Assessment Of Electrode Configurations Of Electrical Impedance Myography For The Evaluation Of Neuromuscular Diseases, Khondokar Mohammad Fazle Rabbi Jan 2015

Assessment Of Electrode Configurations Of Electrical Impedance Myography For The Evaluation Of Neuromuscular Diseases, Khondokar Mohammad Fazle Rabbi

College of Graduate Studies: Theses & Dissertations

Electrical impedance myography (EIM) is a painless, noninvasive approach to measure the neuromuscular disease status. EIM parameters- resistance (R), reactance (X) and phase (θ) depend significantly on subcutaneous fat thickness, muscle size and inter electrode distance. The objective of this research is to find an electrode configuration which can minimize the effects on EIM parameters due to subcutaneous fat thickness variation. In this study, a model of human upper arm was developed using finite element method (FEM), which has already been established as an appropriate approach for the analysis of non-symmetrical shape for assessing alternations of muscle in disease-induced changes …


Induction Of Differentiation Of Dental Pulp-Derived Mesenchymal Stem Cells (Dpsc), Aubrey Young Dec 2014

Induction Of Differentiation Of Dental Pulp-Derived Mesenchymal Stem Cells (Dpsc), Aubrey Young

UNLV Theses, Dissertations, Professional Papers, and Capstones

Mesenchymal stem cells are derived from a variety of human tissues and are being bioengineered and studied for possible uses in the advancement of medicine. Recent efforts are being focused on Dental Pulp Stem Cells (DPSC's) due to the accessibility of this tissue. Many factors influence DPSC quality and quantity, including the specific methods used to isolate, collect, concentrate, and store these isolates once they are removed. Ancillary factors, such as the choice of media, the selection of early versus late passage cells, and cryopreservation techniques may also influence the differentiation potential and proliferative capacity of DPSC isolates.

The objective …


Medical Applications Of Mrc, Kyle Thackston, Henry Mei, Pedro Irazoqui Aug 2014

Medical Applications Of Mrc, Kyle Thackston, Henry Mei, Pedro Irazoqui

The Summer Undergraduate Research Fellowship (SURF) Symposium

Consistent powering is a limiting reagent for many medical implants and sensors. Powering in-vivo devices in animal studies requires either transcutaneous wiring (limiting mobility and increasing the chance of infection) or an implanted battery (limited lifetime and limits size of device). Wireless power transfer (WPT) would be able to overcome these challenges and permit the use of more advanced implantable devices in a research setting. Magnetic resonance coupling (MRC), an advanced form of inductive charging, allows good transfer efficiencies over significant air gaps, but works best a specific location and frequency, limiting mobility in animal studies. Using band-pass filter theory, …


Design, Characterization And Application Of A Multiple Input Stethoscope Apparatus, Spencer Geng Wong Aug 2014

Design, Characterization And Application Of A Multiple Input Stethoscope Apparatus, Spencer Geng Wong

Master's Theses

For this project, the design, implementation, characterization, calibration and possible applications of a multiple transducer stethoscope apparatus were investigated. The multi-transducer sensor array design consists of five standard stethoscope diaphragms mounted to a rigid frame for a-priori knowledge of their relative spatial locations in the x-y plane, with compliant z-direction positioning to ensure good contact and pressure against the subject’s skin for reliable acoustic coupling. When this apparatus is properly placed on the body, it can digitally capture the same important body sounds investigated with standard acoustic stethoscopes; especially heart sounds. Acoustic signal inputs from each diaphragm are converted to …


Cfd Simulation Of The Thermal Performance Of A Parallel Counter-Parallel Flow Heat Exchanger For The Treatment Of Hypothermia, Alex Heller Aug 2014

Cfd Simulation Of The Thermal Performance Of A Parallel Counter-Parallel Flow Heat Exchanger For The Treatment Of Hypothermia, Alex Heller

UNLV Theses, Dissertations, Professional Papers, and Capstones

Hypothermia is a life-threatening condition. Currently, active warming methods are the most effective treatment for dysthermic patients. The aim of this study is to investigate the use of computational fluid dynamics (CFD) in evaluating the thermal performance of a parallel/counter-parallel flow heat exchanger used as part of a fluid warmer to treat Hypothermia. The 3D model of the heat exchanger is divided into three regions; Infusate (fluid to be heated), Hot Water (heating fluid), and a Solid Region (wall). At the end of the heat exchanger, an elbow section is used to create the counter-parallel flow arrangement specific to this …


Preliminary Test Of A Real-Time, Interactive Silent Speech Interface Based On Electromagnetic Articulograph, Jun Wang, Ashok Samal, Jordan R. Green Jun 2014

Preliminary Test Of A Real-Time, Interactive Silent Speech Interface Based On Electromagnetic Articulograph, Jun Wang, Ashok Samal, Jordan R. Green

School of Computing: Conference and Workshop Papers

A silent speech interface (SSI) maps articulatory movement data to speech output. Although still in experimental stages, silent speech interfaces hold significant potential for facilitating oral communication in persons after laryngectomy or with other severe voice impairments. Despite the recent efforts on silent speech recognition algorithm development using offline data analysis, online test of SSIs have rarely been conducted. In this paper, we present a preliminary, online test of a real-time, interactive SSI based on electromagnetic motion tracking. The SSI played back synthesized speech sounds in response to the user’s tongue and lip movements. Three English talkers participated in this …


Sonar For The Visually Impaired, Anastasia Newark, Edwin Ng, Scott Terhorst Jun 2014

Sonar For The Visually Impaired, Anastasia Newark, Edwin Ng, Scott Terhorst

Biomedical Engineering

There are currently no inexpensive assistive devices that allow the visually impaired detect low hanging objects that are above waist height and may cause injury, such as a rope or tree branch. The challenge presented to the team by the Quality of Life Plus Lab (QL+) was to develop a Sonar Cane device that attaches to a traditional white cane to address this problem. This device must be lightweight, inexpensive to manufacture, have a long battery life, and accurately detect obstacles to prevent user injury.


A Quantitative Analysis Of A Paper-Based, Laser-Defined, Oxygen-Generating Platform For Chronic Wounds, Tiffany L. Huang, Babak Ziaie Oct 2013

A Quantitative Analysis Of A Paper-Based, Laser-Defined, Oxygen-Generating Platform For Chronic Wounds, Tiffany L. Huang, Babak Ziaie

The Summer Undergraduate Research Fellowship (SURF) Symposium

Chronic wounds affect 6.5 million patients a year while consuming US$25 billion in health care costs (Sen 2009 Wound Repair Regen.). Despite advances in wound management therapies, modern treatment for chronic wounds still requires continual professional attention and expensive equipment, posing serious practical and financial burdens for the regular patient. To provide an alternative solution, we are developing a low-cost smart bandage platform that integrates actuators and sensors to monitor and treat chronic wounds. One component of the integrated platform is an oxygen-generating module. It is a polydimethylsiloxane (PDMS) based microfluidic device fabricated on a parchment paper substrate that …


Design And Testing Of Novel Mouthguard With Intermediate Nitinol And Foam Layers, Adam Kessler May 2013

Design And Testing Of Novel Mouthguard With Intermediate Nitinol And Foam Layers, Adam Kessler

UNLV Theses, Dissertations, Professional Papers, and Capstones

It is the aim of this study to investigate a novel mouthguard design that incorporates the use of a nickel-titanium (Nitinol) layer and thin foam layer in addition to EVA layers. It is thought that the Nitinol layer can distribute the force of an impact and that the thin foam layer may absorb this distributed force better than a solid EVA mouthguard of the same thickness. Rectangular, flat coupons representative of several mouthguard configurations were constructed for testing using an instrumented drop-weight impact tower. The coupon configurations include a control made of laminated EVA, a group of laminated EVA and …


Closed Loop Control Of A Cylindrical Tube Type Ionic Polymer Metal Composite (Ipmc), Benjamin Mead May 2013

Closed Loop Control Of A Cylindrical Tube Type Ionic Polymer Metal Composite (Ipmc), Benjamin Mead

UNLV Theses, Dissertations, Professional Papers, and Capstones

The goal of this research is to provide a framework for the integration of tube type, cylindrical Ionic Polymer Metal-Composite (IPMC) into conventional devices. IPMCs are one of the most widely used types of electro-active polymer actuator, due to their low electric driving potential and large deformation range. For this research a tube type IPMC was investigated. This IPMC has a circular cross section with four separate electrodes on its surface and a hole through the middle. The four electrodes allow for biaxial bending and accurate control of the tip location. One of the main advantages of using this type …


A Wireless And Digital Electrode Bus Topology For Biopotential Measurement, Mark Nolan, Edward Burke, Eugene Coyle Jun 2012

A Wireless And Digital Electrode Bus Topology For Biopotential Measurement, Mark Nolan, Edward Burke, Eugene Coyle

Conference Papers

The conventional biopotential measurement configuration utilises long lead wires which connect measuring electrodes to signal conditioning circuitry. The majority of bioelectric signals that are measured from the human body have a tiny signal amplitude (5µV-5mV range) and thus any interference that is induced on the lead wires can have a detrimental effect on the original signal. In this paper, we present an alternative configuration, in which digitisation occurs on the electrode, potentially providing enhanced signal measurement as well as significant benefits in terms of the simplification of the physical interconnections between electrodes. Multiple electrodes are combined to form a digital …


Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser Jun 2012

Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser

Mechanical Engineering

Amputations are a common occurrence in soldiers returning home who have suffered the effects of IED and munitions explosions. For upper limb amputees, trans-radial amputations are the most common. Traditional hook devices do not offer an adequate level of normalcy for users, prompting the use of myoelectric devices. While current myoelectric devices do offer a more natural experience, they come with a host of other problems that makes their adoption by service personnel not desirable or not permitted by the VA. PolyGrasp Reach seeks to reduce weight and cost and improve performance. This addresses several of the issues with devices …


The Presence Of Regional Accents In Electrolarynx Speech And The Resultant Effect On Overall Intelligibility., Brian Madden, Eugene Coyle Apr 2012

The Presence Of Regional Accents In Electrolarynx Speech And The Resultant Effect On Overall Intelligibility., Brian Madden, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, a phonological analysis of a section of results from an online perceptual intelligibility test was performed which compared speech produced using a novel hands-free electrolarynx and a commercially available electrolarynx. A portion of the test consisted of a closed-set format containing a selection of four sets of four random CVC audio samples …


Cyberknife Radiation Modeling: Effects Of Relaxed Translational And Rotational Constraints On Healthy Tissue Irradiation, Sudha Bhavaroop Potineni Jul 2011

Cyberknife Radiation Modeling: Effects Of Relaxed Translational And Rotational Constraints On Healthy Tissue Irradiation, Sudha Bhavaroop Potineni

Electrical & Computer Engineering Theses & Dissertations

The Cyberknife system is a robotic radio surgery instrument that is used to treat cancers in different parts of the human body. Because of its accuracy and precision, it has become one of the best radio surgery systems in the world. However, even with Cyberknife the treatment time for one session takes from 30 minutes up to 120 minutes depending on the size, shape, and position of the tumor in the human body. In this research, a solution is presented to aid in reducing this long treatment time. An algorithm is developed which simulates the amount of the healthy tissue …


Heart-Rate Monitoring Control System Using Photoplethysmography (Ppg), Wesley Nguyen, Ryan Horjus Jun 2011

Heart-Rate Monitoring Control System Using Photoplethysmography (Ppg), Wesley Nguyen, Ryan Horjus

Electrical Engineering

No abstract provided.


Universal Engineering Programmer – An In-House Development Tool For Developing And Testing Implantable Medical Devices In St. Jude Medical, Khoa Tat Do Mar 2011

Universal Engineering Programmer – An In-House Development Tool For Developing And Testing Implantable Medical Devices In St. Jude Medical, Khoa Tat Do

Master's Theses

During development and testing of the functionality of the pacemaker and defibrillator device, engineers in the St. Jude Medical Cardiac Rhythm Management Division use an in-house development tool called Universal Engineering Programmer (UEP) to ensure the device functions as expected, before it can be used to test on an animal or a human during the implantation process.  In addition, some applications of UEP are incorporated into the official releases of the device product.  UEP has been developed and used by engineers across departments in the St. Jude Medical Cardiac Rhythm Management Division (CRMD).  This thesis covers the flexible and reusable …


Sar Map Of Gel Phantom In A 64mhz Mri Birdcage By Fiber-Optic Thermometry And Fdtd Simulation, Chirag Mukesh Patel Feb 2011

Sar Map Of Gel Phantom In A 64mhz Mri Birdcage By Fiber-Optic Thermometry And Fdtd Simulation, Chirag Mukesh Patel

Master's Theses

As implantable medical devices are being used more often to treat medical problems for which pharmaceuticals don’t suffice, it is important to understand their interactions with commonly used medical modalities. The interactions between medical implants and Magnetic Resonance Imaging machines have proven to be a risk for patients with implants.

Implanted medical devices with elongated metallic components can create harmful levels of local heating in a Magnetic Resonance Imaging (MRI) environment [1]. The heating of a biological medium under MRI is monitored via the Specific Absorption Rate (SAR). SAR, defined as power absorbed per unit mass (W/kg), can be calculated …


Novel Bioelectrical Measurement Using A Digital Biopotential Monode, Mark Nolan, Edward Burke, Eugene Coyle Jan 2011

Novel Bioelectrical Measurement Using A Digital Biopotential Monode, Mark Nolan, Edward Burke, Eugene Coyle

Conference Papers

In conventional biopotential recording, two or more electrodes are placed on the body. A unipolar lead records the time-varying electrical potential at a single point (relative to a reference potential) via one signal electrode. A bipolar lead records the time-varying potential difference between two points via two signal electrodes. In each case, the signal electrodes are connected to high impedance amplifier inputs, while an additional electrode provides a low-impedance path between the amplifier and human subject. Bipolar leads are usually preferred since interference appearing at both signal electrodes can be eliminated using an instrumentation amplifier with high CMRR. A drawback …


Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jan 2011

Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, the intelligibility of speech produced using a novel hands-free actuator is compared to speech produced using a conventional electrolarynx. Two able-bodied speakers (one male, one female) performed a closed response test containing 28 monosyllabic words, once using a conventional electrolarynx and a second time using the novel design. The resulting audio recordings …


Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle Jan 2011

Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx acts as the sound source, providing a quasi-periodic excitation of the vocal tract. Following a total laryngectomy, some people speak using an electrolarynx which employs an electromechanical actuator to perform the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the monotonic sound emitted, the need for a free-hand to operate the device, and the difficulty experienced by many laryngectomees in adapting to its use. One improvement to the electrolarynx, which clinicians and users frequently suggest, is the provision of a convenient hands-free control facility. This would allow more natural use of …


On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle Jan 2011

On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle

Conference Papers

Eye tracking is a well-established method of computer control for profoundly paralysed people (Anson et al., 2002). Cameras are commonly used to track eye movements (Morimoto et al., 2005) but one alternative is the bioelectrical signal known as the electrooculogram (EOG). There are some EOG mouse control systems that facilitate the use of GUI applications, but certain actions, which are straightforward using a conventional mouse, remain impossible. Unless the eyes are tracking a target, they move in saccades (jumps), making it impossible to voluntarily trace out smooth trajectories with one's gaze, as would be required to draw a smooth curve. …


Application Of Signal Advance Technology To Electrophysiology, Chris M. Hymel Aug 2010

Application Of Signal Advance Technology To Electrophysiology, Chris M. Hymel

Dissertations and Theses (Open Access)

Medical instrumentation used in diagnosis and treatment relies on the accurate detection and processing of various physiological events and signals. While signal detection technology has improved greatly in recent years, there remain inherent delays in signal detection/ processing. These delays may have significant negative clinical consequences during various pathophysiological events. Reducing or eliminating such delays would increase the ability to provide successful early intervention in certain disorders thereby increasing the efficacy of treatment.

In recent years, a physical phenomenon referred to as Negative Group Delay (NGD), demonstrated in simple electronic circuits, has been shown to temporally advance the detection of …


Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jun 2010

Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. Following a laryngectomy, some people speak using an electrolarynx which replaces the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the buzzing monotonic sound emitted, the need for a free hand to operate the device, and difficulty experienced by many laryngectomees in adapting to its use. Despite these shortcomings, it remains the preferred method of speech rehabilitation for a substantial minority of laryngectomees. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal …


Combining Molecular And Imaging Biomarkers To Enhance Maldi Biomarker Analysis, Ayyappa Chowdary Vadlamudi Apr 2010

Combining Molecular And Imaging Biomarkers To Enhance Maldi Biomarker Analysis, Ayyappa Chowdary Vadlamudi

Electrical & Computer Engineering Theses & Dissertations

This thesis presents a three-step method to predict prostate cancer (PCa) regions on biopsy tissue samples based on high confident, low resolution PCa regions marked by a pathologist. First, a prediction model is designed to predict PCa regions using matrix-assisted laser desorption mass spectrometry (MALDI-MS) tissue imaging data from one prostate tissue slice. Second, a texture analysis technique is applied to a high magnification optical image for the same purpose from an adjacent tissue slice. Finally, those two results are fused to obtain the PCa regions that will assist MALDI imaging biomarker analysis. Experiments show that the texture analysis based …


Theory Of ‘Selectivity’ Of Label-Free Nanobiosensors – A Geometro-Physical Perspective, Pradeep R. Nair, Muhammad A. Alam Jan 2010

Theory Of ‘Selectivity’ Of Label-Free Nanobiosensors – A Geometro-Physical Perspective, Pradeep R. Nair, Muhammad A. Alam

Birck and NCN Publications

Modern label-free biosensors are generally far more sensitive and require orders of magnitude less incubation time compared to their classical counterparts. However, a more important characteristic regarding the viability of this technology for applications in Genomics/Proteomics is defined by the ‘Selectivity’, i.e., the ability to concurrently and uniquely detect multiple target biomolecules in the presence of interfering species. Currently, there is no theory of Selectivity that allows optimization of competing factors and there are few experiments to probe this problem systematically. In this article, we use the elementary considerations of surface exclusion, diffusion limited transport, and void distribution function to …


Towards Supervised Autonomous Task Completion Using An In Vivo Surgical Robot, Jason J. Dumpert Oct 2009

Towards Supervised Autonomous Task Completion Using An In Vivo Surgical Robot, Jason J. Dumpert

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Laparoscopy is a minimally invasive alternative to traditional abdominal surgery. Unlike traditional surgery, a laparoscopic procedure can be completed using small incisions. The use of these small incision results in reduced pain to the patient, shorter recovery times, and less trauma to skin, muscle and other tissues. However, these benefits to the patient are offset by the increased difficulty to the surgeon performing the procedure. These difficulties include reduced dexterity, reduced perception, and longer procedure times. The use of small in vivo robotic devices in minimally invasive surgery is one possible solution to these problems. The movement of these devices …


Ekg Tracking For Augmented Standardized Patient Virtual Pathology Stethoscope Heart Auscultation, Sujith Surendran Oct 2009

Ekg Tracking For Augmented Standardized Patient Virtual Pathology Stethoscope Heart Auscultation, Sujith Surendran

Electrical & Computer Engineering Theses & Dissertations

In recent years, a lot of research has focused on improving the clinical skills of medical students and medical practitioners using standardized patients. Standardized patients (SP's) are used by the medical students and physicians in place of mannequins for a more realistic experience. SP's are real people trained to simulate specific illnesses and conditions to a high degree of accuracy which makes it difficult for the medical students to distinguish them from real patients. This research will enhance the capabilities of the standardized patients by providing a non-invasive, natural, harmless and realistic appearing tracking method for placing virtual pathologies using …


Time-Frequency Analysis Of Intracardiac Electrogram, Erik Brockman Jun 2009

Time-Frequency Analysis Of Intracardiac Electrogram, Erik Brockman

Master's Theses

The Cardiac Rhythm Management Division of St. Jude Medical specializes in the development of implantable cardioverter defibrillators that improve the quality of life for patients diagnosed with a variety of cardiac arrhythmias, especially for patients prone to sudden cardiac death. With the goal to improve detection of cardiac arrhythmias, this study explored the value in time-frequency analysis of intracardiac electrogram in four steps. The first two steps characterized, in the frequency domain, the waveforms that construct the cardiac cycle. The third step developed a new algorithm that putatively provides the least computationally expensive way to identifying cardiac waveforms in the …


Fetal Heart Rate Detection With A Passive Acoustic Sensor System, Zongyao Zhou Apr 1995

Fetal Heart Rate Detection With A Passive Acoustic Sensor System, Zongyao Zhou

Electrical & Computer Engineering Theses & Dissertations

Research and development is presented of real time signal processing methodologies for the detection of fetal heart tones from noise contaminated signals obtained from passive acoustic sensors. A nonlinear Teager energy operator is utilized for detection of the fetal heart tone event. Autocorrelation and a parallel redundancy correction algorithm derives fetal heart rates. A real time monitoring system is described which records and plots the time history of both the fetal heart rate and the acoustic fetal heart signal. The system is validated in the context of the fetal nonstress test. Comparisons are made with ultrasonic nonstress tests on a …


Signal Processing Methodologies For An Acoustic Fetal Heart Rate Monitor, Robert A. Pretlow Iii Apr 1991

Signal Processing Methodologies For An Acoustic Fetal Heart Rate Monitor, Robert A. Pretlow Iii

Electrical & Computer Engineering Theses & Dissertations

Research and development is presented of real time signal processing methodologies for the detection of fetal heart tones within a noise-contaminated signal from a passive acoustic sensor. A linear predictor algorithm is utilized for detection of the heart tone event and additional processing derives heart rate. The linear predictor is adaptively "trained" in a least mean square error sense on generic fetal heart tones recorded from patients. A real time monitor system is described which outputs to a strip chart recorder for plotting the time history of the fetal heart rate. The system is validated in the context of the …