Open Access. Powered by Scholars. Published by Universities.®

Biomedical Commons

Open Access. Powered by Scholars. Published by Universities.®

Signal Processing

Institution
Keyword
Publication Year
Publication
Publication Type

Articles 61 - 87 of 87

Full-Text Articles in Biomedical

Gui For Mri-Compatible Neural Stimulator And Recorder, Soo Han Soon, Nishant Babaria, Ranajay Mandal, Zhongming Liu Aug 2017

Gui For Mri-Compatible Neural Stimulator And Recorder, Soo Han Soon, Nishant Babaria, Ranajay Mandal, Zhongming Liu

The Summer Undergraduate Research Fellowship (SURF) Symposium

Functional magnetic resonance imaging (fMRI) and electroencephalography (EEG) are useful tools to analyze brain activities given active stimulation. However, the electromagnetic noise from the MRI distorts the brain signal recording and damages the subject with excessive heat generated on the electrodes attached to the skin. MRI-compatible recording and stimulation systems previously developed at LIBI lab were capable of removing the electromagnetic noise during the imaging process. Previously, the hardware systems had required the integrative software that could control both circuits simultaneously and enable users to easily change recording and stimulation parameters. Graphical user interface (GUI) programmed with computer language informed …


Multidataset Independent Subspace Analysis: A Framework For Analysis Of Multimodal, Multi-Subject Brain Imaging Data, Rogers F. Silva May 2017

Multidataset Independent Subspace Analysis: A Framework For Analysis Of Multimodal, Multi-Subject Brain Imaging Data, Rogers F. Silva

Electrical and Computer Engineering ETDs

Mental illnesses are serious disorders of the brain that have devastating effects on individuals and society. In addition to their disabling and impairing effects, mental illnesses have deep social and economical implications, accounting for an estimated loss of 12 billion working days and a care cost surge to $6 trillion a year by 2030. For diseases such as depression and anxiety, enhancing preventive programs and treatment accessibility, in combination with accurate early diagnosis and personalized treatments, are projected to result in a four-fold return on every dollar invested, a strategy that can drastically help curtail those losses. Notably, within the …


An Exact Analysis For Four-Order Acousto-Optic Bragg Diffraction Which Incorporates Both Incident Light Angle And Sound Frequency Dependencies, Adeyinka Sunday Ademola May 2017

An Exact Analysis For Four-Order Acousto-Optic Bragg Diffraction Which Incorporates Both Incident Light Angle And Sound Frequency Dependencies, Adeyinka Sunday Ademola

Electrical Engineering Theses

This thesis extends the prior work which produced an exact solution to the four-order acousto-optic (AO) Bragg cell with assumed fixed center frequency and with exact Bragg angle incident light. The extension predicts the model that incorporates the dependencies of both the input angle of light and the sound frequency. Specifically, a generalized 4th order linear differential equation (DE), is developed from a simultaneous analysis of four coupled AO system of DEs. Through standard methods, the characteristic roots, which requires solving a quartic equation, is produced. Subsequently, a derived system of homogeneous solutions, which absorbs the roots obtained using …


Silent Communication Device, Christopher Wayne Schutter Mar 2017

Silent Communication Device, Christopher Wayne Schutter

Master's Theses

Oral communication has constituted as a necessary aspect of how people interact with one another, but there are always situations where this form of communication can create distractions, irritation, or even danger. Take for example, a student in a laboratory who needs to communicate effectively with a lab partner without creating a distraction to those trying to work around said student or a soldier on a battlefield who needs to relay information effectively to his or her comrades without revealing his or her position to the enemy. It becomes apparent that people need a more exclusive form of communication in …


T1, T2, And Off-Resonance Mapping Using A Non-Linear Least-Squares Fit Of The Bssfp Signal, Meredith Taylor, Joseph Valentine, Steven Whitaker, Neal Bangerter Feb 2017

T1, T2, And Off-Resonance Mapping Using A Non-Linear Least-Squares Fit Of The Bssfp Signal, Meredith Taylor, Joseph Valentine, Steven Whitaker, Neal Bangerter

Biomedical Engineering Western Regional Conference

The mapping of MR relaxation times has found a broad variety of applications in the study of disease. Unfortunately, the gold standards for acquiring T1 and T2 maps require long scan times, and are therefore more suited to 2D acquisitions with limited slices. For reasonable scan times, resolution is limited making these scans less useful for showing fine morphological detail. A rapid 3D sequence at higher resolutions that could be used to provide both morphological detail and relaxation time maps would be particularly useful. We propose a technique with potential to provide simultaneous band-free 3D datasets and estimates …


Water Fat Separation With Multiple-Acquisition Bssfp Mri, Michael A. Mendoza 8232743, Joseph Valentine, Neal Bangerter Feb 2017

Water Fat Separation With Multiple-Acquisition Bssfp Mri, Michael A. Mendoza 8232743, Joseph Valentine, Neal Bangerter

Biomedical Engineering Western Regional Conference

We present a technique that combines the advantages of bSSFP MRI with Dixon reconstruction in order to produce robust water fat separation with high SNR in a short imaging time, while simultaneously reducing banding artifacts that traditionally degrade image quality.


Respiratory Prediction And Image Quality Improvement Of 4d Cone Beam Ct And Mri For Lung Tumor Treatments, Seonyeong Park Jan 2017

Respiratory Prediction And Image Quality Improvement Of 4d Cone Beam Ct And Mri For Lung Tumor Treatments, Seonyeong Park

Theses and Dissertations

Identification of accurate tumor location and shape is highly important in lung cancer radiotherapy, to improve the treatment quality by reducing dose delivery errors. Because a lung tumor moves with the patient's respiration, breathing motion should be correctly analyzed and predicted during the treatment for prevention of tumor miss or undesirable treatment toxicity. Besides, in Image-Guided Radiation Therapy (IGRT), the tumor motion causes difficulties not only in delivering accurate dose, but also in assuring superior quality of imaging techniques such as four-dimensional (4D) Cone Beam Computed Tomography (CBCT) and 4D Magnetic Resonance Imaging (MRI). Specifically, 4D CBCT used in CBCT …


A Comprehensive Analysis On Eeg Signal Classification Using Advanced Computational Analysis, Kaushik Bhimraj Jan 2017

A Comprehensive Analysis On Eeg Signal Classification Using Advanced Computational Analysis, Kaushik Bhimraj

College of Graduate Studies: Theses & Dissertations

Electroencephalogram (EEG) has been used in a wide array of applications to study mental disorders. Due to its non-invasive and low-cost features, EEG has become a viable instrument in Brain-Computer Interfaces (BCI). These BCI systems integrate user's neural features with robotic machines to perform tasks. However, due to EEG signals being highly dynamic in nature, BCI systems are still unstable and prone to unanticipated noise interference. An important application of this technology is to help facilitate the lives of the tetraplegic through assimilating human brain impulses and converting them into mechanical motion. However, BCI systems are remarkably challenging to implement …


Quantification Of Blood Flow Velocity Using Color Sensing, Aditya Deepak Sanghani Oct 2015

Quantification Of Blood Flow Velocity Using Color Sensing, Aditya Deepak Sanghani

Master's Theses

Blood flow velocity is an important parameter that can give information on several pathologies including atherosclerosis, glaucoma, Raynaud’s phenomenon, and ischemic stroke [2,5,6,10]. Present techniques of measuring blood flow velocity involve expensive procedures such as Doppler echocardiography, Doppler ultrasound, and magnetic resonance imaging [11,12]. They cost from $8500-$20000. It is desired to find a low-cost yet equally effective solution for measuring blood flow velocity. This thesis has a goal of creating a proof of concept device for measuring blood flow velocity.

Finger blood flow velocity is investigated in this project. The close proximity to the skin of the finger’s arteries …


Ecg Classification With An Adaptive Neuro-Fuzzy Inference System, Brad Thomas Funsten Jun 2015

Ecg Classification With An Adaptive Neuro-Fuzzy Inference System, Brad Thomas Funsten

Master's Theses

Heart signals allow for a comprehensive analysis of the heart. Electrocardiography (ECG or EKG) uses electrodes to measure the electrical activity of the heart. Extracting ECG signals is a non-invasive process that opens the door to new possibilities for the application of advanced signal processing and data analysis techniques in the diagnosis of heart diseases. With the help of today’s large database of ECG signals, a computationally intelligent system can learn and take the place of a cardiologist. Detection of various abnormalities in the patient’s heart to identify various heart diseases can be made through an Adaptive Neuro-Fuzzy Inference System …


Design, Characterization And Application Of A Multiple Input Stethoscope Apparatus, Spencer Geng Wong Aug 2014

Design, Characterization And Application Of A Multiple Input Stethoscope Apparatus, Spencer Geng Wong

Master's Theses

For this project, the design, implementation, characterization, calibration and possible applications of a multiple transducer stethoscope apparatus were investigated. The multi-transducer sensor array design consists of five standard stethoscope diaphragms mounted to a rigid frame for a-priori knowledge of their relative spatial locations in the x-y plane, with compliant z-direction positioning to ensure good contact and pressure against the subject’s skin for reliable acoustic coupling. When this apparatus is properly placed on the body, it can digitally capture the same important body sounds investigated with standard acoustic stethoscopes; especially heart sounds. Acoustic signal inputs from each diaphragm are converted to …


Nuclei/Cell Detection In Microscopic Skeletal Muscle Fiber Images And Histopathological Brain Tumor Images Using Sparse Optimizations, Hai Su Jan 2014

Nuclei/Cell Detection In Microscopic Skeletal Muscle Fiber Images And Histopathological Brain Tumor Images Using Sparse Optimizations, Hai Su

Theses and Dissertations--Computer Science

Nuclei/Cell detection is usually a prerequisite procedure in many computer-aided biomedical image analysis tasks. In this thesis we propose two automatic nuclei/cell detection frameworks. One is for nuclei detection in skeletal muscle fiber images and the other is for brain tumor histopathological images.

For skeletal muscle fiber images, the major challenges include: i) shape and size variations of the nuclei, ii) overlapping nuclear clumps, and iii) a series of z-stack images with out-of-focus regions. We propose a novel automatic detection algorithm consisting of the following components: 1) The original z-stack images are first converted into one all-in-focus image. 2) A …


Automated Channel Assessment For Single Chip Medradio Transceivers, Mark Alexander Hillig Jun 2013

Automated Channel Assessment For Single Chip Medradio Transceivers, Mark Alexander Hillig

Dissertations and Theses

Modern implantable and body worn medical devices leverage wireless telemetry to improve patient experience and expand therapeutic options. Wireless medical devices are subject to a unique set of regulations in which monitoring of the available frequency spectrum is a requirement. To this end, implants use software protocols to assess the in-band activity to determine which channel should be used. These software protocols take valuable processing time and possibly degrade the operational lifetime of the battery. Implantable medical devices often take advantage of a single chip transceiver as the physical layer for wireless communications. Embedding the channel assessment task in the …


Multi-Mode Self-Referencing Surface Plasmon Resonance Sensors, Jing Guo Jan 2013

Multi-Mode Self-Referencing Surface Plasmon Resonance Sensors, Jing Guo

Theses and Dissertations--Electrical and Computer Engineering

Surface-plasmon-resonance (SPR) sensors are widely used in biological, chemical, medical, and environmental sensing. This dissertation describes the design and development of dual-mode, self-referencing SPR sensors supporting two surface-plasmon modes (long- and short-range) which can differentiate surface binding interactions from bulk index changes at a single sensing location. Dual-mode SPR sensors have been optimized for surface limit of detection (LOD). In a wavelength interrogated optical setup, both surface plasmons are simultaneously excited at the same location and incident angle but at different wavelengths. To improve the sensor performance, a new approach to dual-mode SPR sensing is presented that offers improved differentiation …


Framework For Simulation Of Heterogeneous Mpsoc For Design Space Exploration, Bisrat Tafesse, Venkatesan Muthukumar Jan 2013

Framework For Simulation Of Heterogeneous Mpsoc For Design Space Exploration, Bisrat Tafesse, Venkatesan Muthukumar

Electrical & Computer Engineering Faculty Research

Due to the ever-growing requirements in high performance data computation, multiprocessor systems have been proposed to solve the bottlenecks in uniprocessor systems. Developing efficient multiprocessor systems requires effective exploration of design choices like application scheduling, mapping, and architecture design. Also, fault tolerance in multiprocessors needs to be addressed. With the advent of nanometer-process technology for chip manufacturing, realization of multiprocessors on SoC (MpSoC) is an active field of research. Developing efficient low power, fault-tolerant task scheduling, and mapping techniques for MpSoCs require optimized algorithms that consider the various scenarios inherent in multiprocessor environments. Therefore there exists a need to develop …


Multi-Circle Detections For An Automatic Medical Diagnosis System, Dingran Lu May 2012

Multi-Circle Detections For An Automatic Medical Diagnosis System, Dingran Lu

Master's Theses

Real-time multi-circle detection has been a challenging problem in the field of biomedical image processing, due to the variable sizes and non-ideal shapes of cells in microscopic images. In this study, two new multi-circle detection algorithms are developed to facilitate an automatic bladder cancer diagnosis system: one is a modified circular Hough Transform algorithm integrated with edge gradient information; and the other one is a stochastic search approach based on real valued artificial immune systems. Computer simulation results show both algorithms outperform traditional methods such as the Hough Transform and the geometric feature based method, in terms of both precision …


The Presence Of Regional Accents In Electrolarynx Speech And The Resultant Effect On Overall Intelligibility., Brian Madden, Eugene Coyle Apr 2012

The Presence Of Regional Accents In Electrolarynx Speech And The Resultant Effect On Overall Intelligibility., Brian Madden, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, a phonological analysis of a section of results from an online perceptual intelligibility test was performed which compared speech produced using a novel hands-free electrolarynx and a commercially available electrolarynx. A portion of the test consisted of a closed-set format containing a selection of four sets of four random CVC audio samples …


Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jan 2011

Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, the intelligibility of speech produced using a novel hands-free actuator is compared to speech produced using a conventional electrolarynx. Two able-bodied speakers (one male, one female) performed a closed response test containing 28 monosyllabic words, once using a conventional electrolarynx and a second time using the novel design. The resulting audio recordings …


Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle Jan 2011

Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx acts as the sound source, providing a quasi-periodic excitation of the vocal tract. Following a total laryngectomy, some people speak using an electrolarynx which employs an electromechanical actuator to perform the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the monotonic sound emitted, the need for a free-hand to operate the device, and the difficulty experienced by many laryngectomees in adapting to its use. One improvement to the electrolarynx, which clinicians and users frequently suggest, is the provision of a convenient hands-free control facility. This would allow more natural use of …


On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle Jan 2011

On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle

Conference Papers

Eye tracking is a well-established method of computer control for profoundly paralysed people (Anson et al., 2002). Cameras are commonly used to track eye movements (Morimoto et al., 2005) but one alternative is the bioelectrical signal known as the electrooculogram (EOG). There are some EOG mouse control systems that facilitate the use of GUI applications, but certain actions, which are straightforward using a conventional mouse, remain impossible. Unless the eyes are tracking a target, they move in saccades (jumps), making it impossible to voluntarily trace out smooth trajectories with one's gaze, as would be required to draw a smooth curve. …


Application Of Signal Advance Technology To Electrophysiology, Chris M. Hymel Aug 2010

Application Of Signal Advance Technology To Electrophysiology, Chris M. Hymel

Dissertations and Theses (Open Access)

Medical instrumentation used in diagnosis and treatment relies on the accurate detection and processing of various physiological events and signals. While signal detection technology has improved greatly in recent years, there remain inherent delays in signal detection/ processing. These delays may have significant negative clinical consequences during various pathophysiological events. Reducing or eliminating such delays would increase the ability to provide successful early intervention in certain disorders thereby increasing the efficacy of treatment.

In recent years, a physical phenomenon referred to as Negative Group Delay (NGD), demonstrated in simple electronic circuits, has been shown to temporally advance the detection of …


Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jun 2010

Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. Following a laryngectomy, some people speak using an electrolarynx which replaces the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the buzzing monotonic sound emitted, the need for a free hand to operate the device, and difficulty experienced by many laryngectomees in adapting to its use. Despite these shortcomings, it remains the preferred method of speech rehabilitation for a substantial minority of laryngectomees. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal …


Time-Frequency Analysis Of Intracardiac Electrogram, Erik Brockman Jun 2009

Time-Frequency Analysis Of Intracardiac Electrogram, Erik Brockman

Master's Theses

The Cardiac Rhythm Management Division of St. Jude Medical specializes in the development of implantable cardioverter defibrillators that improve the quality of life for patients diagnosed with a variety of cardiac arrhythmias, especially for patients prone to sudden cardiac death. With the goal to improve detection of cardiac arrhythmias, this study explored the value in time-frequency analysis of intracardiac electrogram in four steps. The first two steps characterized, in the frequency domain, the waveforms that construct the cardiac cycle. The third step developed a new algorithm that putatively provides the least computationally expensive way to identifying cardiac waveforms in the …


Least Squares Support Vector Machine Based Classification Of Abnormalities In Brain Mr Images, S. Thamarai Selvi, D. Selvathi, R. Ramkumar, Henry Selvaraj Mar 2006

Least Squares Support Vector Machine Based Classification Of Abnormalities In Brain Mr Images, S. Thamarai Selvi, D. Selvathi, R. Ramkumar, Henry Selvaraj

Electrical & Computer Engineering Faculty Research

The manual interpretation of MRI slices based on visual examination by radiologist/physician may lead to missing diagnosis when a large number of MRIs are analyzed. To avoid the human error, an automated intelligent classification system is proposed. This research paper proposes an intelligent classification technique to the problem of classifying four types of brain abnormalities viz. Metastases, Meningiomas, Gliomas, and Astrocytomas. The abnormalities are classified based on Two/Three/ Four class classification using statistical and textural features. In this work, classification techniques based on Least Squares Support Vector Machine (LS-SVM) using textural features computed from the MR images of patient are …


Electromyography (Emg) Signal Classification By Artificial Neural Networks, Behnam Dashtipour Jul 1997

Electromyography (Emg) Signal Classification By Artificial Neural Networks, Behnam Dashtipour

Electrical & Computer Engineering Theses & Dissertations

EMG signal processing is one of the active fields of biomedical signal processing. One unanswered question is how to determine whether a muscle is fatigued by analyzing the EMG signal. Fatigue detection could be useful in several different practical situations. There are several studies which show there are differences between EMG signal features before fatigue and after fatigue. Generally studies are based on an analytical analysis of the EMG signal instead of a quantitative analysis. In all previous studies in EMG signal processing for fatigue/nonfatigue detection, the result is that there exist some differences between the EMG signal before muscle …


Fetal Heart Rate Detection With A Passive Acoustic Sensor System, Zongyao Zhou Apr 1995

Fetal Heart Rate Detection With A Passive Acoustic Sensor System, Zongyao Zhou

Electrical & Computer Engineering Theses & Dissertations

Research and development is presented of real time signal processing methodologies for the detection of fetal heart tones from noise contaminated signals obtained from passive acoustic sensors. A nonlinear Teager energy operator is utilized for detection of the fetal heart tone event. Autocorrelation and a parallel redundancy correction algorithm derives fetal heart rates. A real time monitoring system is described which records and plots the time history of both the fetal heart rate and the acoustic fetal heart signal. The system is validated in the context of the fetal nonstress test. Comparisons are made with ultrasonic nonstress tests on a …


Signal Processing Methodologies For An Acoustic Fetal Heart Rate Monitor, Robert A. Pretlow Iii Apr 1991

Signal Processing Methodologies For An Acoustic Fetal Heart Rate Monitor, Robert A. Pretlow Iii

Electrical & Computer Engineering Theses & Dissertations

Research and development is presented of real time signal processing methodologies for the detection of fetal heart tones within a noise-contaminated signal from a passive acoustic sensor. A linear predictor algorithm is utilized for detection of the heart tone event and additional processing derives heart rate. The linear predictor is adaptively "trained" in a least mean square error sense on generic fetal heart tones recorded from patients. A real time monitor system is described which outputs to a strip chart recorder for plotting the time history of the fetal heart rate. The system is validated in the context of the …