Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- California Polytechnic State University, San Luis Obispo (5)
- University of Arkansas, Fayetteville (4)
- Purdue University (3)
- City University of New York (CUNY) (2)
- Louisiana State University (2)
-
- Portland State University (2)
- University of Nevada, Las Vegas (2)
- University of New Mexico (2)
- West Virginia University (2)
- Edith Cowan University (1)
- The Texas Medical Center Library (1)
- The University of Akron (1)
- University of Kentucky (1)
- University of Texas at Tyler (1)
- Virginia Commonwealth University (1)
- Keyword
-
- Biosensor (4)
- Fabrication (2)
- Piezoelectric (2)
- Acousto-Optic Bragg Diffractions - normalized space (1)
- Acousto-Optic Bragg diffraction with frequencies and input angle dependencies (1)
-
- Acousto-Optic Bragg diffraction-Analytical and Numerical solution for Four-order (1)
- Acousto-Optic with frequency and angle dependencies (1)
- Activation (1)
- Active (1)
- Active balance (1)
- An Exact Analysis for Four-Order Acousto-Optic Bragg Diffraction (1)
- Android Application (1)
- Applied sciences (1)
- Arrayed sensor (1)
- Battery operated (1)
- Biometric research (1)
- Biosensing (1)
- Body sensor networks (1)
- Bragg-reflector (1)
- Braille--Data processing (1)
- Breast cancer (1)
- COMSOL (1)
- Cardiac stimulation (1)
- Characterization (1)
- Charge balancer (1)
- Chemical stimulation (1)
- Chronoamperometry (1)
- Conductive (1)
- Contact Lens (1)
- Contact angle (1)
- Publication Year
- Publication
-
- Master's Theses (4)
- Birck and NCN Publications (3)
- Graduate Theses and Dissertations (3)
- Dissertations and Theses (2)
- Graduate Theses, Dissertations, and Problem Reports (ETD) (2)
-
- Mechanical Engineering ETDs (2)
- College of Engineering: Graduate Celebration Programs (1)
- Dissertations and Theses (Open Access) (1)
- Electrical & Computer Engineering Faculty Research (1)
- Electrical Engineering (1)
- Electrical Engineering Theses (1)
- Electrical Engineering Undergraduate Honors Theses (1)
- Electrical and Computer Engineering Faculty Publications and Presentations (1)
- LSU Doctoral Dissertations (1)
- LSU Master's Theses (1)
- Open Educational Resources (1)
- Research outputs 2014 to 2021 (1)
- Theses and Dissertations (1)
- Theses and Dissertations--Electrical and Computer Engineering (1)
- Williams Honors College, Honors Research Projects (1)
- Publication Type
Articles 1 - 30 of 30
Full-Text Articles in Biomedical
Electromagnetic Theory And Applications, 2nd Edition, Nicholas Madamopoulos, George Kliros
Electromagnetic Theory And Applications, 2nd Edition, Nicholas Madamopoulos, George Kliros
Open Educational Resources
This book intends to provide both the fundamentals of Electromagnetics but also some practical applications of the concepts covered. Having taught electromagnetics for several years, the authors feel that many times the field of electromagnetics comes as “old” and often times students do not appreciate the concepts and their importance in everyday applications. The authors intend to accompany the EM concepts with life applications. Hence, students may see the direct impact of the knowledge they acquire through the study of the field of electromagnetics and better appreciate the field.
Dual Base Sige Is-Hbt For Use In Biosensing Applications, Liam Stephen Hayes
Dual Base Sige Is-Hbt For Use In Biosensing Applications, Liam Stephen Hayes
Master's Theses
The proposed research is for a novel SiGe-based Ion-Sensitive Dual Hetero-junction Bipolar Transistor (IS-HBT) to be used in both trans-dermal biological sensing as well as Lab-on-Chip (LOC) applications. The end goals for the device designed are two: For one, the research done for this work will be used to substantiate the claims made by Zafar et al. [1] that an HBT-style structure is better suited for biosensing application rather than a conventional Field Effect Transistor (FET) based geometries. Secondly, it provides the final element to be integrated along with a selectivity membrane, as well as with a reverse-iontophoresis system to …
Cleaning And Characterization Of Chemical Vapor Deposited Graphene For Nanoelectronic Device Development, Sakib Ishraq
Cleaning And Characterization Of Chemical Vapor Deposited Graphene For Nanoelectronic Device Development, Sakib Ishraq
Graduate Theses, Dissertations, and Problem Reports (ETD)
Nanoelectronic devices based on graphene are a promising technology that combines the sensitivity and specificity of ion and element recognition with the accuracy and precision of electronics. The detection principle is based on the interaction of the target molecules with the nanodevice surface, which generates a measurable electrical signal. In the current study, graphene and its derivatives, synthesis and fabrication of high quality, good uniformity, and low defects graphene have been investigated as they are critical for high-performance and highly sensitive devices. Among many synthesis methods, chemical vapor deposition (CVD), have been used that needs to be transferred from the …
Design, Fabrication And Characterization Of Zero Power Sensor/Harvester For Smart Grid Applications, Zeynel Guler
Design, Fabrication And Characterization Of Zero Power Sensor/Harvester For Smart Grid Applications, Zeynel Guler
Mechanical Engineering ETDs
This study presents a flexible sensor/harvester device to be used in both electromagnetic sensing and energy harvesting applications for smart grids. When a current passes through a wire, the sensor detects the magnetic field created by that current. The sensor magnet interacts with the wire magnetic field resulting in a transfer of energy through the piezoelectric cantilever. Piezoelectric, conductive, magnetic, and magnetostrictive composite thin films were prepared to fabricate this device.
Initially, the magnet of the cantilever was optimized considering its shape, thickness, length, taper angle etc. via both simulations and experiments. Peak to peak voltage versus cantilever position graph …
Improving Cellphone-Based Bio-Imaging Technique For Fluorescence Detection, Erteza T. Efaz
Improving Cellphone-Based Bio-Imaging Technique For Fluorescence Detection, Erteza T. Efaz
LSU Master's Theses
The research presented in this thesis focuses on the design, development, and evaluation of a fluorescence detection system. The system is implemented primarily as an Android application, Auto Camera, which leverages smartphone cameras to capture and analyze fluorescent images. The application provides a user-friendly interface with some configurable features like exposure time, ISO speed, and storage limit; as well as defining detection thresholds and setting acquisition intervals. This study begins with the architectural framework of the Android application, which is written in Java using Android Studio. The API compatibility is set to version 33, and users are prompted to grant …
Material Characterization And Comparison Of Sol-Gel Deposited And Rf Magnetron Deposited Lead Zirconate Titanate Thin Films, Katherine Lynne Miles
Material Characterization And Comparison Of Sol-Gel Deposited And Rf Magnetron Deposited Lead Zirconate Titanate Thin Films, Katherine Lynne Miles
Mechanical Engineering ETDs
Lead zirconate titanate (PZT) has been a material of interest for sensor, actuator, and transducer applications in microelectromechanical systems (MEMS). This is due to their favorable piezoelectric, pyroelectric and ferroelectric properties. While various methods are available to deposit PZT thin films, radio frequency (RF) magnetron sputtering was selected to provide high quality PZT films with the added capability of batch processing. These sputter deposited PZT films were characterized to determine their internal film stress, Young’s modulus, composition, and structure. After characterization, the sputtered PZT samples were poled using corona poling and direct poling methods. As a means of comparison, commercially …
Design And Fabrication Of A Low-Cost, Portable, Battery-Operated Surface Enhanced Raman Scattering (Sers) Optical Device, Blessing Adewumi
Design And Fabrication Of A Low-Cost, Portable, Battery-Operated Surface Enhanced Raman Scattering (Sers) Optical Device, Blessing Adewumi
LSU Doctoral Dissertations
Raman Spectroscopy is a time-honored, non-invasive method for analyzing and identifying the molecular composition of materials. However, unenhanced Raman Spectroscopy has extremely low sensitivity which limits its sensing capability. SERS brings rough nano-metallic surfaces in contact with the material molecules to enormously enhance the Raman signals.
The sensitivity of SERS can be exploited in probe applications where the spectrometer needs to be brought near the specimen. For example, a long optical fiber coupled to a SERS device can be used to characterize and identify easy-to-reach cancerous tissues in organisms. Unfortunately, background signals in a long fiber can easily mask any …
Development Of Light Actuated Chemical Delivery Platform On A 2-D Array Of Micropore Structure, Hojjat Rostami Azmand, Hojjat Rostami Azmand
Development Of Light Actuated Chemical Delivery Platform On A 2-D Array Of Micropore Structure, Hojjat Rostami Azmand, Hojjat Rostami Azmand
Dissertations and Theses
Localized chemical delivery plays an essential role in the fundamental information transfers within biological systems. Thus, the ability to mimic the natural chemical signal modulation would provide significant contributions to understand the functional signaling pathway of biological cells and develop new prosthetic devices for neurological disorders. In this paper, we demonstrate a light-controlled hydrogel platform that can be used for localized chemical delivery in a high spatial resolution. By utilizing the photothermal behavior of graphene-hydrogel composites confined within micron-sized fluidic channels, patterned light illumination creates the parallel and independent actuation of chemical release in a group of fluidic ports. The …
On-Demand Electrically Induced Decomposition Of Thin-Film Nitrocellulose Membranes For Wearable Or Implantable Biosensor Systems, Benjamin M. Horstmann
On-Demand Electrically Induced Decomposition Of Thin-Film Nitrocellulose Membranes For Wearable Or Implantable Biosensor Systems, Benjamin M. Horstmann
Theses and Dissertations
Implantable or subcutaneous biosensors used for continuous health monitoring have a limited functional lifetime requiring frequent replacement and therefore may be highly discomforting to the patient and become costly. One possible solution to this problem is use of biosensor arrays where each individual reserve sensor can be activated on-demand when the previous one becomes inoperative due to biofouling or enzyme degradation. Each reserve biosensor in the array is housed in an individual Polydimethylsiloxane (PDMS) well and is protected from exposure to bodily fluids such as interstitial fluid ( ISF) by a thin-film nitrocellulose membrane. Controlled activation is achieved by decomposing …
Development Of A Comsol Microdialysis Model, Towards Creation Of Microdialysis On A Chip With Improved Geometries And Recovery, Patrick Pysz
Development Of A Comsol Microdialysis Model, Towards Creation Of Microdialysis On A Chip With Improved Geometries And Recovery, Patrick Pysz
Graduate Theses and Dissertations
Microdialysis (µD) sampling is a diffusion-limited sampling method that has been widely used in different biomedical fields for greater than 35 years. Device calibration for in vivo studies is difficult for current non-steady state analytes of interest correlated with both inflammatory response and microbial signaling molecules (QS); which exist in low ng/mL to pg/mL with molecular weights over a wide range of 170 Da to 70 kDa. The primary performance metric, relative recovery (RR), relating the collected sample to the extracellular space concentration varies from 10% to 60% per analyte even under controlled bench-top conditions. Innovations in microdialysis device design …
Fabrication And Characterization Of Nanofiber Nylon-6-Mwcnt As An Electrochemical Sensor For Sodium Ions Concentration Detection In Sweat, Kelsey Mills
Williams Honors College, Honors Research Projects
Fabrication and characterization nylon-6-MWCNT nanofiber as an electrochemical sensor to detect sodium ion concentrations specifically in sweat. Using contact angle to determine surface morphology and chronoamperometry testing to identify ideal sensor conditions, tests optimized parameters like weight percent of nylon or other polymers, carbon nanotube (CNT) isomer, and solution concentration to determine reproducibility of functional sensors. Utilizing the electric qualities of carbon nanotubes partnered with the sodium ion selectivity of calixarene treatment and polymers unique properties like flexibility and scalability create open an arena for optimizing sodium ion sensors for further development for functional prototypes. Morphology tests showed that the …
Engineering Plasmonic Nanostructures For Light Management And Sensing, Sujan Phani Kumar Kasani
Engineering Plasmonic Nanostructures For Light Management And Sensing, Sujan Phani Kumar Kasani
Graduate Theses, Dissertations, and Problem Reports (ETD)
The two major global problems are to provide health safety and to meet energy demands for ever growing population on a large scale. The study of light interaction with nanostructures has shown a promising solution in improving the fields of bio-sensor and solar energy devices which addresses above mentioned two major global problems. Nanostructures have tunable physicochemical properties such as light absorption, electrical and thermal properties unlike bulk materials, which gives an advantage in applications like bio-sensing and energy harvesting devices. The development of nanofabrication techniques along with the discovery of Surface Enhanced Raman Scattering (SERS) and Plasmon Enhanced Fluorescence …
Adaptation Of Vt-Dbr Lasers For Lidar, Luke Horowitz
Adaptation Of Vt-Dbr Lasers For Lidar, Luke Horowitz
Master's Theses
Vernier Tuned Distributed Bragg Reflector (VT-DBR) lasers have had great success in the field of Swept-Source Optical Coherence Tomography (SS-OCT) due to their continuous and nearly 40 nm wavelength tuning range in a single longitudinal mode. Fast sweeps allow for real time imaging with micrometer resolution at a distance of a few centimeters. While this laser has proven quite useful as a medical imaging tool via OCT, it has yet to similarly prove itself for general light detection and ranging (LIDAR) applications due to range limitations that arise from a finite laser coherence length. The goal of this thesis is …
Evaluation Of Terahertz Imaging For Breast Cancer Detection Using Image Morphing, Tanny Andrea Chavez Esparza
Evaluation Of Terahertz Imaging For Breast Cancer Detection Using Image Morphing, Tanny Andrea Chavez Esparza
Graduate Theses and Dissertations
This thesis proposes the use of a mesh morphing algorithm for the quantitative evaluation of terahertz (THz) images. This work differs from traditional evaluation methods based on qualitative evaluation because it provides a fair and quantitative measurement of the THz imaging system's performance. The objective of the algorithm is to match the alignment, shape, and resolution of the THz and reference pathology images. Therefore, the proposed morphing method provides a pathology reference for a pixel-by-pixel evaluation of the region classification in the THz image. To achieve this, the morphing algorithm aligns the images using the Pearson's correlation coefficient and reshapes …
Muscle Activity-Driven Green-Oriented Random Number Generation Mechanism To Secure Wbsn Wearable Device Communications, Yuanlong Cao, Guanghe Zhang, Fanghua Liu, Ilsun You, Guanglou Zheng, Oluwarotimi W. Samuel, Shixiong Chen
Muscle Activity-Driven Green-Oriented Random Number Generation Mechanism To Secure Wbsn Wearable Device Communications, Yuanlong Cao, Guanghe Zhang, Fanghua Liu, Ilsun You, Guanglou Zheng, Oluwarotimi W. Samuel, Shixiong Chen
Research outputs 2014 to 2021
Wireless body sensor networks (WBSNs) mostly consist of low-cost sensor nodes and implanted devices which generally have extremely limited capability of computations and energy capabilities. Hence, traditional security protocols and privacy enhancing technologies are not applicable to the WBSNs since their computations and cryptographic primitives are normally exceedingly complicated. Nowadays, mobile wearable and wireless muscle-computer interfaces have been integrated with the WBSN sensors for various applications such as rehabilitation, sports, entertainment, and healthcare. In this paper, we propose MGRNG, a novel muscle activity-driven green-oriented random number generation mechanism which uses the human muscle activity as green energy resource to generate …
An Exact Analysis For Four-Order Acousto-Optic Bragg Diffraction Which Incorporates Both Incident Light Angle And Sound Frequency Dependencies, Adeyinka Sunday Ademola
An Exact Analysis For Four-Order Acousto-Optic Bragg Diffraction Which Incorporates Both Incident Light Angle And Sound Frequency Dependencies, Adeyinka Sunday Ademola
Electrical Engineering Theses
This thesis extends the prior work which produced an exact solution to the four-order acousto-optic (AO) Bragg cell with assumed fixed center frequency and with exact Bragg angle incident light. The extension predicts the model that incorporates the dependencies of both the input angle of light and the sound frequency. Specifically, a generalized 4th order linear differential equation (DE), is developed from a simultaneous analysis of four coupled AO system of DEs. Through standard methods, the characteristic roots, which requires solving a quartic equation, is produced. Subsequently, a derived system of homogeneous solutions, which absorbs the roots obtained using …
Development Of An Oxygen Saturation Monitoring System By Embedded Electronics, Manikandan Venkatesan Gomathy
Development Of An Oxygen Saturation Monitoring System By Embedded Electronics, Manikandan Venkatesan Gomathy
Graduate Theses and Dissertations
Measuring Oxygenation of blood (SaO2) plays a vital role in patient’s health monitoring. This is often measured by pulse oximeter, which is standard measure during anesthesia, asthma, operative and post-operative recoveries. Despite all, monitoring Oxygen level is necessary for infants with respiratory problems, old people, and pregnant women and in other critical situations.
This paper discusses the process of calculating the level of oxygen in blood and heart-rate detection using a non-invasive photo plethysmography also called as pulsoximeter using the MSP430FG437 microcontroller (MCU). The probe uses infrared lights to measure and should be in physical contact with any peripheral points …
Toward Improving Electrocardiogram (Ecg) Biometric Verification Using Mobile Sensors: A Two-Stage Classifier Approach, Robin Tan, Marek Perkowski
Toward Improving Electrocardiogram (Ecg) Biometric Verification Using Mobile Sensors: A Two-Stage Classifier Approach, Robin Tan, Marek Perkowski
Electrical and Computer Engineering Faculty Publications and Presentations
Electrocardiogram (ECG) signals sensed from mobile devices pertain the potential for biometric identity recognition applicable in remote access control systems where enhanced data security is demanding. In this study, we propose a new algorithm that consists of a two-stage classifier combining random forest and wavelet distance measure through a probabilistic threshold schema, to improve the effectiveness and robustness of a biometric recognition system using ECG data acquired from a biosensor integrated into mobile devices. The proposed algorithm is evaluated using a mixed dataset from 184 subjects under different health conditions. The proposed two-stage classifier achieves a total of 99.52% subject …
Active Charge Balancing For Cardiac Stimulation, Maci Miri
Active Charge Balancing For Cardiac Stimulation, Maci Miri
Electrical Engineering
Worldwide, there are about 3 million people who have pacemakers, with 10,000 new implantations of ICD’s each month. [heart.org] Due to the gravity and importance of the function that ICD’s provide, these devices must be extremely reliable and highly effective. However, because of the high tolerances of IC manufacturing, stimulation circuits for pacemakers may be slightly unmatched and over time, may have a net DC charge applied to the tissues in the heart. Extra charge pumped into body tissues is dangerous for the patient’s health; the pH of the tissue can be raised and corrosion of the stimulating electrodes may …
Numerical And Analytical Modeling To Determine Performance Trade-Offs In Hydrogel-Based Ph Sensors, Piyush Dak, Muhammad Ashraful Alam
Numerical And Analytical Modeling To Determine Performance Trade-Offs In Hydrogel-Based Ph Sensors, Piyush Dak, Muhammad Ashraful Alam
Birck and NCN Publications
Hydrogel based pH sensors are promising candidates for implantable sensors due to their low-cost and biocompatibility. Despite their commercial potential and numerous theoretical/experimental reports, the trade-offs between different performance parameters are not well understood, and explicitly stated. In this work, we develop a numerical and analytical framework to show that there is a fundamental trade-off between the performance parameters i.e. sensitivity/dynamic range vs. response-time/response-asymmetry in hydrogel sensors under constrained swelling conditions. Specifically, we consider the effect of the gel parameters, such as the ionizable group density ( Nf) and its dissociation constant ( Ka), on the …
Characterization Of Two Vernier-Tuned Distributed Bragg Reflector (Vt-Dbr) Lasers Used In Swept Source Optical Coherence Tomography (Ss-Oct), Greg M. Bergdoll
Characterization Of Two Vernier-Tuned Distributed Bragg Reflector (Vt-Dbr) Lasers Used In Swept Source Optical Coherence Tomography (Ss-Oct), Greg M. Bergdoll
Master's Theses
Insight Photonic Solutions Inc. has continued to develop their patented VT-DBR laser design; these wavelength tunable lasers promise marked image-quality and acquisition time improvements in SS-OCT applications.
To be well suited for SS-OCT, tunable lasers must be capable of producing a highly linear wavelength sweep across a tuning range well-matched to the medium being imaged; many different tunable lasers used in SS-OCT are compared to identify the optimal solution.
This work electrically and spectrally characterizes two completely new all-semiconductor VT-DBR designs to compare, as well. The Neptune VT-DBR, an O-band laser, operates around the 1310 nm range and is a …
Design And Fabrication Techniques Of Devices For Embedded Power Active Contact Lens, Errol Heradio Leon
Design And Fabrication Techniques Of Devices For Embedded Power Active Contact Lens, Errol Heradio Leon
Master's Theses
This thesis designed and fabricated various devices that were interfaced to an IC for an active contact lens that notifies the user of an event by detection of an external wireless signal. The contact lens consisted of an embedded antenna providing communication with a 2.4GHz system, as well as inductive charging at an operating frequency of 13.56 MHz. The lens utilized a CBC005 5µAh thin film battery by Cymbet and a manufactured graphene super capacitor as a power source. The custom integrated circuit (IC) was designed using the On Semiconductor CMOS C5 0.6 µm process to manage …
Electronic Desalting For Controlling The Ionic Environment In Droplet-Based Biosensing Platforms, Vikhram Vilasur Swaminathan, Piyush Dak, Bobby Reddy Jr, Eric Salm, Carlos Duarte-Guevara, Yu Zhong, Andrew Fischer, Yi-Shao Liu, Rashid Bashir
Electronic Desalting For Controlling The Ionic Environment In Droplet-Based Biosensing Platforms, Vikhram Vilasur Swaminathan, Piyush Dak, Bobby Reddy Jr, Eric Salm, Carlos Duarte-Guevara, Yu Zhong, Andrew Fischer, Yi-Shao Liu, Rashid Bashir
Birck and NCN Publications
The ability to control the ionic environment in saline waters and aqueous electrolytes is useful for desalination as well as electronic biosensing. We demonstrate a method of electronic desalting at micro-scale through on-chip micro electrodes. We show that, while desalting is limited in bulk solutions with unlimited availability of salts, significant desalting of ≥1 mM solutions can be achieved in sub-nanoliter volume droplets with diameters of ∼250 μm. Within these droplets, by using platinum-black microelectrodes and electrochemical surface treatments, we can enhance the electrode surface area to achieve >99% and 41% salt removal in 1 mM and 10 mM salt …
Automated Channel Assessment For Single Chip Medradio Transceivers, Mark Alexander Hillig
Automated Channel Assessment For Single Chip Medradio Transceivers, Mark Alexander Hillig
Dissertations and Theses
Modern implantable and body worn medical devices leverage wireless telemetry to improve patient experience and expand therapeutic options. Wireless medical devices are subject to a unique set of regulations in which monitoring of the available frequency spectrum is a requirement. To this end, implants use software protocols to assess the in-band activity to determine which channel should be used. These software protocols take valuable processing time and possibly degrade the operational lifetime of the battery. Implantable medical devices often take advantage of a single chip transceiver as the physical layer for wireless communications. Embedding the channel assessment task in the …
Multi-Mode Self-Referencing Surface Plasmon Resonance Sensors, Jing Guo
Multi-Mode Self-Referencing Surface Plasmon Resonance Sensors, Jing Guo
Theses and Dissertations--Electrical and Computer Engineering
Surface-plasmon-resonance (SPR) sensors are widely used in biological, chemical, medical, and environmental sensing. This dissertation describes the design and development of dual-mode, self-referencing SPR sensors supporting two surface-plasmon modes (long- and short-range) which can differentiate surface binding interactions from bulk index changes at a single sensing location. Dual-mode SPR sensors have been optimized for surface limit of detection (LOD). In a wavelength interrogated optical setup, both surface plasmons are simultaneously excited at the same location and incident angle but at different wavelengths. To improve the sensor performance, a new approach to dual-mode SPR sensing is presented that offers improved differentiation …
A Refreshable And Portable E-Braille System For The Blind And Visually Impaired, Mohammad Saadeh, Mohamed Trabia
A Refreshable And Portable E-Braille System For The Blind And Visually Impaired, Mohammad Saadeh, Mohamed Trabia
College of Engineering: Graduate Celebration Programs
- Braille is a communication system to assist the blind and visually impaired.
- Present an approach to measure fingertip forces while identifying Braille characters.
- Implement a force sensory feedback in the device to measure the force developed on the fingertip.
- Introduce a preliminary design for the device.
- Build a prototype for the device and evaluate its functionality and integrate its components
Application Of Signal Advance Technology To Electrophysiology, Chris M. Hymel
Application Of Signal Advance Technology To Electrophysiology, Chris M. Hymel
Dissertations and Theses (Open Access)
Medical instrumentation used in diagnosis and treatment relies on the accurate detection and processing of various physiological events and signals. While signal detection technology has improved greatly in recent years, there remain inherent delays in signal detection/ processing. These delays may have significant negative clinical consequences during various pathophysiological events. Reducing or eliminating such delays would increase the ability to provide successful early intervention in certain disorders thereby increasing the efficacy of treatment.
In recent years, a physical phenomenon referred to as Negative Group Delay (NGD), demonstrated in simple electronic circuits, has been shown to temporally advance the detection of …
Theory Of ‘Selectivity’ Of Label-Free Nanobiosensors – A Geometro-Physical Perspective, Pradeep R. Nair, Muhammad A. Alam
Theory Of ‘Selectivity’ Of Label-Free Nanobiosensors – A Geometro-Physical Perspective, Pradeep R. Nair, Muhammad A. Alam
Birck and NCN Publications
Modern label-free biosensors are generally far more sensitive and require orders of magnitude less incubation time compared to their classical counterparts. However, a more important characteristic regarding the viability of this technology for applications in Genomics/Proteomics is defined by the ‘Selectivity’, i.e., the ability to concurrently and uniquely detect multiple target biomolecules in the presence of interfering species. Currently, there is no theory of Selectivity that allows optimization of competing factors and there are few experiments to probe this problem systematically. In this article, we use the elementary considerations of surface exclusion, diffusion limited transport, and void distribution function to …
Low Voltage, Low Power, Bulk-Driven Amplifier, Shama Huda
Low Voltage, Low Power, Bulk-Driven Amplifier, Shama Huda
Electrical Engineering Undergraduate Honors Theses
The importance of low voltage and low powered electronics is increasing with advances in medical electronics. This branch of electronics specifically requires low voltage and low power to make efficient innovative medical equipment. Low power electronics are also desirable because it conserves energy and power. This paper proposes a design of a differential in - differential our amplifier that uses a bulk-driven differential pair for the input pair. In addition, it also used bulk-driven current mirrors for the tail current sink and the active loads. The bulkdriven technique helps to achieve the low voltage design. 90nm CMOS technology was considered …
A Study Of Transconductance Degradation In Hemt Using A Self-Consistent Boltzmann-Poisson-Schrodinger Solver, Rahim Khoie
A Study Of Transconductance Degradation In Hemt Using A Self-Consistent Boltzmann-Poisson-Schrodinger Solver, Rahim Khoie
Electrical & Computer Engineering Faculty Research
A self-consistent Boltzmann-Poisson-Schrödinger Solver is used to study the transconductance degradation in high electron mobility transistor (HEMT), which has extensively been reported by both experimental [1]-[8] and computational [9]-[ 13] researchers. As the gate voltage of a HEMT device is increased, its transconductance increases until it reaches a peak value, beyond which, the transconductance is degraded rather sharply with further increase in applied gate bias. We previously reported a two-subband self-consistent Boltzmann-Poisson- Schrödinger Solver for HEMT. [14] We further incorporated an additional self-consistency by calculating field-dependent, energy-dependent intersubband and intrasubband scattering rates due to ionized impurities and polar optical phonons.[15] …