Open Access. Powered by Scholars. Published by Universities.®

Biomedical Commons

Open Access. Powered by Scholars. Published by Universities.®

Technological University Dublin

Discipline
Keyword
Publication Year
Publication
File Type

Articles 1 - 19 of 19

Full-Text Articles in Biomedical

Synthetic Heart Sound Dataset, Davoud Shariat Panah, Andrew Hines, Susan Mckeever Jan 2023

Synthetic Heart Sound Dataset, Davoud Shariat Panah, Andrew Hines, Susan Mckeever

Datasets

The repository contains synthetic heart sound recordings. The publication related to this dataset is "Exploring the impact of noise and degradations on heart sound classification models", Biomedical Signal Processing and Control journal.


Re-Annotation Of Cough Events In The Ami Corpus, Paul Leamy, Damon Berry, David Dorran, Ted Burke Jun 2019

Re-Annotation Of Cough Events In The Ami Corpus, Paul Leamy, Damon Berry, David Dorran, Ted Burke

Conference papers

Cough sounds act as an important indicator of an individual's physical health, often used by medical professionals in diagnosing a patient's ailments. In recent years progress has been made in the area of automatically detecting cough events and, in certain cases, automatically identifying the ailment associated with a particular cough sound. Ethical and sensitivity issues associated with audio recordings of coughs makes it more difficult for this data to be made publicly available. However, without the public availability of a reliable database of cough sounds, developments in the area of audio event detection are likely to be hampered. The purpose …


An Investigation Of Argumentation Theory For The Prediction Of Survival In Elderly Using Biomarkers, Lucas Middeldorf Rizzo, Ljiljana Majnaric, Pierpaolo Dondio, Luca Longo Jan 2018

An Investigation Of Argumentation Theory For The Prediction Of Survival In Elderly Using Biomarkers, Lucas Middeldorf Rizzo, Ljiljana Majnaric, Pierpaolo Dondio, Luca Longo

Conference papers

Research on the discovery, classification and validation of biological markers, or biomarkers, have grown extensively in the last decades. Newfound and correctly validated biomarkers have great potential as prognostic and diagnostic indicators, but present a complex relationship with pertinent endpoints such as survival or other diseases manifestations. This research proposes the use of computational argumentation theory as a starting point for the resolution of this problem for cases in which a large amount of data is unavailable. A knowledge-base containing 51 different biomarkers and their association with mortality risks in elderly was provided by a clinician. It was applied for …


Computational Tracking Of Shear-Mediated Platelet Interactions With Von Willebrand Factor, Adam Ralph, Martin Somers, Jonathan Cowman, Bruno Voisin, Emma Hogan, Hannah Dunne, Eimear Dunne, Barry Byrne, Nigel Kent, Antonio J. Ricco, Dermot Kenny, Simon Wong Jan 2016

Computational Tracking Of Shear-Mediated Platelet Interactions With Von Willebrand Factor, Adam Ralph, Martin Somers, Jonathan Cowman, Bruno Voisin, Emma Hogan, Hannah Dunne, Eimear Dunne, Barry Byrne, Nigel Kent, Antonio J. Ricco, Dermot Kenny, Simon Wong

Articles

The imaging of shear-mediated dynamic platelet behavior interacting with surface-immobilized von Willebrand factor (vWF) has tremendous potential in characterizing changes in platelet function for clinical diagnostics purposes. However, the imaging output, a series of images representing platelets adhering and rolling on the surface, poses unique, non-trivial challenges for software algorithms that reconstruct the positional trajectories of platelets. We report on an algorithm that tracks platelets using the output of such flow run experiments, taking into account common artifacts encountered by previously-published methods, and we derive seven key metrics of platelet dynamics that can be used to characterize platelet function. Extensive …


Footwear Antennas For Body Area Telemetry, Domenico Gaetano, Patrick Mcevoy, Max Ammann, Jacinta Browne, Louise Keating, Frances Horgan Oct 2013

Footwear Antennas For Body Area Telemetry, Domenico Gaetano, Patrick Mcevoy, Max Ammann, Jacinta Browne, Louise Keating, Frances Horgan

Articles

Antennas designed to link footwear sensors within body centric networks are introduced with two small UWB antennas, one directional and another quasi-omnidirectional. The radiating characteristics are evaluated for three positions on a sample sports shoe using a detailed simulation model and measurements with a homogenous foot phantom. Antenna performance is assessed for resilience to close proximity loading by the footwear materials and the phantom foot.


A Wireless And Digital Electrode Bus Topology For Biopotential Measurement, Mark Nolan, Edward Burke, Eugene Coyle Jun 2012

A Wireless And Digital Electrode Bus Topology For Biopotential Measurement, Mark Nolan, Edward Burke, Eugene Coyle

Conference Papers

The conventional biopotential measurement configuration utilises long lead wires which connect measuring electrodes to signal conditioning circuitry. The majority of bioelectric signals that are measured from the human body have a tiny signal amplitude (5µV-5mV range) and thus any interference that is induced on the lead wires can have a detrimental effect on the original signal. In this paper, we present an alternative configuration, in which digitisation occurs on the electrode, potentially providing enhanced signal measurement as well as significant benefits in terms of the simplification of the physical interconnections between electrodes. Multiple electrodes are combined to form a digital …


The Presence Of Regional Accents In Electrolarynx Speech And The Resultant Effect On Overall Intelligibility., Brian Madden, Eugene Coyle Apr 2012

The Presence Of Regional Accents In Electrolarynx Speech And The Resultant Effect On Overall Intelligibility., Brian Madden, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, a phonological analysis of a section of results from an online perceptual intelligibility test was performed which compared speech produced using a novel hands-free electrolarynx and a commercially available electrolarynx. A portion of the test consisted of a closed-set format containing a selection of four sets of four random CVC audio samples …


Radio-Frequency Breast Cancer Imaging Results For A Simplified Cylindrical Phantom, Giuseppe Ruvio, Raffaele Solimene, Antonietta D'Alterio, Max Ammann, Rocco Pierri Feb 2011

Radio-Frequency Breast Cancer Imaging Results For A Simplified Cylindrical Phantom, Giuseppe Ruvio, Raffaele Solimene, Antonietta D'Alterio, Max Ammann, Rocco Pierri

Conference Papers

Microwave imaging is a pervasive research field and
is useful in numerous applicative diagnostic noninvasive contexts. This paper focuses on two aspects. First, we perform a numerical investigation to assess the role played by fundamental parameters (i.e. number of sensors, operating frequency bandwidth) on cancer detection. To this end, a simplified cylindrical phantom probed by ideal two-dimensional dipoles (i.e. infinitely long along the axis of invariance) is considered. Second, in order to focus on the role of the antennas, we analyze, still by numerical simulations and for a simplified breast model, how performances vary when a realistic antenna is adopted.


Novel Bioelectrical Measurement Using A Digital Biopotential Monode, Mark Nolan, Edward Burke, Eugene Coyle Jan 2011

Novel Bioelectrical Measurement Using A Digital Biopotential Monode, Mark Nolan, Edward Burke, Eugene Coyle

Conference Papers

In conventional biopotential recording, two or more electrodes are placed on the body. A unipolar lead records the time-varying electrical potential at a single point (relative to a reference potential) via one signal electrode. A bipolar lead records the time-varying potential difference between two points via two signal electrodes. In each case, the signal electrodes are connected to high impedance amplifier inputs, while an additional electrode provides a low-impedance path between the amplifier and human subject. Bipolar leads are usually preferred since interference appearing at both signal electrodes can be eliminated using an instrumentation amplifier with high CMRR. A drawback …


Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jan 2011

Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, the intelligibility of speech produced using a novel hands-free actuator is compared to speech produced using a conventional electrolarynx. Two able-bodied speakers (one male, one female) performed a closed response test containing 28 monosyllabic words, once using a conventional electrolarynx and a second time using the novel design. The resulting audio recordings …


Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle Jan 2011

Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx acts as the sound source, providing a quasi-periodic excitation of the vocal tract. Following a total laryngectomy, some people speak using an electrolarynx which employs an electromechanical actuator to perform the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the monotonic sound emitted, the need for a free-hand to operate the device, and the difficulty experienced by many laryngectomees in adapting to its use. One improvement to the electrolarynx, which clinicians and users frequently suggest, is the provision of a convenient hands-free control facility. This would allow more natural use of …


On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle Jan 2011

On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle

Conference Papers

Eye tracking is a well-established method of computer control for profoundly paralysed people (Anson et al., 2002). Cameras are commonly used to track eye movements (Morimoto et al., 2005) but one alternative is the bioelectrical signal known as the electrooculogram (EOG). There are some EOG mouse control systems that facilitate the use of GUI applications, but certain actions, which are straightforward using a conventional mouse, remain impossible. Unless the eyes are tracking a target, they move in saccades (jumps), making it impossible to voluntarily trace out smooth trajectories with one's gaze, as would be required to draw a smooth curve. …


A Monocular Marker-Free Gait Measurement System, Jane Courtney, Annraoi M. De Paor Aug 2010

A Monocular Marker-Free Gait Measurement System, Jane Courtney, Annraoi M. De Paor

Articles

This paper presents a new, user-friendly, portable motion capture and gait analysis system for capturing and analyzing human gait, designed as a telemedicine tool to monitor remotely the progress of patients through treatment. The system requires minimal user input and simple single-camera filming (which can be acquired from a basic webcam) making it very accessible to nontechnical, nonclinical personnel. This system can allow gait studies to acquire a much larger data set and allow trained gait analysts to focus their skills on the interpretation phase of gait analysis. The design uses a novel motion capture method derived from spatiotemporal segmentation …


Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jun 2010

Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. Following a laryngectomy, some people speak using an electrolarynx which replaces the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the buzzing monotonic sound emitted, the need for a free hand to operate the device, and difficulty experienced by many laryngectomees in adapting to its use. Despite these shortcomings, it remains the preferred method of speech rehabilitation for a substantial minority of laryngectomees. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal …


An Electrooculogram-Based Binary Saccade Sequence Classification (Bssc) Technique For Augmentative Communication And Control, Johnalan Keegan, Ted Burke, James Condron Sep 2009

An Electrooculogram-Based Binary Saccade Sequence Classification (Bssc) Technique For Augmentative Communication And Control, Johnalan Keegan, Ted Burke, James Condron

Conference Papers

In the field of assistive technology, the electroocu-logram (EOG) can be used as a channel of communication and the basis of a man-machine interface. For many people with severe motor disabilities, simple actions such as changing the TV channel require assistance. This paper describes a method of detecting saccadic eye movements and the use of a saccade sequence classification algorithm to facilitate communication and control. Saccades are fast eye movements that occurs when a person's gaze jumps from one fixation point to another. The classification is based on pre-defined sequences of saccades, guided by a static visual template (e.g. a …


The Human Eye Position Control System In A Rehabilitation Setting, Yvonne Nolan, Ted Burke, C. Boylan, Annraoi De Paor Sep 2005

The Human Eye Position Control System In A Rehabilitation Setting, Yvonne Nolan, Ted Burke, C. Boylan, Annraoi De Paor

Articles

Our work at Ireland’s National Rehabilitation Hospital involves designing communication systems for people suffering from profound physical disabilities. One such system uses the electro-oculogram, which is an (x,y) system of voltages picked up by pairs of electrodes placed, respectively, above and below and on either side of the eyes. The eyeball has a dc polarisation between cornea and back, arising from the photoreceptor rods and cones in the retina. As the eye rotates, the varying voltages projected onto the electrodes drive a cursor over a mimic keyboard on a computer screen. Symbols are selected with a switching action derived, for …


An Electro-Oculogram Based System For Communication And Control Using Target Position Variation, Ronan Fitzmaurice, Ted Burke, Annraoi De Paor Jan 2005

An Electro-Oculogram Based System For Communication And Control Using Target Position Variation, Ronan Fitzmaurice, Ted Burke, Annraoi De Paor

Conference Papers

In this paper we describe a novel mode of human computer interaction based on gaze tracking using the electro-oculogram (EOG). Despite the relative simplicity of recording this signal, it is often discounted as a reliable method of gaze tracking because of problems arising from changing sensitivity and DC drift. We describe an original technique, Target Position Variation (TPV), which addresses this issue by presenting moving icons which, when followed with the eye, create a corresponding pattern in the EOG signal which can be used to infer the correct gaze position and to compensate for variations in sensitivity.


A System For Monitoring Pressures And Spinal Curvature In Spinally Injured People Immobilised On A Spinal Raft, Ruairí De Fréin, Eoin Flinn, Ted Burke May 2004

A System For Monitoring Pressures And Spinal Curvature In Spinally Injured People Immobilised On A Spinal Raft, Ruairí De Fréin, Eoin Flinn, Ted Burke

Articles

We present a system designed to study the pressure at various ‘hot spots’ on the back of the body and the deformation of the spine experienced by a patient when strapped to a spinal board, and the potential alleviation of both by the addition of an inflatable “spinal raft” (or other similar device). In measuring pressure we devised a system of air-filled sacks interfaced with a PC. Each sack, placed under a particular key point on the body, is inflated until its faces just begin to separate and a switch thereby opens. The pressure reading is then captured and displayed …


An Investigation Into Non-Verbal Sound-Based Modes Of Human-To-Computer Communication With Rehabilitation Applications, Ted Burke Jun 2003

An Investigation Into Non-Verbal Sound-Based Modes Of Human-To-Computer Communication With Rehabilitation Applications, Ted Burke

Conference Papers

During the course of our work in the National Rehabilitation Hospital in Ireland we have encountered patients who, while unable to speak, are capable of making reproducible utterances. We present techniques used to harness such utterances, in addition to whistling, as a means of communication and control. A simple technique for identifying the phonemes /o/ and /s/ (in single-symbol ARPAbet notation) is presented with applications. The use of pitch variation as a means of controlling a continuously variable parameter is described with two applications - a microcontroller based light dimmer switch and a computer program which facilitates mouse pointer control. …