Automotive Racing Vehicles, Erik Eckberg
Biaxial & Twist Testing Of Composite Carbon-Fiber Sandwich Panels For Automotive Racing Vehicles, Erik Eckberg
Materials Engineering
Composite sandwich panels were constructed with 4-ply plain weave carbon-fiber/epoxy face sheets in the 0o/45o/0o/45o orientation and 1/8th inch Nomex honeycomb core. The panels were cut into 5-inch square test plates for mechanical testing. All testing was done on a fixture designed and fabricated by Pratt & Miller Engineering and installed on an Instron testing system at Cal Poly. The twist test was performed by supporting diagonal corners of the plate while simultaneously loading the opposite two corners at a crosshead rate of .06 in/min (ASTM 3044-94R11). Out of 10 panels tested, …
Analyzing The Corrosion Resistance Of Ni-Shield 200 Coatings At Different Temperatures When Exposed To Sulphuric Acid, Alex Hussinger
Analyzing The Corrosion Resistance Of Ni-Shield 200 Coatings At Different Temperatures When Exposed To Sulphuric Acid, Alex Hussinger
Materials Engineering
Six steel samples each were twin wire arc sprayed with Hastelloy C-276 or Nickel-Shield 200 coatings approximately 0.020″ thick. These samples were then cut into 3″ by 3″ squares. A 2″ diamond grit hole saw was used to abrade and polish to a smooth surface a ring in the middle in order to get an O-ring mechanical seal. The samples were then weighed and loaded into a jig that started from the bottom up with a stainless steel plate, then the sample, then a Viton O-ring, a ¾″ thick glass plate with a 1 3/4″ hole cut in it, another …
Corrosion Of Stainless Steel 316l And Astm F75 Cobalt Chromium Alloy During Immersion Testing In Silver Salt Solutions, Meagan Higgins
Corrosion Of Stainless Steel 316l And Astm F75 Cobalt Chromium Alloy During Immersion Testing In Silver Salt Solutions, Meagan Higgins
Materials Engineering
This study evaluates the potential effects of silver salts on biocompatible metals used for prostheses during the chemical reduction process to produce a silver antimicrobial layer on the metal’s surface. Samples of two biocompatible metals were obtained: Stainless Steel 316L and ASTM F75 Cobalt Chromium Alloy. Three different silver salts were also acquired: silver nitrate, silver sulfadiazine, and silver chloride. Specimens of each metal were cut to size using a 4-1/2 inch aluminum oxide, 40 grit, cut off wheel for metal, attached to a Dewalt Angle Grinder. The biocompatible metal samples were then subject to either Solution 1, water with …
Fabricating Replacement Glass Prisms For The Piedras Blancas Lighthouse, Daniel Garcken
Fabricating Replacement Glass Prisms For The Piedras Blancas Lighthouse, Daniel Garcken
Materials Engineering
The objective of this project was to design and create a process for manufacturing replacement glass prisms for the Piedras Blancas lighthouse and several other lighthouses nationwide. The prisms were designed to be in multiple metal arrays spread across the floor of the beacon room (the topmost room of the lighthouses). The prisms functioned to transmit extra, radiant light from the beacon light through the floor of the beacon room and disperse it into the maintenance room below. Using computer aided drafting (CAD) software, an original prism was measured and modeled; the corresponding mold was also modeled. G-codes for controlling …
Correlation Between 90o Tensile And 90o Flexural Properties For Thermoplastic Based Carbon-Fiber Composites, Amy Lautenbach
Correlation Between 90o Tensile And 90o Flexural Properties For Thermoplastic Based Carbon-Fiber Composites, Amy Lautenbach
Materials Engineering
Thermoplastic matrix composites containing carbon fibers and 4 different resins (TP 1-TP 4) were tested in tension with the fibers at 90 degree to the longitudinal axis following ASTM D 3039-00. The tensile strengths varied from 5.07-13.87 ksi with TP 1 as the strongest, and TP 4 as the weakest. SEM images were taken of the fracture surface of the samples to explore the fiber-matrix interaction. The SEM images showed significantly more wetting of the fibers in the higher strength materials. The SEM images of the two stronger materials showed resin coating the fibers even after fracture while the two …
The Effects Of Cure Schedule On Properties Of Glass-Fiber Reinforced Epoxy Matrix Composites, Trevor J. Lee
The Effects Of Cure Schedule On Properties Of Glass-Fiber Reinforced Epoxy Matrix Composites, Trevor J. Lee
Materials Engineering
Two different two-component resin systems were cured, via Differential Scanning Calorimetry, for the times recommended by their respective manufacturers. The resin cure schedules were designed to simulate typical and attainable processing conditions; they were cured at 120°F, 140°F, and 160°F, and in-mold post-cured at 200°F, 230°F, and 260°F. The resulting scans were then compared to a baseline cure for each resin system, consisting of two heating-cooling cycles at a constant rate of temperature change. These baseline cures were then used to determine the percent cure of each sample and the shift in glass transition temperature between the baseline cure and …
Artificial Muscle Project: Process Development Of Polydimethyl Siloxane Thin Films For Use In Dielectric Electroactive Polymer Artificial Muscle Actuators, Vincent J. Gayotin, Richard W. Morrison, Paul A. Preisser
Artificial Muscle Project: Process Development Of Polydimethyl Siloxane Thin Films For Use In Dielectric Electroactive Polymer Artificial Muscle Actuators, Vincent J. Gayotin, Richard W. Morrison, Paul A. Preisser
Materials Engineering
An artificial muscle design was created founded on the principles of a dielectric electroactive polymer (DEAP), which is fundamentally similar to a capacitor. A polydimethyl siloxane (PDMS)-based elastomer, Sylgard 184 from Dow Corning, was chosen for the design and spun coat onto polystyrene (PS) Petri dishes at varying speeds to create a thin film, using speeds of 2000 rpm, 3000 rpm, 4000 rpm, 5000 rpm, and 6000 rpm. The film thicknesses were measured optically through use of a microscope with coupled computer imaging software to generate a characteristic curve of film thickness to spin speed, achieving a minimum film thickness …
Understanding The Effects Of Temperature Extremes On The Tensile And Short Beam Shear Strength Of Epoxy-Based, Glass-Fiber Reinforced Composites, Jonathan Blake Patterson
Understanding The Effects Of Temperature Extremes On The Tensile And Short Beam Shear Strength Of Epoxy-Based, Glass-Fiber Reinforced Composites, Jonathan Blake Patterson
Materials Engineering
Aptera (Oceanside, CA) has developed two epoxy-based, silica fiber-reinforced composites to be used on their three-wheeled all-electric vehicle called the 2e. Aptera’s composites were studied at temperature extremes using a dynamic mechanical analysis (DMA) system and by tensile and short beam shear (SBS) testing using an Instron testing system. These tests were conducted to simulate the loading of the composite in the 2e vehicle. Tensile and short beam shear samples were machined to 150 mm x 25 mm x 2 mm and 40 mm x 13 mm x 6 mm, respectively. DMA samples were machined to 30 mm x 5 …
The Effects Of Heat Treatment On Area Percent Porosity And Corrosion Behavior Of High-Nickel Thermal Spray Coatings, Travis Crowe, Alec Guraydin
The Effects Of Heat Treatment On Area Percent Porosity And Corrosion Behavior Of High-Nickel Thermal Spray Coatings, Travis Crowe, Alec Guraydin
Materials Engineering
Samples of two Thermal Spray Coating (TSC) alloys on a low carbon steel substrate were obtained: alloy C276 and Nicko-Shield 200. Specimens of each alloy were subjected to heat treatments at temperatures at 1100° for 60 minutes and 1200° for 10 minutes, with some specimens left in the as-sprayed condition. Three replicates were prepared for each condition. Thin 1” strips were cut using a diamond wafering blade for porosity measurements and 2” x 1” specimens were cut for corrosion testing using a SiC abrasive saw. The porosity specimens were mounted in acrylic resin, polished, and examined using SEM. From these …
Characterization Of The Oxidation Kinetics Of Fecral Ferritic Stainless Steels At 900°C For Catalytic Converter Applications, Stacy Stamm
Materials Engineering
This study characterized the oxidation kinetics of two types of ferritic stainless steel foils used as substrates for catalytic converters. Catalytic converters rely on an alumina layer on the surface of the foils, which allows the catalyst to attach to the substrate. Because the alumina layer is so important, this study characterized the weight gain, thickness, and composition of the alumina as it grew at 900°C for up to 400 hours. The two foils characterized were an MK foil, used for gasoline engines, and an EMS foil, used for diesel engines. The MK foil showed a percent weight gain of …
Oxidation Kinetics Of Silver Thin Films For Antimicrobial Applications In The Health Care Industry, Sean D. Morham
Oxidation Kinetics Of Silver Thin Films For Antimicrobial Applications In The Health Care Industry, Sean D. Morham
Materials Engineering
To determine if varying city water qualities from around the United States can support a developing “oxidation corrosion of silver thin films” method of creating aqueous ionic silver solutions for the anti-microbial treatment of healthcare linens, a test was devised holding all variables constant with the exception of water quality parameters. This corrosion style test was done in order to assess a pass/fail criteria of 25 ppb ionic silver concentration in the aqueous solutions which resulted from the corrosion of silver thin film coated substrates. Above 25 ppb being a pass, below 25 ppb being a fail. While varying the …
Investigating The Mechanical Properties Of Compression Molded Carbon Fiber Reinforced Sheet Molding Compound, Bradley A. Jones
Investigating The Mechanical Properties Of Compression Molded Carbon Fiber Reinforced Sheet Molding Compound, Bradley A. Jones
Materials Engineering
Callaway Golf receives a proprietary blend of prepreg material from Quantum Composites. Callaway processes the prepreg in-house and supplied 254mm x 254mm x 1.3mm panels of carbon fiber sheet molding compound (CFSMC) for characterizing. Tensile strength was analyzed by conducting tensile tests per ASTM D3039. Tensile coupons were cut to 254mm long by 25.4mm wide. Tabs were constructed from 1.6mm thick GFRP printed circuit board material. A commercial grade two part epoxy was used to bond the tabs to the CFSMC. Tensile results were inconclusive due to consistent fractures occurring outside the gauge lengths of the specimens.
Flexure strength was …
Characterization Of Aluminum-Boron Carbide Particulate Metal Matrix Composites, Eric Blank
Characterization Of Aluminum-Boron Carbide Particulate Metal Matrix Composites, Eric Blank
Materials Engineering
The analysis of die-cast 380 aluminum-boron carbide particulate metal matrix composites (MMC) was performed in order to see if the samples had the required tensile strength of 300 MPa. 10wt% B4C die-cast samples were produced and tested. Half were heat treated to the T6 condition and the others were left as cast. Using ASTM standard B 557M it was found that the average tensile strength for the as-cast samples was 130 MPa and the heat treated samples had a tensile strength of 93 MPa. These values were both lower than expected. The heat treated samples were not expected to have …
Validation Of A Secondary Fabric Supplier And Characterization Of Alternate Cores For Use In The Aptera 2e Sandwich Core Composite, Bryan Rogers
Materials Engineering
Polymer matrix composites’ high strength to weight ratio has made them an ideal material choice for use in lightweight transportation vehicles. Aptera Motors, a company based out of Oceanside, CA, is currently developing a next-generation high efficiency passenger vehicle called the Aptera 2e. The 2e’s body is composed of a sandwich core composite containing laminates of E-glass fibers embedded within an epoxy matrix sandwiched between a polyester hexagonal core. This project looked to validate a secondary fabric supplier for use in Aptera’s composite and characterize the core shear properties of two alternate core materials for future iterations of Aptera’s vehicle. …
Using Living Materials To Intervene In The Natural Succession Process To Accelerate The Re-Development Of A Self-Sustaining Ecosystem That Has Been Damaged By Human Intervention, Eric Jorgensen
Materials Engineering
No abstract provided.