Recent Progress In Microrna Detection Using Integrated Electric Fields And Optical Detection Methods, Logeeshan Velmanickam, Dharmakeerthi Nawarathna Jan 2024

Recent Progress In Microrna Detection Using Integrated Electric Fields And Optical Detection Methods, Logeeshan Velmanickam, Dharmakeerthi Nawarathna

Electrical & Computer Engineering Faculty Publications

Low-cost, highly-sensitivity, and minimally invasive tests for the detection and monitoring of life-threatening diseases and disorders can reduce the worldwide disease burden. Despite a number of interdisciplinary research efforts, there are still challenges remaining to be addressed, so clinically significant amounts of relevant biomarkers in body fluids can be detected with low assay cost, high sensitivity, and speed at point-of-care settings. Although the conventional proteomic technologies have shown promise, their ability to detect all levels of disease progression from early to advanced stages is limited to a limited number of diseases. One potential avenue for early diagnosis is microRNA (miRNA). …


Quadrupoles For Remote Electrostimulation Incorporating Bipolar Cancellation, Shu Xiao, Ryo Yamada, Carol Zhou Jan 2020

Quadrupoles For Remote Electrostimulation Incorporating Bipolar Cancellation, Shu Xiao, Ryo Yamada, Carol Zhou

Bioelectrics Publications

Introduction: A method that utilizes nanosecond bipolar cancellation (BPC) near a quadrupole electrodes to suppress a biological response but cancels the distal BPC at the quadrupole center, i.e., cancellation of cancellation (CANCAN), may allow for a remote focused stimulation at the quadrupole center.

Objectives: The primary object of this study was to outline the requirement of the CANCAN implementation and select an effective quadrupole configuration.

Results: We have studied three quadrupole electrode configurations, a rod quadrupole, a plate quadrupole (Plate-Q), and a resistor quadrupole. The pulse shapes of electric fields include monophasic pulses, cancellation pulses, and additive pulses. The Plate-Q …


Ablation Of Myocardial Tissue With Nanosecond Pulsed Electric Fields, Fei Xie, Frency Varghese, Andrei G. Pakhomov, Iurii Semenov, Shu Xiao, Jonathan Philpott, Christian Zemlin Jan 2015

Ablation Of Myocardial Tissue With Nanosecond Pulsed Electric Fields, Fei Xie, Frency Varghese, Andrei G. Pakhomov, Iurii Semenov, Shu Xiao, Jonathan Philpott, Christian Zemlin

Bioelectrics Publications

Background

Ablation of cardiac tissue is an essential tool for the treatment of arrhythmias, particularly of atrial fibrillation, atrial flutter, and ventricular tachycardia. Current ablation technologies suffer from substantial recurrence rates, thermal side effects, and long procedure times. We demonstrate that ablation with nanosecond pulsed electric fields (nsPEFs) can potentially overcome these limitations.

Methods

We used optical mapping to monitor electrical activity in Langendorff-perfused New Zealand rabbit hearts (n = 12). We repeatedly inserted two shock electrodes, spaced 2–4 mm apart, into the ventricles (through the entire wall) and applied nanosecond pulsed electric fields (nsPEF) (5–20 kV/cm, 350 ns duration, …


Generation Of Bipolar Nanosecond Pulses, Sambasiva Rao Rajulapati Apr 2014

Generation Of Bipolar Nanosecond Pulses, Sambasiva Rao Rajulapati

Electrical & Computer Engineering Theses & Dissertations

Bipolar pulse generation has been studied using transmission line technology, which was mainly used for monopolar pulse generation. In this thesis, low impedance, high current, nanosecond pulse generators were designed, constructed and tested. Five transmission lines were connected in parallel, so the impedance was 10 n. The transmission lines were switched by a spark gap switch operated in air. The closing of the switch creates a matched condition on one side of the transmission lines and a short circuit on the other side of the transmission lines. When the transmission lines are precharged, one of the two waves in opposite …


Subnanosecond Exposure Systems For Biological Studies, Jongbong Nah Oct 2012

Subnanosecond Exposure Systems For Biological Studies, Jongbong Nah

Electrical & Computer Engineering Theses & Dissertations

The research of bioelectrics has expanded to subnanosecond pulse region and entered a new domain of biophysics of cell interaction with ultra-short and intense electric fields. As subnanosecond pulses may be delivered by antennas to the human body and is very attractive to the medical community, the study of subnanosecond pulse effects calls for exposure systems for both cells and tissues. Two systems were designed in the scope of this thesis, used for cells and tissues respectively. The exposure system designed for cell exposure is a cuvette consisting of two parallel aluminum gaps. This cuvette is placed in a coaxial …


Human Osteoblast Proliferation In Culture Following A Nanosecond Pulsed Electric Field (Nspef), Leonard Joseph Carinci Jr. Apr 2010

Human Osteoblast Proliferation In Culture Following A Nanosecond Pulsed Electric Field (Nspef), Leonard Joseph Carinci Jr.

Biological Sciences Theses & Dissertations

Osteoblasts are mononucleate bone forming cells responsible for the deposition of new bone. Application of mechanical stress on bone reveals its ability to produce and release electric potentials across the cell membrane called piezoelectricity. The electric potentials produced in response to mechanical stress may have a direct correlation on osseous cells and the signaling pathways that regulate proliferation. Nanosecond pulsed electric fields (nsPEFs) are high intensity, ultrashort pulses which have the ability to maintain the integrity of the cell membrane by avoiding traditional electroporation. We delivered 8 nsPEFs (0.5 Hz) of a 25 kV/cm or 35 kV/cm electric field strength …


Microfabrication Of An Optical Chamber For Exposing Living Cells To Pulsed Electric Fields, Saleh Sheikh Oct 2007

Microfabrication Of An Optical Chamber For Exposing Living Cells To Pulsed Electric Fields, Saleh Sheikh

Electrical & Computer Engineering Theses & Dissertations

I have fabricated a chamber which enables the application of Nanosecond Pulsed Electric Fields (nsPEFs) to living cells while monitoring their real time fluorescence with an inverted microscope. The No. I thickness (150µm nominal) coverslip glass substrate used for fabrication allows the use of high numerical aperture oil immersion objectives for imaging intracellular organelles. Electrodes are fabricated by first evaporating a chromium adhesion layer, followed by a nickel seed layer. Subsequently, an ultra-thick positive photoresist is applied and patterned to create a 30µm thick electroplating mold. The electrodes are then electrodeposited into the mold from a nickel sulfamate plating bath. …


The Effects Of Ultrashort Pulsed Electric Fields On The Fluorescent Molecule Bodipy Fl C5 Ceramide, Rachael Sara Shevin Oct 2006

The Effects Of Ultrashort Pulsed Electric Fields On The Fluorescent Molecule Bodipy Fl C5 Ceramide, Rachael Sara Shevin

Electrical & Computer Engineering Theses & Dissertations

Nanosecond pulsed electric fields are able to manipulate internal cell organelles by taking advantage of the small but finite time required for charge to establish across a capacitive barrier. Pulsed electric fields also affect macromolecular structures such as enzymes and proteins. Application of a single nanosecond pulsed electric field decreases the fluorescence of a commercially available biological dye Bodipy FL C5 Ceramide, used to observe the Golgi apparatus of living cells. The effect is seen when the fluorophore is exposed to an electric field both in vitro and when incorporated into the Golgi of a living Jurkat cell. Observation …


Time Domain Dielectric Spectroscopy Analysis Of Hl-60 Cell Suspensions After Microsecond And Submicrosecond Pulsed Electric Fields, Allen Laurence Garner Oct 2003

Time Domain Dielectric Spectroscopy Analysis Of Hl-60 Cell Suspensions After Microsecond And Submicrosecond Pulsed Electric Fields, Allen Laurence Garner

Electrical & Computer Engineering Theses & Dissertations

Pulsed electric fields (PEF's) above a certain voltage threshold cause electroporation for microsecond pulses and intracellular effects for submicrosecond pulses. Models describing these effects often depend on the electrical properties of the cell, which are altered by the PEF. Time domain dielectric spectroscopy was used to provide data for these models and to measure changes in the conductivity of HL-60 cell suspensions due to single 50 μs and 10 ns PEF's of the same energy. For 1.1 kV/cm, 50 μs pulses, the conductivity rose within a minute after the pulse and dropped dramatically approximately forty minutes after the pulse. For …