Hygrothermal Risk Assessment Of External Wall Insulation Retrofit To Non-Traditional Wall Types In An Irish Context, Using The Glaser Method And A Heat, Air And Moisture Transient Model, Gareth Mcdonnell, Joseph Little Jan 2024

Hygrothermal Risk Assessment Of External Wall Insulation Retrofit To Non-Traditional Wall Types In An Irish Context, Using The Glaser Method And A Heat, Air And Moisture Transient Model, Gareth Mcdonnell, Joseph Little

Articles

The Climate Action Plan 2019 targets the low-energy retrofit of 500,000 existing Irish homes before 2030.1 Up to 80 per cent of building failures can be attributed to moisture risks.2 The literature indicated that external wall insulation (EWI, ETICS) failures are mostly due to moisture ingress at junctions and interfaces. A hygrothermal risk assessment of EWI on three walls with rendered concrete/concrete blockwork/cavity walls in Dublin, Belfast and Belmullet was undertaken using transient numerical simulation and the Glaser method. The guidance, common practice indicates a preference for Glaser. The initial simulation results were compared to assess the appropriateness of Glaser. …


Optimal Temperature-Actuated Control Of A Thermally-Insulated Roller Blind, Hani Alkhatib, Philippe Lemarchand, Brian Norton, Dominic O'Sullivan Oct 2023

Optimal Temperature-Actuated Control Of A Thermally-Insulated Roller Blind, Hani Alkhatib, Philippe Lemarchand, Brian Norton, Dominic O'Sullivan

Articles

By altering the thermal equilibria between internal and ambient environments, dynamic insulation can minimize heating and cooling building energy requirements. The performance of a thermally-insulated roller blind was evaluated both experimentally and via simulation studies. The variation of blind position was optimized to minimize building energy consumption, maintain thermal comfort, and minimize daylight discomfort for a particular system, location and conditions. The roller blind was adjusted between four positions, from fully-open to fully-closed, optimal indoor temperature switching thresholds found for moving to these blind positions were 15 °C, 18.4 °C, 19.4 °C and 21.4 °C, respectively. Using these resulted in …


Compact Facility For Testing Steady And Transient Thermal Performance Of Building Walls, Aimee Byrne, Gerard Byrne, Anthony Robinson Jan 2017

Compact Facility For Testing Steady And Transient Thermal Performance Of Building Walls, Aimee Byrne, Gerard Byrne, Anthony Robinson

Articles

Energy efficiency retrofit of buildings represents a key effort in reducing EU energy demand by 20% by 2020. However, predictions tend to overestimate savings by large percentages. The shortfall in savings can be attributed to incorrect predictive techniques, comfort takeback along with other behavioural and workmanship variables. Common predictive techniques related to heat loss tend to be based on the U-value of the building envelope. This paper presents the design of a more straightforward and compact version of the traditional Hot-Box apparatus (measures U-value) which instead determines the thermal resistance of samples of building envelope. U-value includes the need to …


Case Studies Of Cavity And External Wall Insulation Retrofitted Under The Irish Home Energy Saving Scheme: Technical Analysis And Occupant Perspectives, Aimee Byrne, Gerard Byrne, Garrett O'Donnell, Anthony Robinson Jan 2016

Case Studies Of Cavity And External Wall Insulation Retrofitted Under The Irish Home Energy Saving Scheme: Technical Analysis And Occupant Perspectives, Aimee Byrne, Gerard Byrne, Garrett O'Donnell, Anthony Robinson

Articles

The residential sector represents 27% of primary energy consumption in Ireland. This paper examines the case study of the Irish government’s national grant scheme to encourage energy efficiency retrofit in private housing. That is the Home Energy Saving (HES) Scheme, later rebranded the Better Energy: Homes (BEH) Scheme. The methodology involved monitoring several homes immediately before and after retrofit alongside discussions with occupants. The examination focused on specific measures commonly introduced through the HES/BEH programme − cavity and external wall insulation. It has been found that a significant decrease in heat loss through the walls was measured in all cases. …


Hand-Held Flyback Driven Coaxial Dielectric Barrier Discharge: Development And Characterization, Victor J. Law, Vladimir Milosavljevic, Neil O’Connor, James F. Lalor, Steven Daniels Sep 2008

Hand-Held Flyback Driven Coaxial Dielectric Barrier Discharge: Development And Characterization, Victor J. Law, Vladimir Milosavljevic, Neil O’Connor, James F. Lalor, Steven Daniels

Articles

The development of a handheld single and triple chamber atmospheric pressure coaxial dielectric barrier discharge driven by Flyback circuitry for helium and argon discharges is described. The Flyback uses external metal-oxide-semiconductor field-effect transistor power switching technology and the transformer operates in the continuous current mode to convert a continuous dc power of 10–33 W to generate a 1.2–1.6 kV 3.5 μs pulse. An argon discharge breakdown voltage of ∼768 V is measured. With a 50 kHz, pulse repetition rate and an argon flow rate of 0.5–10 argon slm (slm denotes standard liters per minute), the electrical power density deposited in …